Tender For 1). repair maintenance Electrical And Mechanical Services At Ncc Bhawan, Sector-19, Rohini, Delhi. 2). repair maintenance Of E&M Services At Nav Kiran, Halfway / Longstay Home, Sector-03, Rohini, Delhi. (Sh: annual maintenance contract Of
Tender Overview
Project Description
Tender for 1). repair maintenance Electrical And Mechanical Services At Ncc Bhawan, Sector-19, Rohini, Delhi. 2). repair maintenance Of E&M Services At Nav Kiran, Halfway / Longstay Home, Sector-03, Rohini, Delhi. (Sh: annual maintenance contract Of Kirloskar Make Dg Set & Fire Fighting Diesel Engine Pump And Top Overhauling Of Dg Set And Diesel Engine Pump).
BOQ
| Sl. No. | Item Description |
| 1 | NCC Bhawan Building, Sector-19, RohiniAnnual comprehensive maintenance of Kirloskar make Diesel engine pump model no. 4R1040 T installed at NCC Bhawan Rohini including routine servicing, cleaning, checking, attending to minor/ major repairs & carrying out schedule maintenance at every 6 months. |
| 2 | Carrying out of 'B' check spares in Diesel Engine Pump including replacement of following parts testing and commissioning etc, credit back of old dismantled material (if any) complete as required, (Labour included in AMC scope). a) Fuel Filter Kit 1.1 ltr |
| 3 | b) Spinon Lube Oil Filter |
| 4 | c) Koel Care Premium genuine Oil 20- Ltr Can |
| 5 | d) Koel Care Genuine Coolant Premix 05- Ltr Can |
| 6 | e) Primary filter element |
| 7 | f) Hose Radiator to Water pump Pipe |
| 8 | g) Hose Water Pipe |
| 9 | h) Worm Drive hose clip 55 mm |
| 10 | i) Hose t-bolt clamp |
| 11 | j) Hose pipe to water |
| 12 | k) Thermostat by pass hose |
| 13 | l) Battery charger 10 amp 12 VDC |
| 14 | Carrying out one time repairing and top overhauling as per manufacturer's recommendation including replacement of following OEM spares for maintaining working and healthiness of 72 HP Kirloskar make Fire Engine credit back of old dismantled material (if any):a) Cylinder head gasket 6H.007.06.0.00b) Set of joints - 6R1080TA 6H.061.20.0.SPc) Valve Guide 6H.061.20.0.SPd) Valve Seat Insert (Inlet) 4H.007.02.0.00e) Valve Seat Insert (Inlet) 4H.007.03.0.00f) Valve Seat Insert (Exhaust) 4H.007.04.0.00g) Valve Collet 02.022.12.0.00h) Cylinder head bolt 4H.00.07.0.00i) Set of O Ring 6H.061.30.0.00j) Set of Copper Washer 6H.061.10.0.00k) Bush for injector 02.035.08.0.00l) Lube oil drain pipe: K26 Turbo 6H.034.11.0.00m) Ruvver Hose: Compressor Outlet - K24 Turbo 4H.168.03.0.00n) Hose (Radiator To water Pump pipe) 4H.073.01.0.00o) Hose (Pipe to Water Pump) 4H.073.02.0.00p) Hose Water pipe 6H.019.12.0.00q) WP assembly with Delvolute 4H.052.20.0.00r) Poly V Belt 4H.1493.01.0.00s) Poly V Belt 6H.1171.01.0.00t) Leak off pipe sub assly 6H.023.10.0.00u) LO Supply Hose (FIP) 4H.006.01.0.00v) Vent Pipe for Radiator 6H.056.03.0.00w) K Sealent (80 ML) 82.060.10.0.80x) Worm Drive Hose Clip (45 MM) 50.907.08.000y) By pass hose 4H.023.03.0.00z) Worm Drive Hose Clip 50.907.02.000aa) Rocker cover joint metalic 4H.009.12.0.00ab) Valve Stem Seal 06.631.02.0.00ac) Cylinder Liner Assembly 2H.008.10.0.00ad) Piston ring set 2H.009.30.0.00ae) bearing bush S/E: 6K1080TASTD 553.5.00.703af) Con Rod Bearing: 61080 STD B.006.4.00.003ag) Injector Calibration Repairah) FIP calibration / repairsai) Crank case machining / repairsaj) Egine top overhaul chargesak) Radiator Repair and cleaning charges at site |
| 15 | Annual comprehensive maintenance of Kirloskar make 250 KVA DG Set installed at NCC Bhawan Rohini including routine servicing, cleaning, checking, attending to minor/ major repairs & carrying out schedule maintenance at every 6 months. |
| 16 | Carrying out of 'B' check spares in DG Set including replacement of following parts testing and commissioning etc credit back of old dismantled material (if any) complete as required (Labour included in AMC scope). a) Air Filter Primary |
| 17 | b) Air Filter Safety |
| 18 | c) Fuel Filter Kit 1.1 ltr |
| 19 | d) Spin on Lube Oil Filter - |
| 20 | e) Koel Care Premium genuine Oil 20- Ltr Can - 2 Nos. |
| 21 | f) Koel Care Genuine Oil 5 Ltr Can |
| 22 | g) Koel care genuine coolant premix 5 litre can |
| 23 | h) 150 AH Kirloskar Green Battery |
| 24 | i) Battery charger 10 amp 24 VDC |
| 25 | j) Battery water 5 ltr can |
| 26 | k) Radiator Descaling charger at site |
| 27 | Carrying out one time repairing and top overhauling as per manufacturer's recommendation including replacement of following OEM spares for maintaining working and healthiness of 250 KVA Kirloskar make DG Set credit back of old dismantled material (if any):a) Piston Assembly F6.4015.30.0.00b) Cylinder Liner Assembly F6.382.10.0.00c) Con Road Bearing SL90 M.055.4.00.003d) Teflon Oil Seal Few F6.016.16.0.00e) Set of Copper Washer F6.566.30.0.00f) Set of O Ring F6.566.80.0.00g) Small End Bush S.055.5.20.703h) Valve seat Insert: Inlet F6.4004.03.9.00i) Valve Seat Insert: Exhaust F6.4004.04.9.00j) Valve Guilde Finish F6.4004.02.0.00k) Valve Stem Seal 06.631.02.0.00l) Valve Pair F6.4004.100.0.00m) Valve Collet-3-Groove 02.022.28.0.00n) Valve Bridge F6.4004.08.0.00o) Joint (for Rocker Cover) F6.4006.13.0.00p) Rocket Support Assembly F6.4005.70.0.00q) Expansion Bellow: 4\\" F6.618.01.0.00r) Joint SS F6.618.02.0.00s) High Pressure Pipe Assembly F6.4013.100.0.00t) Fuel Return Pipe F6.801.28.0.00u) Fuel Pipe Pre filter to Feed Pump F6.4012.11.0.00v) Fuel pipe pre filter to tank F6.801.23.0.00w) Lube Oil Pump supply pipe to fuel pump F6.4012.14.0.00x) Leak off Pipe F6.4012.22.0.00y) Fuel Pipe Feed pump to fuel filter F6.4012.12.0.00z) Poly V Belt 8PK 1065 F6.184.03.0.00aa) Poly V Belt 4PK 1515 F6.184.04.0.00ab) Thermostat Element 39.040.09.0.00ac) Water Pump Sub Assembly F6.164.20.0.00ad) Joint for water pump F6.024.85.0.00ae) Joint Between thermostat cover & gear casing F6.156.44.0.00af) Radiator Drain Pipe: 82.5 KVA 3H.153.09.0.00ag) CAC Hose (Hot Side 4 Plies) 4H.1712.32.0.00ah) Hose T-Bolt Clamp 4H.1712.24.0.00ai) Hose Water Out F6.150.13.0.00aj) Hose for Thermostat to water tank F6.255.32.0.00ak) CAC Hose Cold side F6.377.39.0.00al) Hose from radiator to water pump F6.801.11.0.00am) Vent Pipe F6.801.26.0.00an) VDO sensor assembly 4H.890.40.0.00ao) Float Level sensor 105 LEN DV0.901.29.0.00ap) Magnetic pick up 16x1.5 thread F6.741.16.0.00aq) Air cleaner safety element F6.404.28.0.00ar) Air cleaner primary element F6.404.27.0.00as) Fuel Fliter kit 1.1 Ltr 48.999.20.0.00at) Spin on Lube Oil Filter 06.436.01.0.00au) Cylinder Head gasket F6.007.98.0.00av) Joint for inlet manifold F6.4008.02.0.00aw) Copper Washer (14x20) 50.508.12.000ax) Copper Washer (6x10) 50.508.04.000ay) Cylinder head repair charges 99.CHR.01.00az) Turbo charger checking and repair 99.TCR.01.0.00ba) FIP calibration / repairs 99.FIP.01.00bb) Radiator Repair and cleaning charges 99.RAD.01.00bc) Injector Calibration / Repair 99.INJ.01.00bd) Engine Top Overhaul 99.TOH.01.00 |
| 28 | Nav Kiran Building, Sec-3, RohiniAnnual comprehensive maintenance of Kirloskar make Diesel engine pump model no. 4R1040 T installed at FSL building, Rohini including routine servicing, cleaning, checking, attending to minor/ major repairs & carrying out schedule maintenance at every 6 months. |
| 29 | Carrying out of 'B' check spares in Diesel Engine Pump including replacement of following parts testing and commissioning etc credit back of old dismantled material (if any) complete as required, (Labour included in AMC scope) a) Fuel Filter Kit 1.1 LTR |
| 30 | b) Spinon Lube Oil Filter |
| 31 | c) Koel Care Premium Genuine Oil 20 LTR Can |
| 32 | d) Koel Care Genuine Coolant Premix 5 LTR Can |
| 33 | e) Primary filter element |
| 34 | f) Hose Radiator to Water pump Pipe |
| 35 | g) Hose Water Pipe |
| 36 | h) Worm Drive hose clip 55 mm |
| 37 | i) Hose t-bolt clamp |
| 38 | j) Hose pipe to water |
| 39 | k) Thermostat by pass hose |
| 40 | l) Battery charger 10 amp 12 VDC |
| 41 | m) Silencer |
| 42 | n) Silencer Fitment Charges Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender