Tender For Provision Of Maintenance Infrastructure And Associated Facilities For Hale Rpa At installation Rajali, Arakkonam
Tender Value
123.50 Crore
Estimated cost
Bid Submission
05 Dec 2026
36 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranipet → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Maintenance Infrastructure And Associated Facilities For Hale Rpa At installation Rajali, Arakkonam
BOQ
| Sl. No. | Item Description |
| 1 | Schedule \\"A\\" Part – I [BUILDINGS & STRUCTURES] |
| 2 | Construction of hangar of RCC framed structure with PEB structure complete all as specified and as shown on drawings and as directed. |
| 3 | Construction of covered parking area [CPA] of steel strucure alongwith PU complete all as specified and as shown on drawings. |
| 4 | Construction of maintenance facilities, ware house, shipping and receiving centre complete all as specified and as shown on drawings. |
| 5 | Construction of ware house using steel structure and RCC framed structure [lean] complete all as specified and as shown on drawings. |
| 6 | Construction of Sentry box complete all as specified and as shown on drawings. |
| 7 | Construction of sentry box with attached toilet complete all as specified and as shown on drawings. |
| 8 | Construction of POL store complete all as specified and as shown on drawings. |
| 9 | Construction of PUMP house with RCC framed structure complete all as specified and as shown on drawings. |
| 10 | Construction of Sub station building with RCC framed structure complete all as specified and as shown on drawings. |
| 11 | Construction of Parking shed with RCC framed structure complete all as specified and as shown on drawings. |
| 12 | Construction of Staitc water tank of capacity 50000 litres complete all as specified and as shown on drawings. |
| 13 | Construction of concrete pad complete all as specified and as shown on drawings. |
| 14 | Construction of RCC septic tank for 100 users complete all as specified and as shown on drawings. |
| 15 | Construction of 50 users RCC septic tank for carry sludge water, excavation in any type of soil, PCC 1:4:8 type D2 below foundation , vent shafts, connection etc., for conventional type complete all as specified and as shown on drawings. |
| 16 | Construction of Soakage well of size 4.3 metre dia x 3 metre effective depth excavation, foundation in PCC 1:3:6 type C2, walls of honey combed masonary with top ring of M30 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M30/SFRC cover interconnecting pipes of DWC complete filled with brick bats of size complete all as specified and as shown on drawings. |
| 17 | Construction of Soakage well of size 3.0 metre dia x 3 metre effective depth excavation, foundation in PCC 1:3:6 type C2, walls of honey combed masonary with top ring of M30 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M30/SFRC cover interconnecting pipes of DWC complete filled with brick bats of size complete all as specified and as shown on drawings. |
| 18 | Schedule \\"A\\" Part – II to Schedule \\"A\\" Part – XXV:NOTE: Schedule \\"A\\" Part – II to Part – XXV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only |
| 19 | Lumpsum price worked out by the contractor for \\"Site Clearance / Earthwork/ Excavation/ Area development\\", as listed in Schedule \\"A\\" Part – II . |
| 20 | Lumpsum price worked out by the contractor for \\"Internal Electrification\\", as listed in Schedule \\"A\\" Part – III . |
| 21 | Lumpsum price worked out by the contractor for \\"Internal Water Supply\\", as listed in Schedule \\"A\\" Part – IV . |
| 22 | Lumpsum price worked out by the contractor for \\"Sewage Disposal \\", as listed in Schedule \\"A\\" Part – V . |
| 23 | Lumpsum price worked out by the contractor for \\"External Water Supply\\", as listed in Schedule \\"A\\" Part – VI |
| 24 | Lumpsum price worked out by the contractor for \\"External Electrification\\", as listed in Schedule \\"A\\" Part – VII |
| 25 | Lumpsum price worked out by the contractor for Roads/Path / hard standing/Culvert\\", as listed in Schedule \\"A\\" Part – VIII . |
| 26 | Lumpsum price worked out by the contractor for \\"Area drainage\\", as listed in Schedule \\"A\\" Part – IX |
| 27 | Lumpsum price worked out by the contractor for \\"Compound Wall/ Fencing/ Gate\\", as listed in Schedule \\"A\\" Part – X |
| 28 | Lumpsum price worked out by the contractor for \\"Fire fighting and fire alarm system\\", as listed in Schedule \\"A\\" Part – XI |
| 29 | Lumpsum price worked out by the contractor for \\"Lightning Protection\\", as listed in Schedule \\"A\\" Part – XII |
| 30 | Lumpsum price worked out by the contractor for \\"PVC Conduit\\", as listed in Schedule \\"A\\" Part – XIII |
| 31 | Lumpsum price worked out by the contractor for \\"Crane\\", as listed in Schedule \\"A\\" Part – XIV |
| 32 | Lumpsum price worked out by the contractor for \\"AC Plant\\", as listed in Schedule \\"A\\" Part – XV |
| 33 | Lumpsum price worked out by the contractor for \\"Summer appliances\\", as listed in Schedule \\"A\\" Part – XVI . |
| 34 | Lumpsum price worked out by the contractor for \\"Arboriculture\\", as listed in Schedule \\"A\\" Part – XVII |
| 35 | Lumpsum price worked out by the contractor for \\"DG Set\\", as listed in Schedule \\"A\\" Part – XVIII |
| 36 | Lumpsum price worked out by the contractor for \\"OBSRTUCTION LIGHT\\", as listed in Schedule \\"A\\" Part – XIX |
| 37 | Lumpsum price worked out by the contractor for \\"Special power supply\\", as listed in Schedule \\"A\\" Part – XX |
| 38 | Lumpsum price worked out by the contractor for \\"DISPERSAL AND TAXILINK & RUNWAY RE-SURFACING\\", as listed in Schedule \\"A\\" Part – XXI |
| 39 | Lumpsum price worked out by the contractor for \\"Boom barrier\\", as listed in Schedule \\"A\\" Part – XXII |
| 40 | Lumpsum price worked out by the contractor for \\"Air Craft Grounding\\", as listed in Schedule \\"A\\" Part – XXIII |
| 41 | Lumpsum price worked out by the contractor for \\"Rain water harvesting\\", as listed in Schedule \\"A\\" Part – XXIV |
| 42 | Schedule \\"A\\" Part - XXV [Miscellaneous Items] |
| 43 | Internal Electrification |
| 44 | S&F Modular white colour cover plate with frame 12 module complete all as specified and as directed. |
| 45 | S&F Modular metal metal flush box 8 module complete all as specified and as directed. |
| 46 | S&F Modular metal metal flush box 12 module complete all as specified and as directed. |
| 47 | Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including non metallic PVC rigid Conduit concelaed, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and prefabricated Pressed steel terminal box of suitable size made out of 1.2 mm thick sheets for mounting modular brackets as reuqired at site for fixing modular type switches, sockets including one run of 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified. |
| 48 | All as per Serial Item No. 43 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified. |
| 49 | All as per Serial Item No. 43 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified. |
| 50 | All as per item No.43 here-in-before but controlled by two two way switch complete all as specefied and directed. |
| 51 | All as per Serial Item No. 43 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLSH grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade,2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor. |
| 52 | All as per Serial Item No. 43 above but point wiring with 1.5 Sq.mm , FRLSH grade, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade,1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor for flame proof light fitting drawn through stover enamelled steel conduit |
| 53 | All as per Serial Item No. 43 above but point wiring with 4.0 Sq.mm , FRLSH grade, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade,4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor for flame proof 16 Amps sockets drawn through stover enamelled steel conduit |
| 54 | Supply and fix LED buld in B22 base 09 Watts environmental friendly [Contains no mercury, UV/IR free light] complete all as specified and as directed. |
| 55 | S&F LED fitting with decorative box type with driver, holder of capacity 2x 20W, 220V, 4 feet including LED tube light with all accessories internally pre-wired and including and connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 56 | S&F LED down lighter ultra slim square surface mounting type with excellent thermally managed aluminium pressure die-cast housing with heat - dissipating fins finished in epoxy powder coated white 18 Watts, 230 Volts, decorative type with driver, holder and LED lamp and all accessories internally pre-wired and including and connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 57 | S & F MCCB DB, vertical double door, TP, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCCB FP as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed. |
| 58 | S & F MCCB DB, vertical double door, TP, 8 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCCB FP as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed. |
| 59 | M & L for sub-main wiring with 1.5 sqmm nominal area Two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 1.5 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.Note :(i) Two run of 1.5 Sqmm + one run of 1.5 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 60 | M & L for sub-main wiring with 4.0 sqmm nominal area Two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 61 | M & L for sub-main wiring with 6.0 sqmm nominal area Two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 62 | M & L for sub-main wiring with 10.0 sqmm nominal area Two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.Note :(i) Two run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 63 | M & L for sub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including two 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.Note :(i) Four run of 10.0 Sqmm + two run of 10.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 64 | M & L for sub-main wiring with 16.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including two 16.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.Note :(i) Four run of 16.0 Sqmm + two run of 16.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 65 | Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed. |
| 66 | M & L for sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through stover enamelled steel conduit of suitable size for flame proof SPN DB complete all as specified and as directed.Note :(i) two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of stover enamelled steel conduit shall be measured as an one Unit. |
| 67 | Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed. |
| 68 | Supply, fix and testing of Energy saving, environment friendly & robust Highbay LED not less then 140/150 Watts IP 66 luminaire with high efficiency light fitting with all connecting neccessary arrangements of nut, bolts, welding works complete all as specified and as directed. |
| 69 | Supply, fix and testing of Energy saving, environment friendly & robust Highbay LED not less then 100/110 Watts IP 66 luminaire with high efficiency light fitting with all connecting neccessary arrangements of nut, bolts, welding works complete all as specified and as directed. |
| 70 | Supply and fix power socket of 100 Amp capacity complete all as specified and as directed |
| 71 | Supply and fix Pedestral fan 18\\" (450) mm sweep complete all as specified |
| 72 | Supply and fix Air Circulator fan wall mounted type complete with metal blades and accessories, 230 Volt AC, 600 mm sweep, minimum air delivery 260 CFM with copper wound motor and double ball bearing and 85 degree oscillation.Make: CAT No. AGVORTEX24WM of Crompton or its equivalent in Orient/Havells as approved by GE. |
| 73 | S&F VTPN MCCB DB , double door three phase, 415 Volts, 12 way suitable for MCCB FP 250 Amps as incoming and MCB(TP/SP) as outgoing, IP 43 protection complete all as specified and directed. |
| 74 | S&F VTPN MCCB DB, double door three phase, 415 Volts, 8 way suitable for MCCB FP 63 Amp as incoming and MCB(TP/SP) as outgoing, IP 43 protection complete all as specified and directed. Please Enable Macros to View BoQ information |
| 75 | S&F VTPN MCCB DB, double door three phase, 415 Volts, 8 way suitable for MCCB FP 63 Amp as incoming and MCB(TP/SP) as outgoing, IP 43 protection complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 36 daysDec 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 43 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender