Tender For Construction Of 01 No. Proposed 33 Kv Industrial Corridor Bay, Dismentaling, Shifting & Erection Of 10 Mvar Capacitor Bank (Under Deposit Head) And Other Related Misllaneous Works At 132/33Kv Substation Kabrai Under Etd Hamirpur.
Tender Overview
Project Description
Tender for Construction Of 01 No. Proposed 33 Kv Industrial Corridor Bay, Dismentaling, Shifting & Erection Of 10 Mvar Capacitor Bank (Under Deposit Head) And Other Related Misllaneous Works At 132/33Kv Substation Kabrai Under Etd Hamirpur.
BOQ
| Sl. No. | Item Description |
| 1 | Construction of 01 no. 33kV INDUSTRIAL CORRIDOR Bay alongwith other associated works at 132 KV S/S KABRAI under ETD Hamirpur, with all cost of men, misc. materials, consumables, T&P etc. required for satisfactory completion of the work as per Technical Specification and Direction of the Supervising Engineer, as per Details below:- |
| 2 | Stringing work of 33kV Transfer Bus with single Panther respectively approx 18mtr length of each phase.The work include cutting,bending of conductor,fixing of bolites type tension fitting,suspension fitting hoisting of disc insulator connecting with exixting main and trasfer bus alongwith shifting of material from store to work site. |
| 3 | Erection of following auxiliary and main structures of 33 KV bus isolator, line isolator,PT and CT for construction of 01 No. proposed 33KV INDUSTRIAL CORRIDOR BAY at 132 KV S/S KABRAI. |
| 4 | Erection of following equipments as per instruction manual and technical specification including shifting of material/equipments from store to erection site including all other associated work to complete the job satisfactorily. |
| 5 | 36 KV VCB Circuit Breaker |
| 6 | 36 KV Bus Isolator without earth switch |
| 7 | 36 KV Line Isolator with earth switch |
| 8 | 36 KV CT |
| 9 | 33 KV CT Junction Box |
| 10 | 36 KV PT |
| 11 | 33 KV PT Junction Box |
| 12 | Installation of 3P4W,0.2 accuracy class Interface Energy meter (one main +one'check) along with meter cubicle |
| 13 | Cutting,strengthening,bending,laying 600mm. below in side ground and above ground of following size of MS Flat for earthing of auxiliary structure, equipment structure and its material etc. including welding with main earthmat and with object to be earthed /excavation of trenches its back filling. |
| 14 | 75X10mm |
| 15 | 50X6mm |
| 16 | 25X6mm |
| 17 | Interconnection of above equipments and bus bar Including cutting, bending of Panther conductor and jumpering, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn. to complete the job satisfactorilly. |
| 18 | Painting of earth riser and earthing flat of above auxiliary structures and equipments having following size by applying one coat of red oxide and two coats of bus green color of Nerolac/Berger/Asian. |
| 19 | 75X10mm |
| 20 | 50X6mm |
| 21 | 25X6mm |
| 22 | Laying of following sizes of control cable in the cable trench from control relay panel to various equipments/marshalling boxes/I.B. etc. In switch yard as per cable schedule, its saddelling at every 75cm. distance with AI saddles of size 25x3 mm. Size including carriage of cable drums from store to laying site and shifting back to store and all other associated work to complete the job satisfactorily as per technical specification. |
| 23 | 2Corex2.5 sq. mm |
| 24 | 4Corex2.5 sq. mm |
| 25 | 6Corex2.5 sq. mm |
| 26 | Termination of following sizes of control cable as laid above as per cable schedule including making necessary holes in glands plates or box wherever required, providing and fixing of cable glands. appropriate size, supply and providing ferrules and Nos. for each core of cable and its termination with crimping type lugs of Dowell/Tension make and all other associated work to complete the jobs satisfactorily as per technical specification. |
| 27 | 2Cx2.5 Sq. mm. Unarmoured |
| 28 | 4Cx2.5 Sq. mm. Unarmoured |
| 29 | 6Cx2.5 Sq. mm. Unarmoured |
| 30 | Work of complete shifting, disementalling and re-erection of 2*5=10MVAR capacitor bank alongwith other associated works at 132 KV S/S KABRAI under ETD Hamirpur, with all cost of men, misc. materials, consumables, T&P etc. required for satisfactory completion of the work as per Technical Specification and Direction of the Supervising Engineer, as per Details below:- |
| 31 | Dismantling work of main/ auxiliary structure without any damage equipment including other associated work to complete this job satisfactorily. |
| 32 | Dismantling work of main/ auxiliary structure without any damage equipment including other associated work to complete this job satisfactorily. |
| 33 | 36KV CT/CT WITH JB |
| 34 | 36KV PT WITH JB |
| 35 | 36KV LINE ISOLATOR |
| 36 | 36KV REACTOR |
| 37 | 36KV CAPACITOR UNIT |
| 38 | De-stringing of 33KV busbar for 10mvar capacitor bank (1Mx25) Moose /panther conductor approx 25meter long Including dismantling of disc insulator and bolted type panther tention fitting including other associated work to complete this job satisfactorily. |
| 39 | Safe Dismantling & collection of control cable of size 2Cx2.5mm sq 4Cx2.5mm sq 6Cx2.5mm sq & 10Cx2.5mm sq from control room to various equipments And shifted to store or designated place. |
| 40 | Opening work of jumpering of 33KV Bay by moose/panther conductors including other associating work etc. |
| 41 | Dismantling/cutting of earthing of main/ auxiliary structure and all dismetalled equipment CPR CT/PT, NCTS ISOLATOR CT/PT Junction box, including other associated work to complete this job satisfactorily. |
| 42 | Safe shifting with sorting and stacking of main/ auxiliary steel structure from designated place store to erection site as direction by concerning engineer with help of required special T&p and skilled labour at own cost. |
| 43 | Erection of main/ auxiliary structure as per drawing Including other associated work to complete this job satisfactorily.(CCM-6nos,CGM-03,CT- 03,PT set,NCT-02,Reactor-12 and 2set support of capacitor bank etc) |
| 44 | Safe erection of following equipments as per drawing including other associated work to complete this job satishfactorily with the help of requited special t&p or crane and skilled labour. |
| 45 | 36 KV VCB Circuit Breaker |
| 46 | 36 KV Bus Isolator without earth switch |
| 47 | 36 KV Line Isolator with earth switch |
| 48 | 36 KV CT & NCT |
| 49 | 33 KV CT Junction Box |
| 50 | 36 KV PT |
| 51 | 33 KV PT Junction Box |
| 52 | 36KV REACTOR |
| 53 | 36KV CAPACITOR UNIT (1X5MVAR) |
| 54 | Stringing of 33kv busbar for 10mvar capacitor bank (1x30) Moose /Panther conductor approx 25meter long with hoisting of disc insulators and clamping bolted type panther tension fitting including other associated work to complete this job satisfactorily |
| 55 | Complete jumpering work of 33kv Bay by panther/moose conductors including cutting, laying, fixing& clamping etc. |
| 56 | Laying of 40mm dia. M.S. round bar 800 mm below ground level including cutting, welding, painting, excavation of trench, partially on rocky land and fishered soil, its back filling and all other associated works to complete the work satisfactorily and interconnection with existing earthmat mesh as per drawing and technical specification for construction of Capacitor Bank at 132 kV S/S KABRAJ. |
| 57 | Cutting, Fabrication and fixing of angle iron by welding including cost of electrodes, labour, T&P. Details of every job includes - (a) Taking out scrap angle heap of scrap, cutting the cleats of 2X(25x6) mm angle iron & shifting back the scrap (scrap angle iron will be provided by department). (b) Fixing of cleats of angle iron by welding including cost of electrodes, labor, T&P. |
| 58 | If required fabrication of 03 Mtr. long Electrode with 40mm dia. M.S. round bar having 150 mm long conical shape and then its piercing vertically in side the ground with top 500mm.below ground level and its welding with earthmat including all labour and T&P. |
| 59 | Cutting strengthening bending laying 600mm. below in side ground and above ground of following size of MS Flat for earthing of auxiliary structure, equipment structure and its material etc. including welding with main earthmat and with object to be earthed /excavation of trenches its back |
| 60 | 75X10mm |
| 61 | 50X6mm |
| 62 | 25X6mm |
| 63 | Painting of earth riser and earthing flat of above auxiliary structures and equipments having following size by applying one coat of red oxide and two coats of bus green color of Nerolac/Berger/Aslan. |
| 64 | 75X10mm |
| 65 | 50X6mm |
| 66 | 25X6mm |
| 67 | Laying of following sizes of control cable in the cable trench from control relay panel to various equipments/ marshalling boxes/I.B. etc. in switch yard as per cable schedule, its saddling at every 75cm. distance with Al saddles of size 25x3 mm. Size including carriage of cable drums from store to laying site and shifting back to store and all other associated work to complete the job satisfactorily as per technical specification. |
| 68 | 2CoreX2.5 sq.mm |
| 69 | 4CoreX2.5 sq.mm |
| 70 | 6CoreX2.5 sq.mm |
| 71 | Termination of following sizes of control cable as laid above as per cable schedule including making necessary holes in glands plates or box wherever required, providing and fixing of cable glands of appropriate size, supply and providing ferrules and Nos. for each core of cable and its termination with crimping type lugs of Dowell/Tension make and all other associated work to complete the jobs satisfactorily as per technical specification. |
| 72 | 2Cx2.5 Sq. mm. Unarmoured |
| 73 | 4x2.5 Sq. mm. Unarmoured |
| 74 | 6Cx2.5 Sq. mm. Unarmoured |
| 75 | Miscleneous work |
| 76 | Supply and fixing of 120 watt LED Lamps Cropmton Greaves, Bajaj/Havells make fitting including lamp, Ballast Igniter etc. For fixing of structure including cost of all material labour and T&P for completion of work. |
| 77 | Supply and fixing of Junction Box on lighting polls of size 200x200x150mm of MS seat SWG duly painted with synthetic enamel paint box should be fixing and Backlite terminal strip of 4 Nos terminal both should be fixing on Sunmica seat and half round MS clamp with Gl pipe for fixing the Junction box on the structure |
| 78 | Supply and fixing of 16 Amp. MCB make Crompton Greaves, Bajaj/Havells make fitting on structure including cost of all material, labour and T&P for completion of work. |
| 79 | Laying of 2x2.5/4x2.5mm sq.mm PVC cable 50 cm below the ground level in PVC conduit pipe after excavation and back filling including all labour PVC pipe etc. |
| 80 | Following Works are to be carried out for Integration of 01 No. 33kV Bay with existing Nelumbo/Schenleder make SCADA system and all associated works at 132KV Sub Station Kabrai with all cost of men, misc. consumables, T&P etc. to complete the job satisfactorily as perirection of the Supervising Engineer |
| 81 | 33 KV Bay (01 No.) Intergration at the existing Siemens make IEC 61850 based SCADA System. |
| 82 | CPT cum Gateway configuration for real time data to be sent to SLDCLucknow and ALDC Moradabad |
| 83 | Configuration of ICD/CID files of the Siemens make REF 615 BCPU relay |
| 84 | Supply and installation of Fiber Optics patch cords/LIUs and splicing work to make BCUs communication with existing fibre ring system |
| 85 | AMR Integration for SAMAST |
| 86 | Necessary Interconnection for Data Transmission of installed SAMAST compliant meters to LAN Switch upto DCU/Gateway and all other H/W, S/W per No. |
| 87 | Installation of communication cable(CAT-6 alongwith neccessary hardware wherever required in between energy meter to LAN switch to SDH equipments upto DCU/Gateway and H/W,S/W. |
| 88 | Installation of OFC cable armoured (6P) in HDPE conduit pipe 32mm. |
| 89 | Laying the 01 Nos. 4x2.5 Sq. mm control cable for CT & PTwith provision of vermin proofing in galv. MS pipe in individual 'B' Class pipe of Jindal/TATA/JSW/SAIL, 1\\" dia with jointing with Tee, Elbow, bend, Socket etc. Including cost of material of pipe and other accessories. Separate pipe will be made in trench for each control cable. Control cable will be provided by the department as per actual consumption. |
| 90 | Providing & fixing work of Name Plate made of 2mm thick aluminium sheets with covering of 3HP retroreflective sheeting of size 300x150 mm plate to be fixed with the help of nuts & bolts of already installed equipment , structures as per sample, provided by department free of cost. |
| 91 | Providing & fixing of Phase Plate equipment (R,Y,B) phase made of 2mm thick aluminium sheets with covering of 3HP retroreflective sheeting of size 5\\" dia plate to be fixed with the help of nuts & bolts of already installed equipment , structures as per sample, provided by department free of cost. |
| 92 | Supply and installation of 2 Ton Split AC with all accessories and stabilizer (Not less than 5KVA capacity) as per UPP TCL spec |
| 93 | Miscellaneous work of Carriage of required materials like Control Cable, MS Flats, MS Round Bar and other Important Items from different Sub-Stations under ETD Hamirpur as per requirement. |
| 94 | Supply Of FLAT,MS,75X10MM |
| 95 | Supply Of FLAT,MS,50X6MM |
| 96 | Supply Of FLAT,MS,25X6MM |
| 97 | Supply Of ROUND,MS,40MM |
| 98 | Supply Of ELECTRODE,MS,40MM,3M |
| 99 | Supply Of PG CLAMP,MOOSE/PANTHER |
| 100 | Supply Of PG CLAMP,PANTHER/PANTHER |
| 101 | Supply Of Bus post clamp suitable for Panther |
| 102 | Supply Of FITT,BLTD,SINGLE TENSION,PANTHER |
| 103 | Supply Of FITT, BLTD, SINGLE SUSPENSION,PANTHER |
| 104 | Supply Of LAN Cable |
| 105 | Supply Of Flexible Copper bond |
| 106 | Supply Of Galvanised cable Tray 18SWG having weight size 225mm |
| 107 | Supply Of Galvanised cable Tray 18SWG having weight size 75mm |
| 108 | Supply Of 70 KN Antifog Disc insulators |
| 109 | Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender