Tender For Special Repairs To Leaky Roof, Doors, Painting And Providing Waiting Shed Arrangements In Hsc At Vediyangadu In Thiruvallur District.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Nov 2026
10 days left
EMD
8900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Leaky Roof, Doors, Painting And Providing Waiting Shed Arrangements In Hsc At Vediyangadu In Thiruvallur District.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and clearing away and carefully stacking the materials useful for reuse of plain Cement concrete. |
| 2 | Supplying and filling in foundation, basement, etc with filling Crushed Stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 3 | Relaying of Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by Manual means. |
| 4 | Relaying of Cement Concrete 1:2:4 (One Cement, Two crushed stone sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including Super Plasticiser, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - manual mix |
| 5 | In Ground Floor |
| 6 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 7 | Renewing the damaged floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 8 | Double charged Vitrified Tiles 600 x 600 x 8mm |
| 9 | Renewing the damaged flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 10 | Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm |
| 11 | Renewing the dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 12 | Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm |
| 13 | Renewing the damaged Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. |
| 14 | 50mm thick slab (using 20mm HBGS Jelly) |
| 15 | Renewing the damaged granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers). |
| 16 | For 40mm thick |
| 17 | Reconstruction of Brick work in following Cement Mortar 1:6 (one cement six sans) using best quality Burnt Clay Brick of size 9\\" x 4 3/8\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally other type of bond shall be done as directed by the Executive Engineer in charge. |
| 18 | In Ground Floor |
| 19 | Replastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 20 | Renewing and refixing of Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. |
| 21 | Easing the existing over hanging doors and windows including nerewing frame its position and refixing the same after attending petty repair works including for wrough and putup in position fixing necessary furniture excluding cost of aurniture etc., complete complying with standard specification as directed by the departmental officers at site of work. |
| 22 | Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 23 | Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 24 | Renewing and refixing of polyurethane foam for Sloped roofas thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification. |
| 25 | 50mm (+38mm) thick PUF roof panel |
| 26 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 27 | Renewing and refixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). White Glazed Wash Hand Basin. Without Pedestal. |
| 28 | Renewing and refixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) |
| 29 | White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall |
| 30 | Renewing and refixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. |
| 31 | 110mm Dia |
| 32 | 75mm Dia |
| 33 | Renewing and refixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re- doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 34 | 110mm dia PVC Bend |
| 35 | 110mm dia PVC Tee |
| 36 | 110mm dia PVC Elbow |
| 37 | 75mm dia PVC Bend |
| 38 | 75mm dia PVC Tee |
| 39 | 75mm dia PVC Elbow |
| 40 | Renewing and refixing of PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - External water supply - above ground level / Below ground level. |
| 41 | 25mm dia (AGL) EWS |
| 42 | 20mm dia (AGL) EWS |
| 43 | Renewing and refixing PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements |
| 44 | 25mm dia PVC Tee |
| 45 | 20mm dia PVC Tee |
| 46 | 25mm dia PVC Elbow |
| 47 | 20mm dia PVC Elbow |
| 48 | 25x20mm dia Reducer Tee |
| 49 | 20x15mm dia Reducer Tee |
| 50 | Renewing and refixing of cylindrical vertical notational polythene water storage tank of 500 litres capacity confirming to I S. 12701 / 96. the tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., and the tank should be fixed firmly as directed. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the dept., Officers. |
| 51 | Renewing and refixing of fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed by the departmental officers. |
| 52 | 38 / 40mm thick |
| 53 | Renewing and refixing in position of MS steel framed weldmesh partition of using MS angle of size 40x40x6mm for outer frame and the inner vertical and horizontal frames are made T section of 25 x 6mm and placed at 75cm c/c in either directors and welded in with best quality weld mesh of size 50 x 25mm 10 (gage) and welded in frames and fixed in position and the rate are including of welding eletrodes, painting with a coat of red oxide anticorrosive primer including cost of paint, transporting, loading and unloading and fixing in position with necessary welding hold faste etc., complete complying with standard specifications. |
| 54 | Renewing and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set(c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No., Level Switch - 1 No. & |
| 55 | Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact50 Litres |
| 56 | GST 18 % Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender