Health and Family Welfare Government Departments Closing in 6 days TDR #58249817

Tender For Repair & Renovation Work For Setting Up Of Su Swasthya Kendra At Bajitpur Sc, Suti-Ii Block, Murshidabad.

Issued by Government Departments · Murshidabad, West Bengal
Tender Value
11.46 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
6 days left
EMD
22921
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Murshidabad → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair & Renovation Work For Setting Up Of Su Swasthya Kendra At Bajitpur Sc, Suti-Ii Block, Murshidabad.

BOQ

Name of Work:- Repair & Renovation work for setting up of Su swasthya Kendra at Bajitpur SC, Suti-II Block, Murshidabad.
Sl. No. Item Description
1Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including remo ving, spreading or stacking the spoils within a lead of 75 m. as directed.(a) Depth of excavation not exceeding 1,500 mm.
2Earth work in filling in foundation tren ches or plinth with good earth, in lay ers not exceeding 150 mm. include ing watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation.
3Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.Found,Toilet
4I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)(A) [Pakur Variety](a) 1:3:6 proportion
5A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed with water, ramming complete including the cost of supply of sand.
6Repairing crack in wall by cement grout ing (1 : 2) including widening the crack on the surface (into V section) cleaning and packing the same with cement mortar (1 : 2) and finishing off to match with adjacent surface.(Cement-69 Kg/100 m)At Gr. Fl.
7(A) Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including mending good damages and finishing the surface to match with adjacent areas complete as per direction.(i) With plain cement concrete blocks(1:1½:3) with stone ,chips.(a) Block size 250 x 125 x 75 mm., In GR.Fl
8Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.A) Ceiling Gr.Fl,Store.WC,Passage,EX Room,B) In side Wall, Gr.Fl,Store.WC EX. Room,Less D3,O. Room,C) Out Side Wall, Gr.Fl,EW,Back,Total Gr. Fl............. ( A+B+C)
9D) Ceiling 1ST .Fl,Store.WC,Passage,D) In side Wall, O. RoomStore. 1ST.Fl,WC,EX. Room,Deduction,D3,W3,E) Out wall- 1ST .Fl,Total Gr. Fl............. ( D+E+F)
10Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a) In Gr. floor ,G.F, Store,Passage,D2,WC ,Door Seal,EX Room,Office,E.Room, Door Seal,
11In 1st Floor,G.F, Store,Passage,D3,WC ,Lab,Door Seal,EX Room,Office,E.Room, Door Seal,
12Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directed within a lead of 75 m.In Ground Floor , Store wall,Exhaust,V1,For pipe line,Groove
13In 1st Floor,Add D2
14Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.(a) upto 150 mm. thick,In ground floor including roof.
15In 1st floor including roof.
16Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.,a) Pakur Variety, Gr.Fl (06 km)
17At 1st. Fl.
18Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In Gr.Fl,(i) Pakur Variety, 06 Km,Tie beam,Lintel beam,Top sink,Blood Collection,Sitting Slab,Chajja
19In 1st Floor,Lintel beam,Top sink,Lab Lintel Beam,Sitting,Lab ,Slab,EX. Room,Chajja,Mumty Room
20Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing complete as per drawing and direction. Gr.Fl,i) Tor steel/Mild Steel,(jsw/jspl/shyam/Srmb/bmasl/electrosteel)ii) In first floor
21In 1st Floor
22Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straightincluding fitting, fixing and striking out after completion of works (upto roof of ground floor),(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge.,Tie beam,Lintel beam,Top sink,Blood Collection,Sitting Slab,Chajja
23In 1st Floor, beam,Lintel beam,Top sink,Lintel for Lab,Sitting Slab,Lintel for Ex.Room,Lab,Sides,Chajja,Mumty Room
24Brick work with 1st class bricks in cement mortar (1:6),(b) In superstructure, ground floor
25(b) In superstructure, 1st floor,Piller,Tank Piller,Lab,Less
26125 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor. EX. Room,Store.Less for D1,Sink,Sitting Slab
27In 1st Floor,Less D,Mumty Room,Less,Less for Vst
28Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfer ing corners as directed , Gr.Fl,(i) With 1:4 cement mortar,(b) 10 mm thick plaster,
29(i) With 1:6 cement mortar,(c) 15 mm thick plaster,Add store room ,Toilet V3
30(i) With 1:6 cement mortar,(c) 15 mm thick plaster, Outside
31In 1st Floor,(i) With 1:4 cement mortar,(b) 10 mm thick plaster,
32(i) With 1:6 cement mortar,(c) 20 mm thick plaster,EX. Room ,Less D,Store.Less D3
33(i) With 1:6 cement mortar,(c) 15 mm thick plaster, Lab,Less for W2,Add 1st fl. 125 mm wall
34Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directedwith topping made with ordinary or white cement (as necessary) ,In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).(ii) 25 mm. thick, In Gr.Fl
35Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, Gr floor(a) One Coat
36First Floor
37Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.A) Floor,With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at backside of tiles using cement @ 2.91 Kg/Sq.m&joint filling usingwhitecement slurry 0.20kg/Sq.m.(a) Area of each tile above 0.09 Sq.m,(i) Other thanColoured decorative ,In Gr. Fl,Less D,Less D3Wall,With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles joint filling using white cement slurry @ 0.20kg/Sq.m. Gr.Fl.(b) Area of each tile above 0.09 Sq.m,(ii) Coloured decorative ,Wall of Table top,Wall of Sitting Slab,Less D3,Less V3,In GroundFloor
38In 1st Floor,WC,LAB,Deduction, D2,D3,v2,Wall of Table top,Wall of Sitting Slab
39Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.A) Floor,With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at backside of tiles using cement @ 2.91 Kg/Sq.m&joint filling usingwhitecement slurry 0.20kg/Sq.m. Area of each tile upto 0.09 Sq.m,(i) Other thanColoured decorative ,In Gr. Fl,Less D,Less D3Wall,With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles joint filling using white cement slurry @ 0.20kg/Sq.m. Gr.Fl.(b) Area of each tile above 0.09 Sq.m,(ii) Coloured decorative ,Wall of Table top,Wall of Sitting Slab,Less D3,Less V3,In Ground Floora) Wall
40In 1st Floor
4118 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matchingthe stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]
42Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stoneproperly by brass /copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-chargeincluding cost of materials, labour, scaffolding, staging,curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]
43Supplying, fitting & fixing granite tiles 10mm to 12mm. thickin columns, wall, facia etc. with 15 thick [avg] cement mortar(1:2) including making suitable arrangements to hold thestones properly by brass / copper hooks including pointing incement mortar (1:2) (1 white cement : 2 marble dust) with,Lab,Sink,Less
44In 1st.Fl,Lab
45Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately),(a) Upto area 2.5 Sq.m In Gr.Fl D,D3
461st floor
47Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).
48(h) sal local, In Gr.Fl,(h) sal local In 1st.Fl
49Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.iii) 35mm thick shutters with19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,
50In 1st.Fl,(b) Sishu, Gamar, Champ,
51Styles and rails of wooden shut ters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor:(i) For 25mm. Thick shutter.(b) Sishu, Gamar,
52Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately),(b) 40mm X 6mm, 200mm Length
53Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI,(vi) 100mm. X 50mm. X 1.25mm.mark.
54i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(a) 200mm long
55A) Iron door ring of approved quality fitted and fixed with nut and washer complete.(ii) 75mm dia.
56Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.(iv) 300mm x 19mm dia. bolt.
57Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(iii) 100 mm grip x 12 mm dia rod.
58Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mmx 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical sectionby galvanised steel screws after inserting two number steel including cost of materials and labour, hire charges of tools and appliances, carriage ofall materials, taxes and ,all other incidental charges complete.
59Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm ,shall be tapered on both sides to form lock rail.
60Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz doorframe ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, anglescrews etc. including labour charges for fitting and fixing of aluminiumdoor with door spring,/aluminium hinges, glass / Panel board allcomplete as per architectural drawings and direction of Engineer-incharge.( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc)10-12 Micron thickness Annodizing film Natural white.
61Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.(C) Both side decorative lamination, (II) Interior Grade. 12mm
62Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge.
63Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (vii) 225mm long x 10mm dia. Bolt
64Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aconforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, 10-12 Micron thickness Annodizing filmNatural white,For 2-Track window :Gr. Fl.W,Stair ,1st. Fl.W,Lab ,. Fl.Stair, V
65(a) M.S.or W.I. Ornamental grill of approved design joints contin uously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg ./sq .mtr and up to 16 Kg./sq. mtr.In Gr.floor,Plain sheet @ 8 Kg/m2
66In 1st floor
67Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.i) 4mm thick clear glass.
68Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost of all labour and materials.In First.Fl
69Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm).In ground floor..
70(b) 25mm mesh, In 1st Fl
71Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (One coat)
72Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) :(Two coats)
73(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.On Timber surface, Gr.Fl +1st,D
74(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.win grill,Collap,Grill,Stair Stair Gate,
75(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :iv) Two coats (with any shade except white)On Plastered surface, Gr.Fl +1stOn Timber surface, Gr.Fl +1st
76Other metal Surface, Windows, Grills Etc.
77Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge),In Gr. Fl,Deduction,
781st floor
79Applying Exterior grade Acrylic primer of approved quality andbrand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish),a) One Coats, Gr. Fl
801st floor
81Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat),a) Normal Acrylic Emulsion
82In 1st floor (Two Coat)
83Labour for Chipping of concrete surface before taking up Plaster ing work.1ST Fl.
84(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification,1ST Fl.
85Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in
861.5 mm thick Net cement finish in wall, dado,
87Main signage of Vinyle Board with ACP Boarder 1800X1200 MM
88Taking out M.S. or W.I. Grills from wooden frame including cutting lugs from masonry wall and refitting the same and mending good damages after repairs. (Excluding the cost of necessary repair of damages) or doing any other necessary works.
89Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor.
90Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in anysoil through masonry concretestructures etc if necessary and mending good damages including joining with jointingmaterails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. (ii) 110 mm. Dia.
91c) Bend 87.5 degree. (ii) 110 mm. Dia.
92d) Shoe (ii) 110 mm. Dia.
93Sanitary Plumbing Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately. (b) For Exposed Work. PVC Pipes PVC Pipes.40 mm
9425 mm
95(b) For Concealed Work. PVC Pipes.20 mm
96(b) For Concealed Work. PVC Pipes.15 mm
97Supplying, fitting and fixing bib cock or stop cock. (a)i) chromium plated bib cock short body (equivalent to code no. 511 & model- tropical./ sumthing special of ESSCO or similar brand)
98(d)i) chromium plated angular stop cock with wall flange (equivalent to code no. 5053 & model- Florentine of Jaquar or similar brand)
99Supplying P.V.C water storage tank of approved quality with closed top with lid(black)-Multilayer. (c) 500 litre capacity
100Supplying fitting & fixing 10 ltr. PVC low down cistern conforming to I.S specification with PVC fittings complete C.I brackets including two coats of painting to bracket etc.
101Labour for punching hole in plastic water storage tank up to 50 mm dia.
102Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size
103(iv) Angle back wash basin 400 mm X 400 mm
104Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets.(i) 610 mm X 450 mm X 200 mm(a) Plain edge sink with overflow
105Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut,15 mm dia. i) 450mm long
106Suppling fitting & fixing approved brand 32mm dia p.v.c waste pipe with p.v.c coupling at one end fitted with necessary clamps.i)900mm long
107Suppling fitting & fixing 15 mm swan neck tap with left & right hand operating knob with aerator.
108Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.530 mm X 430 mm x 180 mm
109Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing).(i) 580 mm X 440 mm
110Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.(i) 450 mm X 300 mm
111Supply of UPVC pipes (B type )& fitting conforming to IS 13592-1992 .A) i) single socketed 3 mtr length --b)110 mm
112(ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. A) Above ground .(ii) 110 mm dia.
113A) Under ground.(ii) 110 mm dia.
114B) FITTINGS.Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992.viii) Double Y with Door.b) 110 mm
115xi) door bend ( T.S.) b) 110 mm
116xv) vent cowl -(b) 110mm
117xvi) pipe clip ---(b) 110 mm
118(ii) Plain Tee ---(b) 110 mm
119Suppling fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with 'P' trap
120Supplying fitting & fixing squating plate with integral flushing in white vitreous chinaware of approvedmake in cement concrete (6:3:1) with jhama chips complete. i)450mm X350mm
121Supplying fitting & fixing closet seat of approved make with lid & C.P hinges,rubber beffer & brush screw complete. (a) E.W.C. (ii) Plastic (hallow type) white
122Supplying fitting & fixing 32 mm. dia. flush pipe of approved make with necessary fixing materials & clam complete. i)Polythene flush pipe.
123(i) Supplying, fitting and fixing liquid soap container.c) (a) Cromium plated.
124Supplying fitting & fixing towel rail with two brackets.a)C.P over brush---i)25mm dia,450 mm long.
125Submersible Works Supplying and delivery at site Submersible Pump Set incl. S&F 1.5 H.P Control Panel (Model: SPC2)3 core 1.5 Sq.mm flat copper cable (3M length) having following specification:-No of stage -25,Head-110 mtr,Discharge-1.8m3/hr ,nrv-32 mm Make: CROMPTON GREAVES / Similar make. Model: , 1.5 H.P with Control Panel, Size of Tube well : 4\\" x 2\\".
126Finishing the end of following P.V.C armoured Cable by crimping method incl.supplying and fixing solderless socket (Dowels make), tapes , anticorrosive paste & jointing materials. a) 3 Core 4 sq.mm PVC/A cable
127Supplying and laying 1.1kv grade PVC/A cable as below including S&F of earth continuty as below after cutting floor/pavement/wall/and making holes incl. Embedding the cable at an average depth 75mm in floor/wall/ pavement etc. and mending good the damage to original finish incl. removing the rubbish. a) 2 Core 4 sq.mm PVC/A cable with 1x8 No.SWG G.I
128Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of PVC armoured cable as below: a) 2 Core 4 sq.mm PVC/A cable
129Finishing the end of following P.V.C armoured Cable by crimping method incl.supplying and fixing solderless socket (Dowels make) , tapes , anticorrosive paste & jointing materials. d) 2 Core 4 sq.mm PVC/A cable
130Supplying and fixing C.I water proof looping cable box having hinged top cover having 4mm thick with rubber gasket living railway type mechanical locking arrangement earthing terminal with lug etc of size 8\\"x6\\"x4\\" comprising 3 Nos 15amps Kit-Kat fuse unit and housing the same in pole muffing
131Supplying and laying 1.1kv grade PVC/A cable as below including S&F of earth continuty as below after cutting floor/pavement/wall/and making holes incl. Embedding the cable at an average depth 75mm in floor/wall/ pavement etc. and mending good the damage to original finish incl. removing the rubbish. a) 2 Core 4 sq.mm PVC/A cable with 1x8 No.SWG G.I
132Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (c) For depth upto 150 metre for 50 mm dia. Tube well with top enlargement of 100 mm dia. (i) 50 mm dia. boring etc.
133(ii) 100 mm dia. boring etc. top enlargement
134Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (i) 50 mm
135Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (i) 50 mm dia.
136Supply of G. I. pipes of TATA make including necessary sockets , (e) 50 mm dia. (ii) Medium quality
137Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (i) 50 mm dia.
138Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). i) 32 mm
139ii) 40 mm
140i) 50 mm
141ii) 100 mm
142Labour for fitting and fixing high density poly-ethylene pipes or P.V.C. pipes for above ground work including cost of jointing materials paints etc. fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, (iii) 32 mm dia.
143(v) 50 mm dia.
144(viii) 100 mm dia.
145Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). vii) 25mm Dia
146Supplying, fitting and fixing heavy type bell mouth reducing socket. (i) 50 mm X 100 mm
147Supply of galvanised iron socket with I.S.I. mark. (iv) 50 mm
148Supply of G.I. bend. (iv) 50 mm
149Supply of G.I. plain equal elbow of approved brand and make. (iv) 50 mm
150Supply of G.I. nipple standard 50 mm long. (iv) 50 mm
151Supply of G.I. union. (iv) 50 mm
152Supply of G.I. short piece of TATA make (Above 50mm & upto150 mm long) (iv) 40 mm
153Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants, and scaffolding as required.
154Labour for making arrange ment for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
155Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equip ments, paying all charges and fees, testing etc. complete in all respect , as per direction.
156Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surfacea) Average run 5 mtr
157Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finisha) Average run 5 mtr
158Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
159Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
160Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
161Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
162Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
163Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. ( C-3, Item No- 21,a )
164Supply & delivery of Sweep:- 48\\" (1200mm) AC ceiling fan, 50-70 Watts, Speed:->=350 RPM, Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA STRIKER PLUS or CROMPTON [Approved by EIC]a) 1200 mm sweep
165Supply & delivery of single 4ft LED tube light fitting incl. 4ft LED tube, 1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Mas LEDtube 1200mm) [Philips: TMC 501 P 1xT-LED 22W P3241] or equivalent of Havells, Crompton etc. [Approved by EIC]
166Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. ( C-2, Item No- 14,b )
167Supply 9W LED lamp to the lamp point. [PHILIPS make][NS]
168Fixing only lamp [11/C-2]
169Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [1(iv). / E-14]
1702 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [1(iii). / E-14]
1712 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [1(ii). / E-14]
1722 x 36/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [1(i). / E-14]
173Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2x56/0.3 (6 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [9(iii)/F-5]
1742x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [9(ii)/F-5]
1752 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [9(i)/F-5]
176Supplying and fixing Sheet steel Main Switches on flat iron frame on wall DP 32 A (Page No. D1 item No.1(a)) Make - HPL/Havells
177Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)DP 32 A (Page No. D1 item No.1(a)) Make - HPL/Havells
178Supplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc240V DP, 32A (Page No. D 1, item No. 2 (a)) Make - HPL/Havells
179Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 Way DB (Page No. D 9 item No.11)
180Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
18132 A DP MCB [Make - Legrand / Schneider] (Page No. D 6 item No.7) [UPS Incomer DB:1 & Outgoing DB:1] (in case of installation of UPS at First landing of staircase of 1st Floor: Incomer DB:2)
18232 A DP MCB [Make - Legrand / Schneider] (Page No. D 6 item No.7) [2+4 Way UPS DB Incomer]
18325 A DP MCB [Make - Legrand / Schneider] (Page No. D 6 item No.7) [Emergency DB Incomer]
1842+4 Way enclosure (607710) [Make - Legrand / Schneider] (Page No. D 9 item No.13) [UPS DB]
185Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe (Page No.G-1/2(a)) [For UPS]
186Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil (Page No.G-1/1(b))
187Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required (Page No.G-2/4(a))
188Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
189Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buriedinside wall/floor as required and making connection toequipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages (a). Solid GI wire : No. 10 SWG (Page No.G-2/5(a) (iv))
190Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CIhinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe (Page No.G-2/3(a))
191Add :- G.S.T @ 18%
192Add : Labour Welfare Cess @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58249817
AUTHORITY Government Departments
TENDER VALUE 11.46 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Health And Family Welfare Department
Work Description Tender for Repair & Renovation Work For Setting Up Of Su Swasthya Kendra At Bajitpur Sc, Suti-Ii Block, Murshidabad.
Basic Detail
Tender No CMOH/MSD/ENGG/10804
Bidding Type Tender
Location
City Murshidabad
State West Bengal
Key Dates
Publish Date 28 Oct 2026
Submission Date 04 Nov 2026
Open Date 06 Nov 2026
Finance
Tender Value 11.46 Lakhs
Tender Fee Ref. Documents
EMD 22921
Exemption Not Available
Document List
BOQ_5192569.xls
c74a91c7-fc55-486d-ad48-ffae58dec4e2.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5192569.xls

html

c74a91c7-fc55-486d-ad48-ffae58dec4e2.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender