Tender For Provision Of Drinking Water Facility To Atc Devatalagutta Of Dmrl Hyderabad
Tender Value
92 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
12 days left
EMD
1.63 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Drinking Water Facility To Atc Devatalagutta Of Dmrl Hyderabad
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Construction of UNDERGROUND SUMP 150 KL including all fittings and fixtures complete all as shown on drawings, as specified and as directed. |
| 3 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - II representing __________% ___________________ percent Above / Below the lump sum price of `6,12,121.89 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - III representing __________% ___________________ percent Above / Below the lump sum price of ₹44,71,699.60 inserted by the MES in Schedule ‘A’ Part - III |
| 5 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IV representing _____% ___________________ percent Above / Below the lump sum price of ₹3,200.00 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Schedule 'A' Part - VThis Schedule is not repriced by MES and the repriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 6.00 to 24.00. |
| 7 | SITE CLEARANCE AND DEVELOPMENTExcavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft / loose soil for foundation of poles, structures, stay rods, laying of underground cable etc; complete all as specified and directed. |
| 8 | Returning, filling in, including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick using soil complete all as specified and directed. |
| 9 | Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 10 | INTERNAL WATER SUPPLYProviding and carry out water proofing treatment to sound, moisture free concrete surface system includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100 plasticised expansive ground admixture supplies in 225 gm pouch, treatment of construction joints using polymer modified mortar prepare by using Nitobond SBR latest's, application of polymer modified batta |
| 11 | at floor, wall junction, filling of annular space around rain water outlet using conbextra GP2 non shrink cementinous grouts, Undulated surface and pot hole shall be treated with epoxy mortar or putty to obtained sound / levelled surface, application of primer Nito proof WB primer on sound mortar slab surface, followed by application of coat of Nito proof 600 PF liquid applied single component pitch free polyurethane coating supplied in 25 kg drum coverage @ 2.30 Kg/m2 to achieve 1.5mm thickness in two coats complete including all tools and tackles as per manufacturers specification, coating shall be having |
| 12 | crack bridging of 2mm, elongation (ASTMD 124) greater than 600 percentage, tensile strength (ASTM D412), 2.5 N/MM2, recovery from elongation (ASTM D412), 95 percentage, 85 percentage of solid contantents, tear resistance (ASTM D624), 15 KN/M, shore A hardness (ASTM D2240), 60 water vapour transmission not more than 1 gm / M2, water permeability (DIN -1048) - NIL, services temperature - 40'c to 70 degree's, flash point greater than 70'C HSE guidelines: It is recommended to provide adequate general and local exhaust ventilations, providing protection to |
| 13 | eye, face, hand and other skin by wearing appropriate gloves, google, face mask, respiratory protection etc. directed in SDS of the product complete all as specified and directed. |
| 14 | EXTERNAL WATER SUPPLYS&F, pump set of 7.5 HP three phase centrifugal pump set including necessary connections complete all as specified and directed. |
| 15 | S&F, cast iron foot valve of size 80mm dia, heavy duty including all necessary accessories required like rubber gasket, nuts, bolts etc; complete all as specified and directed. |
| 16 | S&F, 80mm dia cast iron sluice valve, non-raising type, ISI marked with CI wheel, drilled flanged ends, PN-1.6, heavy duty with stainless steel spindle and gunmetal working parts including flanged jointing on both ends, jointing material such as rubber/fiber board gasket, suitable size bolts, nuts and twin washers complete all as specified |
| 17 | Providing, installation, testing & commissioning of non-return valve 150mm dia sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc., as required complete all as specified and directed. |
| 18 | S&F, cast copper alloy stop valve, 50mm size screwed down, high pressure with butterfly handle screwed both end for iron pipe complete all as specified and directed. |
| 19 | S&F, cast copper alloy stop valve, 25mm size screwed down, high pressure with butterfly handle screwed both end for iron pipe complete all as specified and directed. |
| 20 | S&F, Ball brass valves, 20mm size high pressure with epoxy coated aluminium rod & high density polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 21 | S&F, mono block pump set of 1 HP capacity including electric connection complete all as specified and directed. |
| 22 | EXTERNAL ELECTRIFICATIONSupply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core 70 Sqmm laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc.,complete all as specified and directed. |
| 23 | All as per Sl item No. 18 above but of size 4 core 6 Sqmm complete all as specified and directed.Note for Sl item No. 18 & 19: Earthwork Excavation, sand cushioning and cable covers will be measured and paid separately. |
| 24 | M&L for earthing complete with galvanised steel, earth plate electrode 600 x 600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 metres below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron 25 x 4mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron / steel all as shown in electrical plate No 3 on Page 497 of MES Schedule 2009 Part-I connected to main switch board / main DBs / earthing test point including all necessary excavation |
| 25 | and earth work in hard / dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 c/c both ways and pit / chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. |
| 26 | Supply & fabrication of LT Panel Board CPRI approved cubical type made of 2mm thick sheet steel indoor type with IP 43 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6mm with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved aluminium bus bar of 200 Amps, 415V capacity for each phases and half neutral fixed on suitable insulator all housed in |
| 27 | suitable bus bar chamber and cable alley and provision and fixing of LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and pilot indication lamps connecting incoming and out going cables with suitable cable glands etc; with suitable PCC foundations complete testing and commissioning complete and consisting the following (Main Panel 1) |
| 28 | IncomingMCCB, 4P, 100 Amp 36 KA - 01 No (Incoming)OutgoingStar Delta Starter of 7.5 HP capacity pump set - 02 Nos.MCB, 4P, 32 Amps 36 KA - 02 Nos.MCB, 4P, 16 Amps 16 KA - 02 Nos. |
| 29 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 30 | Supply and spreading of manufactured sand in trenches / transformer yard / two pole structure yard for cable protection complete all as specified and directed.Note: Punned thickness only shall be measured for payment purpose. |
| 31 | S&F, 100mm dia GI pipe light grade fixed to walls / poles or laid in trenches, road crossing etc., for protection of underground cable / earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls / poles complete all as specified and directed. Please Enable Macros to View BoQ information Compatibility Report for BOQ_89100 corrected by me.xls Run on 5/17/2020 18:00 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when opening this workbook in an earlier version of Excel or if you save this workbook in an earlier file format. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 Excel 97-2003 One or more cells in this workbook contain data validation rules which refer to values on other worksheets. These data validation rules will not be saved. 4.0 Excel 97-2003 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Excel 97-2003 One or more objects in this workbook such as shapes, WordArt, or text boxes may allow text to overflow the object boundaries. Earlier versions of Excel do not recognize this option and will hide overflowing text. 6.0 Excel 97-2003 |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender