Drinking Water Supply and Sanitation Government Departments Closing in 13 days TDR #58248487

Tender For Installation Of Of Chattrasal Uttarpara Major Rli Scheme ( Including Supply And Delivery Of All Related Materials , All-In-One Works On Turn Key Basis ) Under Ch Adanga (A-M) Sub Division Under Chinsurah (A-M) Division Under Core Sector 20

Issued by Government Departments · Hooghly, West Bengal
Tender Value
73.11 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
13 days left
EMD
1.46 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Installation Of Of Chattrasal Uttarpara Major Rli Scheme ( Including Supply And Delivery Of All Related Materials , All-In-One Works On Turn Key Basis ) Under Ch Adanga (A-M) Sub Division Under Chinsurah (A-M) Division Under Core Sector 2026-27 Programme In The District Of Hooghly

BOQ

Name of Work:- INSTALLATION OF OF CHATTRASAL UTTARPARA MAJOR RLI SCHEME ( INCLUDING SUPPLY AND DELIVERY OF ALL RELATED MATERIALS , ALL-IN-ONE WORKS ON TURN KEY BASIS ) UNDER CH ADANGA (A-M) SUB DIVISION UNDER CHINSURAH (A-M) DIVISION UNDER CORE SECTOR 2026-27 PROGRAMME IN THE DISTRICT OF HOOGHLY
Sl. No. Item Description
1Supply & Delivery of Materials: Supply of 315 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
2Supply of 200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
3Supply of 140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
4Supply of 140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
5Supply of 200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
6Supply of 140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
7Supply of 315 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
8Supply of 200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
9Supply of 160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
10Supply of 160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
11Supply of 200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
12Supply of 200 X 160 mm P.V.C. Reducer (Class-II)
13Supply of 200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
14Supply of 140 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
15Supply of 140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
16Supply of 200 mm dia P.V.C. End Cap(Cl-III)
17Supply of 140 mm dia P.V.C. End Cap(Cl-III)
18Supply of 315 mm dia P.V.C.Extra Coupler (Class-II)
19Supply of 200 mm dia P.V.C.Extra Coupler (Class-II)
20Supply of 160 mm dia P.V.C.Extra Coupler (Class-II)
21Supply of 140 mm dia P.V.C.Extra Coupler (Class-II)
22Supply of Solvent Cement(Exra)
23Supply of Quadrupped Set for Major RLI Scheme
24Supply of 150 mm dia C.I. Sluice Valve as per IS 14846(ISI MARKED)
25Supply of 150 mm dia NB Foot Valve (Flanged type) lS -4038 / 1986
26Supply of 150 mm dia Alfa Alfa type Valve (C type)
27Supply of 90 degree G.I Bend (both end flanged-ISI marked-IS 1239,Galv- IS4736 150 mm dia
28Supply of 90 degree G.I Bend (both end flanged-ISI marked-IS 1239,Galv- IS4736150 mm dia long bend (with priming)
29Supply of Galv. MS Flanged Pipe 151 markec- IS: 1239, Galv- IS4736 150mm.dia (4.8mm) (ISI MARKED)
30Supply & transport of MS Kiosk Box of size 72\\" X 48\\" X 30\\" made with 16 gauge ms sheet fitting and fixing by running welding on (50 X50X6) angle with painting complete as per direction of EIC.
31Supply & transportation of MS Shore manifold with painting made of 350 mm dia MS ERW pipe 900 mm long having 1 numbers of 300 mm dia inlet and 2 nos of 150 mm dia outlet all end flanged welded , MS ERW Pipe conferming to IS 1239(Part-I)/3589 Medium and MS Flanged conferming to IS 6392/719tABLE 17) , Flanged thickness of 315 & 150 mm dia 19 mm thick +3 mm of raised surface.
32Supply and transport of 20 HP Motor cover of size 600 x 600 x 700mm made with 25 x 25 x 5mm angel 2mm thick M.S. sheet with 4 Nos. Handle and Locking arrangement and fitting and fixing by running welding with painting complete as per drawing and direction of EIC.
33300 mm dia Z bend,average length 2 mtr, both end ISI marked flanged of size 300 mm NB, 5.40 mm thick M.S. ERW pipe and 300 mm dia MS plate flanged 12 mm thick with 12 nos drilled hole equally spaced fitting and fixing by running welding with painting complete.
34Supply of MS Hose Clamp150 mm dia (45 mm thick, 2 mm width)
35Supply of C.I. Flanged Tail piece/Nipple150 mm dia.Tail piece one end flanged other end grooved.
36Supply of Foundation BoltFor Distrubution Chamber
37Supply of Foundation BoltFor Diesel Engine Pump Sets
38Supply and Delivery of GI Hexagonal Head Bolts & Nuts conforming to IS-1363 (Part-I) 1992 product grade - C with latest ammedments for boths IS-1363 (Part-3) / 1992 of product grade C with latest amount for nuts properties / class for bolt 4.62 nuts for 4.5. M 20x80 mm.
39M 20x100 mm.
40M.16x65 mm
41M 16x80 mm
42M 16x 50 mm
43Electro Motor Pump set , both having ISI Marked, IS-12615 & IS- 6595; Monoblock as per IS 9079b) 200 M3/hr, 18 m head. (20 HP)
44Switch Fuse Unit, lSI marked, IS 60947 -63 Amps 415 volts A.C TPN Main Switch. (ISI Marked)
45Switch Fuse Unit, Confirming to IS 60947 -200 Amps 415 volts A.C TPN Main Switch.
46MOTOR CONTROLLER, IS 60947 20 HP 3 phase electromagnetic Star- Delta motor controllers with 4 pole heavy duty power contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons, Ammeter & Voltmeter, All in IP54 encolser of min 16 swg. C R Sheet, 10 tank process powder coat painted and as per technical specification.
47Bus Bar Chambers (As per appvd. existing dwg)-IS60947 -200Amp
4850 square mm, 3.5 core Aluminium PVC insulated (Heavy Duty) armoured electric cable duly ISI certification mark as per IS 7098/1988
493C Flat water proof CU.cables lSI marked-IS 694 3CX 10 sq. mm
503C Flat water proof CU.cables lSI marked-IS 694 3CX6 sq. mm
51Compresed Asbestos fibre jointing for Quadruped & Tripod set (for raised surface of Flange as per IS-6392)500 mm.dia (Table-5)
52ISI marked P.V.C.Flexible Hose pipe as per IS 15265 - 150 mm dia
53150 mm dia Foot Valve Leather Washer
54Rubber Insertion (for raised surface of Flange as per IS-6392)300 mm.dia( Table-11)
55200 mm.dia( Table-11)
56200 mm.dia( Table-5)
57150 mm.dia( Table -17)
58150 mm.dia( Table -5)
5980 mm.dia( Table -17)
60Laying of WTA
61Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.
62Earthwork in excavation in the canals / drainage channels / borrow pits / River bed / slope of bank as noted below as per designed section & throwing the spoils in layers of 25 cm. for making banks as per profile or to deposit the same in any other place within an initial lead of 30 metre and initial lift of 1.5 metre including breaking clods, rough dressing etc. complete as per direction of the Engineer-in-charge.(a) Ordinary soil / local soil / soil mixed with moorum or kankar / silt, dryor moist / slushy silt / sticky soil.
63Laying of PVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipesfittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge. i)315 mm.dia
64ii)200 mm. dia
65iii)140 mm. dia
66Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.)
67Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
68Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
691:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
70Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
71Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns
72Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars
73Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand)
74Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
75Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
7615 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
77Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
78Fitting and fixing of M.S. I G.I. I C.l.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge.(iv) 150mm. dia. C.1.sluice valve
79Labour charges for fitting and fixing and laying , where necessary of fowlling M.S/G.I. /E.R.W pipes and accessories (to be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., maintaing the proper alignment and level / all complete / as per direction of E-I-C. (a) 150 mmm dia E.R.W Pipe.
80Erection, fitting and fixing set of M.S Quadrupped inlet and outlet pipe fittings for Ist chamber and 2nd chamber of Major RLI scheme.(Rate inclusive of transportation from Deptt. Store to work site).
81Installation / Erection of SurgeTank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of cement concrete (1`:2:4) with stone chips 20mm. down of 1250 mm X 1250 mm X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concrete base including cost of all materials and labour and as per direction of Engineer-in-Charge.
82Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme ( one at rode side and other at site) the board will be made 3 mm thick MS plate of 300 mm X 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-I) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soilng. This will include one materials and labour complite as per drawing and direction of EIC.
83Placing and positioning the Centrifugal pump motor set on the pump base / pump house floor, aligning properly with necessary packing and fixing the set with holding down nuts and washerincluding cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages complete as per direction of the Engineer-in-Charge.
84Labour charges for fitting and fixing 150 mm. diaAlfa Alfa G type valve with 140 mm. dia class-II U.P.V.C riser pipe with the help of flanged P.V.C tail piece by joining the P.V.C end of Tail piece and riser pipe with coupler and flanged end of tail piece and flap valve with rubber insertion , nuts and bolts etc. complete.
85Testing of pipe line system against leakage by fillinh the distribution chamber with water and supplying water through the entire pipe line net work for atleast4 (Four) hours including hiring and transport of suitable generstor , pump , tools and plants, fuel and lubricants and installation of the pump connecting the same with pipe line network making necessary electrical connection and dismantling all these after completion of test all complete as per direction of Engineer -In -Charge.
86Carriage charge on every item from Sl. no-3a,3b,3c,6,16,17,18,19,21,22)
87Cost indices of Purba Bardhaman as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is -[{(Total Amount- Item No.- 2,3,4,6,16,17,18,19,20,21,22,23,24) x 0.973}x1.09] + (Cost of Item No.-2,3,4,6,16,17,18,19,20,21,22,23,24)
88Add GST 18% on item no 2,3,4,6,16,17,18,19,20,21,22,23,24
89Add Cess 1% on item no 2,3,4,6,16,17,18,19,20,21,22,23,24 & 2.28
90Internal Wiring of Kiosk Box
91Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 mAll kinds of soil.
92Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
93Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :.1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
94Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand)
9515 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
96Neat cement punning.
97Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all.
98Supply,Fitting & fixing of DPIC main switch 15/16 A 250 Volts (Havells, Surya, BPC ) on Iron legs on wall including mending good the damage for light circuit of pump house.
99Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set.
100Wiring from 15/16A DPIC main switch to Busbar box in 1.1 KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 X 36/0.3(2.5 Sq. mm) +1 X 22/0.3 (1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc including supply of wire.
101Wiring from 15/16A DPIC main switch to BDB in 1.1 KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc.incl supply of wire.
102Distribution wiring in 1.1 KV grade 2 X 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1 X 22/0.3 1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessaiy PVC clips,fittings etc. to light/fan/calling bell with piano key type switch (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works incl. supply of wire.[PVC casing capping and switch board both on surface] average run 5 meter
103Distribution wiring in 1.1 KV grade 2 X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to 5 amps 3 pin flush type plug socket with piano key type switch (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works. [PVC casing capping and switch board both on surface] average run 1.5 meter(PWD elec. Sh. Page-E-22,item- 5(6)
104Fixing only TPN switch fuse units in sheet steel encloser with HRC Fuses on angle iron frame on wall for 32A to 400A200 Amps On angle iron frame (PWD (E)Schedule 2017,C-1 item No. 2)
105Fitting & fixing of 63 A 415 V iron clad/ sheet steel TP/ TPN main switch/isolators on iron legs on wall
106Fitting & fixing of only 415V iron clad M.S. sheet metal busbar chamber on angle iron frame on wall for 4 bars 63Amps. .
107Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) [a] For Major RLI. (i) 4Cx 25 sqmm Copper cable conforming to IS 694 ( Meter to 200 A main switch and main switch to 200A BUS-bar )
108(ii) 3C X 16 sqmm copper cable conforming to IS 694 and 63 A TP switch to Motor starter]
109(iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI-Medium quality) IfStar-DeltaMotor starter to Motor]
110Suppling & fitting & fixing of danger Board (mannual) 4\\"x 6\\" in two distinguishing position in the door of pump house (outside) and at the place of panel board
111Suppling fitting & fixing of shock treatment chart in a wooden frame with brass.
112Earthing with 50 mm (2\\") dia Galvanized iron pipe 3.64 mm thick X 3.04 mtr.(10 ft) long and 1 X 4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (½\\") dia X 80 mm (3\\") long G.I. Bolts, double nuts and double washer including S & F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12\\") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe
113Supplying and fixing earth bar of galvanized M.S. Flat 25 mm x 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping.
114Connecting the equipments to earth busbar including supplying and fixing G.I. wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages. .
115Insulation testing of internal wiring of Pump House/Kiosk Box including wiring ofelectric Motor & other ancilary equipments by means of Megger
116Cost indices of Purba Bardhaman as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is -[{(Sub-Total - Item No.- 2,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25) x 0.973}x1.09] + (Cost of Item No.-2,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25)
117Add GST @18% on item no. 2,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25
118Add Cess@ 1% on item no. 2,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25& (C)
119WUA Formation and Registration
120Campaigning in the command area of New Major RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.
121Demarcation of command area, selection of beneficiaries and preparation of land schedule within the Command area of one New Major RLI having CCA 80 Ha
122Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges
123Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C etc.
124Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting )
125Meeting and onsite demonstration for operation & maintenance of one New Major RLI tubewell, water manangement and mode of collection of water tax, building of corpus fund etc
126IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 4.02 and SL - 4.04
127Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.
128Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period
129ENERGISATION: (Meterial Cost) PCC Pole 9 Meter Long )
130MS Channell 75x40 mm
131MS Angle 65 x 65 x 6 mm
132MS Flat 65x6 mm
13311 KV -Bracket for PCC pole 9 Mtr.
13411 KV -Top Adoptor for PCC pole 9 Mtr.
135GI STAY SET HT(1830%20MM)WRKG LD-7900KG (0504130432)
136Stay wire 7/3.15 swg
137Porcelain Guy Insulator H.T.
138GI EARTH SPIKE 1833X20MM
139G.I. WIRE 5MM.
14011 KV Polymer Disc insulator 45 KN.
141Hardware fittings 30/50 sq.mm.
14211 KV 230 mm Polymer Pin insulator.
143TPGO Isolator 200 Amps.
144Transformer 63 KVA
145Turn buckle.
146COND ACSR 50 sq mm.
1471.1 KV PVC 4C 50 SMM AL CABLE
148LT DIST KIOSK FOR 63 KVA ,TRNF(SMC/FRP)
149LA 12 kv (5 KA) FOR 11 KV
150Labour Cost: Survey of H.T.O.H. line.
151Painting of GIS Code
152Survey of GIS. Point
153Erection of Sub-Stn. D.P. structure by PCC Pole 9 Mtr. Long Comp. with all fittings and foundation but w/o any insulator and without paint.
154Erection of single PCC Pole 9 Mtr. Long.Comp. with all fittings and foundation , but W/O any insulator and with paint
155Erection of Stay set comp. L.T.
156Earthing Complete.
157Fixing of solid Tee-off bracket on double pole.
158Stringing & Sagging of ACSR 50 sq.mm.3-wire
159Fixing of 11 KV TPGO Isolator on Sub-Stn.structure with proper adjustment.
160Fixing of 11 KV Pin insulator.
161Fixing of 11 KV Disc insulator.
162Erection of Dist.Transformer 63 KVA,11/0.43.
163Pipe Earthing for DTR Neutral point
164Fixing of 11 KV Lightning Arrestor on structure.
165Fixing of LT kiosk and comp. connection, single QKT
166Service Connection with Metering
167Supervission Charge @10% (On materials +labour)
168Cess @ 1% on Above
169GST @ 18% on Labour Charge and Supervision
170Quotation Money as per WBSEDCL Procedure Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58248487
AUTHORITY Government Departments
TENDER VALUE 73.11 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Installation Of Of Chattrasal Uttarpara Major Rli Scheme ( Including Supply And Delivery Of All Related Materials , All-In-One Works On Turn Key Basis ) Under Ch Adanga (A-M) Sub Division Under Chinsurah (A-M) Division Under Core Sector 2026-27 Programme In The District Of Hooghly
Basic Detail
Tender No WBWRDD/SE (AM)/Res Circle/eNIT-65(Sl. 1 to 2)/2026-27
Bidding Type Tender
Location
City Hooghly
State West Bengal
Key Dates
Publish Date 28 Oct 2026
Submission Date 25 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 73.11 Lakhs
Tender Fee Ref. Documents
EMD 1.46 Lakhs
Exemption Available
Document List
9900aa15-9751-4e17-9155-10bd50db9993.html
BOQ_2565580.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

9900aa15-9751-4e17-9155-10bd50db9993.html

xls

BOQ_2565580.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender