Science and Technology Government Departments Closing in 14 days TDR #58254615

Tender For Provision Of Electronic Interlocking System With Digital Axle Counter (Msdac) In Station Yard, Along With S&T Service Building At Hdn Route Station Hindaun (Han) On Kota Division

Issued by Government Departments · Ghaziabad, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Nov 2026
14 days left
EMD
3.28 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Electronic Interlocking System With Digital Axle Counter (Msdac) In Station Yard, Along With S&T Service Building At Hdn Route Station Hindaun (Han) On Kota Division , Supply Of Powder Coated 1 Way Main Cable Termination Rack Complete With Scaffolding, Fixtures & Accessories Including Square Bars For Mounting 8-Way Terminal Blocks/Wagos, Ladder, String Rods, Frame, Base Assembly, Insulators, J-Bolt, Nut/Bolts & Fasteners, Phenolic Laminated Sheet Board Etc. Siemens Type & As Per Extant Practice On W.C. Rly. Typical Part List As Per Annexure K For 3-Way And Annexure L For 2-Way Attached And Rack Arrangement As Per Wcr Drg. No. S&T Eqpt. Bldg/2013/Pt. 1/4 And Rack Plan As Approved By Engineer Incharge. , Supply Of Powder Coated Relay Rack Assembly Complete With Scaffolding, Fixtures And Accessories Including Ms Bars For Fixing Of Relay Plug Board, String Rods, Fuse Strips With Bracket, 11-Way Bus Bars With Cover And Mounting Brackets ,Runway For Cable/Wires, Frame Base Assembly With Idf Pillar Etc. Siemens Type & As Per Extant Practice On W.C. Rly. Typical Part List As Per Annexure J Attached And Rack Arrangement As Per Wcrdrg. No. S&T Eqpt.Bldg/2013/Pt. 1/4 And Rackplan As Approved By Engineer Incharge. , (I) Supply Of 4 Conductor Disconnect Terminal Block With Test & Measurement Facility, With Screw Less, Spring Cage Clamp Connections Suitable For 0.08 To 2.5 Sq.Mm Conductor With Current Capacity Of 16 Amps As Per Rdso Spcn. No. Rdso/Spn/189/2004 Ver. 3.0 Or Latest. , (Ii) Supply Of End Plate Compatible To Above Screwless Terminals. The End Plates Shall Be Of Different Colour Than That Of Disconnect Terminal Blocks. , (Iii) Supply Of Din Rail Of Dimension 35Mm X 7.5Mm, 1 Mm Thickness, 1Mtr Length, Slotted Compatible To Above Terminals. , Iv) Supply Of End Stop 10Mm For Above Din 35 Rail. , Supply Of Dual Fuse Alarm System / Fuse Fail Indication Cum Monitoring And Automaticchange Over System For Vitalfuses As Per Draft Specificationno. Rdso/Spn/209/2012 Ver2.0 Or Latest. This Consists Fuses Of Different Ratings As 0.6A, To 16A. Number Of Fuses Of Ratings To Be Decided As Per Site Requirent And Engineer In-Charge. (01 Numbers= 01 Fuse).Spares To Be Provided As Per Rdso Spcifications. , Supply Of Insulation Mat For Electrical Purpose 2.2 Mm Thick Size 2M X 1M X Suitable For 3.3 Kv To 11Kv (Class B) Conforming To Is- 15652-2006 , Supply Of Protocol Converter For Interface The Data Logger And The electrical installation System Suitable For Above Data Logger. Any Other Equipment/Connector/Cable Required To Connect electrical installation To Datalogger Wil Have To Be Supplied By Contractor At His Own Construction , Supply Of Automatic Media Change Over Of Modem Working On Redundant Channels For Data Transmission On Ofc/Quad/Microwave Radio. Qty.01 Pair & Modems For Ufsbi (For Use With Secondary Media Ofc/Quad) Qty. 01 Pair. Make Des(Delron Elecronic System Only). , Supply Of Modem Compatible With Existing Ufsbi System Of Des Make Or Similar As Per Specn No. Irs:S-105/2012 (Ver.0) Or Latest Suitable To Interface With Ofc Fiber (Optical Modem) For Deltron Make Ufsbi Provided In Kota Division. , Supply Of Ufsbi Event Logger With E1 / Dark Fiber Connectivity From Site To Control Room. , Preparation In Autocad, Fabrication On Board, Supply & Screen Printing Of Swrd, Track Bonding Plan, Rsp Board On White Formica Of 1200X600x3mm As Per Instruction Of Site Engineer. Proportionate Payment Will Be Made If Size Of Board Get Increased Or Decreased.Rate = Per Board Item , Supply Of Self Supporting Foldable Ladder Heavy Duty Made Of Aluminium C Section Size 66 Mm X 31 Mm X 3 Mm And Climbing Steps Made Of Aluminium 112 Mm Wide (4.5 Inch) On Front Side & Back Side (1 Inch) , Having Service Platform At The Top Size 16 Inch X12 Inch & Rubber Shoes Are Fitted At Four Legs. Size 6 Feet Height Make: Neelkamal, Godgej Or Reputed Make. , Supply Of 48 Fiber Ofc Jointclosure Similar To Specification No.Rdso/Spn/Tc/68/2014 Rev 1.0 Orlatest. , Supply Of Thermo Shrink Jointing Kit For Jointing Underground 0.9 Mm Dia. Cond. 4/6 Quad Cables As Per Specn No. Irs: Tc-77/2012 (Rev.3.0) With Amend. 1, 2 & 3 Or Latest. , Supply Of Main Signal Post 140 Mm Outer Dia 4.6 Mtr Length As Per Specification No. Irs: S-6 With Latest Amendment. , Supply Of Cast Iron Main Signal Surface Base 140Mm As Per Specification No. Irs: S-10 And Drg No. S-2011/M With Latest Amendment, With Cls Ladder Assembly Complete And Ladder Base For Cls Signal 3.6 Mtrs/ 4.6 Mtrs./ 5.6 Mtrs. Long As Per Rdso Drg. No. Sa-23150/23153/23156 (Adv.) With Latest Amendment. This Also Include, Signal Front & Back Staging Complete Assembly For Cls Unit As Per Drg. No. Rst/11413. , Supply Of Non Metallic (Frp) Colour Light Signal Housing Multi Unit Type For Railway Signaling Suitable For Re Area Two Aspects. Complete Without Lenses, Lamps And Signal Transformer As Per Rdso Drg. No. Sa 23003A/M Adv. Alt- S And As Per Spec. No. Rdso/Spn/194/2006 (Rev 2.0) Or Latest And Frp Material As Per Rdso Spec. No. Rdso/Spn/151/1997 Or Latest. , Supply Of Shunt Signal Post Complete With Base. Gi Pipe, B Class Of 80Mm Dia. Of Min. 1 Meter Length To Be Supplied By The Contractor. , Supply Of Position Light Led Based Shunt Signal Unit (As Per Rdso Drg. No. Sa-23840). , Supply Of Off-Set Bracket 5-1/2 For Signals & Routes As Per Specification No. Irs: S-10/78 And Drg No. Sa-23080(Adv) Alt-1 Or With Latest Amendment. , Supply Of Retro Reflective Signal No. Plates As Perirsem Drg No. 19-D10 With Clamps, Nut, Bolts And Other Accessories Required For Fixing. , Supply Of Pad Locks 50 Mm With Common Key Make Godrej / Navtal Only. , Supply Of Apparatus Case With Miniature E Type Locks With Keys (1 Key Per 5 Location Boxes) Of Ward No. 41 (As Per Specification No. Irs: S-30/64 & Rdso Drg. No. Sa- 3376/M With Latest Amendments) On Both The Doors, Duly Painted With Red Oxide.-Single Case As Per Drg. No. Sk-783-1/2 & 2/2 With Latest Alteration. , Supply Of Resettable Fuse, Type Polymeric Positive Temperature Coefficient (Pptc) Fuse Of Make Littlefuse/Fuzetec,/Tyco/ Bourn/Raychem. Rating Of Fuse Will Be Provided By Consignee As Per Site Requirement. , Supply Of Cartridge Fuse Block Made Of Pbt As Per Rdso Drg. No. Sa- 23748 Alt. 4 And Spec. No. Irs-S- 75/2006 With Latest Ammendment. Fuse Block Shall Be Suitable For Round Head Type Fuses. (Material Inspected By Rdso , Supply Of Round Head Type Non Detoriating Type Low Voltage Cartridge Fuse As Per Specn No. Irs/S/78/92 With Latest Amendments 2A/4A/6A/10A Capacity. The Bifurcation Of The Fuses Shall Be Given By Site Incharge At The Time Of Execution Of Work. , Supply Of Earth Electrode Assembly As Per Drg. No. S&T/Con/Kota/Earthing/01 Alt- 01. All Nut, Bolts & Lugs To Be Of Stainless Steel. The Earth Electrode Pipe Shall Be B Class/ Medium Grade As Per Specification No. Is: 1239 Pt. 1/ 2004 Of Nominal Inner Dia 50Mm, Outside Dia (Max 60.8 Mm, Min 59.7 Mm), Thickness (3.6Mm), Tolerance In Thickness (+ Not Limited, - 12.5 Percent). , Supply Of Electric Point Machine Irs Make 110V Dc Operation (Ac Immunity 160V) Nontrailable, Complete With Lock, Detector, Cable Termination Box And Slides For Lock And Detector (Rotary Locking) As Per Specification No. Irs: S-24/2002 Amendment-1 Or Latest, Requirement Of Point Machine Is 143 Mm Throw Only As Per Rdso Drg. No Rdso/S-10800. , Supply Of Ground Connection Complete Set Suitable For Irs Type Point Machine For Ordinary Turnout Of 60 Kg Rails As Per Rdso Drg. Rdso-S-3361. , Supply Of G. I. Bend Pipe, B Class/ Medium Grade, 50 Mm Dia & 1.2 M Straight Length And Having Fixing Plate Welded With Bent Pipe As Per Drg. No. Dy.Cste(Con)/Kota/5 For Point Machine Cable Entry. , Supply Of Pre-Wired Crank Handle Cum Key Lock Relay Box (Of Metal) Along With Accessories Viz. Leds, With Approved Type Push Buttons, Terminal Strips, String Rod, Etc. As Per Drg. No. Dy.Cste/C/Kota/6 (A) & (B). , Supply Of William Stretcher Nylon Insulation Set Suitable For Ground Connection For Motor Point Operation. Each Set Comprising Of - (Rdso Drg. No.) T-10367-1 No.,T-10368- 2 Nos., T-10371- 4 Nos. And Conforming To The Specification Irs: S-23 & 40/84 With Latest Amendment. , Supply Of Gauge Tie Plate Nylon Insulation As Per Rdso Drg. No. (T-10372- 1 No., T-10368- 3 Nos., T-10371- 6 Nos. In Each Set) And To The Specification Irs: S-23 & 40 With Latest Amendment As Applicable. , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) End Plug , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) Cable Sealing Plug , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) Plastic Coupler , Supply Of Double Walled Corrugated (Dwc) Pipe Made Up Of High Density Poly Ethylene (Hdpe) Of Size 103/103.5 Mm Inner Dia And 120 Mm Outer Dia In 6 Mtr Straight Length As Per Britsh Standard No. Bsen 50086-1 And Bsen 50086-2-4 And Bis Draft Specification Doc No. Etd 14(5071) And Etd 14(5072) Along With One Coupler Per Every 6 Meters. , Supply Of 20 Pair Pvc Cable 0.5Mm Dia As Per Tech.Specn.G/Wir-06/03March 2002 Or Latest, Make Finolex, Polycab, Birla, Delton Or Havells , Supply Of 2-Zone Amplifier As Per Technical Spec. , Supply Of Vf Tapping Transformer470:600 Ohms To Rdso Spec No.Irs.Tc.22-76 Or Latest. , Supply Of Fiber Distributionmanagement System For 24Fiber Complete (48 Fibrescomplete Alongwith Euroadopters, Pigtail) Of Make Birla, 3M, Tvs, R&M, Orlatest Superior Make As Perinstruction Of Site Incharge. , Supply Of Cat-6 Shielded Cable. Make - Dlink Or Similar Reputed Make. , Supply Of Power Cable Pvc Insulated Flexible 3-Coremulti Strand Power Cable Of 2.5 Sqmm Shall Conformto Specification No.Is:694:1990 Or Latest. (Oemscompliance To Is 694 Is Required Along With Thedelivery For The Material) , Supply Of Vrla Fully Charged Battery 48 V Dc /300 Ah (Stackable) As Per Irs:S-93/96 (A)(Amd-1) Or Latest. , Supply Of 48V 25Amp ( 3+1 ) Fr/Fc Module Battery Chargerrdso/Spn/Tc/23/1999 Ver4.0 Amd1 Or Latest. , Supply Of 4 Port Lan Extender 30 Mbps Fast Ethernet On 4W/2W Configurable & It Should Support Ac And 48V Dc Power Supply As Per Rdso Specification No. Rdso/Spn/Tc/82/2020 Rev. 2.0 Or Latest. Make: Mrotek/Team Engineering/Cygnus Or Similar , Supply Of 32 U Way U-Link Panel With 32 Nos U Link Connector Of Protel Make Or Better. , Supply Of Ofc Patchcord/Jumper Cable Of Reputedmake/Brand, 10 M Long, With(1) Fc/Pc Connectors On Bothsides Or (2) One End Fc/Pcconnector And Other Endcompatible To Work With Stm-4. Insp. By Consignee. , Supply Of Maintenance Free Earth Consisting As Per Rdso Specification No. Rdso/Spn/197 Ver 1.0 Effective From 04.07.2016 Consisting Of Single Earth Pit Which Includes Supply Of 35 Mm²/16 Mm²/10 Mm²multistrand Single Core Pvc Insulated Copper Cable As Per Is 694 For Connecting Main Earth Electrode To Meeb In The Equipment Room Induplicate As Per Manufacturers Recommendations And As Per Rdso Specifications As Follow: (Material Inspected By Rites) (A) Supply Portion (B) Copper Bonded Steel Electrode Of 3.0 Meters Long, 17 Mm Diameter With Copper Bonding Thickness Of Minimum 250 Micronsand Ul Listed And Marked: 1 Nos. (C)Earth Enhancement Compound Of Rdso Approved Brand Supplied In Sealed Bag Of Minimum 10 Kg: 3Nos. (D) Copper Strip Of 150Mm X 25Mm X 6 Mm To Terminate Earth Rod:1 Nos. (E) Copper Strip Of 300Mm X25 Mm X 6 Mm (Meeb): 1 Nos. (F)Copper Strip Of 150Mm X 25 Mm X 6Mm (Meeb): 1 Nos. As Per Rdso Tan: Sts/E/Tan/3006 Dated 26.06.2025 , Supply Of Hylem Sheet Resin Bonded 10 Mm Thick , Grade P3 In Standard Size Of 1.22 X 1.22 Meter As Per Specification Is 2036 Of 1974 .Oem /Authorised Dealers Gaurantee Certificate To Be Submitted At The Time Of The Supply. , Preparation & Submission Of Cable Route Plan Of Main & Tail Cables, Cable Corage Plan And Location Particulars, Ct Rack Particulars,Ct Rack Vinay Flex, Meggering Report, Earth Resistance Particulars, Traction Bonding Diagram, Swrd. And Any Other Drawing / Particular Required In Auto Cad In Pendrive In Size As Per Requirement Of Drawing /Extant Practice Of Wcr. Each Sheet Should Have A Block For Signature Of Railway Officials As Well As Block For Signature Of The Firm, Where Signature Shall Be Put Up By The Authorized Signatory Of The Firm. The Name Of The Work As Given By The Railways Shall Be Written On Every Sheet Under The Work Column. One Complete Set Of Tracings And Four Sets Of Copies Of Complete Above Detailed Particulars / Drawings Along With One Pendrive To Be Supplied By The Contractor In Thick Plastic Folder. Item Will Be Per Station. , Preparation Of Swr Literature In English/Hindi Along With Associated Mid-Section Interlocked Gate With All Corrections As Per Approved Swrd & Approved Sip.For This All Technical Corrections,Editing, Grammatical Correction Etc. Are To Be Carried Out And One Rough Print To Be Given To Railways For Approval Before Printing, As Required For Final Processing Of Crs Sanction. This Alsoincludes Preparation Of Maintenance Cards In Format Provided By Rly. Item Will Be Per Station. , Making Photocopies & Binding Of Theswr Literature In English/Hindi /Diglotform As Per Railway Practice. , Printing And Installation At Site Of Vinyl Flex Of Free Size. This Includes The Supply Of 1 Check Print In A3 Or Suitable Size Of Paper To Railway For Checking And Approval. After The Approval Of Railway Officials, Supply And Installation Of Flex At Site Will Be Done By Contractor. , Supply Of Industrial Grade Inverter, Gallant Or Similar Reputed Make Of Adequate Capacity And In Numbers To Be Provided For Make System Configuration As Required For Site Specific Needs. Input:24 V Dc, Output:1 Ac/600Va, Pure Sine, Having Input Voltage Of 24V, Input Voltage Range 20V Dc --30V D, With Max Current Consumption Of 28A And Output Voltage 120V Ac +/- 2% 100 V Ac / 6A ---130V Ac/ 4,6 A) /230 V Ac +/- 2% (200V Ac/3A ...240V/2,5 A). Manual Selection Of Ac Output Voltage Via Single Terminal, Form Of Output Voltage Pure Sine. Real Power 480W, Mtbf ( Iec 61709)- 532525 H (40 °C), Screw Connection Conductor Size 0.2Mm2 ---4Mm2 , With Signal Output, Ambient Temperature (Operation) -- 25°C--- 60°C, Max Permissible Relative Humidity (Operation) 95% Shock-20G In All Directions (En 60068-2-27), Vibration (Operation) - 5 Hz -- - 100 Hz 0.7G (En 60068-2-6), Noise Immunity In Accordance With En 61000-6-2. Make:- Phoenix Contact Or Similar. , Supply, Installations, Wiring,Testing, And Commissioning Of Universal Earth Leakage Detector 8 Channel (3 Channel Card For Monitoring 110V Acand 5 Channel Card For Monitoring Dc Voltage 24V,24V, 60V, 60V & 110V) As Per Rdso Spn No.Rdso/Spn/256/2025 Ver 2.0 Or Latest. All Materials Required For Installations, Wiring,Testing And Commissioning Willbe Supllied By Contractor. Thematerial Should Be Supplied From Rdso Approved Source Only. , Supply And Installation Of Cabinet Console Unit Of Suitable Dimensions To House Vdu Control Terminal As Per Drg. No. 21-D5 Of Irsem (June-2021)-Appendix-Ii, Along With Cpu, One Set Of Input Device (Keyboard & Mouse Etc), Monitor (55 Inch) 4K Resolution And Power Supply Arrangements. The Detailed Drawings Of The Cabinet Along With Placement Of Various Equipments Inside The Cabinet Shall Be As Per Above Mentioned Drawings .Vdu Control Terminal Shall Be Approved By The Railway Engineer Before Supply. Note: Technical Requirements Are Attached Herewith. , Supply And Installation Of Covered/Secured Housing Cabinet Console Unit Of Suitable Dimensions To House Maintenance Terminal As Per Drg. No. Dy.Cste/Con/Kota/Vdu/01/ Alt. , Along With Cpu, One Set Of Input Device (Keyboard & Mouse Etc), Monitor (55 Inch) 4K Resolution And Power Supply Arrangements. The Detailed Drawings Of The Cabinet Along With Placement Of Various Equipments Inside The Cabinet Shall Be As Per Above Mentioned Drawings. Maintenance Terminal Shall Be Approved By The Railway Engineer Before Supply. Note: Technical Requirements Are Attached Herewith. , Supply ,Provision And Installation Of Permetric/Ring Earth (Maintenance Free Earth) Arrangemnt As Per Rdso/Spn/ 197/2016 Version 1.0 O Rlatest (With Latest Amendement). Number Of Earths Covering Entire Area Should Be Minimum 12. If Some Increase And Decrease In Number Of Earth , Proportionate Payment Will Be Made. Supply Of All Requites Material As Per Latest Rdso Guide Line. Earthing Shall Comply All Guidelines Specified Inrdso Tan No. Sts/E/Tan/3006 Dated 26.06.2025, (Unit -Per Station). , Installation Of Cable Termination Racks Assembly Complete Including Wall Supports, Scaffolding, Fixing Of 8 Way/ Ara/ Disconnect Screw Less, Spring Cage Type Terminal & Other Necessary Accessories Etc. The Work Shall Be Done As Per Approved Plan, Extant Practice On W.C. Railways & The Introduction Of Railway Engineer At Site. (All Fixing Material To Be Supplied By Contractor) As Per Typical Rack Arrangement Wcr Drg. No. S&T Eqpt. Bldg/2013/Pt. 1/4. The String Rod Shall Be Fixed On Phenolic Laminated Sheet. , Termination Of Cable Cores On Ara Terminal/ 8-Way/ Wago Terminals In The Cable Termination Rack. This Includes All Associated Works Of Pulling Out The Cable From Underground, Peeling Off Insulation, Dressing Of Cable Core With Lacing Thread Supported On String Rod With Contractors Own Material. This Includes Soldering & Earthing Of Armour Of Cables On Ct Rack. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site.Item Will Be Per Rack. , Wiring In Relay Room/ Auto Hut/ Ibs Hut/ Lc Gate Hut:- Plugging Of Q-Series Relay, Metal To Metal Relay/ Relay Groups. Energisation Of The System, Making The Panel Through, Functional Test As Per Control Table With Contractors Own Mock Panel, Break Test & Wire Count Test If Applicable To Be Done In Presence Of Railway Engineers. This Will Include Wiring Alterations Required If Any At That Stage, Preparation And Submission Of Wire Count Detail Register Etc. The Work Shall Be Done As Per Extant Practice On W.C. Railway & The Instruction Of Railway Engineer At Site. All Type Of Resistances, Capacitors Etc. Required For Commissioning Have To Be Provided By The Contractor Free Of Cost & Commissioning Of System After Testing. Item Will Be Per Rack. , Lettering & Numbering Of Detail And Description Writing Of Particulars Of Terminations & Equipments On Relay Rack, Relays, Cable Termination Rack, Battery & Power Equipments, Ips, Operating Panel, Axle Counter Etc. Constituting Entire System With Contractors Own Paint And Writing Material (Asian Make Or Similar Enamel Paints Or Similar Paint Only To Be Used). The Work Shall Be Done As Per Extant Practice On W.C. Railway & Instruction Of Railway Engineer At Site. This Also Include Writing Of Ct Rack Particular On Formica Sheet .Item Will Be Per Station. , Supply Of Conventional Lightening Protection System Consisting Of Franklin Rod Of 16Mm Dia, Single Prong Spike Made Of Copper Of Length 600Mm. Appropriate Reducer/Coupler For Connecting Franklin Rod And Gi Mast, Gi Mast Approximately 1.5-Inch Dia, 6 Mtr Length With Flanges For Installation Of Franklin Rod With All Supporting Accessories, Such As Guy Rope, U-Bolt, Thimble, Adjustable Clamp, D-Shakle, Hook Etc. This Also Includes Installation And Commissioning Of Conventional Lightening Protection System Consisting Of Franklin Rod, Appropriate Reducer/Coupler, Flanges And Gi Mast With All Supporting Accessories Such As Guy Rope (6 Mm Gi Wire), U-Bolt, Thimble, Adjustable Clamp, D-Shakle Hook, Etc. , Supply. Installation, Wiring And Commissioning Of Smps Based Integrated Power Supply System With (Vrla Batteries Of 55+5 Nos.) Spares And Tools As Per Rdso Specification No. Rdso/Spn165/2023 With Latest Amendment Applicable As On Date Of Tender Notice And As Per Drawing Provided By Railway At The Time Of Execution Of Work. Including Connection To Change-Over Unit Through Underground Cable Duly Supplied By Railway. For Connecting Ips To Battery Bank, Suitabe Length In Meter Each Of Red And Black Colour Cable Of Size As Per Battery Ah Capacity Is To Be Supplied By Tenderer. 12 Core X 1.5 Sq. Mm Signalling Cable For Connecting Ips To Status Monitoring Panel Will Be Supplied By Railway Free Of Construction Supply And Commissioning Of Ips Should Be As Per Rdso Letter No. Sts/E/Ips/General Dtd. 03.04.2008. This Includes Transportation, Loading And Unloading Of Ips System Complete And Batteries From Depot To The Site Of Installation. Erection Of Power Distribution Board & Its Connection To Ips, Bus Bars And Relay Racks In The Ips Room And Relay Room (As Per Site Engineer Instructions) With Contractors Own Wiring Materials. Lugs, Ladder, Dwc Pipe, 6/10/16/25 Sq Mm Power Cable As Per Load Etc. And As Per Requirement. This Also Include Fabrication And Fixing Of Ac/Dc Power Distribution Board Made Of Phenolic Laminated Sheet Erected On A Relay Rack (To Be Supplied By The Railways), All Connectors As Per Site Requirement To Be Supplied By Railway. Fan Will Be Supplied By The Railway. The Contractor Shall Liason Pursue/ Chase With The Ips Oem For Battery Charging And Commissioning Of Ips As Per Schedule. This Also Includes Supply Of Two Sets Of Power Cable Route And Equipment Plan For Ips And Relay Room. Spares Shall Be Supplied As Per Rdso Specifications. , Supply, Installations, Wiring, Testing, And Commissioning Of Networked Data Logger To Monitor 1536 Digital And 48 Analog Inputs. As Per Rdso Spec. Irs -S- 99/2006 (Amdt-3) With Latest Amendments And With Complete Accessories With Contractors Own Material. This Includes Power Supply For Adequate Capacity, Battery, Fault Diagnostic For Failure Analysis And Modem Card For Monitoring Data Logger , Complete Data Logger And Processor Module Shall Be Placed In Precedent Rack Of Suitable Siize To Be Supplied By The Contractor. Materials Also Will Be Supplied By Ontractor As Per Annexure. This Also Includes Programming Of Data Logger For Fault Diagnostic In Suitable Structured Language In Consultation With Rly. (512 Digital 32 Analog Input). This Also Includes Loading Of Networking Software And Networking Of Data Logger With Divisional Hq. The Requisite Communication Cable/Channel For Networking Will Be Arranged By Railway. , Installation, Testing, Commissioning And Supply Of Automatic Fire Detection & Alarm Complete System As Per Below Details-Supply, Installation, Testing & Commissioning Of Microprocessor Based Intelligent, Addressable, Modular, 1 Loop (Minimum 70 Detector/Devices Per Loop-Expandable To 2 Loops) Fire Alarm Control Panel With Lcd Display With 160 Character With Soft Keys For Displaying Alarm, Events And Operating Functions, Day/ Night Operation Function, Remote Maintenance Service Feature Etc. The Panel Should Be Multiprotocol Ie Able To Support At Least 2 Different Makes Of Addressable Detectors. The Panel Should Have Minimum Two Relay Outputs & 1 Monitored Sounder Output. It Should Have Provision To Be Connected To Repeater Panels In Future.The Panel Shall Capable To Operate On 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts, Sealed Lead Acid Maintenance Free Batteries Sufficient For 24 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During Emergency Condition. Panel Should Be Ul Or Fm Or Vds Or Lpcb Certified And Shall Comply To Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Manual Call Points, Push Type & Resettable With Key, With In-Built Isolator. Shall Be Ul Or Fm Or Vds Or Lpcb Compliant And Shall Comply To The Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Hooter Cum Strobe Complying To The Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Analogue Addressable Multisensor Detector With Multiple Sensitivity( Adjustable At Site) Levels , Programmable For Timed Automatic Sensitivity Selection With Base, And Other Accessories As Required And Detectors Shall Be Ul Or Fm Or Vds Or Lpcb Listed. The Detectors Shall Comply To The Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Resettable, Analogue Type Linear Heat Sensing (Lhs) Cable Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Lhs Interface Module With All Accessories For Single Stretch, Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. , Supply, Instalation, Testing And Commissioning Of Fire Survival Circuit Intrigity Cable Each Lot Having 200 Mtr. Cable With All Accessaries Connecting Of All Fire Alarm Devices As Per Rdso Rdso/Spn/217/2021 Rev.3.0 With Latest Amandment.The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Instalation, Testing And Commissioning Of Analogue Addressable Loop Powered Monitor Module With Inbuilt Isolator Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. (I) Zone Module = 02 Nos. Or (Ii)Realay Module = 02 Nos. Or (Iii) Monitor Module = 02 Nos. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Analogue Addressable Loop Powered Control Module Fitted With Bi-Directional Inbuilt Isolator Providing Two Voltage Free, Single Pole, Change Over Relay Output, Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest.The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Isolator Device To Isolate The Circuit In Case Of Short Circuit, Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. , Supply, Installation, Testing & Commissioning Of Aspiration (Airsampling Type) Detection Unit To Cover 5000 Square Feet Area Withall Accessories, Vds/Ul/Lpcb Approved, Complying Tordso/Spn/217/2016 Ver1. The Material Should Be Supplied From Rdso Approved Source Only. , S U P P L Y , Installation, Testing & Commissioning Of 2C 1.5 Sq Mm Twisted Shielded Armoured Copper Cable (Per Meter) With Accessories. , Supply Of Pvc Conduit Pipe Rigid Plain Ended Conduit Size 1 Inch (25 Mm) Is:9537 (Part-3) And 9537 (Part-1) 1980 With Latest Amendment Isi Mark With Minimum 1.2 Mm Wall Thickness & One Socket At Every 3 Meter Pipe. Make/Brand - Primco Plast Or Superior , Transportation And Fixing Of Pvc Conduit Pipe/Channel/Casing Caping On Wall Or Structure With Drawl Of ( One Or More No. Of) Telecom/ Power/ Data Cable With Proper Finishing. This Also Includes Concealed Wiring As Per Site Requirements And As Per The Directive Of Site Engineer. By Self. , Supply Of Gang Box ( For Multi Sensor Type Smoke Detector) , Execution/Fixing Of Gang Box.195 , Installation, Wiring, Testing & Commissioning Of Fuse Fail Indication Cum Monitoring And Automatic Change Over System. The Item Unit Will BePer Station.Cables Required For Execution And Installation Shall Be Supplied By Contractor At His Own Construction , Supply, Installation, Testing & Commissioning Of Universal Fail Safe Block Interface For Double Line. All Materials Like Wires/Lugs Etc. Will Be Supplied By The Contractor. - Each Set Constisting Of Following(I) Universal Fail - Safe Block Interface For Double Line Complete With All Accessories As Per Rdso Specification No. Rdso/Spn/147/2005(Amndt-1 Or Latest) Spec. No. Irs: S-104/2012 Ver.0 - 2 Nos. (Ii) Relay Rack With Due Locking & Sealing Arrangement Including Relays [Qn1-19 Nos., Qna1-07 Nos., Ql1 - 2 Nos., Timer - 1 No.] And Wiring As Per Wiring Diagram Rdso Drg. No. Rdso/S/32018 (With Latest Amdt.) - 2 Nos.(Iii) Block Panel Complete With Accessories As Per Rdso Drg. No. Rdso/S/ 32017 (With Latest Amdt.) - 2 Nos. (Iv) Block Telephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 - 2 Nos. , Supply And Installation Of D.P. 50 Pairs Krone Type Module Ms: 20 Swg , Supply And Insttaltion Of D.P. 20 Pairse Module Ms: 20 Swg , Supply And Installation Of D.P. 10 Pairs Krone Type With Krone Type Module. Ms : 20 Swg. , Splicing Of Optical Fiber Core And Routing In Joint Closure/Fdms As Per Instruction Of Site Engineer. Item Will Be Per Fiber. , Installalation Of Fdms With All Installation Materials,Restoration Wall Etc. To Original Condition Alongwith Splicing And Termination Of Optical Fibres 2X24 Fiber Cable,Routing/Dressing Fibers As Per Directions Of Site Engineer. , Supply And Fixing Of Rack 42U, 19 Inch Rack, Comrack, President Or Rittal Or Equivalent Make With With Full Front Glass Hinged Door , Cable Manager, 4 No Equipment Tray, 6 Pin Power Distribution Board , 4 Fan Cooling Fan Tray, Earthing Kit, 4 Nos Wheels Lock And Key And Other Accessories. , Supply And Installation Singleport Lo Box With Smb. Make :Anchor-Roma Or Equivalent.. , Supply And Installation Of Opticaljoint Enclosure Conforming Tordso Specno.Rdso/Spn/Tc/68/2014 Wwithrev.2.0 Or Latest Amendment Andsplicing Of Optical Fibre Cable (24F)And Testing Of Fibre For 1310&1550 Nm Shall Be Carried Outevery Joint Locations. , Supply, Installation, Testing And Commissioning Of Primary Digital Multiplexing Equipment (Pdmux) As Per Rdso Specification No Irs:Tc-68/2012 Rev.0 Amdt.1 Or With Latest Amendment Compatible To Webfil Made Pd Mux To Be Supplied By Rdso Approved Vendors And Their Authorized Vendors Only. , Supply, Installation & Commissioning Of 002 100/1000 Mbps Lan/04X2 Mbps Wan (04 Nos.G.703 Interface) As Per Specification No. Rdso/Spn/Tc/84/2008 Or Latest With Accessories. , Supply, Installation Of Maple 4C Or Equivalent 1U, 19 Inch Rackmountable Device Consisting Of Four E1 Ports And Three Slots And One Slot Populated With 2 W/4 W E& M Supporting Upto Eight Interfaces, Balance Two Slots Empty, Unit Shall Supports Both 230 V Ac / 48 V Dc Power Supply Including 50 Pin Cable One No. For Supporting Both 2W/4W E & W, Ac Adaptor One Number. Two Year Warranty. The Work Shall Be Done As Per Location Plans And Instruction Of Rly Engineer(Field Officer) At Site. All The Required Cable And Adaptor & Accessories Etc. Will Be Supplied Free Of Cost By Tenderer With The Satisfaction Of Railway Engineer At Site. Make- Mrotek, Realtime, Cygnus, Cisco Only.Specifications With Latest Software. , Supply And Installation Of Multi Telephone Way Station Equipment With Necessary Mounting Arrangement On Standard 19 Rack. It Shall Be (-) 48 Volt Operated As Per Rdso Specification No.Rdso/Spn/Tc/66/2007 With Latest Amendment. The Equipment Supplied In This Work Should Be , Excavation Of Trench 1.2 Mtr Deep, 300Mm Wide At The Bottom Along Main Line In Normal Soil, Including Clearing Of Bushes, Trees Etc And Refilling Of The Trench By Excavated Soil And Ramming After Laying Of The Required Quantity Of Cables As Per Instructions Of Engineer At Site. The Work Also Includes Excavation Of Trenches In The Beds Of Culverts. Whenever The Dimensions Of Cable Trenches As Mentioned In The Tender Schedule Are Not Easily Achievable Due To Terrain Conditions, Then Payments Will Be Made On A Pro-Rata Basis, For The Dimensions Achieved.The Specific Approval Of The Engineer In Charge Of The Work (Not Below The Rank Of Sr. Scale Officer), Will Be Required For Such Dispensation. , Excavation Of Trench As Per Cable Route Plan, 1.2 Mtr Deep, 500 Mm Wide At The Bottom Along Railway Track In Normal Soil. This Work Includes Covering Of Cables Laid In Trenches By Loose Excavated Soil For A Layer Of 50 Mm Thickness Approximately Before Covering By Shahabad Stone/ Bricks / Fly Ash Bricks/ Half Reinforced Cement Concrete Pipe, Clearing Of Route, Bushes Etc. And Refilling Of The Trench By Excavated Soil. Generally There Shall Be No Proportionate Payment For Cable At Depth Lesser Than That Specified In The Tender Schedule. If It Is Not Possible To Reach The Required Depth At Any Location, Then The Contractor Shall Obtain Prior Approval Of Site Engineer, Who Shall First Get The Dispensation, From Dy.Cste Vide Letter No. 2013/Sig/Sem Pt.- 1I/Misc, Dated 12.06.2014 Of Railway Board And Only , Excavation Of Trench As Per Cableroute Plan, 1 Mtr Deep, 300Mm Wide At The Bottom Along Main Linein Hard Soil / Murrum, This Workincludes Covering Of Cable Laid Intrenches By Loose Soil For A Layer Of50 Mm Thickness Approximatelybefore Covering By Bricks. , Excavation Of Cable Trench 1.0M Deep From The Rail Flange And 300Mm Wide Across The Track, For Track Crossing And Refilling After Laying Of Rcc/ Gi/ Dwc Pipes And Restoring The Track To Its Original Condition. Generally There Shall Be No Proportionate Payment For Cable At Depth Lesser Than That Specified In The Tender Schedule. If It Is Not Possible To Reach The Required Depth At Any Location, Then The Contractor Shall Obtain Approval Of Railway Site Engineer, Who Shall Get The Dispensation, From Jag Vide Rly. Boards Letter No. 2013/Sig/Sem Pt.-Ii/Misc., Dated 12.06.2014 Before Commencement Of Cable Laying Process And Only Then Shall The Proportionate Payment Be Made To The Contractor. The Work Shall Be Done As Per Extant Practice On W.C. Railway & Instruction Of Railway Engineer At Site. Cable Trench As Per Drg. No. Ts/Cable Laying/12/03/03 Alt.-1. For Achieving 1.0 Mtr Depth For The Bottom Most Cable, The Contractor Shall Dig The Trenches To A Depth, Slightly More Than 1.0M To Take Care Of Practical Problems. Laying Of Rcc/Gi/Dwc Pipe And Cables Is Covered In Separate Item. , Blowing / Drawing Of Ofc/6 Quad Through Hdpe Duct & Protective Work Already Provided In The Excavated Trench. All The Equipment And Machinery Required Shall Be Arranged By The Contractor At His Own Construction Cable Should Be Laid According To The Technical Conditions And Instructions Of The Site In Charge. Note: Ofc Will Be Supplied By Railway. , Transportation & Laying Of Hdpe Duct In The Trenches And In The Protective Works (I.E. Gi Pipes/Dwc Pipe/ Boring Etc.) And Supply As Well As Pulling Of Nylon Rope Through It At Different Places As Per Direction Of Engineer-In-Charge. This Also Includes Laying Of Duct In Track Crossings & Road Crossings Etc. Note-Hdpe Pipes Along With All Accessories Such As Couplers, Plugs, End-Plugs Etc., Which Are Required For Proper Laying & Fixing Of Hdpe Duct, Shall Be Supplied By Railways. , Supply & Laying Of Well Burnt Bricks Of Size 200Mm X 90Mm X 65Mm Inside The Trench (With The Brick Length Being Perpendicular To Cable Route) After Laying Of Cable & Covering Of Cables Laid In Trenches By Loose Excavated Soil For A Layer Of 50Mm Thickness Approximately, In Station Area From Outermost To Outermost Signal Or At Any Other Location As Per Instruction Of Site Engineer. Note:- Size Of Bricks To Be Got Approved By Railway Site Engineer. In Case Brick Size Is In Variance With The Size Given In The Tender Schedule Then Proportionate Payment On Volumetric Basis Shall Be Paid To Contractor Subject To A Maximum Limit Of Schedule Rate. , Laying Of All Types Of Signal/ Telecom/ Power Cable Of Various Cores/ Sizes In Excavated Trenches. The Work Shall Be Done As Per Extant Practice Followed On W.C. Railway And As Per The Instructions Of Railway Engineer At Site. , Installation Of Thermo-Shrinkable Jointing Kits For Making (A) Straight Through Joints Without Transformer For 6 -Quad Jelly Filled Cable, (B)Derivation Joint Without Transformer For 6-Quad Jelly Filled Cable, And (C)Straight Through Joint Without Transformer For10 Pr/20Pr. Pijfcables And Construction Of Brickchamber For Protection Of Joints Withcontractors All Materials As Per Drg.No. Given By Railway Where Vf Transformers Are Notrequired. All The Materials Required For The Work Are To Be Arranged Bythe Contractor Himself At His Own Cost Except Thermo-Shrinkable Jointing Kitwhich Is Already Covered In Supplyportion Of The Tender. After Jointingthe Cable Through Test Such Asinsulation Test, Continuity Cablelosses Etc. To Be Carried Out Jointlywith The Railway Engineer. If Anydefect Or Any Damage Observedduring Jointing, The Contractor Shouldredo The Joint Free Of Construction , Cutting Of All Types Of Roads (1 Mtr X300 Mm)/ Platforms (300Mm X 300Mm) Preparatory To Trenching, Excavation And Refilling After Laying Of Rcc/ Gi/ Dwc Pipe & Restoring Them To Original Condition. Generally There Shall Be No Proportionate Payment For Cable At Depth Lesser Than That Specified In The Tender Schedule. If It Is Not Possible To Reach The Required Depth At Any Location, Then The Contractor Shall Obtain Prior Approval Of Railway Site Engineer, Who Shall Get The Dispensation, From Jag Vide Rly. Boards Letter No. 2013/Sig/Sem Pt.-Ii/Misc., Dated 12.06.2014 Before Commencement Of Cable Laying Process And Only Then Shall The Proportionate Payment Be Made To The Contractor. This Also Includes Laying Of Any No. Of Dwc/Rcc/Gi Pipes, As Per Requirement. The Work Shall Be Done As Per Extant Practice On W.C. Rly & Instructions Of Railway Engineer At Site. The Dwc/Rcc/Gi Pipes Will Be Supplied By Railway. Laying Of Rcc/Gi/Dwc Pipe Is Covered In Separate Item. , Supply, Fixing, Painting And Installation Of Rcc/Stone Cable Route Markers As Per Drawing No. Drm/Kota/Misc-87 Or Wcr/Sig/St.Rt.Marker/201401. Placing And Securing Of Cable Route Markers In Trenches At The Specified Interval And Diversions, Joints Etc Along The Cable Route. The Work Shall Be Done As Per Extant Practice On W. C. Rly & The Instructions Of Rly Engineer At Site. Sample To Be Approved By Engineer In-Charge Of The Railways Before Supply, After The Testing Prescribed In Drawing. This Includes Supply Of Paints Of Different Colours As Per Drawing. The Paint Shall Be Either From Asi An Or Shalimar / Apcolite / Berger Having Isi Mark. , Fixing Of Ara/Cage Type Disconnect Terminals And Fuse Blocks With Provision Of Holes On Phenolic Laminated Sheets And Fixing With Galvanised Nuts & Bolts In Location Boxes And Elsewhere. This Includes Provision Of Additional Holes On The Phenolic Laminated Board On Either Side For Cable Conductor Entry. The Work Shall Be Done As Per The Instructions Of Railway Engineer At Site. , Termination Of Cable Cores On Ara Terminals/Cage Type Disconnect Terminals, Fuse Blocks, 8-Way Terminals Blocks, Telecom Terminals In New/Existing Apparatus Cases, Existing Mctb/Existing Telecom Cable Termination Racks. This Includes All Associated Works Of Pulling Out The Cable From Underground, Dressing Of Cable, Making Wiring Tree With Contractor Lacing & Threading Material Etc. Both Ends Of A Cable Core Shall Be Counted As Per Conductor. This Includes Soldering Of Armour Tree/Ring Of Cables And Connecting To Copper Plate Through Gi Wire Bus Bar In Location Boxes. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site. , Excavation, Casting (1:3:6) And Plastering (1:4, With Fine Sand) Of Main Signal Foundation As Per Drg. No. Dy.Cste/C/Kota/1 Alt A With Contractors Own Material Including Ballast, Cement, Local Available Sand, Pvc Pipe & Galvanised Anchor Bolts With Nuts & Washers, Etc. The Hole For Cable Entry Should Be Kept As Per Site Requirement And Instruction Of Railway Engineer At Site. The Required Ferma Of The Size Mentioned In The Drawing For Casting Of Foundation Will Have To Be Brought By The Contractor At His Own Construction All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Erection Of Main Signal (Cls) Post With Surface Base And Signal Unit Complete On Top Or On Off-Set Bracket, Fixing Of Front And Back Staging, Ladder, Guard, Signal Name Plates/Board, Protective Screen, Blanking Of Ladder (0.6Mm Ms Sheet), If Any With Contractors Own Brackets, Nuts & Bolts & Other Fixing Materials. This Also Includes Erection Of Auxiliary Signals Like Calling-On, Shunt Signal. Wooden White Cross-Arms (1000Mm X 100 Mm) To Be Provided By The Contractor Till The Signals Are Commissioned With Contractors Own Material. If The Ladder/Front/Back Staging Is Infringing The Sod, Then Suitable Arrangement Of Fixing Steps For Climbing Up To Signal Unit And Reducing The Size Of Front/Back Staging As Per Instructions Of Site Engineer Shall Be Done. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Termination Of Tail Cable On Main & Auxiliary Signal Units And Wiring With Contractor Own Material, Fixing Of Led Signal Units Etc. Flexible Single Core Copper Wire 2.5 Sq.Mm (50/0.25) Conforming To Is-694:1990 (As Per Aspect Colour) And Lugs Etc. Will Be Supplied By The Contractor. This Includes Insertion Of Tail Cables From Ground To Signal Unit, Thereafter Sealing The Opening And Testing The Signal As Per Instructions Of Railway Engineer At Site. , Excavation, Casting (1:3:6) And Plastering (1:4, Fine Sand) Of Shunt Signal Foundation As Per Drg. No. Dy.Cste/C/Kota/1 Alt A With Contractors Own Material Including Ballast, Cement, Local Available Sand, Pvc Pipe & Galvanised Anchor Bolts With Nuts & Washers, Etc. The Hole For Cable Entry Should Be Kept As Per Site Requirement And Instruction Of Rly Engineer At Site. The Required Ferma Of The Size Mentioned In The Drawing, For Casting Of Foundation Will Have To Be Brought By The Contractor At His Own Construction All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Erection Of Shunt Signal Post With Surface Base, Unit, Number Plate Complete. Wooden White Cross-Arms (1000Mm X 100 Mm) To Be Provided By The Contractor Till The Signals Are Commissioned With Contractors Own Material. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Termination Of Tail Cable On Shunt Signal Units And Wiring With Contractors Own Material, Fixing Of Led Signal Unit Etc. Flexible Single Core Copper Wire 2.5 Sq.Mm (50/0.25) Conforming To Is: 694:1990 Copper Wire As Per Railway Standard And Lugs Etc. Will Be Supplied By The Contractor. This Includes Insertion Of Tail Cables From Ground To Signal Unit, Thereafter Sealing The Opening And Testing The Signal As Per Instructions Of Rly Engineer At Site. , Excavation And Casting Of Apparatus Case Foundation With Mixture Of Cement:Sand:Stone Aggregate/Chip In 1:3:6 Ratio And Plastering With Mixture Of Cement:Sand In 1:4 Ratio, With Contractors Own Metal Sheet Ferma Of The Size Mentioned In The Drawing, Cement, Anchor Bolts, With Nuts & Washers And Other Materials. The Items Also Include Additional Earth Work If Required As Per Instruction Of Rly. Engineer At Site. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. -Single Case Drg. No. Sk 783-1/2 With Latest Alterations , Erection Of Apparatus Cases. This Includes Filling Of Location Foundations With The Seived Sand Being Used For Making The Foundation Of Location Boxes And Plastering On Top Of The Sand. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. -Single Case , Supply, Fabrication And Fixing Of Phenolic Laminated Sheet Board In Location Box By Providing All Fixtures, Double Ended Insulators (06 Nos.), Pvc Coated String Rods At The Back Side For Cable Support With Contractors Own Material. The Work Shall Be Done As Per Drg. No. Sk 783-1/2 With Latest Alterations & As Per Instructions Of Railway Engineer At Site. The Phenolic Laminated Sheets Should Be Of 10Mm Thick, Grade P3 As Per Specification No. Is: 2036 Of 1995 Or Latest. The Size Of The Phenolic Laminated Sheet For Full Case Terminal Board Should Be 800Mm X 950Mm And For Half Case It Should Be 800Mm X 450Mm. In Case Board Size Is In Variation With The Size Mentioned As Per Location Details, Then Proportionate Payment On Area Basis Shall Be Made. This Also Include, The Work To Be Done In Existing Location Boxes (If Required) As Per Instructions Of Railway Site Engineer. - Single Case , Supply, Fabrication And Fixing Of Phenolic Laminated Sheet For Shelf Of Equipments/Batteries With Contractors Own Fixing Material, Angle Frames, Additional In-Between Supporting Angle For The Shelf, Etc. The Work Shall Be Done As Per Drg. No. Sk 783-1/2 With Latest Alterations & As Per Instructions Of Railway Engineer At Site. The Phenolic Laminated Sheets Should Be 10Mm Thick, Grade P3 As Per Specification No. Is: 2036 Of 1995 Or Latest. The Size Of Shelf For Single Case Apparatus/Location Box Shall Be 500Mm X 950Mm And For Half Case Location Box It Shall Be 500Mm X 450Mm. In Case Board Size Is In Variation With The Size Mentioned As Per Location Details, Then Proportionate Payment On Area Basis Shall Be Made. Galvanised Nut & Bolts To Be Used For Fixing Of Phenolic Laminated Sheets.-Single Case , Installation Of Equipments (Relays, Resistance, Chargers, Choke, Batteries, Lv Box, Klcr, Pptc Fuses & Track Feed Charger Alarm Unit, Etc. As Applicable) With Contractors Own Wiring Material, Ms Frame, Copper Lugs Etc. & Wiring Of The Same In Apparatus Cases As Per Location Diagrams, Paralleling Of Spare Contacts Of Metal To Carbon Relays And Wiring Of Potential Free Contact Of Track Feed Charger And Testing Of Track Circuits As Per Instruction Of Railways Site Incharge And Standard Practice. This Also Includes Supply Of Multi-Strand Flexible Single Core Copper Wire 2.5 Sq.Mm (50/0.25) Except For Relay Wiring Which Will Be Done With 16/0.2 Mm Flexible Multi-Strand Wire Conforming To Is: 694:1990 With Suitable Lugs. All Wires To Be Duly Manufactured By Rdso Approved Firms (16/0.2 Mm Flexible Multi-Strand Wire Inspected By Rdso). Note: Pptc Fuses Shall Be Provided As Per Fixing Arrangement Of Pptc As Advised By Hqs Policy Guideline Issued Vide Letter No. Wcr/N-Hq/110/Signal Policy/Sig-32 Pt-Vii, Dtd. 07.11.2013 I.E. Pptc Fuse Are To Be Connected With Crimped Ring Type Lugs And Crimped Area Is Also To Be Filled With Solder. Pptc Lead To Be Provided With Ferrules For Volt & Current Rating Of Pptc. Ferruling For Cable Terminations In Location Box Shall Be Done By Contractor With His Own Cost.-Single Case , Installation Of Earth Electrode Assembly As Per Drg. No. S&T/Con/Kota/Earthing/01 Alt-1 And Connecting Through Stainless Steel Wire 8 Swg Supported On Ms Flat Of Size 5Mm X 40Mm To Earth Electrode As Per Drg. No. T/2014/1 For Signals And T 2014/5 For Location Boxes/Apparatus Cases. The Earth Value Should Be Less Than 10 Ohms Including The Lead Wire. The Value Should Be Measured In Presence Of Railway Supervisors. It Should Be Documented And Painted On Earth Enclosure Made Of Concrete. Only Earth Electrode Will Be Supplied By Railway. All Other Material Required For Provision Of Earthing Will Be Brought By The Contractor. This Earth Can Be Provided For Dps, Block Instruments & Eld Etc. Also, So As To Achieve The Desired Earth Resistance Value. Earth Enclosure To Be Manufactured & Supplied By Contractors Own Material Of Ratio 1:3:6, Without Cover. Additional Connection Of Earth Pipe Including Parallel Connection With Other Earth Pipes With The Function Shall Be Done Using Left Over Pieces Of Signalling Cable. Laying Of Cable Pieces Shall Be Covered In Laying Of Cable Item And Cable Shall Be Supplied By Railways. , Supply & Installation And Testing Of Maintenance Free Earth Consisting As Per Rdso Specification No.Rdso/Spn/197 Ver.1 Effective From 04.07.2016 Consisting Of Single Earth Pit Which Includes Supply Of 35Sq. Mm / 16 Sq.Mm / 10Sq.Mm Multistrand Single Core Pvc Insulated Copper Cable Asper Is 694 For Connecting Main Earth Electrode To Meeb In The Equipment Room In Duplicate As Per Manufacturers Recommendation And As Per Rdso Specification As Follows: As Per Drg Nosdo/Rdso/E&B/001 Dated19.09.08Set223471.48 A)Copper Bonded Staeel Electrode Of 3.0Meter Long,17Mm Dia With Copper Bonding Thickness Of Minimum 250 Microns And Ul Listed Andmarked - 1No. B) Earth Enhancement Compound Of Rdso Approved Brand Supplied In Sealed Bag Of Minimum 10Kg. - 3Nos. C) Copper Strip Of 150 X 25 X 6Mm To Terminate Earth Rod - 1No. D) Copper Strip Of 300 X25 X 6 Mm (Meeb) - 1No. E)Copper Strip Of 150 X 25 X 6Mm (Seeb) - 1No. F)Digging/Auguring/Borring Ofsingle Earth Pit Of 100Mm To125mm Dia To The Depth Of Approximate 2.8M G) Insertion Of 3 Mtr Electrode And Penetrating It At Least 0.2 Mtr. By Pushing Gently With Sledge Hammer Where The Neutral Soilis Assumed. H) Filling Of Earth Pit With Earth Enhancement Compound (Eec) In Slurry Form And Back Filling. I)Carrying Out Exothermic Weld Connection Of Single Earth Electrode To A Copper Tape Of150 X 25 X 6 Mm J) Carying Out Exothermal Weld Connection On The Copper Tapeof 150 X 25 X 6 Mm On Earthe Electrode For Connecting Two35 Sq.Mm Cable For Redundancy K) The Exo Thermal Welding Material For Bonding The Earth System Shall Be Procured From Rdso Approved Firms Which Include Graphite Moulds, Clamps, Weld Metal Powder. L) 300 X 300 X 300Mm (Inside Dimensions)Concrete Earth Pit With Aconcrete Lid Approximately50mm Thick With Pulling Hook Sshall Be Provided To Cover Thepit. Back Side Of The Cover Willbe Painted In Black And Date Of Testing And Average Resistance Value Shall Be Written.The Item Should Be Executed As Per Latest Rdso Tan: Sts/E/Tan/3006 Dated 26.06.2025 , Installation Of Maintenance Freee Earth In Rocky Area As Per Item Supplied Againstwith Contractors Own Materialsrequired For The Same. This Includes :I. Digging/Auguring/Boring Of Single Earth Pit Of 100Mm To 150Mm Dia Tothe Depth Of Approximate 3 M In Rocky Area. Ii.Nsertion Of 3 Mtr Electrode Andpenetrating It At Least 0.2 Mtr. Bypushing Gently With Sledge Hammerwhere The Neutral Soil Is Assumed.Iii.Filling Of Earth Pit With Earthenhancement Compound (Eec) Inslurry Form And Back Filling. Iv.Fillingof Earth Pit With Earth Enhancementcompound (Eec) In Slurry Form Andback Filling. V.Carrying Outexothermic Weld Connection Of Singleearth Electrode To A Copper Tape Of150 X 25 X 6 Mm Vi.Filling Of Earthpit With Earth Enhancementcompound (Eec) In Slurry Form Andback Filling. Vii.Carrying Outexothermal Weld Connection On Thecopper Tape Of 150 X 25 X 6 Mm Onearth Electrode For Connecting Two 35Sq.Mm Cable For Redundancy Viii.Theexothermal Welding Material Forbonding The Earth System Shall Beprocured From Rdso Approved Firmswhich Include Graphite Moulds,Clamps, Weld Metal Powder. Ix.300Mm X 300 Mm X 300Mm(Insidedimension) Concrete Earth Pit With Aconcrete Lid Approximately 50 Mmthick With Pulling Hooks Shall Beprovided To Cover The Pit. Back Sideof The Cover Will Be Painted In Blackand Date Of Testing And Average Earthresistance Value Shall Be Written. , Fixing/ Refixing Of Electrical Point Machine On Existing Layout, Ground Connection During Phase Working (Ni/ Pre-Ni) After Removing The Electrical Point Detector, Fpl Assembly And Mechanical Or Any Other Fittings Including Existing Point Machine Fitting If Any, Adjustment If Necessary, Wiring Of Point Machine Testing And Commissioning Of Electrically Operated Point, Fixing And Connecting Point Indicator On Derail Switch If Necessary. This Will Include Fabrication And Fixing Of Gi Bend Pipes As Per Drg. No. Dy.Cste(Con)/Kota/5 Of S-Shape Of 1.2 Meter Length & 50Mm Dia With Welded Frame For Cable Entry To The Point Machine And Termination Of Tail Cable In Point Machine And Wiring Servicing Of Point Machine & Supply And Filling Of Sae-30 Lubrication Oil . This Also Includes Installation Of William Stretcher Nylon Insulation Set (Complete), Tongue Attachment Nylon Insulation Set And Guage Tie Plate Nylon Insulation Set As Per Rdso Specification. The Work Shall Be Done As Per Extant Practice On W.C. Railway And The Instructions Of Railway Engineer At Site. Internal Wiring Of Point Machine & Cable Termination Suitable For Ei/Pi/Rri Installation, 2.5 Sq.Mm (50/0.25) Conforming To Is: 694:1990 Flexible Copper Wire Of Different Colours & Lug Will Be Supplied By Contractor. Point Machine, Ground Connection, Insulation Sets Will Be Supplied By Railways. This Includes Drilling Of Holes In Tounge Rail, Provision Of High Di-Electric Varnish On Contact Assembly And Wiring During Ni Period. This Also Include Rewiring Of Point Machine If Required As Per Type Of Point Machine & Circuit (Independent Detection) & As Per Instruction Of Site Engineer. To Reduce The No. Of Days Of Ni, The Existing Point Machines May Be Replaced With New Point Machines And Operated From Existing Panel. During Pre-Ni / Ni, Rewiring At Mctb/Location Box/Point Machine Shall Be Carried Out As Per The Requirement Without Any Additional Construction Item Will Be Per Point. , Supply & Fixing Of Klcr Boxes & Fixing Of Klcr Relays. It Includes Supply Of Any Minor Bracket, Nuts, Bolts,Teakwood/Metal, Sun Mica,Paint, Lock, Drilling Hole Etc As Directed By Engineer At Site. It Also Includes Supply And Wiring Of Push Buttons Along With Leds For Klcr Circuit. Rly Will Supply Only Klcr Relays And Contractor Has To Wire Klcr Relays. It Includes Supply Of All The Related Wiring Material. , All Work Pertaining To Horizontal Dirctional Drilling (Hdd)/Boring And Trenchless Cabling. It Includes Supply, Transportation And Insertion Of Self Lubricated Hdpe Pipe And Laying Of Cables In Boring Under The Track/Road/Platform/Circulating Area By Using Different Sizes Of Pipes Depending On Total Number Of Cables Will Be Crossed. The Depth Of Horizontal Boring Should Be Minimum 1 Mtr Upto 3 Mtr, From Rail Flange/ Road Level/Ground Level As Per Site Requirement And As Per Instructions Of Railway Engineer Incharge. This Item Will Be Used For Track Crossing Of Running Lines, Road Crossing & Circulating Area. By Using Self Lubricated Hdpe Pipe Of 120Mm Outer Dia And 103.5Mm Inner Dia In The Bore And Laying Of Cables In The Bore Under The Track/Road/Circulating Area. , Preparation Of Cable Duct 150Mm X 300Mm Deep For Laying Of Cables In Rocky Area And Refilling The Duct (After Cable Laying) With Concrete Mixture Of Proportion 1:3:6 And Grouting The Ends At Either Side Of The Rocky Portion Using Concrete Mixture With Contractors Own Cement And Other Materials. Cable Trench Shall Be As Per Drg. No. Dy.Cste/C/Kota/07/A. Laying Of Cables Is Covered In Separate Item. , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Apparatus Case Full Size , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Point Machine With Ground Connection Complete. (Point Machine With Black Enamel Only Outside And Ground Connection With Red Oxide) , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Main Signal Post With Main & Auxilliary Signal Unit, Surface Base And Complete Fittings As Per W.C. Railways Standard Practice. , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Shunt Signal Post With Signal Unit, Surface Base As Per W.C. Railways Standard Practice. , Lettering, Numbering Of Point Machine, Track Lead Junction Boxes, Block Joint, Glued Joints, , Batteries, Apparatus Cases Etc. (Outside) (Each Item To Be Taken As One Unit ) , Lettering & Numbering Of Termination Particulars, Equipments Names Etc. Legibly And Neatly Inside Location Boxes As Per Standard Practice Of W.C. Railway & Instructions Of Railway Engineer At Site.-Single Case , Cement Concrete 1:3:6 In Foundations With Upto 25Mm Graded Stone Aggregate As Per Instructions Of Railway Engineer At Site. , Provision Of Temporary Gumti Of 3Mtr X 3Mtr X 2.5Mtr On Hire For Ni Working Made Of Water Proof Tent (Coverd On Three Sides Of Wall) With Provision Of Good Quality Turpolene Mat Laid Inside Full Floor Area Of Tent, Two Tables, Two Chairs, Water Dispenser With 5 Mineral Water Bottle Refills Of 20 Ltr Each And Two Incandescent Lamps/ Emergenvy Light As Per Instructions Of Railway Engineer At Site. (Electrical Connection Will Be Provided By Railway). (01 Numbers= 01 Gumti Per Day) , Releasing Of All Equipments Of Relay Room/ Axle Counter Room/ Ips Room/ Battery Room / Asms Room/ Esms Duty Room / Data Logger Room, Cabin Basement And Lever Frames, Covering The Entire Indoor Signaling Gears As Per The Instruction Of Railway Engineer At Site & Their Transportation To Sse/Sig/Kota Depot With Ms/ Ci/ Wooden Materials Duly Seggregated. The Above List Is Only Indicative, The Contractor Has To Release All Old Equipments As Per Pre Commissioning Survey And Instruction Of Railway Site Engineer. , Installation, Transportation, Wiring , Testing And Commissioning Of High Frequency Digital Axle Counter Multi Section Type Complete System Including Central Evaluator(S), Final Track Clearance Relay For Each Track Section, Reset Boxes, Lv Boxes, Detection Points, Mushroom Housing For Track Side Electronics, Earthing Arrangement (If Any As Per Oem Requirement) And All Other Accessories Fully Wired To The Ultimate Capacity And Fully Equipped To The Configuration Specified As Per Rdsos Specification No. Rdso / Spn / 176 / 2013 (Ver. 3) Or Latest And Oem Specification. This Also Includes Installation Of Track Device (Double Rail Contact) Including Digging Of Trench, Fixing Of Deflector Plates, Track Crossing, Laying Of Ant Rodent, Anti-Oxidant & Non -Flame Propagating Type Double Walled Corrugated (Dwc) Pipe Made Up Of High Density Polyethylene Of Required Dia, As Per Is-14930 Part-I Or Ii Or Latest And All Other Accessories As Per Site Requirement For Laying Of Transmitter And Receiver Cable, Installation Of Ejb/Track Side Electronics Including Foundation & Installation Of Earthing (If Any) As Per Oems Guidelines, Technical Requirement & Specification. , Supply Of High Power Main Signal With Led Aspect Integrated Type, Current Regulator As Per Rdso Specn. No Rdso/Spn/199/2025 (Rev. 1.2) Or Latest. - Red , Supply Of High Power Main Signal With Led Aspect Integrated Type, Current Regulator As Per Rdso Specn. No Rdso/Spn/199/2025 (Rev. 1.2) Or Latest. - Yellow , Supply Of High Power Main Signal With Led Aspect Integrated Type, Current Regulator As Per Rdso Specn. No Rdso/Spn/199/2025 (Rev. 1.2) Or Latest. - Green , Supply Of Calling On Unit Led Integrated Type As Per Rdso Specn. No Rdso/Spn/153/2023 (Rev. 5). Or Latest. , Supply Of Led For Shunt Signal Integrated Type As Per Rdso Specn. No Rdso/Spn/153/2023 (Rev. 5). Or Latest.

AI Tender Summary

OUR REF NO 58254615
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 12-11-2026
Authority
Authority Name Central Electronics Limited
Work Description Tender for Provision Of Electronic Interlocking System With Digital Axle Counter (Msdac) In Station Yard, Along With S&T Service Building At Hdn Route Station Hindaun (Han) On Kota Division , Supply Of Powder Coated 1 Way Main Cable Termination Rack Complete With Scaffolding, Fixtures & Accessories Including Square Bars For Mounting 8-Way Terminal Blocks/Wagos, Ladder, String Rods, Frame, Base Assembly, Insulators, J-Bolt, Nut/Bolts & Fasteners, Phenolic Laminated Sheet Board Etc. Siemens Type & As Per Extant Practice On W.C. Rly. Typical Part List As Per Annexure K For 3-Way And Annexure L For 2-Way Attached And Rack Arrangement As Per Wcr Drg. No. S&T Eqpt. Bldg/2013/Pt. 1/4 And Rack Plan As Approved By Engineer Incharge. , Supply Of Powder Coated Relay Rack Assembly Complete With Scaffolding, Fixtures And Accessories Including Ms Bars For Fixing Of Relay Plug Board, String Rods, Fuse Strips With Bracket, 11-Way Bus Bars With Cover And Mounting Brackets ,Runway For Cable/Wires, Frame Base Assembly With Idf Pillar Etc. Siemens Type & As Per Extant Practice On W.C. Rly. Typical Part List As Per Annexure J Attached And Rack Arrangement As Per Wcrdrg. No. S&T Eqpt.Bldg/2013/Pt. 1/4 And Rackplan As Approved By Engineer Incharge. , (I) Supply Of 4 Conductor Disconnect Terminal Block With Test & Measurement Facility, With Screw Less, Spring Cage Clamp Connections Suitable For 0.08 To 2.5 Sq.Mm Conductor With Current Capacity Of 16 Amps As Per Rdso Spcn. No. Rdso/Spn/189/2004 Ver. 3.0 Or Latest. , (Ii) Supply Of End Plate Compatible To Above Screwless Terminals. The End Plates Shall Be Of Different Colour Than That Of Disconnect Terminal Blocks. , (Iii) Supply Of Din Rail Of Dimension 35Mm X 7.5Mm, 1 Mm Thickness, 1Mtr Length, Slotted Compatible To Above Terminals. , Iv) Supply Of End Stop 10Mm For Above Din 35 Rail. , Supply Of Dual Fuse Alarm System / Fuse Fail Indication Cum Monitoring And Automaticchange Over System For Vitalfuses As Per Draft Specificationno. Rdso/Spn/209/2012 Ver2.0 Or Latest. This Consists Fuses Of Different Ratings As 0.6A, To 16A. Number Of Fuses Of Ratings To Be Decided As Per Site Requirent And Engineer In-Charge. (01 Numbers= 01 Fuse).Spares To Be Provided As Per Rdso Spcifications. , Supply Of Insulation Mat For Electrical Purpose 2.2 Mm Thick Size 2M X 1M X Suitable For 3.3 Kv To 11Kv (Class B) Conforming To Is- 15652-2006 , Supply Of Protocol Converter For Interface The Data Logger And The electrical installation System Suitable For Above Data Logger. Any Other Equipment/Connector/Cable Required To Connect electrical installation To Datalogger Wil Have To Be Supplied By Contractor At His Own Construction , Supply Of Automatic Media Change Over Of Modem Working On Redundant Channels For Data Transmission On Ofc/Quad/Microwave Radio. Qty.01 Pair & Modems For Ufsbi (For Use With Secondary Media Ofc/Quad) Qty. 01 Pair. Make Des(Delron Elecronic System Only). , Supply Of Modem Compatible With Existing Ufsbi System Of Des Make Or Similar As Per Specn No. Irs:S-105/2012 (Ver.0) Or Latest Suitable To Interface With Ofc Fiber (Optical Modem) For Deltron Make Ufsbi Provided In Kota Division. , Supply Of Ufsbi Event Logger With E1 / Dark Fiber Connectivity From Site To Control Room. , Preparation In Autocad, Fabrication On Board, Supply & Screen Printing Of Swrd, Track Bonding Plan, Rsp Board On White Formica Of 1200X600x3mm As Per Instruction Of Site Engineer. Proportionate Payment Will Be Made If Size Of Board Get Increased Or Decreased.Rate = Per Board Item , Supply Of Self Supporting Foldable Ladder Heavy Duty Made Of Aluminium C Section Size 66 Mm X 31 Mm X 3 Mm And Climbing Steps Made Of Aluminium 112 Mm Wide (4.5 Inch) On Front Side & Back Side (1 Inch) , Having Service Platform At The Top Size 16 Inch X12 Inch & Rubber Shoes Are Fitted At Four Legs. Size 6 Feet Height Make: Neelkamal, Godgej Or Reputed Make. , Supply Of 48 Fiber Ofc Jointclosure Similar To Specification No.Rdso/Spn/Tc/68/2014 Rev 1.0 Orlatest. , Supply Of Thermo Shrink Jointing Kit For Jointing Underground 0.9 Mm Dia. Cond. 4/6 Quad Cables As Per Specn No. Irs: Tc-77/2012 (Rev.3.0) With Amend. 1, 2 & 3 Or Latest. , Supply Of Main Signal Post 140 Mm Outer Dia 4.6 Mtr Length As Per Specification No. Irs: S-6 With Latest Amendment. , Supply Of Cast Iron Main Signal Surface Base 140Mm As Per Specification No. Irs: S-10 And Drg No. S-2011/M With Latest Amendment, With Cls Ladder Assembly Complete And Ladder Base For Cls Signal 3.6 Mtrs/ 4.6 Mtrs./ 5.6 Mtrs. Long As Per Rdso Drg. No. Sa-23150/23153/23156 (Adv.) With Latest Amendment. This Also Include, Signal Front & Back Staging Complete Assembly For Cls Unit As Per Drg. No. Rst/11413. , Supply Of Non Metallic (Frp) Colour Light Signal Housing Multi Unit Type For Railway Signaling Suitable For Re Area Two Aspects. Complete Without Lenses, Lamps And Signal Transformer As Per Rdso Drg. No. Sa 23003A/M Adv. Alt- S And As Per Spec. No. Rdso/Spn/194/2006 (Rev 2.0) Or Latest And Frp Material As Per Rdso Spec. No. Rdso/Spn/151/1997 Or Latest. , Supply Of Shunt Signal Post Complete With Base. Gi Pipe, B Class Of 80Mm Dia. Of Min. 1 Meter Length To Be Supplied By The Contractor. , Supply Of Position Light Led Based Shunt Signal Unit (As Per Rdso Drg. No. Sa-23840). , Supply Of Off-Set Bracket 5-1/2 For Signals & Routes As Per Specification No. Irs: S-10/78 And Drg No. Sa-23080(Adv) Alt-1 Or With Latest Amendment. , Supply Of Retro Reflective Signal No. Plates As Perirsem Drg No. 19-D10 With Clamps, Nut, Bolts And Other Accessories Required For Fixing. , Supply Of Pad Locks 50 Mm With Common Key Make Godrej / Navtal Only. , Supply Of Apparatus Case With Miniature E Type Locks With Keys (1 Key Per 5 Location Boxes) Of Ward No. 41 (As Per Specification No. Irs: S-30/64 & Rdso Drg. No. Sa- 3376/M With Latest Amendments) On Both The Doors, Duly Painted With Red Oxide.-Single Case As Per Drg. No. Sk-783-1/2 & 2/2 With Latest Alteration. , Supply Of Resettable Fuse, Type Polymeric Positive Temperature Coefficient (Pptc) Fuse Of Make Littlefuse/Fuzetec,/Tyco/ Bourn/Raychem. Rating Of Fuse Will Be Provided By Consignee As Per Site Requirement. , Supply Of Cartridge Fuse Block Made Of Pbt As Per Rdso Drg. No. Sa- 23748 Alt. 4 And Spec. No. Irs-S- 75/2006 With Latest Ammendment. Fuse Block Shall Be Suitable For Round Head Type Fuses. (Material Inspected By Rdso , Supply Of Round Head Type Non Detoriating Type Low Voltage Cartridge Fuse As Per Specn No. Irs/S/78/92 With Latest Amendments 2A/4A/6A/10A Capacity. The Bifurcation Of The Fuses Shall Be Given By Site Incharge At The Time Of Execution Of Work. , Supply Of Earth Electrode Assembly As Per Drg. No. S&T/Con/Kota/Earthing/01 Alt- 01. All Nut, Bolts & Lugs To Be Of Stainless Steel. The Earth Electrode Pipe Shall Be B Class/ Medium Grade As Per Specification No. Is: 1239 Pt. 1/ 2004 Of Nominal Inner Dia 50Mm, Outside Dia (Max 60.8 Mm, Min 59.7 Mm), Thickness (3.6Mm), Tolerance In Thickness (+ Not Limited, - 12.5 Percent). , Supply Of Electric Point Machine Irs Make 110V Dc Operation (Ac Immunity 160V) Nontrailable, Complete With Lock, Detector, Cable Termination Box And Slides For Lock And Detector (Rotary Locking) As Per Specification No. Irs: S-24/2002 Amendment-1 Or Latest, Requirement Of Point Machine Is 143 Mm Throw Only As Per Rdso Drg. No Rdso/S-10800. , Supply Of Ground Connection Complete Set Suitable For Irs Type Point Machine For Ordinary Turnout Of 60 Kg Rails As Per Rdso Drg. Rdso-S-3361. , Supply Of G. I. Bend Pipe, B Class/ Medium Grade, 50 Mm Dia & 1.2 M Straight Length And Having Fixing Plate Welded With Bent Pipe As Per Drg. No. Dy.Cste(Con)/Kota/5 For Point Machine Cable Entry. , Supply Of Pre-Wired Crank Handle Cum Key Lock Relay Box (Of Metal) Along With Accessories Viz. Leds, With Approved Type Push Buttons, Terminal Strips, String Rod, Etc. As Per Drg. No. Dy.Cste/C/Kota/6 (A) & (B). , Supply Of William Stretcher Nylon Insulation Set Suitable For Ground Connection For Motor Point Operation. Each Set Comprising Of - (Rdso Drg. No.) T-10367-1 No.,T-10368- 2 Nos., T-10371- 4 Nos. And Conforming To The Specification Irs: S-23 & 40/84 With Latest Amendment. , Supply Of Gauge Tie Plate Nylon Insulation As Per Rdso Drg. No. (T-10372- 1 No., T-10368- 3 Nos., T-10371- 6 Nos. In Each Set) And To The Specification Irs: S-23 & 40 With Latest Amendment As Applicable. , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) End Plug , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) Cable Sealing Plug , Supply Of Hdpe Duct 40/33 Mm As Per Tec Gr/Cds/08-02 Nov- 04 Along With Following Accessories (To Be Procured From Rcil Approved Sources) Plastic Coupler , Supply Of Double Walled Corrugated (Dwc) Pipe Made Up Of High Density Poly Ethylene (Hdpe) Of Size 103/103.5 Mm Inner Dia And 120 Mm Outer Dia In 6 Mtr Straight Length As Per Britsh Standard No. Bsen 50086-1 And Bsen 50086-2-4 And Bis Draft Specification Doc No. Etd 14(5071) And Etd 14(5072) Along With One Coupler Per Every 6 Meters. , Supply Of 20 Pair Pvc Cable 0.5Mm Dia As Per Tech.Specn.G/Wir-06/03March 2002 Or Latest, Make Finolex, Polycab, Birla, Delton Or Havells , Supply Of 2-Zone Amplifier As Per Technical Spec. , Supply Of Vf Tapping Transformer470:600 Ohms To Rdso Spec No.Irs.Tc.22-76 Or Latest. , Supply Of Fiber Distributionmanagement System For 24Fiber Complete (48 Fibrescomplete Alongwith Euroadopters, Pigtail) Of Make Birla, 3M, Tvs, R&M, Orlatest Superior Make As Perinstruction Of Site Incharge. , Supply Of Cat-6 Shielded Cable. Make - Dlink Or Similar Reputed Make. , Supply Of Power Cable Pvc Insulated Flexible 3-Coremulti Strand Power Cable Of 2.5 Sqmm Shall Conformto Specification No.Is:694:1990 Or Latest. (Oemscompliance To Is 694 Is Required Along With Thedelivery For The Material) , Supply Of Vrla Fully Charged Battery 48 V Dc /300 Ah (Stackable) As Per Irs:S-93/96 (A)(Amd-1) Or Latest. , Supply Of 48V 25Amp ( 3+1 ) Fr/Fc Module Battery Chargerrdso/Spn/Tc/23/1999 Ver4.0 Amd1 Or Latest. , Supply Of 4 Port Lan Extender 30 Mbps Fast Ethernet On 4W/2W Configurable & It Should Support Ac And 48V Dc Power Supply As Per Rdso Specification No. Rdso/Spn/Tc/82/2020 Rev. 2.0 Or Latest. Make: Mrotek/Team Engineering/Cygnus Or Similar , Supply Of 32 U Way U-Link Panel With 32 Nos U Link Connector Of Protel Make Or Better. , Supply Of Ofc Patchcord/Jumper Cable Of Reputedmake/Brand, 10 M Long, With(1) Fc/Pc Connectors On Bothsides Or (2) One End Fc/Pcconnector And Other Endcompatible To Work With Stm-4. Insp. By Consignee. , Supply Of Maintenance Free Earth Consisting As Per Rdso Specification No. Rdso/Spn/197 Ver 1.0 Effective From 04.07.2016 Consisting Of Single Earth Pit Which Includes Supply Of 35 Mm²/16 Mm²/10 Mm²multistrand Single Core Pvc Insulated Copper Cable As Per Is 694 For Connecting Main Earth Electrode To Meeb In The Equipment Room Induplicate As Per Manufacturers Recommendations And As Per Rdso Specifications As Follow: (Material Inspected By Rites) (A) Supply Portion (B) Copper Bonded Steel Electrode Of 3.0 Meters Long, 17 Mm Diameter With Copper Bonding Thickness Of Minimum 250 Micronsand Ul Listed And Marked: 1 Nos. (C)Earth Enhancement Compound Of Rdso Approved Brand Supplied In Sealed Bag Of Minimum 10 Kg: 3Nos. (D) Copper Strip Of 150Mm X 25Mm X 6 Mm To Terminate Earth Rod:1 Nos. (E) Copper Strip Of 300Mm X25 Mm X 6 Mm (Meeb): 1 Nos. (F)Copper Strip Of 150Mm X 25 Mm X 6Mm (Meeb): 1 Nos. As Per Rdso Tan: Sts/E/Tan/3006 Dated 26.06.2025 , Supply Of Hylem Sheet Resin Bonded 10 Mm Thick , Grade P3 In Standard Size Of 1.22 X 1.22 Meter As Per Specification Is 2036 Of 1974 .Oem /Authorised Dealers Gaurantee Certificate To Be Submitted At The Time Of The Supply. , Preparation & Submission Of Cable Route Plan Of Main & Tail Cables, Cable Corage Plan And Location Particulars, Ct Rack Particulars,Ct Rack Vinay Flex, Meggering Report, Earth Resistance Particulars, Traction Bonding Diagram, Swrd. And Any Other Drawing / Particular Required In Auto Cad In Pendrive In Size As Per Requirement Of Drawing /Extant Practice Of Wcr. Each Sheet Should Have A Block For Signature Of Railway Officials As Well As Block For Signature Of The Firm, Where Signature Shall Be Put Up By The Authorized Signatory Of The Firm. The Name Of The Work As Given By The Railways Shall Be Written On Every Sheet Under The Work Column. One Complete Set Of Tracings And Four Sets Of Copies Of Complete Above Detailed Particulars / Drawings Along With One Pendrive To Be Supplied By The Contractor In Thick Plastic Folder. Item Will Be Per Station. , Preparation Of Swr Literature In English/Hindi Along With Associated Mid-Section Interlocked Gate With All Corrections As Per Approved Swrd & Approved Sip.For This All Technical Corrections,Editing, Grammatical Correction Etc. Are To Be Carried Out And One Rough Print To Be Given To Railways For Approval Before Printing, As Required For Final Processing Of Crs Sanction. This Alsoincludes Preparation Of Maintenance Cards In Format Provided By Rly. Item Will Be Per Station. , Making Photocopies & Binding Of Theswr Literature In English/Hindi /Diglotform As Per Railway Practice. , Printing And Installation At Site Of Vinyl Flex Of Free Size. This Includes The Supply Of 1 Check Print In A3 Or Suitable Size Of Paper To Railway For Checking And Approval. After The Approval Of Railway Officials, Supply And Installation Of Flex At Site Will Be Done By Contractor. , Supply Of Industrial Grade Inverter, Gallant Or Similar Reputed Make Of Adequate Capacity And In Numbers To Be Provided For Make System Configuration As Required For Site Specific Needs. Input:24 V Dc, Output:1 Ac/600Va, Pure Sine, Having Input Voltage Of 24V, Input Voltage Range 20V Dc --30V D, With Max Current Consumption Of 28A And Output Voltage 120V Ac +/- 2% 100 V Ac / 6A ---130V Ac/ 4,6 A) /230 V Ac +/- 2% (200V Ac/3A ...240V/2,5 A). Manual Selection Of Ac Output Voltage Via Single Terminal, Form Of Output Voltage Pure Sine. Real Power 480W, Mtbf ( Iec 61709)- 532525 H (40 °C), Screw Connection Conductor Size 0.2Mm2 ---4Mm2 , With Signal Output, Ambient Temperature (Operation) -- 25°C--- 60°C, Max Permissible Relative Humidity (Operation) 95% Shock-20G In All Directions (En 60068-2-27), Vibration (Operation) - 5 Hz -- - 100 Hz 0.7G (En 60068-2-6), Noise Immunity In Accordance With En 61000-6-2. Make:- Phoenix Contact Or Similar. , Supply, Installations, Wiring,Testing, And Commissioning Of Universal Earth Leakage Detector 8 Channel (3 Channel Card For Monitoring 110V Acand 5 Channel Card For Monitoring Dc Voltage 24V,24V, 60V, 60V & 110V) As Per Rdso Spn No.Rdso/Spn/256/2025 Ver 2.0 Or Latest. All Materials Required For Installations, Wiring,Testing And Commissioning Willbe Supllied By Contractor. Thematerial Should Be Supplied From Rdso Approved Source Only. , Supply And Installation Of Cabinet Console Unit Of Suitable Dimensions To House Vdu Control Terminal As Per Drg. No. 21-D5 Of Irsem (June-2021)-Appendix-Ii, Along With Cpu, One Set Of Input Device (Keyboard & Mouse Etc), Monitor (55 Inch) 4K Resolution And Power Supply Arrangements. The Detailed Drawings Of The Cabinet Along With Placement Of Various Equipments Inside The Cabinet Shall Be As Per Above Mentioned Drawings .Vdu Control Terminal Shall Be Approved By The Railway Engineer Before Supply. Note: Technical Requirements Are Attached Herewith. , Supply And Installation Of Covered/Secured Housing Cabinet Console Unit Of Suitable Dimensions To House Maintenance Terminal As Per Drg. No. Dy.Cste/Con/Kota/Vdu/01/ Alt. , Along With Cpu, One Set Of Input Device (Keyboard & Mouse Etc), Monitor (55 Inch) 4K Resolution And Power Supply Arrangements. The Detailed Drawings Of The Cabinet Along With Placement Of Various Equipments Inside The Cabinet Shall Be As Per Above Mentioned Drawings. Maintenance Terminal Shall Be Approved By The Railway Engineer Before Supply. Note: Technical Requirements Are Attached Herewith. , Supply ,Provision And Installation Of Permetric/Ring Earth (Maintenance Free Earth) Arrangemnt As Per Rdso/Spn/ 197/2016 Version 1.0 O Rlatest (With Latest Amendement). Number Of Earths Covering Entire Area Should Be Minimum 12. If Some Increase And Decrease In Number Of Earth , Proportionate Payment Will Be Made. Supply Of All Requites Material As Per Latest Rdso Guide Line. Earthing Shall Comply All Guidelines Specified Inrdso Tan No. Sts/E/Tan/3006 Dated 26.06.2025, (Unit -Per Station). , Installation Of Cable Termination Racks Assembly Complete Including Wall Supports, Scaffolding, Fixing Of 8 Way/ Ara/ Disconnect Screw Less, Spring Cage Type Terminal & Other Necessary Accessories Etc. The Work Shall Be Done As Per Approved Plan, Extant Practice On W.C. Railways & The Introduction Of Railway Engineer At Site. (All Fixing Material To Be Supplied By Contractor) As Per Typical Rack Arrangement Wcr Drg. No. S&T Eqpt. Bldg/2013/Pt. 1/4. The String Rod Shall Be Fixed On Phenolic Laminated Sheet. , Termination Of Cable Cores On Ara Terminal/ 8-Way/ Wago Terminals In The Cable Termination Rack. This Includes All Associated Works Of Pulling Out The Cable From Underground, Peeling Off Insulation, Dressing Of Cable Core With Lacing Thread Supported On String Rod With Contractors Own Material. This Includes Soldering & Earthing Of Armour Of Cables On Ct Rack. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site.Item Will Be Per Rack. , Wiring In Relay Room/ Auto Hut/ Ibs Hut/ Lc Gate Hut:- Plugging Of Q-Series Relay, Metal To Metal Relay/ Relay Groups. Energisation Of The System, Making The Panel Through, Functional Test As Per Control Table With Contractors Own Mock Panel, Break Test & Wire Count Test If Applicable To Be Done In Presence Of Railway Engineers. This Will Include Wiring Alterations Required If Any At That Stage, Preparation And Submission Of Wire Count Detail Register Etc. The Work Shall Be Done As Per Extant Practice On W.C. Railway & The Instruction Of Railway Engineer At Site. All Type Of Resistances, Capacitors Etc. Required For Commissioning Have To Be Provided By The Contractor Free Of Cost & Commissioning Of System After Testing. Item Will Be Per Rack. , Lettering & Numbering Of Detail And Description Writing Of Particulars Of Terminations & Equipments On Relay Rack, Relays, Cable Termination Rack, Battery & Power Equipments, Ips, Operating Panel, Axle Counter Etc. Constituting Entire System With Contractors Own Paint And Writing Material (Asian Make Or Similar Enamel Paints Or Similar Paint Only To Be Used). The Work Shall Be Done As Per Extant Practice On W.C. Railway & Instruction Of Railway Engineer At Site. This Also Include Writing Of Ct Rack Particular On Formica Sheet .Item Will Be Per Station. , Supply Of Conventional Lightening Protection System Consisting Of Franklin Rod Of 16Mm Dia, Single Prong Spike Made Of Copper Of Length 600Mm. Appropriate Reducer/Coupler For Connecting Franklin Rod And Gi Mast, Gi Mast Approximately 1.5-Inch Dia, 6 Mtr Length With Flanges For Installation Of Franklin Rod With All Supporting Accessories, Such As Guy Rope, U-Bolt, Thimble, Adjustable Clamp, D-Shakle, Hook Etc. This Also Includes Installation And Commissioning Of Conventional Lightening Protection System Consisting Of Franklin Rod, Appropriate Reducer/Coupler, Flanges And Gi Mast With All Supporting Accessories Such As Guy Rope (6 Mm Gi Wire), U-Bolt, Thimble, Adjustable Clamp, D-Shakle Hook, Etc. , Supply. Installation, Wiring And Commissioning Of Smps Based Integrated Power Supply System With (Vrla Batteries Of 55+5 Nos.) Spares And Tools As Per Rdso Specification No. Rdso/Spn165/2023 With Latest Amendment Applicable As On Date Of Tender Notice And As Per Drawing Provided By Railway At The Time Of Execution Of Work. Including Connection To Change-Over Unit Through Underground Cable Duly Supplied By Railway. For Connecting Ips To Battery Bank, Suitabe Length In Meter Each Of Red And Black Colour Cable Of Size As Per Battery Ah Capacity Is To Be Supplied By Tenderer. 12 Core X 1.5 Sq. Mm Signalling Cable For Connecting Ips To Status Monitoring Panel Will Be Supplied By Railway Free Of Construction Supply And Commissioning Of Ips Should Be As Per Rdso Letter No. Sts/E/Ips/General Dtd. 03.04.2008. This Includes Transportation, Loading And Unloading Of Ips System Complete And Batteries From Depot To The Site Of Installation. Erection Of Power Distribution Board & Its Connection To Ips, Bus Bars And Relay Racks In The Ips Room And Relay Room (As Per Site Engineer Instructions) With Contractors Own Wiring Materials. Lugs, Ladder, Dwc Pipe, 6/10/16/25 Sq Mm Power Cable As Per Load Etc. And As Per Requirement. This Also Include Fabrication And Fixing Of Ac/Dc Power Distribution Board Made Of Phenolic Laminated Sheet Erected On A Relay Rack (To Be Supplied By The Railways), All Connectors As Per Site Requirement To Be Supplied By Railway. Fan Will Be Supplied By The Railway. The Contractor Shall Liason Pursue/ Chase With The Ips Oem For Battery Charging And Commissioning Of Ips As Per Schedule. This Also Includes Supply Of Two Sets Of Power Cable Route And Equipment Plan For Ips And Relay Room. Spares Shall Be Supplied As Per Rdso Specifications. , Supply, Installations, Wiring, Testing, And Commissioning Of Networked Data Logger To Monitor 1536 Digital And 48 Analog Inputs. As Per Rdso Spec. Irs -S- 99/2006 (Amdt-3) With Latest Amendments And With Complete Accessories With Contractors Own Material. This Includes Power Supply For Adequate Capacity, Battery, Fault Diagnostic For Failure Analysis And Modem Card For Monitoring Data Logger , Complete Data Logger And Processor Module Shall Be Placed In Precedent Rack Of Suitable Siize To Be Supplied By The Contractor. Materials Also Will Be Supplied By Ontractor As Per Annexure. This Also Includes Programming Of Data Logger For Fault Diagnostic In Suitable Structured Language In Consultation With Rly. (512 Digital 32 Analog Input). This Also Includes Loading Of Networking Software And Networking Of Data Logger With Divisional Hq. The Requisite Communication Cable/Channel For Networking Will Be Arranged By Railway. , Installation, Testing, Commissioning And Supply Of Automatic Fire Detection & Alarm Complete System As Per Below Details-Supply, Installation, Testing & Commissioning Of Microprocessor Based Intelligent, Addressable, Modular, 1 Loop (Minimum 70 Detector/Devices Per Loop-Expandable To 2 Loops) Fire Alarm Control Panel With Lcd Display With 160 Character With Soft Keys For Displaying Alarm, Events And Operating Functions, Day/ Night Operation Function, Remote Maintenance Service Feature Etc. The Panel Should Be Multiprotocol Ie Able To Support At Least 2 Different Makes Of Addressable Detectors. The Panel Should Have Minimum Two Relay Outputs & 1 Monitored Sounder Output. It Should Have Provision To Be Connected To Repeater Panels In Future.The Panel Shall Capable To Operate On 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts, Sealed Lead Acid Maintenance Free Batteries Sufficient For 24 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During Emergency Condition. Panel Should Be Ul Or Fm Or Vds Or Lpcb Certified And Shall Comply To Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Manual Call Points, Push Type & Resettable With Key, With In-Built Isolator. Shall Be Ul Or Fm Or Vds Or Lpcb Compliant And Shall Comply To The Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Hooter Cum Strobe Complying To The Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Analogue Addressable Multisensor Detector With Multiple Sensitivity( Adjustable At Site) Levels , Programmable For Timed Automatic Sensitivity Selection With Base, And Other Accessories As Required And Detectors Shall Be Ul Or Fm Or Vds Or Lpcb Listed. The Detectors Shall Comply To The Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Resettable, Analogue Type Linear Heat Sensing (Lhs) Cable Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Lhs Interface Module With All Accessories For Single Stretch, Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. , Supply, Instalation, Testing And Commissioning Of Fire Survival Circuit Intrigity Cable Each Lot Having 200 Mtr. Cable With All Accessaries Connecting Of All Fire Alarm Devices As Per Rdso Rdso/Spn/217/2021 Rev.3.0 With Latest Amandment.The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Instalation, Testing And Commissioning Of Analogue Addressable Loop Powered Monitor Module With Inbuilt Isolator Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. (I) Zone Module = 02 Nos. Or (Ii)Realay Module = 02 Nos. Or (Iii) Monitor Module = 02 Nos. The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Analogue Addressable Loop Powered Control Module Fitted With Bi-Directional Inbuilt Isolator Providing Two Voltage Free, Single Pole, Change Over Relay Output, Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest.The Material Should Be Supplied From Rdso Approved Source Only. , Supply, Installation, Testing & Commissioning Of Isolator Device To Isolate The Circuit In Case Of Short Circuit, Complying To Rdso/Spn/217/2021 Ver 3.0 Or Latest. , Supply, Installation, Testing & Commissioning Of Aspiration (Airsampling Type) Detection Unit To Cover 5000 Square Feet Area Withall Accessories, Vds/Ul/Lpcb Approved, Complying Tordso/Spn/217/2016 Ver1. The Material Should Be Supplied From Rdso Approved Source Only. , S U P P L Y , Installation, Testing & Commissioning Of 2C 1.5 Sq Mm Twisted Shielded Armoured Copper Cable (Per Meter) With Accessories. , Supply Of Pvc Conduit Pipe Rigid Plain Ended Conduit Size 1 Inch (25 Mm) Is:9537 (Part-3) And 9537 (Part-1) 1980 With Latest Amendment Isi Mark With Minimum 1.2 Mm Wall Thickness & One Socket At Every 3 Meter Pipe. Make/Brand - Primco Plast Or Superior , Transportation And Fixing Of Pvc Conduit Pipe/Channel/Casing Caping On Wall Or Structure With Drawl Of ( One Or More No. Of) Telecom/ Power/ Data Cable With Proper Finishing. This Also Includes Concealed Wiring As Per Site Requirements And As Per The Directive Of Site Engineer. By Self. , Supply Of Gang Box ( For Multi Sensor Type Smoke Detector) , Execution/Fixing Of Gang Box.195 , Installation, Wiring, Testing & Commissioning Of Fuse Fail Indication Cum Monitoring And Automatic Change Over System. The Item Unit Will BePer Station.Cables Required For Execution And Installation Shall Be Supplied By Contractor At His Own Construction , Supply, Installation, Testing & Commissioning Of Universal Fail Safe Block Interface For Double Line. All Materials Like Wires/Lugs Etc. Will Be Supplied By The Contractor. - Each Set Constisting Of Following(I) Universal Fail - Safe Block Interface For Double Line Complete With All Accessories As Per Rdso Specification No. Rdso/Spn/147/2005(Amndt-1 Or Latest) Spec. No. Irs: S-104/2012 Ver.0 - 2 Nos. (Ii) Relay Rack With Due Locking & Sealing Arrangement Including Relays [Qn1-19 Nos., Qna1-07 Nos., Ql1 - 2 Nos., Timer - 1 No.] And Wiring As Per Wiring Diagram Rdso Drg. No. Rdso/S/32018 (With Latest Amdt.) - 2 Nos.(Iii) Block Panel Complete With Accessories As Per Rdso Drg. No. Rdso/S/ 32017 (With Latest Amdt.) - 2 Nos. (Iv) Block Telephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 - 2 Nos. , Supply And Installation Of D.P. 50 Pairs Krone Type Module Ms: 20 Swg , Supply And Insttaltion Of D.P. 20 Pairse Module Ms: 20 Swg , Supply And Installation Of D.P. 10 Pairs Krone Type With Krone Type Module. Ms : 20 Swg. , Splicing Of Optical Fiber Core And Routing In Joint Closure/Fdms As Per Instruction Of Site Engineer. Item Will Be Per Fiber. , Installalation Of Fdms With All Installation Materials,Restoration Wall Etc. To Original Condition Alongwith Splicing And Termination Of Optical Fibres 2X24 Fiber Cable,Routing/Dressing Fibers As Per Directions Of Site Engineer. , Supply And Fixing Of Rack 42U, 19 Inch Rack, Comrack, President Or Rittal Or Equivalent Make With With Full Front Glass Hinged Door , Cable Manager, 4 No Equipment Tray, 6 Pin Power Distribution Board , 4 Fan Cooling Fan Tray, Earthing Kit, 4 Nos Wheels Lock And Key And Other Accessories. , Supply And Installation Singleport Lo Box With Smb. Make :Anchor-Roma Or Equivalent.. , Supply And Installation Of Opticaljoint Enclosure Conforming Tordso Specno.Rdso/Spn/Tc/68/2014 Wwithrev.2.0 Or Latest Amendment Andsplicing Of Optical Fibre Cable (24F)And Testing Of Fibre For 1310&1550 Nm Shall Be Carried Outevery Joint Locations. , Supply, Installation, Testing And Commissioning Of Primary Digital Multiplexing Equipment (Pdmux) As Per Rdso Specification No Irs:Tc-68/2012 Rev.0 Amdt.1 Or With Latest Amendment Compatible To Webfil Made Pd Mux To Be Supplied By Rdso Approved Vendors And Their Authorized Vendors Only. , Supply, Installation & Commissioning Of 002 100/1000 Mbps Lan/04X2 Mbps Wan (04 Nos.G.703 Interface) As Per Specification No. Rdso/Spn/Tc/84/2008 Or Latest With Accessories. , Supply, Installation Of Maple 4C Or Equivalent 1U, 19 Inch Rackmountable Device Consisting Of Four E1 Ports And Three Slots And One Slot Populated With 2 W/4 W E& M Supporting Upto Eight Interfaces, Balance Two Slots Empty, Unit Shall Supports Both 230 V Ac / 48 V Dc Power Supply Including 50 Pin Cable One No. For Supporting Both 2W/4W E & W, Ac Adaptor One Number. Two Year Warranty. The Work Shall Be Done As Per Location Plans And Instruction Of Rly Engineer(Field Officer) At Site. All The Required Cable And Adaptor & Accessories Etc. Will Be Supplied Free Of Cost By Tenderer With The Satisfaction Of Railway Engineer At Site. Make- Mrotek, Realtime, Cygnus, Cisco Only.Specifications With Latest Software. , Supply And Installation Of Multi Telephone Way Station Equipment With Necessary Mounting Arrangement On Standard 19 Rack. It Shall Be (-) 48 Volt Operated As Per Rdso Specification No.Rdso/Spn/Tc/66/2007 With Latest Amendment. The Equipment Supplied In This Work Should Be , Excavation Of Trench 1.2 Mtr Deep, 300Mm Wide At The Bottom Along Main Line In Normal Soil, Including Clearing Of Bushes, Trees Etc And Refilling Of The Trench By Excavated Soil And Ramming After Laying Of The Required Quantity Of Cables As Per Instructions Of Engineer At Site. The Work Also Includes Excavation Of Trenches In The Beds Of Culverts. Whenever The Dimensions Of Cable Trenches As Mentioned In The Tender Schedule Are Not Easily Achievable Due To Terrain Conditions, Then Payments Will Be Made On A Pro-Rata Basis, For The Dimensions Achieved.The Specific Approval Of The Engineer In Charge Of The Work (Not Below The Rank Of Sr. Scale Officer), Will Be Required For Such Dispensation. , Excavation Of Trench As Per Cable Route Plan, 1.2 Mtr Deep, 500 Mm Wide At The Bottom Along Railway Track In Normal Soil. This Work Includes Covering Of Cables Laid In Trenches By Loose Excavated Soil For A Layer Of 50 Mm Thickness Approximately Before Covering By Shahabad Stone/ Bricks / Fly Ash Bricks/ Half Reinforced Cement Concrete Pipe, Clearing Of Route, Bushes Etc. And Refilling Of The Trench By Excavated Soil. Generally There Shall Be No Proportionate Payment For Cable At Depth Lesser Than That Specified In The Tender Schedule. If It Is Not Possible To Reach The Required Depth At Any Location, Then The Contractor Shall Obtain Prior Approval Of Site Engineer, Who Shall First Get The Dispensation, From Dy.Cste Vide Letter No. 2013/Sig/Sem Pt.- 1I/Misc, Dated 12.06.2014 Of Railway Board And Only , Excavation Of Trench As Per Cableroute Plan, 1 Mtr Deep, 300Mm Wide At The Bottom Along Main Linein Hard Soil / Murrum, This Workincludes Covering Of Cable Laid Intrenches By Loose Soil For A Layer Of50 Mm Thickness Approximatelybefore Covering By Bricks. , Excavation Of Cable Trench 1.0M Deep From The Rail Flange And 300Mm Wide Across The Track, For Track Crossing And Refilling After Laying Of Rcc/ Gi/ Dwc Pipes And Restoring The Track To Its Original Condition. Generally There Shall Be No Proportionate Payment For Cable At Depth Lesser Than That Specified In The Tender Schedule. If It Is Not Possible To Reach The Required Depth At Any Location, Then The Contractor Shall Obtain Approval Of Railway Site Engineer, Who Shall Get The Dispensation, From Jag Vide Rly. Boards Letter No. 2013/Sig/Sem Pt.-Ii/Misc., Dated 12.06.2014 Before Commencement Of Cable Laying Process And Only Then Shall The Proportionate Payment Be Made To The Contractor. The Work Shall Be Done As Per Extant Practice On W.C. Railway & Instruction Of Railway Engineer At Site. Cable Trench As Per Drg. No. Ts/Cable Laying/12/03/03 Alt.-1. For Achieving 1.0 Mtr Depth For The Bottom Most Cable, The Contractor Shall Dig The Trenches To A Depth, Slightly More Than 1.0M To Take Care Of Practical Problems. Laying Of Rcc/Gi/Dwc Pipe And Cables Is Covered In Separate Item. , Blowing / Drawing Of Ofc/6 Quad Through Hdpe Duct & Protective Work Already Provided In The Excavated Trench. All The Equipment And Machinery Required Shall Be Arranged By The Contractor At His Own Construction Cable Should Be Laid According To The Technical Conditions And Instructions Of The Site In Charge. Note: Ofc Will Be Supplied By Railway. , Transportation & Laying Of Hdpe Duct In The Trenches And In The Protective Works (I.E. Gi Pipes/Dwc Pipe/ Boring Etc.) And Supply As Well As Pulling Of Nylon Rope Through It At Different Places As Per Direction Of Engineer-In-Charge. This Also Includes Laying Of Duct In Track Crossings & Road Crossings Etc. Note-Hdpe Pipes Along With All Accessories Such As Couplers, Plugs, End-Plugs Etc., Which Are Required For Proper Laying & Fixing Of Hdpe Duct, Shall Be Supplied By Railways. , Supply & Laying Of Well Burnt Bricks Of Size 200Mm X 90Mm X 65Mm Inside The Trench (With The Brick Length Being Perpendicular To Cable Route) After Laying Of Cable & Covering Of Cables Laid In Trenches By Loose Excavated Soil For A Layer Of 50Mm Thickness Approximately, In Station Area From Outermost To Outermost Signal Or At Any Other Location As Per Instruction Of Site Engineer. Note:- Size Of Bricks To Be Got Approved By Railway Site Engineer. In Case Brick Size Is In Variance With The Size Given In The Tender Schedule Then Proportionate Payment On Volumetric Basis Shall Be Paid To Contractor Subject To A Maximum Limit Of Schedule Rate. , Laying Of All Types Of Signal/ Telecom/ Power Cable Of Various Cores/ Sizes In Excavated Trenches. The Work Shall Be Done As Per Extant Practice Followed On W.C. Railway And As Per The Instructions Of Railway Engineer At Site. , Installation Of Thermo-Shrinkable Jointing Kits For Making (A) Straight Through Joints Without Transformer For 6 -Quad Jelly Filled Cable, (B)Derivation Joint Without Transformer For 6-Quad Jelly Filled Cable, And (C)Straight Through Joint Without Transformer For10 Pr/20Pr. Pijfcables And Construction Of Brickchamber For Protection Of Joints Withcontractors All Materials As Per Drg.No. Given By Railway Where Vf Transformers Are Notrequired. All The Materials Required For The Work Are To Be Arranged Bythe Contractor Himself At His Own Cost Except Thermo-Shrinkable Jointing Kitwhich Is Already Covered In Supplyportion Of The Tender. After Jointingthe Cable Through Test Such Asinsulation Test, Continuity Cablelosses Etc. To Be Carried Out Jointlywith The Railway Engineer. If Anydefect Or Any Damage Observedduring Jointing, The Contractor Shouldredo The Joint Free Of Construction , Cutting Of All Types Of Roads (1 Mtr X300 Mm)/ Platforms (300Mm X 300Mm) Preparatory To Trenching, Excavation And Refilling After Laying Of Rcc/ Gi/ Dwc Pipe & Restoring Them To Original Condition. Generally There Shall Be No Proportionate Payment For Cable At Depth Lesser Than That Specified In The Tender Schedule. If It Is Not Possible To Reach The Required Depth At Any Location, Then The Contractor Shall Obtain Prior Approval Of Railway Site Engineer, Who Shall Get The Dispensation, From Jag Vide Rly. Boards Letter No. 2013/Sig/Sem Pt.-Ii/Misc., Dated 12.06.2014 Before Commencement Of Cable Laying Process And Only Then Shall The Proportionate Payment Be Made To The Contractor. This Also Includes Laying Of Any No. Of Dwc/Rcc/Gi Pipes, As Per Requirement. The Work Shall Be Done As Per Extant Practice On W.C. Rly & Instructions Of Railway Engineer At Site. The Dwc/Rcc/Gi Pipes Will Be Supplied By Railway. Laying Of Rcc/Gi/Dwc Pipe Is Covered In Separate Item. , Supply, Fixing, Painting And Installation Of Rcc/Stone Cable Route Markers As Per Drawing No. Drm/Kota/Misc-87 Or Wcr/Sig/St.Rt.Marker/201401. Placing And Securing Of Cable Route Markers In Trenches At The Specified Interval And Diversions, Joints Etc Along The Cable Route. The Work Shall Be Done As Per Extant Practice On W. C. Rly & The Instructions Of Rly Engineer At Site. Sample To Be Approved By Engineer In-Charge Of The Railways Before Supply, After The Testing Prescribed In Drawing. This Includes Supply Of Paints Of Different Colours As Per Drawing. The Paint Shall Be Either From Asi An Or Shalimar / Apcolite / Berger Having Isi Mark. , Fixing Of Ara/Cage Type Disconnect Terminals And Fuse Blocks With Provision Of Holes On Phenolic Laminated Sheets And Fixing With Galvanised Nuts & Bolts In Location Boxes And Elsewhere. This Includes Provision Of Additional Holes On The Phenolic Laminated Board On Either Side For Cable Conductor Entry. The Work Shall Be Done As Per The Instructions Of Railway Engineer At Site. , Termination Of Cable Cores On Ara Terminals/Cage Type Disconnect Terminals, Fuse Blocks, 8-Way Terminals Blocks, Telecom Terminals In New/Existing Apparatus Cases, Existing Mctb/Existing Telecom Cable Termination Racks. This Includes All Associated Works Of Pulling Out The Cable From Underground, Dressing Of Cable, Making Wiring Tree With Contractor Lacing & Threading Material Etc. Both Ends Of A Cable Core Shall Be Counted As Per Conductor. This Includes Soldering Of Armour Tree/Ring Of Cables And Connecting To Copper Plate Through Gi Wire Bus Bar In Location Boxes. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site. , Excavation, Casting (1:3:6) And Plastering (1:4, With Fine Sand) Of Main Signal Foundation As Per Drg. No. Dy.Cste/C/Kota/1 Alt A With Contractors Own Material Including Ballast, Cement, Local Available Sand, Pvc Pipe & Galvanised Anchor Bolts With Nuts & Washers, Etc. The Hole For Cable Entry Should Be Kept As Per Site Requirement And Instruction Of Railway Engineer At Site. The Required Ferma Of The Size Mentioned In The Drawing For Casting Of Foundation Will Have To Be Brought By The Contractor At His Own Construction All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Erection Of Main Signal (Cls) Post With Surface Base And Signal Unit Complete On Top Or On Off-Set Bracket, Fixing Of Front And Back Staging, Ladder, Guard, Signal Name Plates/Board, Protective Screen, Blanking Of Ladder (0.6Mm Ms Sheet), If Any With Contractors Own Brackets, Nuts & Bolts & Other Fixing Materials. This Also Includes Erection Of Auxiliary Signals Like Calling-On, Shunt Signal. Wooden White Cross-Arms (1000Mm X 100 Mm) To Be Provided By The Contractor Till The Signals Are Commissioned With Contractors Own Material. If The Ladder/Front/Back Staging Is Infringing The Sod, Then Suitable Arrangement Of Fixing Steps For Climbing Up To Signal Unit And Reducing The Size Of Front/Back Staging As Per Instructions Of Site Engineer Shall Be Done. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Termination Of Tail Cable On Main & Auxiliary Signal Units And Wiring With Contractor Own Material, Fixing Of Led Signal Units Etc. Flexible Single Core Copper Wire 2.5 Sq.Mm (50/0.25) Conforming To Is-694:1990 (As Per Aspect Colour) And Lugs Etc. Will Be Supplied By The Contractor. This Includes Insertion Of Tail Cables From Ground To Signal Unit, Thereafter Sealing The Opening And Testing The Signal As Per Instructions Of Railway Engineer At Site. , Excavation, Casting (1:3:6) And Plastering (1:4, Fine Sand) Of Shunt Signal Foundation As Per Drg. No. Dy.Cste/C/Kota/1 Alt A With Contractors Own Material Including Ballast, Cement, Local Available Sand, Pvc Pipe & Galvanised Anchor Bolts With Nuts & Washers, Etc. The Hole For Cable Entry Should Be Kept As Per Site Requirement And Instruction Of Rly Engineer At Site. The Required Ferma Of The Size Mentioned In The Drawing, For Casting Of Foundation Will Have To Be Brought By The Contractor At His Own Construction All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Erection Of Shunt Signal Post With Surface Base, Unit, Number Plate Complete. Wooden White Cross-Arms (1000Mm X 100 Mm) To Be Provided By The Contractor Till The Signals Are Commissioned With Contractors Own Material. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. , Termination Of Tail Cable On Shunt Signal Units And Wiring With Contractors Own Material, Fixing Of Led Signal Unit Etc. Flexible Single Core Copper Wire 2.5 Sq.Mm (50/0.25) Conforming To Is: 694:1990 Copper Wire As Per Railway Standard And Lugs Etc. Will Be Supplied By The Contractor. This Includes Insertion Of Tail Cables From Ground To Signal Unit, Thereafter Sealing The Opening And Testing The Signal As Per Instructions Of Rly Engineer At Site. , Excavation And Casting Of Apparatus Case Foundation With Mixture Of Cement:Sand:Stone Aggregate/Chip In 1:3:6 Ratio And Plastering With Mixture Of Cement:Sand In 1:4 Ratio, With Contractors Own Metal Sheet Ferma Of The Size Mentioned In The Drawing, Cement, Anchor Bolts, With Nuts & Washers And Other Materials. The Items Also Include Additional Earth Work If Required As Per Instruction Of Rly. Engineer At Site. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. -Single Case Drg. No. Sk 783-1/2 With Latest Alterations , Erection Of Apparatus Cases. This Includes Filling Of Location Foundations With The Seived Sand Being Used For Making The Foundation Of Location Boxes And Plastering On Top Of The Sand. All Nuts, Bolts And Washers Etc. Should Be Galvanised Iron. -Single Case , Supply, Fabrication And Fixing Of Phenolic Laminated Sheet Board In Location Box By Providing All Fixtures, Double Ended Insulators (06 Nos.), Pvc Coated String Rods At The Back Side For Cable Support With Contractors Own Material. The Work Shall Be Done As Per Drg. No. Sk 783-1/2 With Latest Alterations & As Per Instructions Of Railway Engineer At Site. The Phenolic Laminated Sheets Should Be Of 10Mm Thick, Grade P3 As Per Specification No. Is: 2036 Of 1995 Or Latest. The Size Of The Phenolic Laminated Sheet For Full Case Terminal Board Should Be 800Mm X 950Mm And For Half Case It Should Be 800Mm X 450Mm. In Case Board Size Is In Variation With The Size Mentioned As Per Location Details, Then Proportionate Payment On Area Basis Shall Be Made. This Also Include, The Work To Be Done In Existing Location Boxes (If Required) As Per Instructions Of Railway Site Engineer. - Single Case , Supply, Fabrication And Fixing Of Phenolic Laminated Sheet For Shelf Of Equipments/Batteries With Contractors Own Fixing Material, Angle Frames, Additional In-Between Supporting Angle For The Shelf, Etc. The Work Shall Be Done As Per Drg. No. Sk 783-1/2 With Latest Alterations & As Per Instructions Of Railway Engineer At Site. The Phenolic Laminated Sheets Should Be 10Mm Thick, Grade P3 As Per Specification No. Is: 2036 Of 1995 Or Latest. The Size Of Shelf For Single Case Apparatus/Location Box Shall Be 500Mm X 950Mm And For Half Case Location Box It Shall Be 500Mm X 450Mm. In Case Board Size Is In Variation With The Size Mentioned As Per Location Details, Then Proportionate Payment On Area Basis Shall Be Made. Galvanised Nut & Bolts To Be Used For Fixing Of Phenolic Laminated Sheets.-Single Case , Installation Of Equipments (Relays, Resistance, Chargers, Choke, Batteries, Lv Box, Klcr, Pptc Fuses & Track Feed Charger Alarm Unit, Etc. As Applicable) With Contractors Own Wiring Material, Ms Frame, Copper Lugs Etc. & Wiring Of The Same In Apparatus Cases As Per Location Diagrams, Paralleling Of Spare Contacts Of Metal To Carbon Relays And Wiring Of Potential Free Contact Of Track Feed Charger And Testing Of Track Circuits As Per Instruction Of Railways Site Incharge And Standard Practice. This Also Includes Supply Of Multi-Strand Flexible Single Core Copper Wire 2.5 Sq.Mm (50/0.25) Except For Relay Wiring Which Will Be Done With 16/0.2 Mm Flexible Multi-Strand Wire Conforming To Is: 694:1990 With Suitable Lugs. All Wires To Be Duly Manufactured By Rdso Approved Firms (16/0.2 Mm Flexible Multi-Strand Wire Inspected By Rdso). Note: Pptc Fuses Shall Be Provided As Per Fixing Arrangement Of Pptc As Advised By Hqs Policy Guideline Issued Vide Letter No. Wcr/N-Hq/110/Signal Policy/Sig-32 Pt-Vii, Dtd. 07.11.2013 I.E. Pptc Fuse Are To Be Connected With Crimped Ring Type Lugs And Crimped Area Is Also To Be Filled With Solder. Pptc Lead To Be Provided With Ferrules For Volt & Current Rating Of Pptc. Ferruling For Cable Terminations In Location Box Shall Be Done By Contractor With His Own Cost.-Single Case , Installation Of Earth Electrode Assembly As Per Drg. No. S&T/Con/Kota/Earthing/01 Alt-1 And Connecting Through Stainless Steel Wire 8 Swg Supported On Ms Flat Of Size 5Mm X 40Mm To Earth Electrode As Per Drg. No. T/2014/1 For Signals And T 2014/5 For Location Boxes/Apparatus Cases. The Earth Value Should Be Less Than 10 Ohms Including The Lead Wire. The Value Should Be Measured In Presence Of Railway Supervisors. It Should Be Documented And Painted On Earth Enclosure Made Of Concrete. Only Earth Electrode Will Be Supplied By Railway. All Other Material Required For Provision Of Earthing Will Be Brought By The Contractor. This Earth Can Be Provided For Dps, Block Instruments & Eld Etc. Also, So As To Achieve The Desired Earth Resistance Value. Earth Enclosure To Be Manufactured & Supplied By Contractors Own Material Of Ratio 1:3:6, Without Cover. Additional Connection Of Earth Pipe Including Parallel Connection With Other Earth Pipes With The Function Shall Be Done Using Left Over Pieces Of Signalling Cable. Laying Of Cable Pieces Shall Be Covered In Laying Of Cable Item And Cable Shall Be Supplied By Railways. , Supply & Installation And Testing Of Maintenance Free Earth Consisting As Per Rdso Specification No.Rdso/Spn/197 Ver.1 Effective From 04.07.2016 Consisting Of Single Earth Pit Which Includes Supply Of 35Sq. Mm / 16 Sq.Mm / 10Sq.Mm Multistrand Single Core Pvc Insulated Copper Cable Asper Is 694 For Connecting Main Earth Electrode To Meeb In The Equipment Room In Duplicate As Per Manufacturers Recommendation And As Per Rdso Specification As Follows: As Per Drg Nosdo/Rdso/E&B/001 Dated19.09.08Set223471.48 A)Copper Bonded Staeel Electrode Of 3.0Meter Long,17Mm Dia With Copper Bonding Thickness Of Minimum 250 Microns And Ul Listed Andmarked - 1No. B) Earth Enhancement Compound Of Rdso Approved Brand Supplied In Sealed Bag Of Minimum 10Kg. - 3Nos. C) Copper Strip Of 150 X 25 X 6Mm To Terminate Earth Rod - 1No. D) Copper Strip Of 300 X25 X 6 Mm (Meeb) - 1No. E)Copper Strip Of 150 X 25 X 6Mm (Seeb) - 1No. F)Digging/Auguring/Borring Ofsingle Earth Pit Of 100Mm To125mm Dia To The Depth Of Approximate 2.8M G) Insertion Of 3 Mtr Electrode And Penetrating It At Least 0.2 Mtr. By Pushing Gently With Sledge Hammer Where The Neutral Soilis Assumed. H) Filling Of Earth Pit With Earth Enhancement Compound (Eec) In Slurry Form And Back Filling. I)Carrying Out Exothermic Weld Connection Of Single Earth Electrode To A Copper Tape Of150 X 25 X 6 Mm J) Carying Out Exothermal Weld Connection On The Copper Tapeof 150 X 25 X 6 Mm On Earthe Electrode For Connecting Two35 Sq.Mm Cable For Redundancy K) The Exo Thermal Welding Material For Bonding The Earth System Shall Be Procured From Rdso Approved Firms Which Include Graphite Moulds, Clamps, Weld Metal Powder. L) 300 X 300 X 300Mm (Inside Dimensions)Concrete Earth Pit With Aconcrete Lid Approximately50mm Thick With Pulling Hook Sshall Be Provided To Cover Thepit. Back Side Of The Cover Willbe Painted In Black And Date Of Testing And Average Resistance Value Shall Be Written.The Item Should Be Executed As Per Latest Rdso Tan: Sts/E/Tan/3006 Dated 26.06.2025 , Installation Of Maintenance Freee Earth In Rocky Area As Per Item Supplied Againstwith Contractors Own Materialsrequired For The Same. This Includes :I. Digging/Auguring/Boring Of Single Earth Pit Of 100Mm To 150Mm Dia Tothe Depth Of Approximate 3 M In Rocky Area. Ii.Nsertion Of 3 Mtr Electrode Andpenetrating It At Least 0.2 Mtr. Bypushing Gently With Sledge Hammerwhere The Neutral Soil Is Assumed.Iii.Filling Of Earth Pit With Earthenhancement Compound (Eec) Inslurry Form And Back Filling. Iv.Fillingof Earth Pit With Earth Enhancementcompound (Eec) In Slurry Form Andback Filling. V.Carrying Outexothermic Weld Connection Of Singleearth Electrode To A Copper Tape Of150 X 25 X 6 Mm Vi.Filling Of Earthpit With Earth Enhancementcompound (Eec) In Slurry Form Andback Filling. Vii.Carrying Outexothermal Weld Connection On Thecopper Tape Of 150 X 25 X 6 Mm Onearth Electrode For Connecting Two 35Sq.Mm Cable For Redundancy Viii.Theexothermal Welding Material Forbonding The Earth System Shall Beprocured From Rdso Approved Firmswhich Include Graphite Moulds,Clamps, Weld Metal Powder. Ix.300Mm X 300 Mm X 300Mm(Insidedimension) Concrete Earth Pit With Aconcrete Lid Approximately 50 Mmthick With Pulling Hooks Shall Beprovided To Cover The Pit. Back Sideof The Cover Will Be Painted In Blackand Date Of Testing And Average Earthresistance Value Shall Be Written. , Fixing/ Refixing Of Electrical Point Machine On Existing Layout, Ground Connection During Phase Working (Ni/ Pre-Ni) After Removing The Electrical Point Detector, Fpl Assembly And Mechanical Or Any Other Fittings Including Existing Point Machine Fitting If Any, Adjustment If Necessary, Wiring Of Point Machine Testing And Commissioning Of Electrically Operated Point, Fixing And Connecting Point Indicator On Derail Switch If Necessary. This Will Include Fabrication And Fixing Of Gi Bend Pipes As Per Drg. No. Dy.Cste(Con)/Kota/5 Of S-Shape Of 1.2 Meter Length & 50Mm Dia With Welded Frame For Cable Entry To The Point Machine And Termination Of Tail Cable In Point Machine And Wiring Servicing Of Point Machine & Supply And Filling Of Sae-30 Lubrication Oil . This Also Includes Installation Of William Stretcher Nylon Insulation Set (Complete), Tongue Attachment Nylon Insulation Set And Guage Tie Plate Nylon Insulation Set As Per Rdso Specification. The Work Shall Be Done As Per Extant Practice On W.C. Railway And The Instructions Of Railway Engineer At Site. Internal Wiring Of Point Machine & Cable Termination Suitable For Ei/Pi/Rri Installation, 2.5 Sq.Mm (50/0.25) Conforming To Is: 694:1990 Flexible Copper Wire Of Different Colours & Lug Will Be Supplied By Contractor. Point Machine, Ground Connection, Insulation Sets Will Be Supplied By Railways. This Includes Drilling Of Holes In Tounge Rail, Provision Of High Di-Electric Varnish On Contact Assembly And Wiring During Ni Period. This Also Include Rewiring Of Point Machine If Required As Per Type Of Point Machine & Circuit (Independent Detection) & As Per Instruction Of Site Engineer. To Reduce The No. Of Days Of Ni, The Existing Point Machines May Be Replaced With New Point Machines And Operated From Existing Panel. During Pre-Ni / Ni, Rewiring At Mctb/Location Box/Point Machine Shall Be Carried Out As Per The Requirement Without Any Additional Construction Item Will Be Per Point. , Supply & Fixing Of Klcr Boxes & Fixing Of Klcr Relays. It Includes Supply Of Any Minor Bracket, Nuts, Bolts,Teakwood/Metal, Sun Mica,Paint, Lock, Drilling Hole Etc As Directed By Engineer At Site. It Also Includes Supply And Wiring Of Push Buttons Along With Leds For Klcr Circuit. Rly Will Supply Only Klcr Relays And Contractor Has To Wire Klcr Relays. It Includes Supply Of All The Related Wiring Material. , All Work Pertaining To Horizontal Dirctional Drilling (Hdd)/Boring And Trenchless Cabling. It Includes Supply, Transportation And Insertion Of Self Lubricated Hdpe Pipe And Laying Of Cables In Boring Under The Track/Road/Platform/Circulating Area By Using Different Sizes Of Pipes Depending On Total Number Of Cables Will Be Crossed. The Depth Of Horizontal Boring Should Be Minimum 1 Mtr Upto 3 Mtr, From Rail Flange/ Road Level/Ground Level As Per Site Requirement And As Per Instructions Of Railway Engineer Incharge. This Item Will Be Used For Track Crossing Of Running Lines, Road Crossing & Circulating Area. By Using Self Lubricated Hdpe Pipe Of 120Mm Outer Dia And 103.5Mm Inner Dia In The Bore And Laying Of Cables In The Bore Under The Track/Road/Circulating Area. , Preparation Of Cable Duct 150Mm X 300Mm Deep For Laying Of Cables In Rocky Area And Refilling The Duct (After Cable Laying) With Concrete Mixture Of Proportion 1:3:6 And Grouting The Ends At Either Side Of The Rocky Portion Using Concrete Mixture With Contractors Own Cement And Other Materials. Cable Trench Shall Be As Per Drg. No. Dy.Cste/C/Kota/07/A. Laying Of Cables Is Covered In Separate Item. , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Apparatus Case Full Size , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Point Machine With Ground Connection Complete. (Point Machine With Black Enamel Only Outside And Ground Connection With Red Oxide) , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Main Signal Post With Main & Auxilliary Signal Unit, Surface Base And Complete Fittings As Per W.C. Railways Standard Practice. , Painting Two Coats Of Enamel Paint Over One Coat Of Red Oxide Primer On The Following Items After Scrapping And Cleaning Of The Surface Wherever Necessary. Primer And Paints With Isi Mark Is To Be Supplied By The Contractor. The Work Shall Be Done As Per Instructions Of Railway Engineer At Site And Extant Practice On W.C. Railway. Note: Second Coat Shall Be Made After Completely Drying Up Of First Coat Of Paint, To Give Good Somooth & Lasting Finish.-Shunt Signal Post With Signal Unit, Surface Base As Per W.C. Railways Standard Practice. , Lettering, Numbering Of Point Machine, Track Lead Junction Boxes, Block Joint, Glued Joints, , Batteries, Apparatus Cases Etc. (Outside) (Each Item To Be Taken As One Unit ) , Lettering & Numbering Of Termination Particulars, Equipments Names Etc. Legibly And Neatly Inside Location Boxes As Per Standard Practice Of W.C. Railway & Instructions Of Railway Engineer At Site.-Single Case , Cement Concrete 1:3:6 In Foundations With Upto 25Mm Graded Stone Aggregate As Per Instructions Of Railway Engineer At Site. , Provision Of Temporary Gumti Of 3Mtr X 3Mtr X 2.5Mtr On Hire For Ni Working Made Of Water Proof Tent (Coverd On Three Sides Of Wall) With Provision Of Good Quality Turpolene Mat Laid Inside Full Floor Area Of Tent, Two Tables, Two Chairs, Water Dispenser With 5 Mineral Water Bottle Refills Of 20 Ltr Each And Two Incandescent Lamps/ Emergenvy Light As Per Instructions Of Railway Engineer At Site. (Electrical Connection Will Be Provided By Railway). (01 Numbers= 01 Gumti Per Day) , Releasing Of All Equipments Of Relay Room/ Axle Counter Room/ Ips Room/ Battery Room / Asms Room/ Esms Duty Room / Data Logger Room, Cabin Basement And Lever Frames, Covering The Entire Indoor Signaling Gears As Per The Instruction Of Railway Engineer At Site & Their Transportation To Sse/Sig/Kota Depot With Ms/ Ci/ Wooden Materials Duly Seggregated. The Above List Is Only Indicative, The Contractor Has To Release All Old Equipments As Per Pre Commissioning Survey And Instruction Of Railway Site Engineer. , Installation, Transportation, Wiring , Testing And Commissioning Of High Frequency Digital Axle Counter Multi Section Type Complete System Including Central Evaluator(S), Final Track Clearance Relay For Each Track Section, Reset Boxes, Lv Boxes, Detection Points, Mushroom Housing For Track Side Electronics, Earthing Arrangement (If Any As Per Oem Requirement) And All Other Accessories Fully Wired To The Ultimate Capacity And Fully Equipped To The Configuration Specified As Per Rdsos Specification No. Rdso / Spn / 176 / 2013 (Ver. 3) Or Latest And Oem Specification. This Also Includes Installation Of Track Device (Double Rail Contact) Including Digging Of Trench, Fixing Of Deflector Plates, Track Crossing, Laying Of Ant Rodent, Anti-Oxidant & Non -Flame Propagating Type Double Walled Corrugated (Dwc) Pipe Made Up Of High Density Polyethylene Of Required Dia, As Per Is-14930 Part-I Or Ii Or Latest And All Other Accessories As Per Site Requirement For Laying Of Transmitter And Receiver Cable, Installation Of Ejb/Track Side Electronics Including Foundation & Installation Of Earthing (If Any) As Per Oems Guidelines, Technical Requirement & Specification. , Supply Of High Power Main Signal With Led Aspect Integrated Type, Current Regulator As Per Rdso Specn. No Rdso/Spn/199/2025 (Rev. 1.2) Or Latest. - Red , Supply Of High Power Main Signal With Led Aspect Integrated Type, Current Regulator As Per Rdso Specn. No Rdso/Spn/199/2025 (Rev. 1.2) Or Latest. - Yellow , Supply Of High Power Main Signal With Led Aspect Integrated Type, Current Regulator As Per Rdso Specn. No Rdso/Spn/199/2025 (Rev. 1.2) Or Latest. - Green , Supply Of Calling On Unit Led Integrated Type As Per Rdso Specn. No Rdso/Spn/153/2023 (Rev. 5). Or Latest. , Supply Of Led For Shunt Signal Integrated Type As Per Rdso Specn. No Rdso/Spn/153/2023 (Rev. 5). Or Latest.
Basic Detail
Tender No C-2(b)/RC/0910/2627/057
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 28 Oct 2026
Submission Date 12 Nov 2026
Open Date 12 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 3.28 Lakhs
Exemption Available
Document List
53079036-c986-4d92-9dc0-7a29a662fbbb.html
BOQ_345043.xls
TD057.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Nov 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

53079036-c986-4d92-9dc0-7a29a662fbbb.html

xls

BOQ_345043.xls

pdf

TD057.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender