Tender For Electrical System Upgrade - Med Office
Tender Value
3.86 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
18 days left
EMD
7800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical System Upgrade - Med Office
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group A |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 4 | Group C |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 6 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 8 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 9 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 10 | 3 x 1.5 sq. mm |
| 11 | 3 x 2.5 sq. mm |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | 20 mm |
| 14 | 25 mm |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 5/6 A switch |
| 17 | 15/16 A switch |
| 18 | 3 pin 5/6 A socket outlet |
| 19 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 20 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 21 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 22 | 1 or 2 Module (75mmX75mm) |
| 23 | 3 Module (100mmX75mm) |
| 24 | 4 Module (125mmX75mm) |
| 25 | 6 Module (200mmX75mm) |
| 26 | 8 Module (125mmX125mm) |
| 27 | 12 Module (200mmX150mm) |
| 28 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 29 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 31 | 16 way, Double door |
| 32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 33 | Single pole |
| 34 | Double pole |
| 35 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 36 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 37 | Installation, testing and commissioning following sizes of exhaust fan in the existing opening including making good the damages, connections, etc. as required. |
| 38 | Upto 450 mm sweep |
| 39 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.make atomberg efficio or equivalent. |
| 40 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 41 | Supply of 200mm sweep 20W BLDC Exhaust fan including connection etc. as required. Make:Atomberg or Equivalent |
| 42 | Supplying and fixing of 15/16A modular socket, Three module including connection, etc., as required. on existing modular cover plate. Make:Legrand Myrius Equivalent |
| 43 | Supplying and fixing of 4Module pop up flush mounting in table including providing suitable 6/10A 3pin socket,6/10A switch and RJ 45 socket connection, etc., as required.Make:Legrand incara pop up -6548-03 popup 4M AL |
| 44 | Supplying and fixing of 3Module pop up flush mounting in table including providing suitable 6/10A 3pin socket,6/10A switch connection, etc., as required.Make:Legrand incara pop up -6548-48 popup 3M AL |
| 45 | Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 46 | Supply and fixing of 1x1or nearest size of 18 W recess mounting type (square type),, 1800 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLRNE-18-CDL(1X1)) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
| 47 | Supply and fixing of 1x1or nearest size of 18 W surface mounting type (square type),, 1800 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLSNE-18-FO-CDL(1X1)) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
| 48 | Supply and fixing of 18/20 watt 4 feet T8 LED tube with efficacy 100lm/W. (T8 LED-Crompton LGT8-20-865-2 or compatible) |
| 49 | Supply and fixing of box type tube fittings (Batten ), complete with side holders etc, as required.(Batten- Crompton ECO DIJB12LT8-20 1XT8 or compatible) |
| 50 | Supply and fixing of box type tube fittings (Batten ) compatible for fixing 2 T8 LED tube light, complete with side holders etc, as required.(Batten- IGP162LT8-16 2XT8 or compatible) |
| 51 | Supply and fixing of LED Bulk head Luminaires (Crompton TIS-303-10-57-SL-DP-NWH or equvalent) with Efficacy >120 lm/W, CCT>3400K (WW/CDL/T) ANSI, IP 65 Protected.Including necessory clamps, screws, fastners etc. as required. |
| 52 | Supply and fixing of 400 mm sweep 35W BLDC wall mount fan, 1500RPM, minimum 76 CCM air delivery Wall mount Fan with necessory arrangement (Atomberg Renesa Wall mount or equvalent ) |
| 53 | Supplying and fixing 40 A to 63 A rating, Double Pole 240 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 54 | Supplying and fixing 6-32A rating, four Pole 240 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 55 | Supplying and fixing DP/TP/FP Enclosure complete with connections, testing and commissioning etc. as required. |
| 56 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 57 | Removing lights and fixture with/with out rad/clamp from cealing/wall handing over to EMU store safely as required. |
| 58 | Removing cealing fan with rad, regulator from switch board, handing over to EMU store safely including stacking of fan leafs as required. |
| 59 | Removing of submain wiring including conduit, wires, clamps etc. as required and handing over to the store/yard. |
| 60 | Removing of switch board of any size including wires, switches(modular/piano type) switch board, clamps, GI/plastic box etc. as required and handing over to the store/yard. |
| 61 | Labelling of DB/Switch board with adhesive plastic coated printed labels (3 to 6 letters, maximum 25sq.cm. size) necessory arrangement for fixing on exixting DB/switch board etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender