Tender For Tnpgcl - Nctps Iii - 1 X 800 Mw Super Critical Boiler - Mechanical Ii Circle - Turbine Maintenance Division-Overhauling And Servicing Of Condenser Debris Filter System And Coltcs Outlet Screen, Condenser Inlet And Outlet Bfvs (4Nos.) Durin
Tender Overview
Project Description
Tender for Tnpgcl - Nctps Iii - 1 X 800 Mw Super Critical Boiler - Mechanical Ii Circle - Turbine Maintenance Division-Overhauling And Servicing Of Condenser Debris Filter System And Coltcs Outlet Screen, Condenser Inlet And Outlet Bfvs (4Nos.) During Aoh 2026-2027
BOQ
| Sl. No. | Item Description |
| 1 | Overhauling and Servicing of debris filter systemcharges for Removing of manhole doors, removal of drive shaft, bush bearing couplers, rotating arm for debris filter motor (A/B) |
| 2 | charges for Removing of gear box supporting arm gear box dummy plate, removal of planetary gear box and taken out side for debris filter motor (A/B) |
| 3 | charges for fixing of Nut, ring, shaft seal, refixing of planetary gear box in its position, drive shaft, gear box dummy plate, drum fixing supports, flushing arm assembly |
| 4 | charges for fixing of bush bearing assembly, gear drive shaft assembly, final alignment at planetary gear box, fixing of gear drive motor etc |
| 5 | charges for closing of manhole doors and opening of inlet and outlet valve, commissioning the system for normal operation |
| 6 | Overhauling and Servicing of COLTCS outlet screencharges for inspection, Cleaning and aligning of OLTCS ball collection screens: Opening of OLTCS system outlet ball collecting screen manhole doors in cooling water outlet line 2Nos and cleaning the debris in collecting screen, aligning of ball collecting screens and closing manhole doors with renewal of gasket. |
| 7 | Overhauling and Inspection of rubber seal in 2400mm Discharge Butterfly Valve (BFV) of Cooling Water pipe line , 2220mm(OD) Condenser inlet and outlet BFV’s(4Nos.)Charges for opening the manual doors, cleaning the flab of butterfly valves, inspecting, checking the clearance of rubber seal and adjusting as necessary and closing the manual doors in the discharge line of Condenser inlet and outlet |
| 8 | Charges for Dismantling 2400mm BFV gearbox, inspection of internals, renewal of seals, grease , re assembling and checking the Open/Close operation of BFV. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender