Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58259552

Tender For Repair/Maint Of Dg Set, Transformer, Vcb, Lt Panel, Mccbs And Allied Works At Area B At Af Station Wadsar

Issued by Statutory Bodies & Commissions/Committees · Gandhinagar, Gujarat
Tender Value
36 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
20 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gandhinagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Dg Set, Transformer, Vcb, Lt Panel, Mccbs And Allied Works At Area B At Af Station Wadsar

BOQ

Name of Work:- REPAIR/MAINT OF DG SET, TRANSFORMER, VCB, LT PANEL, MCCBs AND ALLIED WORKS AT AREA B AT AF STATION WADSAR
Sl. No. Item Description
1M & L for taking out underground cable of any size (4x16 Sq mm to 3.5x400 Sq mm) 1100 volt grade & bricks, tracing out the defects, rectify the same, making serviceable by removing/cutting U/S & burnt out part jointing with straight through joint of suitable size, testing with megger etc complete all as specified and directed by Engineer-in-Charge.Note :- Straight through joints will be measured and paid separately
2Relaying of serviceable cable retrieved from item No 01 after cutting into pieces of serviceable portion complete all as specified and directed by Engineer-in-Charge.
3LT Cable of size 3.5 x 400/300/240 Sq mm
4LT Cable of size 3.5 x 185/150 Sq mm.
5LT Cable of size 3.5 x 120/95 Sq mm.
6LT Cable of size 3.5 x 35/50/70 Sq mm.
7LT Cable of size 3.5 x 16/25 Sq mm.
8S & F in replacement Bus bar chamber, wall mounted 200 amp, 4 way current rating, factory , dust and vermin proof including bus bar of rectangular cross section with suitable size of copper strip supported on case epoxy insulator at suitable interval heat shrinkable sleeves with proper colour code 01 set of 04 strips, complete with grouting in wall/floor including PCC work for holding enclosure complete all as specified and directed by Engineer-in-Charge.
9M & L in replacement straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 3.5 core 25/35 Sq mm including complete testing after joint complete all as specified and directed by Engineer-in-Charge.
10M & L in replacement straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 3.5 core 50/70 Sq mm including complete testing after joint complete all as specified and directed by Engineer-in-Charge.
11M & L in replacement straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 3.5 core 95/120 Sq mm including complete testing after joint acomplete all as specified and directed by Engineer-in-Charge.
12M & L in replacementstraight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 3.5 core 150/185 Sq mm including complete testing after joint complete all as specified and directed by Engineer-in-Charge.
13M & L in replacement straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 3.5 core 240/300 Sq mm including complete testing after joint complete all as specified and directed by Engineer-in-Charge.
14M & L in replacement Heat Shrinkable cable jointing kit for 11 KV (earthed) grade cable for indoor termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of size 95 Sqmm including complete testing after joint complete all as specified and directed by Engineer-in-Charge.
15M & L in replacement Heat Shrinkable cable jointing kit for 11 KV (earthed) grade cable for outdoor termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of size 95 Sqmm including complete testing after joint complete all as specified and directed by Engineer-in-Charge.
16M & L for straight through of cable jointing kit for 11 KV(earthed) grade cable for straight through Hot shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of size 95 Sqmm including complete testing after joint complete all as specified and directed by Engineer-in-Charge.
17Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
18Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge.
19Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
20Supply and laying in replacement DWC HDPE pipe of SN4 category conforming to IS 14930 part I and II including all connected accessories like HDPE snap fit coupler with neoprene 'O' ring complete all as specified and directed by Engineer-in-Charge of following size:-
21DWC HDPE pipe 100 mm inner dia (for protection of 300/400 sqmm LT cable/95 sqmm HT cable) complete all as specified and directed by Engineer-in-Charge.
22DWC HDPE pipe 75 mm inner dia ( for protection of 185/240 sqmm UG cable) complete all as specified and directed by Engineer-in-Charge.
23DWC HDPE pipe 63 mm inner dia ( for protection of 150/120 sqmm UG cable) complete all as specified and directed by Engineer-in-Charge.
24DWC HDPE pipe 50 mm inner dia ( for protection of 95/70/50 sqmm UG cable) complete all as specified and directed by Engineer-in-Charge.
25DWC HDPE pipe 38 mm inner dia ( for protection of 35/25/16/10 sqmm UG cable) complete all as specified and directed by Engineer-in-Charge.
26M & L for boring of holes up to 80 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique complete all as directed by Engineer-in- charge.Note:- Pipe for protection of cable shall be measured and paid separately.
27S & F in replacement light grade GI tubing of 50 mm bore for cable protection in wall/trench complete all as specified and directed by Engr in charge.
28S & F in replacement light grade GI tubing of 80 mm bore for cable protection in wall/trench complete all as specified and directed by Engr in charge.
29Supplying and laying in replacement of XLPE insulated, PVC sheathed, armoured, heavy duty, aluminium conductor LT, 1100 Volts grade including taking out old/unserviceable underground cable XLPE insulated, PVC sheathed, armoured, heavy duty aluminium conductor LT 1.1 KV Volts grade cable, fixed on walls and trenches etc complete all as specified and directed by Engineer-in-Charge of the following size :-
3010 Sqmm 4 core
3116 Sqmm 4 core
3225 Sqmm 3.5 core
3335 Sqmm 3.5 core
3450 Sqmm 3.5 core
3570 Sqmm 3.5 core
3695 Sqmm 3.5 core
37120 Sqmm 3.5 core
38185 Sqmm 3.5 core
39Supplying and laying in replacement of XLPE insulated, PVC sheathed, armoured, heavy duty, aluminium conductor HT, 11 KV grade of 95 sqmm 3 core size including taking out old/unserviceable underground cable XLPE insulated, PVC sheathed, armoured, heavy duty aluminium conductor HT, 11KV grade cable, fixed on walls and trenches etc complete all as specified and directed by Engr -in -charge.
40M/L in replacement Cable route indicator CI disc of size 100 mm dia x 3 mm thick marked as \\"MES LT Cable\\" or \\"MES HT Cable\\" including angle iron pedestal and grouting complete all as specified and directed by Engr-in-charge.
41S&F MCCB in replacement with terminal connections complete of required size aluminium lugs etc complete all as specified and directed by Engr-in-charge of the followings size :- Make:- Legrand/L&T/Havells or equivalent as approved by GE
42MCCB TP 630 amp Adjustable type 50 KA.
43MCCB TP 250 amp Adjustable type 25 KA
44MCCB TP 400 amp Adjustable type 36 KA .
45MCCB TP 200 amp Adjustable type 36 KA .
46MCCB TP 160 amp Adjustable type 25 KA
47MCCB FP 630 amp Adjustable type 50 KA
48MCCB FP 400 amp Adjustable type 36 KA .
49MCCB FP 250 amp Adjustable type 25 KA .
50MCCB FP 200 amp Adjustable type 25 KA .
51MCCB FP 160 amp Adjustable type 25 KA
52MCCB TP 125 amp fixed type 16 KA
53MCCB TP 100 amp fixed type16 KA.
54MCCB FP 100 amp fixed type 16 KA.
55MCCB FP 125 amp fixed type 16 KA.
56MCCB FP 63 amp fixed type 16 KA.
57MCB TPN 63A, C Curve
58MCB TP 40 A,C curve
59S& F in replacement Aluminium lugs of sizes 300/185/120 Sqmm complete all as specified and directed by Engr-in-charge.
60S& F in replacement On load change over switch with sheet metal Enclosure 63 amp , 4 pole , Including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
61S& F in replacement On load change over switch with sheet metal Enclosure 100 amp , 4 pole Including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
62S& F in replacement On load change over switch with sheet metal Enclosure 125 amp , 4 pole , Including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
63S& F in replacement On load change over switch with sheet metal Enclosure 200 amp , 4 pole Including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
64S& F in replacement On load change over switch open execution 400 amp , 4 pole Including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
65S& F in replacement Aluminium lugs of sizes 95/70/50 Sqmm complete all as specified and directed by Engr-in-charge.
66S& F in replacement Voltmeter digital type 96 x 96 mm square, 0-500Volt including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
67S& F in replacement Ammeter Digital type 96 x 96 mm square , 0-200Amp, including suitable CT's Including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
68S& F in replacement Aluminium lugs of sizes 35/25/16/10 Sqmm complete all as specified and directed by Engr-in-charge.
69Supply and fix in replacement of APFC relay 8/6 stage, 144 x 144 size including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
70Supply and fix in replacement of CT Coil, 150/5 amp including all electrical connection and testing complete all as specified and directed by Engr-in-charge.
71M&L for servicing of APFC panel of any rating to maintain the power factor at optimum level ie above 0.95 & producing servicing certificate from authorised dealer complete all as specified and directed by Engr-in-charge.Note :- Additional parts, if required will be measured and paid separately.
72Supply and fix in replacement of contactor for 25 KVAR complete all as specified and directed by Engr-in-charge.
73Supply and fix in replacement of contactor for 15/20 KVAR complete all as specified and directed by Engr-in-charge.
74Supply and fix in replacement of contactor for 5/10/12.5 KVAR complete all as specified and directed by Engr-in-charge.
75Supply and fix in replacement of KVAR capacitor 5 to 10 KVAR complete all as specified and directed by Engr-in-charge.
76Supply and fix in replacement of KVAR capacitor 12.5/15/20 KVAR complete all as specified and directed by Engr-in-charge.
77Supply and fix in replacement of KVAR capacitor 25 KVAR complete all as specified and directed by Engr-in-charge.
78M & L for painting to steel surfaces of feeder pillar box with one coat of synthetic enamel paint including preparation of surfaces complete all as specified and directed by Engr-in-charge.
79M & L in replacement of Drop Out fuses (expulsion fuses) single pole, 11000 volt above 25 & up to 50 Amp complete all as specified and directed by Engr-in-charge.
80S & F Fuse Copper Wire 5/10 Amp of suitable gauge for HT incoming supply complete all as specified and directed by Engr-in-charge.
81M & L for maintenance & repairing/servicing of 1.1 KV, LT ACB panel, dusting, oiling , setting of over current and earth fault relay setting including complete testing complete all as specified and directed by Engr-in-charge.Note:- Additional parts ,if required will be measured and paid separately.
82M&L for Gas charging & pressure testing of SF 6 RMU 4/6 way installed in area B at 15 BRD complete all as specified and directed by Engr-in-charge.
83M & L for No Volt Coil for 630/800 Amp including all connections complete all as specified and directed by Engr-in-charge.
84M & L for servicing and maintenance of 11 KV HT VCB with relay testing and high voltage and relay setting corrections including complete testing complete all as specified and directed by Engr-in-charge.Note :- Additional parts, if required will be measured and paid separately.
85S&F in replacement Spring charging motor
86S&F in replacement BKR Auxiliary switch
87S&F in replacement Closing coil
88S&F in replacement Tripping coil
89S&F in replacement Insulation shrouds
90M & L for maintenance & servicing of 11 KV,HT RMU with checking complete all as specified and directed by Engr-in-charge following work:-(a) Load Break Switch:-(i) On-Off Operation Checking.(ii) Interlocking of the LBS.(iii) Hardware tightening of the mechanism(iv) Latch Roller Condition(v) LBS lever lubrication(vi) Aux Switch setting if unit is motorized(b) Circuit Breaker :-(i). On-Off Operation of CB.(ii). Tripper Setting.(iii). Cable Box Interlock of the CB,(iv). Pad Lock of CB.(v). Cam Setting.(vi). Reset spring setting.(vii). Lubrication to required parts.(viii). Neutral Catch Setting.(ix). Off to reset Wire setting.(x). Aux Switch Setting.
91M & L for Testing of 11 KV,HT RMU complete all as specified and directed by Engr-in-charge with following work:-(i) Relay Primary Injection test.(ii) Insulation Resistance.(iii) Contact Resistance.(iv) Tripper Coil resistance.(v) Battery Bank replacementNote for item Nos :- (i) The contractor should carry out servicing through authorised experience mechanic. (ii) Proper servicing certificate should be produced immediately after servicing .
92M&L for earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanised iron strip 25 x4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No.3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforce with welded steel wire baric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and directed by Engr-in-charge
93All as per item No. 51 above, but using copper plate 60 cm X 60 cm X 3.15 mm thick electrode and 20 X 3 mm copper strip as earthing lead including earth test point complete all as specified and directed by Engr-in-charge
94Supply and fix in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed by Engr-in-charge
95M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engr-in-charge
96M & L for testing of earthing resistance value with digital type earth tester at different locations of 15 BRD on Monthly basis up to the entire satisfaction of AF personnel & submitting the earth result complete all as specified and directed by Engr-in-charge.
97M&L for copper brazing (welding) at site to connect loop copper earthing strip of any size after tightening by nut, bolt, washer, check nuts of brass complete all as specified and directed by Engr-in-charge.Note :- Copper brazing shall be done upto 20 mtr height. Necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted for above item.
98M&L for GI brazing (welding) at site to connect loop GI earthing strip of any size after tighten by nut, bolt, washer, check nuts, complete all as specified and as directed by Engr-in-charge. Note :- GI brazing shall be done up to 20 mtr height. Necessary tool/plant and ladder required for working up to 20 mtr height shall be deemed to be included in the rate quoted for above item.
99M & L for tightening and fixing in position loose hanging copper/aluminium strip of any size on wall or building roof using new insulators of porcelain of approved size and fixing existing copper/aluminium strip on the same as existing complete all as specified and directed by Engr-in-charge.
100Supply and fix in replacement of Copper Strip of size 20 X 3 mm buried/laid in trenches/fixed on wall/tower etc complete all as specified and directed by Engr-in-charge.
101Supply and fix in replacement of Copper Strip of size 32 X 6 mm buried/laid in trenches/fixed on wall/tower etc complete all as specified and directed by Engr-in-charge.
102Supply & fixing Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. Complete all as specified and as directed by Engr-in-charge.
103Supply & Fix in replacement of ceramic supporter with nut bolts/screws for fixing of copper / aluminium strips / GI strips on walls etc complete all as specified and as directed by Engr-in-charge.
104S & F in replacement of first aid box containing medical kits with expiry date valid for 01 years complete all as specified and directed by Engr-in-charge
105M& L in replacement of test point terminal block made out of gun metal or phosphorous bronze of size 75x75x25 mm drilled & screwed including 3 hole,8 mm dia 25 mm long hexagonal head with nuts & washers complete all as specified and directed by Engr-in-charge
106S&F in replacement air termination, single pointed aluminium rod 12mm dia and 300 mm long complete all as specified and directed by Engr-in-charge.
107All as per item No 65.00 above, but copper rod 12 mm dia and 450 mm long complete all as specified and directed by Engr-in-charge.
108S & F in replacement of 40 mm bore GI tubing, light grade galvanized with all fitting and fixed to walls and ceilings or laid in floors for earthing strip protection complete all as specified and directed by Engr-in-charge.
109M & L for colour coding of earthing pit cover with the following colour:- Red for chemical earth pit. Yellow for conventional earth pit. The numbering/marking of earth pit will be in capital black colour and is to be done as directed by Engineer -in- Charge.
110M&L for coarse aggregates, grading l, 90 to 40 mm size or grading 3, 50 to 20 mm size granite for spreading on ground for Four/Two pole structure complete all as specified and directed by Engr-in-charge.
111M& L for industrial salt for earthing pit recharging complete all as specified and directed by Engr-in-charge.
112M& L For technical grade Magnesium Sulphate for earthing pit recharging complete all as specified and directed by Engr-in-charge
113Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-charge.
114M&L for PCC 1 : 3 : 6 type C1( Using 20 mm graded crushed stone aggregate) for foundation / concrete blocks / earthing chamber / chamber cover complete all as directed by Engineer-in-charge at site complete all as specified and directed by Engr-in-charge
115S&F in replacement of 15 mm bore GI tubing, medium grade galvanized with all fitting and laid in trenches complete all as specified and directed by Engr-in-charge
116S& F Flat twin core cable weather proof Aluminium Conductor of size 6 sqmm complete all as specified and as directed by Engr-in-charge.
117S & F in replacement of Glow sign board of size 5 feet x 4 feet x 8 inch thick (1640 mm x 1310 mm x 200 mm thick),made out of flex paper roll sheet on 25 mm x 25 mm x 2 mm thick anodised aluminium angle frame, including 4 nos. of 20 W LED lights fitting(internally to the glow sign board) including providing all internal wiring and main connection with 1.5 sqmm single core stranded copper conductor (length not exceeding 10 mtr), matter of board will be as approved by Engineer In Charge complete all as specified and directed by Engr-in-charge.
118Supply, install, testing and commissioning weather and vermin proof LT feeder pillar box (Panel board) factory fabricated outdoor type canopy top factory lock front and back opening totally enclosed made out of 3.15mm thick sheet metal enclosure of suitable size with angle iron frame of MS angle 50 X 50 X 6mm up to 1.5 mtrs length from ground level duly powder coated of size 800 (w) x 1000 (H) x 400 (D) mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and side locking arrangement consisting of sufficient Nos of circular cables entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc. inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15micron) grey hammer tone with one coat of including connecting with L.T armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium and LT panel should be CPRI approved and factory fabricated complete all as specified and directed by Engr-in-charge and consisting of the following :-(i) MCCB 160 Amp, 4 Pole(AC 415 Volt), 16 KA - 01 No (ii) 100 Amp MCCB, 4 Pole, 415V, 16 KA - 04 Nos, (Out going)(iii) AL bus bar min 300 Amp - 01 set(iv) LED lamp RYB - 01 Set(v) Internal wiring with copper conductor incl necessary lugs and thimbles - 01 Job(vi) Digital voltmeter 0-500V(vii) Digital ampere meter 0-200 Amp (viii) Space for 02 Nos of spare MCCB
119M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size up to 300 sqmm 3 core. The fault located equipment will be brought at site within 02 hours of Instruction received from Engineer-in-charge complete all as specified and as directed by Engineer-in-charge.
120Disconnecting terminals of LT cable and locating pin point fault in LT cable 1100 Volts grade of any size including to and from higher charge of special T & P all as directed by the Engineer-in-Charge.
121M & L for servicing of servo controlled voltage stabilizer 300/200 KVA, 415 volt including setting of input and output voltage complete all as specified and directed by Engr-in-charge.Note :- Spare required for replacement if any will be measured and paid separately.
122All as per item no 80 but for 100 KVA capacity complete all as specified and directed by Engr-in-charge.
123Supply only items for servo controlled voltage stabilizer of 300/150/100/75 KVA complete all as specified and directed by Engr-in-charge following spares parts :-
124Shunt Trip coil of any size
125Cut out PCB,3-phase
126Micro-controller PCB with connector
127control cabling with glass fuse
128Indication lamp, 22.5 mm dia, R - Y- B
129Push button,12.5 dia,R -Y-B
130Single phase , Synchronise AC motor, 10 KG
131RC network for 10 KG motor
132Sensing Transformer for Digital/analog control
133Aluminium Busbar of any size and any capacity.
134Stabiliser carbon Brush for Dimmer
135Supply & fixing in replacement spares of DG Set 160 KVA, Mahindra & Mahindra for its smooth operation & better performance complete all as specified and directed by Engr-in-charge of the following spare parts :-
136Oil Filter
137Diesel Filter
138Oil Pressure Gauge
139Air Clener Element
140Elbow Hump Hose
141Clamp
142Fuel Supply & Return Hose
143Radiator Hose Set
144Fan Belt
145Belt Aternator
146Fly Wheel Ring Gear
147Supply & fixing in replacement spares of DG Set 82.5 KVA, KIRLOSKAR GREEN for its smooth operation & better performance complete all as specified and directed by Engr-in-charge of the following spare parts:-
148Oil Filter
149Diesel Filter
150Oil Pressure Gauge
151Air Cleaner ( Outer )
152Air Cleaner ( Inner )
153Fan Belt
154Uniball Joint
155Thermostate
156Hose Diesel
157Diesel Filter Pump Hose
158Supply & fixing in replacement spares of DG Set 62.5 KVA, KIRLOSKAR for its smooth operation & better performance complete all as specified and directed by Engr-in-charge of the following spare parts :-
159Oil Filter
160Diesel Filter
161Oil Pressure Gauge
162Air Cleaner ( Outer )
163Air Cleaner ( Inner )
164Fan Belt
165Uniball Joint
166Thermostate
167Hose Diesel
168Diesel Filter Pump Hose
169Supply & fixing in spares replacement of DG Set 30 KVA, Mahindra & Mahindra for its smooth operation & better performance complete all as specified and directed by Engr-in-charge of the following spare parts:-
170Oil Filter
171Diesel Filter
172Oil Pressure Gauge
173Air Cleaner ( Outer )
174Air Cleaner ( Inner )
175Fan Belt
176Uniball Joint
177Thermostate
178Hose Diesel
179Diesel Filter Pump Hose
180Supply & fixing in replacement spares of DG Set 20/15 KVA, Mahendra & Mahendra / Crompton Greaves for its smooth operation & better performance complete all as specified and directed by Engr-in-charge of the following spare parts:-
181Oil Filter
182Diesel Filter
183Oil Pressure Gauge
184Air Cleaner ( Outer )
185Air Cleaner ( Inner )
186Fan Belt
187Uniball Joint
188Thermostate
189Hose Diesel
190Diesel Filter Pump Hose
191Servicing for DG Set 160 KVA Capacity, drain out engine oil from sump, cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement of worn out spare parts for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed by Engr-in-charge of the following worn out spare part:-
192Diesel Filter With O Ring
193Oil Filter With O Ring
194Super Bypass Filter With O Ring
195Air Cleaner Element
196Servicing for DG Set 82.5 KVA Capacity, drain out engine oil from sump, cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed by Engr-in-charge following worn out spare parts:-
197Diesel Filter With O Ring
198Oil Filter With O Ring
199Super Bypass Filter With O Ring
200Air Cleaner Element
201Battery lead
202Servicing for DG Set 62.5 KVA Capacity, drain out engine oil from sump, cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed of the following worn out spare parts:-
203Diesel Filter With O Ring
204Oil Filter With O Ring
205Super Bypass Filter With O Ring
206Air Cleaner Element
207Battery lead
208Servicing for DG Set 30 KVA Capacity, , drain out engine oil from sump, cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement of following worn out spare parts for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed engineer - in- Charge of the following worn out spare part:-
209Diesel Filter With O Ring
210Oil Filter With O Ring
211Super Bypass Filter With O Ring
212Air Cleaner Element
213Servicing for DG Set 20/15 KVA Capacity, Make:- Mahindra & Mahindra/ Crompton Greaves drain out engine oil from sump, cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed engineer - in- Charge of the following worn out spare parts :-
214Diesel Filter With O Ring
215Oil Filter With O Ring
216Super Bypass Filter With O Ring
217Air Cleaner Element
218Battery lead
219Supply and connecting in repair of battery 130 Ah 12 Volt, maintenance free heavy duty with battery terminals and copper lead for +ve and -ve ends with complete fixing and testing complete all as specified and directed Engineer - in- Charge.
220Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 125 KVA complete all as specified and directed Engineer -in- Charge.
221Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 125 KVA complete all as specified and directed Engineer - in- Charge
222Supply and filling distilled water for inside the battery and charge properly to maintain battery voltage for 15 KVA to 125 KVA DG Sets complete all as specified and directed Engineer - in- Charge
223Supply, and connecting in repair of battery 90 AH 12 Volt, maintenance free heavy duty with battery terminals and copper lead for +ve and -ve ends with complete fixing and testing complete all as specified and directed Engineer - in- Charge
224M&L for dismantling of complete radiator assy form engine and taking out all, descaling, rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete and refixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of complete all as specified and directed Engineer - in- Charge of the following DG set :-
225For DG Set capacity 10 KVA to 30 KVA
226For DG Set capacity 62.5 KVA to 82.5 KVA
227For DG Set capacity 160 KVA
228Taking out old burnt out Automatic voltage regulator from DG set alternator and S&F suitable capacity of automatic voltage regulator complete testing and checking voltage regulation of the DG set after full load position of DG set for its satisfactory performance complete all as specified and directed by Engineer-in-Charge of the following DG set :-
229For DG Set capacity 10 KVA to 30 KVA
230For DG Set capacity 62.5 KVA to 82.5 KVA
231For DG Set capacity 160 KVA
232M&L for preparation of old painted surfaces of the DG set and fuel tank of following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed by Engineer-in-Charge of the following DG set.Note :- Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemes grey(iii) Fly wheel guard - Red(iv) Radiator - Black
233For DG Set capacity 10 KVA to 30 KVA
234For DG Set capacity 62.5 KVA to 82.5 KVA
235For DG Set capacity 160 KVA
236M&L taking out alternator from existing position after disconecting all electrical connection and de-coupling from engine assy and transporting to repair workshop, dismantling the alternator taking out stator/rotor/excitor coil, rewinding and re-varnishing the complete coil heating up for dehydration of moisture cleaning servicing greasing of complete alternator including replacement of bearing re-assembling the alternator complete and transporting to site , refixing the alternator on its existing position including coupling with engine assy connection of cable complete all as specified and testing for its satisfactory performance all as specified and directed by Engineer-in-Charge:-
237For DG Set capacity 10 KVA to 30 KVA
238For DG Set capacity 62.5 KVA to 82.5 KVA
239For DG Set capacity 160 KVA
240M&L for Dismantling the self starter assy from engine and repair servicing of starter by replacing old work out bearing bushing armature coil solenoid switch etc. re-assembling the complete starter fixing the same on engine and testing for its satisfactory performance complete all as specified and directed by Engr-in-Charge :-
241For DG Set capacity 15 KVA to 30 KVA
242For DG Set capacity 62.5 KVA to 82.5 KVA
243For DG Set capacity 160 KVA
244M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil partial complete and refixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-
245For DG Set capacity 15 KVA to 30 KVA
246For DG Set capacity 62.5 KVA to 82.5 KVA
247For DG Set capacity 160 KVA
248M&L for visit of DG SET for checking of serviceability report and submitted at office complete all as specified and directed by Engr-in-Charge of the following DG set:-
249For DG Set capacity 10 KVA to 30 KVA
250For DG Set capacity 62.5 KVA to 82.5 KVA
251For DG Set capacity 160 KVA
252S&F in repair DOL Starter for 7.5 HP three phase thermal overload relay (12- 18 A) and mechanical interlock, phase failure relay Dry run protection, Overload relay complete all as specified and directed by Engr-in Charge.
253S&F in repair DOL Starter for 15 HP three phase thermal overload relay (12- 18 A) and mechanical interlock, phase failure relay Dry run protection, Overload relay complete all as specified and directed by Engr-in Charge.
254S&F in repair 12 Volt 10 Amps Auto charge Battery charger with fitment complete with necessary cable connection as required for fixing complete all as specified and directed by Engineer-in-Charge.
255S&F in repair 24 Volt 10 Amps Auto charge Battery charger with fitment complete with necessary cable connection as required for fixing complete all as specified and directed by Engineer-in-Charge.
256Supply, install, testing & commissioning in replacement of faulty TC contactor for DG Set up to 30 KVA to 62.5 KVA, As per existing model 415 Volt rated capacity with coil voltage and connected relays all as specified and directed by E-in-Charge
257Supply, install, testing & commissioning in replacement of faulty TC contactor for DG Set 82.5 KVA to 160 KVA, As per existing model 415 Volt rated capacity with coil voltage and connected relays complete all as specified and directed by Engr-in Charge.
258Supply, install, testing & commissioning in repairs controller - Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connection good and renewed for up to DG set 200 KVA as per existing make complete all as specified and directed by Engr-in-charge.
259Supply, install, testing & commissioning in repairs controller - Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connection good and renewed for DG set 10 KVA to 125 KVA as per existing make complete all as specified and directed by Engr-in-charge.
260Supply,install,testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge.
261S&F in repair solenoid switch as per existing sample for 10 KVA to 160 KVA DG set complete all as specified and directed by Engr-in Charge.
262M&L for servicing of AMF Panels for DG Set including internal wiring connections, relay setting, setting of pick up time for auto start of DG Set, arranging the doors of panels by welding to the compartment, rearranging and tightening of lugs for cable connections, cleaning dust by vacuum cleaner, replacing the contactors for Main/DG Supply if found unserviceable under the respective item of this schedule testing the DG Set for auto/manual start by running the DG Set for 01 Hrs complete all as specified and directed by Engr-in Charge.Note :- The additional cost for internal wiring, PCB service, lugs and programming of the ckt will be included in this item.
263Comprehensive maintenance consisting of repair, maintenance and servicing including replacement of spares for electrically operated overhead travelling EOT cranes, single/double girded, gear type with electric motor for long travel, cross travel, hoisted creap, control panels, protective panels, gear box, gantry rail, main switches, resistance coil, wire ropes, rope drum, brake control, cable and switches , Servicing Break drum cleaning , all electrical connection checking & connecting. Lubricating of all moving parts, cleaning of DSL, proper alignment of cable trolley, festoon cable system etc. EOT crane of Capacity 05 Ton , Double Girder in the P& AE Hanger of Area B complete all as specified and directed by Engr-in Charge of following spare parts:-
264Limit switch for LT/CT Make Speed-O-control
265Brake lining 6mm
266Brake Pad
267Hydraulic brake for Hoist
268Variable Frequency drive (VFD) For LT/ CT Motor Make - Yaskara/Mistubishi
269Cable trolley for DSL
270Over Load Relay for CT/LT Make -Siemens/L&T
271Over Load Relay for Hoist Make -Siemens/L&T
272Brush holder assembly incl carbon brush
2733 Pole Power contactor 25A L&T/ Havells
274Single Phase Advance Circuite Breaker, Over/Under Voltage Protector
275Magnetic Coil 100mm
276Steel wire rope 12mm Make Usha Martin
277Gear Oil C-320 Grade for LT/CT /Hoist
278Transformer oil for brake thruster
279Muti speed radio remote control
280Control Push button for NO/NC
281LT PVC insulated and PVC sheathed copper conductor cable 2.5 sqmm 10 core for pendent
282M & L for disconnecting and taking out the defective electric motor from the cranes, transporting to workshop for replacement of burnt out winding with existing gauge super enamelled copper wire including insulating paper and varnishing and re-fixing motors to crane after testing, up to 3 HP motor complete all as specified and directed by Engineer-in-Charge.
283Load testing of EOT Cranes of capacity 5 Ton installed at different locations mentioned as per item nos107 above, by hiring load (RCC cubes ) 05 Ton capacity in 3 Stages (50% ,100% and 150% ) including suitable transport, cranes and safety measures required for loading and unloading weight and submitting the test report in specific forms duly signed by testing authority complete all as specified and directed by Engineer-in-Charge.
284S&F Cable with 1 core x 16 Sqmm copper conductor PVC round sheathed (flexible) industrial cable complete all as specified and directed by Engineer-in-Charge.
285M & L for disconnecting and removing outdoor transformer after disconnecting HT/LT cable terminals connections and lowering down from plinth/platform structure of 250-500KVA capacity complete all as specified and directed by Engineer-in-Charge.
286M & L for opening the top cover/lid for periodical maintenance such as cleaning of transformer core, cleaning of oil tank to remove sludge deposit etc. of 250-500 capacity complete all as specified and directed by Engineer-in-Charge.
287Transportation of transformer/Voltage Stabiliser/DG Set- to nearest workshop fo repair/replacement of transformer/Voltage Stabiliser/DG Set- winding and return back for installation in its original position / location after repairing from workshop up to 500 KVA capacity (Rate is inclusive only transportation, T&P and manpower) complete all as specified and as directed by Engineer-in-charge.
288Shifting of serviceable transformer/Voltage Stabiliser/DG Set- up to 500 KVA from MES store yard / sub-stn (indoor / outdoor) for installation in place of unserviceable transformer and back after replacing with repaired transformer up to 500 KVA complete all as specified and as directed by Engineer-in-charge
289Rewinding of HT coils with super enamelled copper wire / strips DPC / super enamelled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing / insulation material in each layer of winding, Baking the core assembly with the help of oven duly varnishing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT / LT bushing studs & lead extension(replacing studs if damaged) and closing the tank top cover by fixing nuts, bolts and washers (Top cover gasket will be measured and paid for separately) complete all as specified and as directed by Engineer-in-charge.
290Rewinding of LT coils with super enamelled copper wire / strips DPC / super enamelled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing / insulation material in each layer of winding, Baking the core assembly with the help of oven duly varnishing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT / LT bushing studs & lead extension(replacing studs if damaged) and closing the tank top cover by fixing nuts, bolts and washers (Top cover gasket will be measured and paid for separately) complete all as specified and as directed by Engineer-in-charge.
291M & L for re-arranging the top core over coils in proper manner after proper cutting out & leaking including fixing of top channel soldering in between coils as necessary and brazing of star delta connection with tap changer for any size of transformer complete all as specified and as directed by Engineer-in-charge.
292S&F in replacement transformer Bush rods brass as per existing dia/size of HT/LT side including set of brass,washer,nut & bolt etc for indoor / outdoor transformer complete all as specified and as directed by Engineer-in-charge of following sizes:-
293100-200KVA
294250-500 KVA
295S&F in replacement porcelain insulating bush of transformer HT 11 KV conical bush / gasket for indoor / outdoor size up to 500 KVA complete all as specified and as directed by Engineer-in-charge.
296S&F in replacement silica gel breather assembly having iron cap at top & bottom and tighten with suitable size of nuts & bolts filled with silica gel for size of transformer 100KVA to 500 KVA all as specified and directed by Engineer-in-charge.
297S& F in replacement refilling of silica gel in existing serviceable breather assy all as directed by Engineer-in-charge. Please Enable Macros to View BoQ information
298S& F in replacement refilling of silica gel in existing serviceable breather assy all as directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58259552
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36 Lakhs
LAST DATE 19-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Dg Set, Transformer, Vcb, Lt Panel, Mccbs And Allied Works At Area B At Af Station Wadsar
Basic Detail
Tender No 8519/26-27/E8
Bidding Type Tender
Location
City Gandhinagar
State Gujarat
Key Dates
Publish Date 29 Oct 2026
Submission Date 19 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 36 Lakhs
Tender Fee 500
EMD 72000
Exemption Available
Document List
26b1570a-b2ae-4a06-be14-387959c55415.html
BOQ_893048.xls
Tenderdocument8519.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

26b1570a-b2ae-4a06-be14-387959c55415.html

xls

BOQ_893048.xls

pdf

Tenderdocument8519.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender