Power Boards / Undertakings / PSU Closing in 17 days TDR #58253279

Bids Are invited for Custom Bid For Services - Electrical Wiring Of Residential And Non-Residential Parking Garage Of Urja Vihar Colony Of Omkareshwar Power Station - Point Wiring Surface Rigid P.V.C. Conduit: Point Wiring (Excluding Metallic Switch

Issued by Boards / Undertakings / PSU · East Nimar, Madhya Pradesh
Tender Value
19.10 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
17 days left
EMD
38000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Nimar → Madhya Pradesh
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Custom Bid For Services - Electrical Wiring Of Residential And Non-Residential Parking Garage Of Urja Vihar Colony Of Omkareshwar Power Station - Point Wiring Surface Rigid P.V.C. Conduit: Point Wiring (Excluding Metallic Switch Box & Sheet But Including Switches, Sockets, Lamp Holders/Ceiling Roses Etc) With 1.5Sq. Mm. Pvc Insulated Cable Fr-Lsh With Copper Multistrand Conductor Isi Marked In Surface Rigid P.V.C. Conduit (Mms) Isi Marked Of Suitable Size And 1.5Sq. Mm. Pvc Fr-Lsh Insulated Copper Earth Continuity Conductor Of Green Colour Inside Conduit Etc. As Required As Per Specification For : Light Point/Fan Points : Primary Short Point , Same Board : Same Board Switch & Socket 16 ./S.S. Combined 20/16/6 , Sub-Mains In Surface Rigid Pvc Conduit (Mms) :Wiring For Sub-Mains With Pvc Insulated Cable Frls With Copper Multi Strand Conductor Isi Marked In Surface Rigid Pvc Conduit (Mms) Isi Marked Of Suitable Size (Conduit Included) Including 2Mm Thick Accessories, Connection Etc,As Required As Per Specification. (Refer General Notes For Classification Of Conduit Wiring Point No.8 - As Per Amendment - 20.03.2024) . 3 Wire , 3 Wire Sub Main, 4.0 Sq. Mm. Cable , Mcb C Series, 240/415V, 50 Cycle, 10Ka/15Ka : Supply Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker (Mcb) Of C Series With Short Circuit Indication, Suitable For 240/415 Volts,50 Cycle, 10 Ka/15 Ka Value Ac Supply Conforming To Is : 8828 : 1996, Iec : 60898 :2002 & 60947-2 But Without Enclosures :- Double Pole : Mcb Dp 6 To 32 10Ka Rating , Mcb C Series, 240/415V, 50 Cycle, 10Ka/15Ka : Supply Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker (Mcb) Of C Series With Short Circuit Indication, Suitable For 240/415 Volts,50 Cycle, 10 Ka/15 Ka Value Ac Supply Conforming To Is : 8828 : 1996, Iec : 60898 :2002 & 60947-2 But Without Enclosures , Triple Pole, Mcb Tp 6 To 32 10Ka Rating , Mcb C Series, 240/415V, 50 Cycle, 10Ka/15Ka : Supply Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker (Mcb) Of C Series With Short Circuit Indication, Suitable For 240/415 Volts,50 Cycle, 10 Ka/15 Ka Value Ac Supply Conforming To Is : 8828 : 1996, Iec : 60898 :2002 & 60947-2 But Without Enclosures : Mcb Sp 6 To 32 10Ka Rating , Fixing Of Mcb/Mccb/Isolator, (Labour Only) : Fixing Of Mcb/Mccb/Isolator In Sheet Steel Enclosure As Required Asper Accepted Practice, Including Mounting Onbusbar And Cable Connection Etc. Complete (Labour Only): Mcb/Isolator Sp/Dp , Fixing Of Mcb/Mccb/Isolator, (Labour Only) : Fixing Of Mcb/Mccb/Isolator In Sheet Steel Enclosure As Required Asper Accepted Practice, Including Mounting Onbusbar And Cable Connection Etc. Complete (Labour Only) : Mcb/Mccb Isolator Tp/Tpn/Fp , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 4 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 6 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 8 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 12 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 16 Way Double Door Ip 43 Protection , Labour Charges: Labour Charges For Fixing Sheet Steel Enclosure,Mcb Db Surface Mounting Type, As Per Accepted Practice On 25X5mm Flat Iron Clamp Duly Embedded In Wall, Cable Connection Etc. Complete. For Item No : 27.11.1 To.27.11.4 , Labour Charges: Labour Charges For Fixing Sheet Steel Enclosure,Mcb Db Surface Mounting Type, As Per Accepted Practice On 25X5mm Flat Iron Clamp Duly Embedded In Wall, Cable Connection Etc. Complete. For Item Sor No : 27.11.5 & 27.12.1 To 27.12.2 , Labour Charges: Labour Charges Fo Rfixing Sheet Steel Enclosures,Mcb Db Surface Mounting Type, As Per Accepted Practice On 25X25x5 Mm Angle Iron Clamp, Including Supplying And Fixing Of Clamp Duly Embedded In Wall, Cable Connection Etc. Complete : For Item Sor No 27.11.6 & 27.11.7; 27.12.5 ; 27.13.2 To 27.13.4 & 27.14.1 To 27.14.4 ; 27.15.1 To 27.15.4 , Led Tube Rod Fixture : Supply And Fixing Led Tube Rod Comprising Of Led Tube With Non Integral / Integral Driver, Upto 6500K Color Temp Having 40000 Burning Hrs Life With Minimum @ L70, System Lumen Output Should Be Minimum With System Efficacy >100Lm/Watt. Leddriver Pf>0.95 & Thd<20%.The Colour Rendering Index Of Led Light Should Be More Than 70. Submission Lm79-08/Is16106 (2012), Iec60598, Iec61347 I/C Connection Wire, Testing Etc. To Complete The Job. Tube Light Led 1 X 18W Tube Light Led 1 X 18Watt, Integral I/C Batten Aluminium Body, Pc Diffuser. , Modular Pvc Box (Surface) : Supplying And Fixing Of Approved Make Modular Type Pvc Box Minimum Depth 40Mm And Minimum Thickness 2Mm With Modular Base And Cover Plate Including Fixing On Surface Etc. As Required For:- 4 Module Pvc Box , Xlpe Insulated Power Cable, Al. Conductor : Supply Of Xlpe Insulated Power Cable(Conforming Is-7098 Part-I) 1100 Volt Grade, 1 Core/2 Core/3½ Core/4 Core Isi Marked With Alu. Stranded /Solid Conductor , 3½ Core Armoured : 25 Sq. Mm , Cable Laying : 1.1Kv Grade Of Size Not Exceeding 25 Sq. Mm : Laying Of One Number Rmoured / Unarmoured Power Cable1.1Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In All Soil/ Murrum /Soft Rock, Sand Cushioning, Protective Covering And Refilling The Pit Etc. As Required. , Double Wall Corrugated Pipes (Dwc) Of Hdpe : Supplying And Installing Double Wall Corrugated Pipes (Dwc) Of Hdpe (Is 14930 Part Ii-Marked) For Cable Laid Underground With Necessary Material And At Required Depth Upto 90Cm. Below Road/Ground Surface, Excluding Excavation, Back Filling With Excavated Material, Ramming And Making Thesurface Good. 50.00Mm Outside Dia.

BOQ

Sl. No. Item TitleItem Description
1Point wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multistrand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FR-LSH insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for : Light point/fan points : Primary short pointPoint wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multistrand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FR-LSH insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for : Light point/fan points : Primary short point
2same board : Same board switch & socket 16 Amp./S.S. combined 20/16/6 Ampsame board : Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp
3Sub-mains in surface rigid PVC conduit (MMS) :Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc,as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.8 - As per Amendment - 20.03.2024) . 3 Wire , 3 Wire sub main, 4.0 sq. mm. cableSub-mains in surface rigid PVC conduit (MMS) :Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc,as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.8 - As per Amendment - 20.03.2024) . 3 Wire , 3 Wire sub main, 4.0 sq. mm. cable
4MCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Double Pole : MCB DP 6Amp to 32Amp 10kA ratingMCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Double Pole : MCB DP 6Amp to 32Amp 10kA rating
5MCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures , Triple Pole, MCB TP 6Amp to 32Amp 10kA ratingMCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures , Triple Pole, MCB TP 6Amp to 32Amp 10kA rating
6MCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures : MCB SP 6Amp to 32Amp 10kA ratingMCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures : MCB SP 6Amp to 32Amp 10kA rating
7Fixing of MCB/MCCB/Isolator, (labour only) : Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required asper accepted practice, including mounting onbusbar and cable connection etc. complete (labour only): MCB/Isolator SP/DPFixing of MCB/MCCB/Isolator, (labour only) : Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required asper accepted practice, including mounting onbusbar and cable connection etc. complete (labour only): MCB/Isolator SP/DP
8Fixing of MCB/MCCB/Isolator, (labour only) : Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required asper accepted practice, including mounting onbusbar and cable connection etc. complete (labour only) : MCB/MCCB Isolator TP/TPN/FPFixing of MCB/MCCB/Isolator, (labour only) : Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required asper accepted practice, including mounting onbusbar and cable connection etc. complete (labour only) : MCB/MCCB Isolator TP/TPN/FP
9SPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 4 Way double door IP 43 protectionSPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 4 Way double door IP 43 protection
10SPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 6 Way double door IP 43 protectionSPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 6 Way double door IP 43 protection
11SPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 8 Way double door IP 43 protectionSPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 8 Way double door IP 43 protection
12SPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 12 Way double door IP 43 protectionSPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 12 Way double door IP 43 protection
13SPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 16 Way double door IP 43 protectionSPN MCB DB : Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 16 Way double door IP 43 protection
14Labour charges: Labour charges for fixing sheet steel enclosure,MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete. For item no : 27.11.1 to.27.11.4Labour charges: Labour charges for fixing sheet steel enclosure,MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete. For item no : 27.11.1 to.27.11.4
15Labour charges: Labour charges for fixing sheet steel enclosure,MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete. For item SOR no : 27.11.5 & 27.12.1 to 27.12.2Labour charges: Labour charges for fixing sheet steel enclosure,MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete. For item SOR no : 27.11.5 & 27.12.1 to 27.12.2
16Labour charges: Labour charges fo rfixing sheet steel enclosures,MCB DB surface mounting type, as per accepted practice on 25x25x5 mm angle iron clamp, including supplying and fixing of clamp duly embedded in wall, cable connection etc. complete : For item sor no 27.11.6 & 27.11.7; 27.12.5 ; 27.13.2 to 27.13.4 & 27.14.1 to 27.14.4 ; 27.15.1 to 27.15.4Labour charges: Labour charges fo rfixing sheet steel enclosures,MCB DB surface mounting type, as per accepted practice on 25x25x5 mm angle iron clamp, including supplying and fixing of clamp duly embedded in wall, cable connection etc. complete : For item sor no 27.11.6 & 27.11.7; 27.12.5 ; 27.13.2 to 27.13.4 & 27.14.1 to 27.14.4 ; 27.15.1 to 27.15.4
17LED tube rod fixture : Supply and fixing Led tube rod comprising of LED tube with non integral / integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L70, system lumen output should be minimum with system efficacy >100lm/Watt. LEDdriver PF>0.95 & THD<20%.The colour rendering index of LED light should be more than 70. Submission LM79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 18W Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser.LED tube rod fixture : Supply and fixing Led tube rod comprising of LED tube with non integral / integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L70, system lumen output should be minimum with system efficacy >100lm/Watt. LEDdriver PF>0.95 & THD<20%.The colour rendering index of LED light should be more than 70. Submission LM79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 18W Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser.
18Modular PVC box (surface) : Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 4 Module PVC boxModular PVC box (surface) : Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 4 Module PVC box
19XLPE insulated power cable, al. conductor : Supply of XLPE insulated power cable(conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor , 3½ core armoured : 25 sq. mmXLPE insulated power cable, al. conductor : Supply of XLPE insulated power cable(conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor , 3½ core armoured : 25 sq. mm
20Cable Laying : 1.1KV grade of size not exceeding 25 sq. mm : Laying of one number rmoured / unarmoured power cable1.1KV grade of size not exceeding 25 sq.mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required.Cable Laying : 1.1KV grade of size not exceeding 25 sq. mm : Laying of one number rmoured / unarmoured power cable1.1KV grade of size not exceeding 25 sq.mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required.
21Double wall corrugated pipes (DWC) of HDPE : Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II-marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, excluding excavation, back filling with excavated material, ramming and making thesurface good. 50.00mm outside dia.Double wall corrugated pipes (DWC) of HDPE : Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II-marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, excluding excavation, back filling with excavated material, ramming and making thesurface good. 50.00mm outside dia.

AI Tender Summary

OUR REF NO 58253279
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 19.10 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name National Hydroelectric Development Corporation
Work Description Bids Are invited for Custom Bid For Services - Electrical Wiring Of Residential And Non-Residential Parking Garage Of Urja Vihar Colony Of Omkareshwar Power Station - Point Wiring Surface Rigid P.V.C. Conduit: Point Wiring (Excluding Metallic Switch Box & Sheet But Including Switches, Sockets, Lamp Holders/Ceiling Roses Etc) With 1.5Sq. Mm. Pvc Insulated Cable Fr-Lsh With Copper Multistrand Conductor Isi Marked In Surface Rigid P.V.C. Conduit (Mms) Isi Marked Of Suitable Size And 1.5Sq. Mm. Pvc Fr-Lsh Insulated Copper Earth Continuity Conductor Of Green Colour Inside Conduit Etc. As Required As Per Specification For : Light Point/Fan Points : Primary Short Point , Same Board : Same Board Switch & Socket 16 ./S.S. Combined 20/16/6 , Sub-Mains In Surface Rigid Pvc Conduit (Mms) :Wiring For Sub-Mains With Pvc Insulated Cable Frls With Copper Multi Strand Conductor Isi Marked In Surface Rigid Pvc Conduit (Mms) Isi Marked Of Suitable Size (Conduit Included) Including 2Mm Thick Accessories, Connection Etc,As Required As Per Specification. (Refer General Notes For Classification Of Conduit Wiring Point No.8 - As Per Amendment - 20.03.2024) . 3 Wire , 3 Wire Sub Main, 4.0 Sq. Mm. Cable , Mcb C Series, 240/415V, 50 Cycle, 10Ka/15Ka : Supply Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker (Mcb) Of C Series With Short Circuit Indication, Suitable For 240/415 Volts,50 Cycle, 10 Ka/15 Ka Value Ac Supply Conforming To Is : 8828 : 1996, Iec : 60898 :2002 & 60947-2 But Without Enclosures :- Double Pole : Mcb Dp 6 To 32 10Ka Rating , Mcb C Series, 240/415V, 50 Cycle, 10Ka/15Ka : Supply Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker (Mcb) Of C Series With Short Circuit Indication, Suitable For 240/415 Volts,50 Cycle, 10 Ka/15 Ka Value Ac Supply Conforming To Is : 8828 : 1996, Iec : 60898 :2002 & 60947-2 But Without Enclosures , Triple Pole, Mcb Tp 6 To 32 10Ka Rating , Mcb C Series, 240/415V, 50 Cycle, 10Ka/15Ka : Supply Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker (Mcb) Of C Series With Short Circuit Indication, Suitable For 240/415 Volts,50 Cycle, 10 Ka/15 Ka Value Ac Supply Conforming To Is : 8828 : 1996, Iec : 60898 :2002 & 60947-2 But Without Enclosures : Mcb Sp 6 To 32 10Ka Rating , Fixing Of Mcb/Mccb/Isolator, (Labour Only) : Fixing Of Mcb/Mccb/Isolator In Sheet Steel Enclosure As Required Asper Accepted Practice, Including Mounting Onbusbar And Cable Connection Etc. Complete (Labour Only): Mcb/Isolator Sp/Dp , Fixing Of Mcb/Mccb/Isolator, (Labour Only) : Fixing Of Mcb/Mccb/Isolator In Sheet Steel Enclosure As Required Asper Accepted Practice, Including Mounting Onbusbar And Cable Connection Etc. Complete (Labour Only) : Mcb/Mccb Isolator Tp/Tpn/Fp , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 4 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 6 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 8 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 12 Way Double Door Ip 43 Protection , Spn Mcb Db : Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar, Neutral Bar, Earth Bar, Connection Copper Wire Not Less Than 16 Sq.Mm & Two Earth Terminals Etc. Complete As Per Is:13032(Exclusive Of Mcb & Isolator)- 16 Way Double Door Ip 43 Protection , Labour Charges: Labour Charges For Fixing Sheet Steel Enclosure,Mcb Db Surface Mounting Type, As Per Accepted Practice On 25X5mm Flat Iron Clamp Duly Embedded In Wall, Cable Connection Etc. Complete. For Item No : 27.11.1 To.27.11.4 , Labour Charges: Labour Charges For Fixing Sheet Steel Enclosure,Mcb Db Surface Mounting Type, As Per Accepted Practice On 25X5mm Flat Iron Clamp Duly Embedded In Wall, Cable Connection Etc. Complete. For Item Sor No : 27.11.5 & 27.12.1 To 27.12.2 , Labour Charges: Labour Charges Fo Rfixing Sheet Steel Enclosures,Mcb Db Surface Mounting Type, As Per Accepted Practice On 25X25x5 Mm Angle Iron Clamp, Including Supplying And Fixing Of Clamp Duly Embedded In Wall, Cable Connection Etc. Complete : For Item Sor No 27.11.6 & 27.11.7; 27.12.5 ; 27.13.2 To 27.13.4 & 27.14.1 To 27.14.4 ; 27.15.1 To 27.15.4 , Led Tube Rod Fixture : Supply And Fixing Led Tube Rod Comprising Of Led Tube With Non Integral / Integral Driver, Upto 6500K Color Temp Having 40000 Burning Hrs Life With Minimum @ L70, System Lumen Output Should Be Minimum With System Efficacy >100Lm/Watt. Leddriver Pf>0.95 & Thd<20%.The Colour Rendering Index Of Led Light Should Be More Than 70. Submission Lm79-08/Is16106 (2012), Iec60598, Iec61347 I/C Connection Wire, Testing Etc. To Complete The Job. Tube Light Led 1 X 18W Tube Light Led 1 X 18Watt, Integral I/C Batten Aluminium Body, Pc Diffuser. , Modular Pvc Box (Surface) : Supplying And Fixing Of Approved Make Modular Type Pvc Box Minimum Depth 40Mm And Minimum Thickness 2Mm With Modular Base And Cover Plate Including Fixing On Surface Etc. As Required For:- 4 Module Pvc Box , Xlpe Insulated Power Cable, Al. Conductor : Supply Of Xlpe Insulated Power Cable(Conforming Is-7098 Part-I) 1100 Volt Grade, 1 Core/2 Core/3½ Core/4 Core Isi Marked With Alu. Stranded /Solid Conductor , 3½ Core Armoured : 25 Sq. Mm , Cable Laying : 1.1Kv Grade Of Size Not Exceeding 25 Sq. Mm : Laying Of One Number Rmoured / Unarmoured Power Cable1.1Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In All Soil/ Murrum /Soft Rock, Sand Cushioning, Protective Covering And Refilling The Pit Etc. As Required. , Double Wall Corrugated Pipes (Dwc) Of Hdpe : Supplying And Installing Double Wall Corrugated Pipes (Dwc) Of Hdpe (Is 14930 Part Ii-Marked) For Cable Laid Underground With Necessary Material And At Required Depth Upto 90Cm. Below Road/Ground Surface, Excluding Excavation, Back Filling With Excavated Material, Ramming And Making Thesurface Good. 50.00Mm Outside Dia.
Basic Detail
Tender No GEM/2026/B/8082225
Bidding Type Tender
Location
City East Nimar
State Madhya Pradesh
Key Dates
Publish Date 28 Oct 2026
Submission Date 18 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 19.10 Lakhs
Tender Fee Ref. Documents
EMD 38000
Exemption Available
Document List
26ec59f7-b699-4d80-a766-42e248b3bd3d.pdf
1791632012.xlsx
1792588513.pdf
1790399213.pdf
1792588517.pdf
1790399416.pdf
1790399468.pdf
1792588504.pdf
1793191455.pdf
1792588563.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

26ec59f7-b699-4d80-a766-42e248b3bd3d.pdf

xlsx

1791632012.xlsx

pdf

1792588513.pdf

pdf

1790399213.pdf

pdf

1792588517.pdf

pdf

1790399416.pdf

pdf

1790399468.pdf

pdf

1792588504.pdf

pdf

1793191455.pdf

pdf

1792588563.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender