Tender For Certain Repair To Roof Leakage, Cgi/Pgi/Sheet/False Ceiling Including Connected Item Of Work At Omq/Smq At Af Stn Udh Ur
Tender Value
44.99 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
19 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain Repair To Roof Leakage, Cgi/Pgi/Sheet/False Ceiling Including Connected Item Of Work At Omq/Smq At Af Stn Udh Ur
BOQ
| Sl. No. | Item Description |
| 1 | M&L for complete waterproofing treatment to roof surface/parapet/ terrace using Asian Paints smartcare system (Hydroloc xtreme/ Damp Proof Ultra or approved equivalent)/ Dr. Fixit (roofseal classic/roofseal select)/ Berger consisting of the following operations: (a) Preparation of roof surface including removal of existing bitumen coating, APP membrane, PCC padding & mud fuska of any thickness etc completely, laitance, dust, grease, algae/fungus by using intense wire brushing or high speed water jet for thorough cleaning. (b) Filling of visible cracks/opening with smartcare crack seal. Bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortar. (c) Applying primer coat (Smartcare epoxy primer/damp proof primer) @ 0.92 Sqm/ltr using roller. (d) Applying two or more coats of smartcare waterproofing system (Damp proof ultra/hydroloc xtreme) with reinforcement mesh at roof surfces/corners/junctions, achieving minimum total dry film thickness 1.5mm. Note:- Rate include for \\"Taking down existing water tank from existing staging carefully and refixing the water tank in original position after waterproofing treatment including necessary fixing arrangement as required\\". (Work will be carried out upto height of 15M). |
| 2 | Demolition of cement concrete (unreinforced) of any descriptions, Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 3 | M&L for Removing demolished material exc. 1.5km but n exc.5.0km and depositing where directed complete all as specified. |
| 4 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. notless than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed. |
| 5 | Supply only bitumen primer for use in waterproofing and damp-proofing treatments complete all as specified and as directed. |
| 6 | M&L for applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified directed complete all as specified. |
| 7 | M&L for providing 25mm thick cement concrete in roof as base Type B-0, 1:2:4 using 12.5mm graded aggregate laid in slope rounded and chamfered on edges with water proofing compound and curing for 07 days by ponding of water over roof complete all as specified and as directed by Engr-in-Charge. |
| 8 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixingor removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified. |
| 9 | S&F 110mm bore PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified. |
| 10 | S&F 110mm bore PVC(SWR) bends any radius, complete all as specified. |
| 11 | Disconnecting existing water tanks exc 250 & n.exc 500 Ltr capacity, setting aside (or lowering if required ) and cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes and reconnecting and re-fixing in position, complete all as specified and directed. |
| 12 | Disconnecting existing water tanks exc 500 & n.exc 1000 Ltr capacity, setting aside (or lowering if required ) and cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes and reconnecting and re-fixing in position, complete all as specified and directed. |
| 13 | Dismantling and removing to water storage tanks of capacity exc 250 & not exceeding 500 liters and removing to stores complete all as specified . |
| 14 | S&F rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 500 liters including all accessories, complete all as specified. |
| 15 | Dismantling and removing to water storage tanks of capacity exceeding 500 liters but not exceeding 1000 ltrs and removing to stores complete all as specified . |
| 16 | S&F rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 liters including all accessories, complete all as specified. |
| 17 | S&F in repairs 20 mm bore dia of pipe ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (min weight 20 mm - 210 grms). |
| 18 | Dismantling plain or corrugated steel sheets, asbestos cement (corrugated, semi corrugated) etc sheets and any type or any description of roof covering, complete all as specified. Note: Work will be carried out up to a height of 20 m from GL. |
| 19 | M&L for pre painted galvalume aluminium zinc coating GI based corrugated sheets 0.5 mm thick of any colour having tensile strenght of 550/MPA as in roof covering, cladding to wall fixed with self taping screws complete all as specified. |
| 20 | All as per Srl item No 19 above but plain sheets as in ridges / valley gutter. |
| 21 | Demolition of brick work or stone masonry built in cement mortar including all quoines arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified. |
| 22 | M&L for brick work with sub class 'B' bricks 6mm mean radius straight or curved on plan to any radius built in cement mortar 1:6 complete all as specified. |
| 23 | Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key scrubbing down with water etc. complete all as specified. Note: Work will be carried out up to a height of 20 m from GL. |
| 24 | M&L for 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement with water proofing compound all as specified and directed. Note: Work will be carried out up to a height of 20 m from GL. (Water proofing compound to be paid separately) |
| 25 | Supply only integral water proofing compound complete all as specified. |
| 26 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces (cleaning and preparation of old surface by wire brush) complete all as specified and as directed by Engr-in-Charge. |
| 27 | M&L for cleaning of any type of roof surfaces by removing dirt, dust, loose particles, algae, fungus, moss, roots, vegetation growth, bird droppings and any foreign material completely. The work shall include scrapping, wire brushing, sweeping, washing with clean water, applying approved chemical solution (where directed) for treatment of fungus/algae, and disposal of all rubbish/muck outside the MoD land as directed by Engr-in-Charge. Note: Work will be carried out up to a height of 20 m from GL. |
| 28 | Demolition of cement concrete (unreinforced) as in ground floor & paving n exc 15cm thick below or above ground level complete all as specified and as directed. |
| 29 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry or laid dry and pointed in ant type of mortar complete all as specified and as directed by Engineer-in-Charge. |
| 30 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade withgrey cement and pigment complete all as specified and as directed |
| 31 | M&L for sand cushioning 50mm thick under floor or in foundation including watering and consolidation, complete all as specified and as directed. |
| 32 | M&L for PCC 1:4:8 type D-2 75 mm thick (using 40mm graded aggregate) as in sub base layer, complete all as specified and as directed. |
| 33 | M&L for Cement concrete type B-1, 1:2:4 (20 mm graded aggregate) 25mm thickness as in floor for laying tiles, complete all as specified and as directed. |
| 34 | M&L for coloured Chequered cement concrete tiles of size 20cm x 20cm x 25 mm/30mmx30mmx25mm thick (with grey cement and colour pigments) set, jointed and pointed in neat cement slurry in floor, laid over and incl 15mm thick cement screed base in CM 1:4, complete all as specified and as directed. |
| 35 | Providing and fixing 300 × 300 x 10 mm outdoor Endura tiles, of approve colour, shade, design and texture, suitable for external pathway flooring, having high strength, low water absorption, abrasion resistance and weather resistance, with anti-skid/rough surface finish, laid over prepared cement mortar bed of 25mm thickness in proper line, level and slope, including cutting and fitting of tiles at edges and junctions, maintaining uniform joints, filling joints with approved cementitious grout/jointing compound, cleaning and washing the finished surface complete, all as directed by Engineer-in-Charge. |
| 36 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete all as specified and as directed |
| 37 | M&L for except stone walling of random rubble, uncoursed built in cement mortar (1:6) complete as specified and directed |
| 38 | M&L for Raised pointing to random or polygonal rubble, uncoursed or brought upto courses built in cement mortar (1:3) complete as specified and directed |
| 39 | M&L for dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as speified and directed. |
| 40 | Providing & fixing in repairs false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles with semi perforated 12 mm thick nicro tegular edged GRG false ceing tiles of size 595 x 595 mm of approved texture, designand patterns |
| 41 | Dismantling structural steel work including doors, gates of opening area n.exc 30.00 sqm each but excluding framed truss etc. complete all as specified and as directed. |
| 42 | S & F steel rolling shutters 1.25mm thk of laths gear operated type of opening area n.exc 30.00 sqm each with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and , erected in position as indicated complete |
| 43 | Providing and fixing 2/3 mm thick FRP (Fibreglass Reinforced Plastic) sheet for covering/protection of iron gates, sheds and other structural members, including cutting to required sizes and shapes, drilling, overlapping and fixing to the existing/new MS iron framework with suitable self-drilling screws/bolts, nuts, washers and necessary accessories, complete with all labour, scaffolding, tools and tackles, transportation, loading/unloading and all incidental works required to complete the job as directed by Engineer-in-Charge. |
| 44 | Supply and fixing of Aluminium Composite Panel (ACP) sheets of approved make, colour, shade and finish, of 3 mm overall thickness comprising aluminium skins on both sides with suitable polyethylene/mineral-filled core, including cutting, routing, grooving, bending, fabrication and fixing in position with approved aluminium/MS framework, brackets, cleats, screws, rivets and suitable weather-resistant sealant, including all necessary accessories, edge finishing, joint treatment, alignment, scaffolding, labour, tools and plants, transportation and all incidental charges, complete in all respects as directed by the Engineer-in-Charge. |
| 45 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 46 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 47 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 48 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground post embedded in cement concrete complete all as specified and as directed |
| 49 | Excavation in post holes( or similar holes) each n exc 0.5 cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in any type of soil,complete all as specified and as directed. |
| 50 | M&L for PCC 1:3:6 Type C-2 (using 40mm graded Agg) as in foundations, filling and mass concrete, complete all as specified and as directed. |
| 51 | Mild steel work for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. win |
| 52 | M&L for Mild steel round bars 10mm dia and over , cut to length, bent to shape reqd, including cranking, bending for tieing of chain link fencing of Gd.I, IS-432 (Part-I), complete all as specified and as directed. |
| 53 | S&F in repairs galvanised. 2 strand, steel Barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails , including, securing or tying at crossings with and provision of galvanised mild steel wir |
| 54 | M&L for Preparation of new steel iron surfaces of any descripotion over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed. |
| 55 | Preparation of existing CGI (Corrugated Galvanised Iron) roof sheets for painting by thoroughly cleaning the surface to remove dust, dirt, rust, loose paint, grease and other foreign matter, scraping and wire-brushing the affected areas, and applying suitable rust-inhibiting metal primer on exposed metal surfaces, followed by two coats of approved quality synthetic enamel paint suitable for galvanised iron sheets, as specified, to achieve a uniform and durable finish. The work shall include all materials, labour, scaffolding, ladders, safety arrangements, surface preparation and all incidental charges complete, as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
TodayNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender