Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #58257777

Tender For Special Repair Bldg No T-166 Ors Single Living Accomodation At A Veh Platoon 612 Eme Battalion At Pokaran Military Stn

Issued by Statutory Bodies & Commissions/Committees · Jaisalmer, Rajasthan
Tender Value
9.70 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
6 days left
EMD
19500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Bldg No T-166 Ors Single Living Accomodation At A Veh Platoon 612 Eme Battalion At Pokaran Military Stn

BOQ

Name of Work:- SPECIAL REPAIR BLDG NO T-166 ORs SINGLE LIVING ACCOMODATION AT A VEH PLATOON 612 EME BATTALION AT POKARAN MILITARY STN
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
2M & L for Granite of black / green / imperial red (colour as approved by Accepting Officer) of any type machine cut as in shelves/steps/counter tops, 20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick / rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive for fixing on unpolished kota stone slabs and including rubbing, cutting and mirror type polishing and bull nose on exposed sides complete all as specified .Note : Single piece should be used in steps/cills/jambs/shelves or equivalent as approved by accepting officer .
3M&L for Vitrified Ceramic tiles in light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc. over & including 15 mm thick screed in cement mortar (1:6) over and pointed in white cement with pigment to match the colour of tiles complete all as specified.
4M&L for Glazed ceramic glossy finish tiles coloured in vertical surface 450X350X7mm in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified.
5Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed.
6M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate used with M sand for levelling course for consolidated thickness 40 mm all as per the requirements all as directed by Engr-in-Charge.
7M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only)
8Supply only integral Waterproofing compound.
9M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltr/Sqm by forced all as specified and as directed , Four course roof treatment consist of as under :-(i) Applying one coat of bituminous primer conforming to IS-3384 @0.3 Ltr per sqm (ii) Laying of APP based membrane as specified thickness and weight (iii) Applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm
10Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water all as specified
11M & L for rendering 10mm thick ready mix plaster on internal wall by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed.
12M & L for Cement plastering 15mm( thick in two layers -first layer 10mm thick with ready mix plaster and outer layer 5mm thick ready mix water proof plaster) on outer walls by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS- 2250-1981 and shall confirm 28 days compressive strength 10-15 MPA, bulk density 1600-1800 kg/cum and pull out bond strength->0.5 MPA complete all as specified and directed
13M & L for rendering 5 mm thick ready mix self curing plaster on ceilling by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed.
14M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over one coat of 3mm thick wall care putty including one coat of primer all as specified & directed by Engineer-in- Charge.
15M&L for preparation of newly plastered surfaces of ceiling and applying two coat of acrylic distemperDistempering with 1st quality having VOC content less than 50 gms/ itre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work. all as specified & directed by Engineer-in- Charge.
16Complete preparation new surfaces of walls and preparation of surfaces (external faces) of walls and applying two coats of external weather proof paint of Apex or equivalent over a coat of primer (self coat) complete all as per manufacturers instructions, complete all as per specified and directed.
17M&L for preparing old plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified & directed by Engineer-in-charge.
18M&L preparation of old plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
19M&L for preparing old plastered or unplastered distempered surfaces of wall and applying one coat of distemper oil emulsion complete all as specified & directed by Engineer-in-charge.
20Taking down door/windows/ventilators chowket or frame incl shutter area n exc 1.50 sqm
21Taking down chowkhats or frames door/windows/ventilators (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
22Stainless steel tubing of 25 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fency type, stops fixed with ss screws etc all as specified & directed as in repair .Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered as approved by Engr-In-Charge.
23Providing and fixing powder coated 50 microns extruded aluminium in 3 Tier Track Sliding Windows/glazing, with frame of section 100x44-45x1.30mm, track of size 100x38.10x1.30 & shutters made of size 32x18x1.3mm, with and including 4mm thick tinted sheet glass selected quality fixed in 2 shutters and stainless steel wire gauge 0.36mm nominal dia of wire and average width of aperture 1.40mm in one shutter and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size and also including powder coated 150mm handle with built in locking system for each leaf complete all as specified.
24S & F Factory made ISI marked WPC flush door shutters 35mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and including supply and fixing following items As approved by Engr-In-Charge :(a) Stainless Steel (304 Grade) Finished Butt HinAGEs 125mm - 3 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leafMake (Aluminium Sections) : Jindal/Valco/Galco/Hindalco or equivalent as approved by Engr-In-Charge
25S & F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-I section 8 clause 8.20 (a) kiln seasoned and chemically pressure treated all as specifeid including stainless steel 304 grade wire cloth ( 0.36mm nominal dia of wire and averaAGE width of aperture 1.40 mm ) and incl supply and fixing following items:-(a) Stainless Steel (304 Grade) Finished Butt Hinages 125mm - 3 nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x3000mm - 1 nos per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos per leaf
26Demolition of cement concrete unreinforced in groundfloors and pavings not exc 15cm thickness below or above ground level etc all as specified and as directed by Engineer-in-Charge.
27M&L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection and surface finished even and smooth w/o using extra cement as specified & directed by Engineer-in-Charge.
28M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate used with M sand for levelling course for consolidated thickness 40 mm all as per the requirements all as directed by Engr-in-Charge.
29M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick,with grey pigment cement and pigments set, jointed and pointed in neat cement slurry in floors.
30M&L for Providing, cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in copings, kerbs etc including necessary formwork complete all as specified and directed by Engineer-in-Charge.
31Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified.
32M&L for squared rubble walling, Jodhpur type brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed.
33M&L for squared rubble walling, Jodhpur type brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed. but except stone
34Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge.Note: Contractor shall use Fine aggregate (M Sand) for cement concrete and mortar in masonary
35Taking down carefully existing point wiring of any description light, fan,sockets,bells etc) complete including fittings such as terminal boxes, switches, sockets, ceiling rose, lamp holders, brackets sketch fittings, pendants, fan regulartors and making good the disturbed surfaces, walls, floors etc. all as directed by EIC
36Taking down old unsv MCB DB / main switch incl MCBs / MCCBs complete all as specified and directed
37M&L point wiring complete with 1.5 Sqmm single core PVC insulated FRLS cable 1100 Volts grade multistranded copper conductor drawn through in PVC Conduit concealed on underground stone / brick, masonry walls, roofs floors etc including MS terminal boxes fabricaterd out of 1.12mm thick MS sheet sunk type / surface type and laminated top sheet of 2mm thick for housing switches sockets, regulators etc including provn of 1.5 sqmm dia copper conductor for earth wire connected to common dolly for One light point / Fan point /Exhuast Fan / Bell point controlled by one 5 Amps One way switch and making good surfaces all as specified and directed by Engineer-in-Charge.
38All as per Item No. 04 but for one 3 pin 5/6 Amps switch socket outlet on same board
39All as per Item No. 04 but for one 3 pin 5/6 Amps switch socket outlet on independent board
40All as per item No. 04 above but wiring with 4.0 Sq mm and 4.0 sqmm for earth continuity for 3 pin 15/16 Amps switch socket combination
41M&L switch Modular switch 1 way 6A, 1 module single pole complete all as specified and directed.
42M&L Modular switch 1 way 16A, 1 module single pole confirming to IS 3854 : 1997 complete all as specified and directed.
43M&L Modular Socket 6A 2/3 pin combined 2 module outlet, multipurpose complete all as specified and directed.
44M&L Modular Socket 16/6A 3 pin combined 2 module outlet, multipurpose complete all as specified and directed.
45S&F Electronic type Modular fan step regulator 120W, 2 module AC 240 V all as specified and directed
46M&L Modular white cover plate with frame ( both inner & outer plate cover) 1 module
47M&L Modular white cover plate with frame ( both inner & outer plate cover) 3 module
48M&L Modular white cover plate with frame ( both inner & outer plate cover) 6 module
49M&L Modular white cover plate with frame ( both inner & outer plate cover) 8 module
50M&L lamp holder insulated body with back plate suitable for battern fittings
51supply and fix LED Lamp Retro fit type 9 watts 230 V and all as specified by Engr-in-charge
52S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminais all as specified
53S&F Sheet Modular metal enclosure DB SPN 240 Volts 12 Way single door type with 200 Amps busbar for fixing of MCBs
54S&F MCB Single pole and neutral, 40A, 240 Volts AC all as specified
55S&F MCB Single pole, 5-32A, 240 Volts AC all as specified
56M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead all as specified
57Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
58Modular metal flush box 1 module all as specified and directed.
59Modular metal flush box 3 module all as specified and directed.
60Modular metal flush box 6 module all as specified and directed.
61Modular metal flush box 8 module all as specified and directed.
62S & F 15 Watt LED Bldg security light with a nominal system . The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 15W (including driver) pre wired fitted on and including two Nos PVC block of suitable l size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm size and testing complete including LED lamp, including taking down old unserviceable fitting any type complete all as specified and as directed.
63Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58257777
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.70 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Bldg No T-166 Ors Single Living Accomodation At A Veh Platoon 612 Eme Battalion At Pokaran Military Stn
Basic Detail
Tender No 8417/E8
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 29 Oct 2026
Submission Date 16 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value 9.70 Lakhs
Tender Fee 500
EMD 19500
Exemption Available
Document List
7dc9200b-df63-487a-aecc-8831c3817ab3.html
appxc.pdf
BOQ_893035.xls
credit.pdf
tenderl.pdf
tenderll.pdf
tenderlll.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

7dc9200b-df63-487a-aecc-8831c3817ab3.html

pdf

appxc.pdf

xls

BOQ_893035.xls

pdf

credit.pdf

pdf

tenderl.pdf

pdf

tenderll.pdf

pdf

tenderlll.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender