Tender For Construction Of 100 Bedded G+2 Rec Girls Hostel At Kohima Science College, Jotsoma, Nagaland.
Tender Value
2.78 Crore
Estimated cost
Bid Submission
17 Nov 2026
18 days left
EMD
2.78 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kohima → Nagaland
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of 100 Bedded G+2 Rec Girls Hostel At Kohima Science College, Jotsoma, Nagaland.
BOQ
| Sl. No. | Item Description |
| 1 | EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 4 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials. All kinds of soil |
| 5 | CONCRETE WORK |
| 6 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto a floor five level, excluding the cost of centering, shuttering and finishing. 1:3:6 (1 Cement : 3 coarse sand : 6 stone aggregate 20 mm) |
| 7 | RCC WORK :Providing and laying in position machine batched and machine mixed design mix M25 cement concrete for RCC work using cement concrete as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement. Foundations, footings, bases of columns etc. and mass concrete. (All work upto plinth level) |
| 8 | Foundations, Footings. |
| 9 | Base of column |
| 10 | Column |
| 11 | Plinth Beam |
| 12 | Roof Beam |
| 13 | RCC Slab |
| 14 | Staircase |
| 15 | STEEL REINFORCEMENT |
| 16 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Cold twisted bars |
| 17 | FORMWORK |
| 18 | Centering and shuttering including strutting, propping etc. and removal for formwork. Using Timber — Foundations, footings, bases of columns etc. for mass concrete. |
| 19 | Centering and shuttering including strutting, propping etc. and removal for formwork. Using Timber — Columns, Pillars, Piers, Abutments, Posts and Struts |
| 20 | Centering and shuttering including strutting, propping etc. and removal for formwork. Using Timber — Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 21 | Centering and shuttering including strutting, propping etc. and removal for formwork. Using Timber — Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 22 | Centering and shuttering including strutting, propping etc. and removal for formwork. Using Timber — Suspended floors, roofs, landings, balconies and access platform |
| 23 | Centering and shuttering including strutting, propping etc. and removal for formwork. Using Timber — Stairs (excluding landings) except spiral staircase |
| 24 | STONEWORK |
| 25 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded coarse aggregate 20mm nominal size) at plinth level with cement mortar 1:6 (1 cement: 6 coarse sand) |
| 26 | BRICKWORK |
| 27 | Half brick masonry with common burnt clay FPS bricks of class designation 7.5 in superstructure above upto floor V level. Cement mortar 1:4 (1 cement : 3 coarse sand) |
| 28 | WOODWORK |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length. Second Class Teak Wood |
| 30 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer in charge. Second Class Teak Wood — 35mm thick shutters |
| 31 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows. Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Second Class Teak Wood |
| 32 | FLOORING |
| 33 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded coarse aggregate 20mm nominal size) at plinth level with cement mortar 1:6 (1 cement: 6 coarse sand) |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level. 1:2:4 (1 Cement : 2 coarse sand : 4 stone aggregate 20 mm) |
| 35 | Providing and laying rectified glazed ceramic floor tiles of sizes 300x300 mm (thickness specified by manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey, Fume, Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement:4 sand) jointing with grey cement slurry @ 3.3 kg sqm including grouting the joints in white cement mixed with pigment of matching shade etc. complete |
| 36 | Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete. Size of tile 600x600mm |
| 37 | Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours shades, in skirting, risers of steps over 12mm bed of thick cement mortar 1:3 (1 cement : 3 coarse sand) jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete. Size of tile 600x600mm |
| 38 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @2 litre per 50 kg of cement or as per manufacturer's specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 39 | FINISHING |
| 40 | Providing 20 mm cement plaster mix 1:4 (1 cement : 4 fine sand) |
| 41 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers |
| 42 | Providing 12 mm cement plaster mix 1:4 (1 cement : 4 fine sand) |
| 43 | 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand) |
| 44 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 45 | WHITE WASHING / COLOUR WASHING |
| 46 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface — water thinnable cement primer |
| 47 | Finishing walls with delux multi surface paint system for interior and exteriors using primer as per manufactures specifications. Two or more coats applied on wall @1.25ltr/10sqm over and including one coat of special primer applied @ 0.75ltr/10sqm |
| 48 | Applying one coat of cement primer of approved brand and manufacture on wall surface — Cement primer |
| 49 | Finishing walls with textured exterior paint of required shade. New work (Two or more coats applied @ 3.28 Itr/10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 50 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 51 | Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 Sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
| 52 | ALUMINIUM WORKS |
| 53 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners or required dia of size, including necessary filling up to gaps at junction i.e top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P brass/stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting whenever required including the cost of EPDM rubber/neoprene gasket required. Powder coated aluminium |
| 54 | GLASS WORK |
| 55 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and direction of engineer-incharge. With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/m) |
| 56 | FITTINGS FOR DOORS & WINDOWS |
| 57 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm) |
| 58 | Providing and fixing ISI:12817 marked Stainless steel butt hinges with stainless steel screws etc. complete. 100x58x1.90 mm |
| 59 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. Door — 200x10mm |
| 60 | Providing and fixing chromium plated brass handles with necessary screws etc complete. 100mm |
| 61 | Providing and fixing bright finished brass 100mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete |
| 62 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete — twin rubber stopper |
| 63 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS :3564, embossed on the body, door weight upto 36 kg to 80kg and door width 701mm to 1000mm), with double speed adjustment with necessary screws etc complete. |
| 64 | Providing and fixing bright finished brass door latch with necessary screws etc. complete. 250x16x5mm |
| 65 | STEEL WORK |
| 66 | Providing and fixing stainless steel (grade 304) railing made of hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (whenever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railings with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor of the sides of waist slab with suitable arrangement as per approval of engineer incharge |
| 67 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws |
| 68 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 69 | SITE DEVELOPMENT - Earthwork |
| 70 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30cm in depth, 1.5m in width as well as10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.A2.6.1 All kinds of soil |
| 71 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 72 | SANITARY INSTALLATIONS |
| 73 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.A17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type |
| 74 | Providing and fixing wash basin with CI/MS brackets 15mm CP brass pillar taps, 32mm CP brass waste of std pattern , including paining of fittings and brackets, cutting and making good the walls wherever required A17.7.4 White Vitreous China Flat back wash basin size 550x400mm with a pair of 15mm CP brass pillar tap |
| 75 | Providing and fixing with vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fttings |
| 76 | ACCESSORIES |
| 77 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.A17.28.1 Semi Rigid pipeA17.28.1.2 40 mm dia |
| 78 | Providing and fixing 100mm sand cast iron grating for gullytrap |
| 79 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 80 | Providing and fixing toilet paper holderA17.34.1 CP brass |
| 81 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than105gms |
| 82 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arangement of approved colour and makeA17.73.1 450mm long towel rail with total length of 495 mm,width 78mm and effective height of 88mm, weighing notless than 170 gms |
| 83 | Providing and fixing C.P. Brass long nose bib cock of approved quality conforming to IS std and not weighing less than 810 gmsA18.50.1 15 mm nominal bore |
| 84 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931A18.52.1 15 mm nominal bore |
| 85 | SOIL, WASTE AND VENT PIPES |
| 86 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermalexpansion.(Singlesocketed pipes):A12.41.2 110 mm diameter |
| 87 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermalexpansion.(Singlesocketed pipes):A12.41.1 75 mm diameter |
| 88 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap forthermal expansion.:A12.42.3 Single tee with doorA12.42.3.2 110x110x110 mm |
| 89 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap forthermal expansion.:A12.42.5 Bend 87.5°A12.42.5.2 110 mm bend |
| 90 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap forthermal expansion.:A12.42.4 Single tee without door |
| 91 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap forthermal expansion.:A12.42.2 Single Pushfit CouplerA12.42.2.2 110 mm |
| 92 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap forthermal expansion.:A12.42.1 CouplerA12.42.1.2 110 mm |
| 93 | Providing and fixing unplasticised -PVC pipe clips to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed withM.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 and making good the wall etccomplete:A12.43.1. 75 mm |
| 94 | Providing and fixing unplasticised -PVC pipe clips to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed withM.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 and making good the wall etccomplete:A12.43.2 110 mm |
| 95 | Providing and fixing PTMT Bottle Trap for Wash basin and sink (Prayag or equivalent) A17.70.2 Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less that 263gms. |
| 96 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: A23.3.1 100 mm diameter S.W. pipe |
| 97 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:A2.10.1 All kinds of soil. A2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but notexceeding 300 mm dia. |
| 98 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design :A19.3.3 200 mm diameter S.W.pipe |
| 99 | EXTERNAL & INTERNALWATER SUPPLY |
| 100 | Providing and fixing Cholrinated Polyvinyl Cloride (CPVC) pipes, ainvg thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe wit clamps at 1 m spacing. Tis includesjointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good te same including testing of joints complete as per direction of engineer in charge.External work:A 18.9.2 20mm dia. nominalbore |
| 101 | Providing and fixing Cholrinated Polyvinyl Cloride (CPVC) pipes, ainvg thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe wit clamps at 1 m spacing. Tis includesjointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good te same including testing of joints complete as per direction of engineer in charge Concealed work, including cutting chases and making good the walls etc.A18.8.1 15mm dia. nominalbore |
| 102 | Providing and fixing Cholrinated Polyvinyl Cloride (CPVC) pipes, ainvg thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe wit clamps at 1 m spacing. Tis includesjointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good te same including testing of joints complete as per direction of engineer in charge Concealed work, including cutting chases and making good the walls etc.A18.8.2 20mm dia. nominalbore |
| 103 | Providing and fixing ball valve (brass) of approved quality high or low pressure, with plastic floats completeA18.18.1 15 mm nominal bore |
| 104 | Providing and fixing ball valve (brass) of approved quality high or low pressure, with plastic floats completeA18.18.2 20 mm nominal bore |
| 105 | SOAK PIT |
| 106 | Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 107 | SEPTIC TANK |
| 108 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. A2.6.1 All kinds of soil |
| 109 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto a floor five level, excluding the cost of centering, shuttering and finishing. A4.2.5 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 110 | Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in A6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 111 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. A11.3.1 40mm thick with 20mm nominal size stone aggregate |
| 112 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: A13.8.1 1:3 (1 cement : 3 fine sand) |
| 113 | Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, copings, anchor blocks plain window sills and the like including the cost of required centring, shuttering, but excluding cost of reinforcement with 1:1.5:3(1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm |
| 114 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .A5.22.3 Cold twisted bars |
| 115 | Supplying and fixing C.I. cover without frame for manholes: A19.18.2 500mm diameter CI cover (medium duty) the weight of the cover to be not less than58kg |
| 116 | UNDERGROUND WATER RESERVOIR |
| 117 | EARTH WORK:Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30cm in depth, 1.5m in width as well as10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.A2.6.1 All kinds of soil |
| 118 | CONCRETE WORKProviding and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto a floor five level, excluding the cost of centering, shuttering and finishing.A4.2.5 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 119 | RCC WORKProviding and laying in position machine batched, machine mixed and machine mixed design mix M25 cement concrete for RCC work using cement concrete as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement. including admixtures in recommended proportions.( as per IS 9103) to accelerate, retard setting of concrete improve workabilty without impairing strength and durability as per direction ofEngineer-in-charge:Total for RCC Slab: |
| 120 | RCC WORKProviding and laying in position machine batched, machine mixed and machine mixed design mix M25 cement concrete for RCC work using cement concrete as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement. including admixtures in recommended proportions.( as per IS 9103) to accelerate, retard setting of concrete improve workabilty without impairing strength and durability as per direction ofEngineer-in-charge:Total for RCC Wall: |
| 121 | STEEL REINFORCEMENTReinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . A5.22.3 Cold twisted bars |
| 122 | FORMWORK:Centering and shutteringincluding strutting, propping etc. and removal for formwork. A5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 123 | STEEL WORK:Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required. A10.25.2 In gratings, frames.ladders,railings, brackets, gates & similar |
| 124 | STEEL WORK:Supplying and fixing C.I. cover without frame for manholes: A19.18.2 500mm diameter CI cover (medium duty) the weight of the cover to be not less than58kg |
| 125 | FINISHING:15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: A13.8.1 1:3 (1 cement : 3 finesand) |
| 126 | FINISHING:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers |
| 127 | WHITE WASHING/COLOUR WASHING.:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.A13.52.1 On steel work |
| 128 | GST @ 5.31 % as per NO.CE(H)/TB/CORR/GST/2018 Kohima: Dated 9th Nov' 2022. Inclusive of GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender