Tender For special Repairs To Fafa Dd (Jco) Drain Culvert And Allied Works Under Age Br-Ii Ge (East) Lucknow

Issued by Statutory Bodies & Commissions/Committees · Lucknow, Uttar Pradesh
Tender Value
37.68 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
4 days left
EMD
75360
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repairs To Fafa Dd (Jco) Drain Culvert And Allied Works Under Age Br-Ii Ge (East) Lucknow

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 19-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-Nov-2026

BOQ

Name of Work:- SPL REPAIRS TO FAFA DD (JCO) DRAIN CULVERT AND ALLIED WORKS UNDER AGE BR-II GE (EAST) LUCKNOW
Sl. No. Item Description
1Excavation in trenches n. exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier hole etc not exc 10 sqm on plan and not exc 1.5 m depth and getting out in soft/loose soil complete all as specified and directed.
2Returning filling in trenches including spreading leveling, watering and well ramming in layer not exc 25 cm thick complete all as specified and directed.
3Removing of excavated materials to a distance 1.5km and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
4Demolition and breaking up drain pipes (SGSW, AC or RCC) of 150mm bore sizes, set in cement mortar complete all as specified and directed.
5S&F of underground PP/PE Double Wall Corrugated (DWC) anti-rodent pipes of stiffness class SN-8,100mm conforming to IS 16098 (Part II), having smooth inner surface and corrugated outer surface, including all fittings and accessories, jointing with rubber ring joints as per manufacturer’s specifications, laid to required slope and alignment at specified depths in accordance with complete specifications, including testing as directed by the Engineer-in-Charge.
6S&F of underground PP/PE Double Wall Corrugated (DWC) anti-rodent pipes of stiffness class SN-8,150mm conforming to IS 16098 (Part II), having smooth inner surface and corrugated outer surface, including all fittings and accessories, jointing with rubber ring joints as per manufacturer’s specifications, laid to required slope and alignment at specified depths in accordance with complete specifications, including testing as directed by the Engineer-in-Charge.
7M&L for cement concrete type C-2 (1:3:6) using 20 mm nominal size graded stone aggregate for bedding to drain pipes of 150 mm bore , including packing under and hunching against the sides of pipes after they are laid and tested, laid to proper line and level, including mixing, placing, ramming, compaction, finishing and curing of concrete complete,as per IS 269/IS 8112/IS 12269, fine aggregate conforming to IS 383, coarse aggregate 20 mm nominal size conforming to IS 383, and water conforming to IS 456, with allconcrete work carried out in accordance with IS 456:2000, complete all as specified and directed by Engineer-in-Charge.
8M&L for cement concrete type C-2 (1:3:6) using 20 mm nominal size graded stone aggregate for bedding to drain pipes of 100 mm bore , including packing under and hunching against the sides of pipes after they are laid and tested, laid to proper line and level, including mixing, placing, ramming, compaction, finishing and curing of concrete complete,as per IS 269/IS 8112/IS 12269, fine aggregate conforming to IS 383, coarse aggregate 20 mm nominal size conforming to IS 383, and water conforming to IS 456, with allconcrete work carried out in accordance with IS 456:2000, complete all as specified and directed by Engineer-in-Charge.
9Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thick above or below ground level complete all as specified and directed
10M&L PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in Surface channel or drains including necessary form works, stops, moulds etc complete all as specified and directed.
11Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including necessary forms mould mitred /stopped ends etc complete all as specified and directed.Note : Only inner girth shall be measured and paid.
12Add or deduct for each 25mm girth or part thereof over or under 30cm ditto
13M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintel up to 1.5m clear span, cills, steps, bands, coping including weathering, slightly rounded or champhered, angle and throating as directed and other similar work all as specified including necessary form work complete all as specified and directed.
14M&L for 50mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor surface finished even and smooth without using extra cement complete all as specified and directed.
15Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
16M & L, brick work with fly ash bricks old size, straight or curved on plan exc. 6.0M mean radius, built in cement mortar 1:6 complete all as specified and directed.
17All as per Item No 15 above but except bricks. (Bricks recd from demolition shall be reused after removing and cleaning of old mortar) complete all as specified and directed
18M & L for brick work with fly ash bricks, old size, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed.
19M&L for Taking down cement plaster of any description on brick/stone walls including raking out joints, hacking for key and cleaning the surface with water complete, and M&L for 15 mm thick rendering using factory manufactured ready mix cement based plaster on fair faces of brick work or concrete surfaces, finished even and smooth, including surface preparation, mixing with potable water, application and curing complete, conforming to IS 1661, IS 2250 and IS 2402, with water proofing compound @ 3% by weight of cement in plaster, complete all as specified and directed by the Engineer-in-Charge.Note : WPC shall be measured and paid separately
20M&L for Taking down cement plaster of any description on brick/stone walls including raking out joints, hacking for key and cleaning the surface with water complete, and M&L for 15 mm thick rendering using factory manufactured ready mix cement based plaster on other than fair faces of brick work or concrete surfaces, finished even and smooth, including surface preparation, mixing with potable water, application and curing complete, conforming to IS 1661, IS 2250 and IS 2402, with water proofing compound @ 3% by weight of cement in plaster, complete all as specified and directed by the Engineer-in-Charge.Note : WPC shall be measured and paid separately
21Supply only integral waterproofing compound of approved make complete all as specified and directed.
22Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed
23S&F of pre cast frame SFRC (Steel Fibre Reinforced Concrete) of approved make, size 900mm X 900 mm and load bearing capacity as specified, conforming to relevant IS standards, including fixing in cement concrete (1:2:4) or as specified, properly set, embedded and aligned to finished ground/road level, including all labour, materials, tools and incidental charges, complete as specified and directed by the Engineer-in-Charge.
24S&F of SFRC (Steel Fibre Reinforced Concrete) manhole/inspection cover 75mm thick of approved make, size and load bearing capacity as specified, with anti-skid chequered surface and provision for lifting arrangement, conforming to relevant IS standards, including placing over the fixed frame, complete with all labour, materials, tools and incidental charges, complete as specified and directed by the Engineer-in-Charge.
25Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar works; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
26Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs n exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide complete all as specified and directed
27M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
28All as per Item No 27 above but 6mm to 8mm dia ditto
29All as per item No 27 above but 5mm dia and over upto and including 10 mm dia in stirrups,apacers and binders -do-
30M & L for RCC 1:1.5:3 (Nominal Mix) using 20 mm graded stone agg as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
31M&L for Cutting into existing manholes/Septic tank/Soakwell for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching for internal dia 100/ 150 mm pipes complete all as specified and directed.
32Taking down rain water pipes (any size or pattern) incl all fittings, shoes, bends, swan neck etc complete all as specified and directed.
33S&F of 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed.
34S&F of 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed.
35M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
36M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
37S&F of 110mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
38S&F of 75mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
39Material & Labour for preparation of old external surfaces of walls and applying Two coats of 100% Premium acrylic emulsion paint with PU serum, colour stay technology having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. Note- Primer and emulsion to be carried out through air less spray machine with Mechanical means
40Excavation in over areas not exc. 1.50 m deep and getting out in soft / loose soil complete all as specified and directed.
41Excavation in over areas exc 1.5 m deep for each additional 1.5 m or part thereof in depth beyond the first 1.5 m and getting out as directed by Engineer-incharge
42M&L cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) as in sub base , and mass concrete complete all as specified and directed.
43M&L Providing precast cement concrete Type B1 1:2:4 (20mm graded crushed stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as directed and specified.
44M&L for drilling 300mm dia borehole by DTH cum rotary at any depth below the ground level in any kind of rock/soil incl hard stone/boulders incl electronic logging, MS cap, MS flt iron clamp, reducing socket etc up to 150 m depth incl disposal of surplus soil to a distance exc 5 km away complete all as directed and specified. Note- The depth of drilling bore shall be upto water table and will be directed by Engr-in-charge
45S&F self perforated unplasticised PVC pipes 200mm dia of pressure rating 10kg/Sqcm heavy duty fixed with stack clamps on drilling bores complete all as specified. Note-The rates quoted in above items is deemed to be inclusive of all T&P equipments and labour required for execution of this item at site including transportation charge for the said T&P equipments and no extra cost shall be paid for the same.
46Supply and loose filling of broken stone boulders of guage 40 to 80 mm in pits, wells all as apecified and directed.
47Supply and filling of pea Gravel/moorum/red bajri filling in bore holes to pack PVC slotted pipe to receive natural rain water complete all as apecified and directed.
48Supply and filling of sand filling (200 mm thick) under floors or in foundations including watering and consolidation complete all as apecified and directed.
49M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
50M&L for preparation of new or previously untreated surfaces, of steel and iron work of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of Red oxide all as specified and as directed.
51M&L uPVC rain water gutter pipes of size 150/110mm/75mm bore pipes of 3mm thick (4 Kg/cm2) as required at site fixed with suitable clamps in roof projections / roof outlet including bends,reducer, water filter gratings, of sizes 150mm/110mm/75mm bore fixed with joint sealing adhesive composite complete on wall / along the roof projections complete all as specified and as directed by Engr-in-charge. (Note : The items will be measured in RM incl all fittings items )
52M & L Reinforced concrete pipes(hume pipe), class NP3, with bore dia 450 mm laid and jointed complete with collars in trenches complete all as apecified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58259558
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 37.68 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repairs To Fafa Dd (Jco) Drain Culvert And Allied Works Under Age Br-Ii Ge (East) Lucknow
Basic Detail
Tender No GE/E/LKO/T-90 OF 2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 19 Nov 2026
Submission Date 26 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 37.68 Lakhs
Tender Fee 500
EMD 75360
Exemption Available
Document List
57c38d4e-5c20-4c43-8793-943b06eccf7c.html
BOQ_893133.xls
Tendernotice_1.pdf
TenderT90.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

57c38d4e-5c20-4c43-8793-943b06eccf7c.html

xls

BOQ_893133.xls

pdf

Tendernotice_1.pdf

pdf

TenderT90.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender