Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #58259550

Tender For Repair/Replacement Of Seamless Water Pumping Mains Of Various Sizes From P-3, P2 And Certain Other Works Under Ge Kasauli

Issued by Statutory Bodies & Commissions/Committees · Solan, Himachal Pradesh
Tender Value
46 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
0 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Seamless Water Pumping Mains Of Various Sizes From P-3, P2 And Certain Other Works Under Ge Kasauli

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-Nov-2026

BOQ

Name of Work:- REPAIR/REPLACEMENT OF SEAMLESS WATER PUMPING MAINS OF VARIOUS SIZES FROM P-3, P2 AND CERTAIN OTHER WORKS UNDER GE KASAULI
Sl. No. Item Description
1Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed.
2Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed.
3Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
4Dismantling and taking out old u/s worn out MS/CI/GI pipe line flanged type 150 mm bore including fittings complete with nuts, bolts, washers and gaskets etc and removing from the site complete all as specified and as directed by Engineer-in-charge. Note:- New pipes shall be laid first at spring area and old ones to be taken out later.
5Supplying, laying, jointing in replacement and testing hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 164.22 mm, with nominal wall thickness 7.11 mm and weight 28.26 Kg/ mtr, including short pieces as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- (i) Excavation Earth work, PCC, seamless pipe fittings, MS flanges & flanged joints shall measured and paid for separatly under relevant items. (ii) Work will be carried out in piecemeal loacations experienced based on break downs and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge. (iii) Any other expenses including permision from state authorities are included under this item.
6Material & labour for MS Flange of inner dia 150 mm (outer dia 164.22mm) and 280 mm outer dia of thickness 25.3 mm having 8 drilled holes complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified. and directed.
7Supply and fixing of joint for 150 mm nominal bore pipes, comprising one 5.0 mm thick steel-reinforced compressed asbestos fibre gasket, including 8 Nos. M38 nuts and bolts (each bolt not less than 25 mm in diameter and 125 mm in length), and 2 Nos. 5 mm thick washers per joint, suitable for pipes/fittings/bends, complete all as specified and directed.
8Supply And Fixing in replacement of Air release valve DI Single Chamber, Tripple Action with Stainless steel floating And working parts & Fb Expoxy coating in PN1.6 of size 150mm conforming to IS 14845 incl 8 Nos 19.05mm dia ,100mm long Nut ,bolts, 2 nos washer incl 3 mm thick gasket of required size and shape complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified and directed.
9Supplying, laying, jointing in replacement and testing of Tees, suitable length and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 164.22 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed.
10Supplying, laying, jointing in replacement of Seamless bend ( 90 Degree, 45 degree, 60 degree), suitable length and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 164.2 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed.
11Supply And Fixing in replacement and testing of high pressure, heavy duty cast steel sluice valve, nominal size 150mm, conforming to API 600, classs 600, Suitable to hydrostatic test pressure for body 156 KG /sq cm & for seat 115kg/cm, both ends flanged in existing line, after removal of old unservicable gate valve without damaging to exting pipe line complete all as specified and diected. NOTE:- Suitable size MS Flange for exiting pipe line, joints and joining materials shall be including under this item
12Supply And Fixing in replacement and testing of high pressure, heavy duty type cast steel Non Return,valve/ check valve, nominal size 150mm, PN 10 conforming to BS 1868, classs 600, Suitable to hydrostatic test pressure for body 156 KG /sq cm & for seat 115kg/cm, both ends flanged in existing line, after removal of old unservicable gate valve without damaging to exting pipe line complete all as specified and diected. NOTE:- Suitable size MS Flange for exiting pipe line, joints and joining materials shall be including under this item.
13Dismantling and taking out old u/s worn out MS/CI/GI pipe line flanged type 150 mm bore including fittings complete with nuts, bolts, washers and gaskets etc and removing from the site complete all as specified and as directed by Engineer-in-charge.
14Amount of credit of Rs. 358012.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58259550
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Seamless Water Pumping Mains Of Various Sizes From P-3, P2 And Certain Other Works Under Ge Kasauli
Basic Detail
Tender No GEK-86/2026-27
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 11 Nov 2026
Submission Date 18 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 46 Lakhs
Tender Fee 500
EMD 92000
Exemption Not Available
Document List
1609a180-f1fa-49d1-a64d-61fb5039b768.html
BOQ_892813.xls
TENDERDOCUGEK862627.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

1609a180-f1fa-49d1-a64d-61fb5039b768.html

xls

BOQ_892813.xls

pdf

TENDERDOCUGEK862627.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender