Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation; As Per Boq - Safe Carriage Of St/Pcc Pole 11/8.5 Mtr. Long From Esc, Mainpuri To Pit Site Of Work Inc
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation; As Per Boq - Safe Carriage Of St/Pcc Pole 11/8.5 Mtr. Long From Esc, Mainpuri To Pit Site Of Work Including Loading And Unloading At Both Ends. Distance Approx 05 To 30 Km. , Safe Carriage Of Small Line Material From Esc, Mainpuri To Pit Site Of Work Including Loading And Unloading At Both Ends. Distance Approx 05 To 30 Km. , Erection Of 11/8.5 Mtr. Long St/Pcc Poles By Excavation Of Earth 1.5 Mtr. Deep And Backfilling Properly. , Grouting Of St/Pcc Pole & Earth Rod Complete With Cement, Sand And Stone Ballast In Ratio 1:4:8 Including Cost Of Material I.E. Cement, Sand And Stone Ballast As Per Actual Site Requirement. , Erection And Grouting Of Stay In Cc Ratio 1:4:8 Of Cement, Sand And Stone Ballast Including Cost Of Grouting Material With Nozelling And Binding Of Stay Wire (Complete Work) , Laying Of Acsr Weasel/Dog For Construction Of Ht/Lt Lines Including Stringing And Sagging Nozelling And Binding Conductor With Insulator. , Fixing Of 11 Kv Cross Arm 65X65x6 Mm. V Type With Clamp And Nuts And Bolts , Fixing Of 11Kv F-Clamps With Clamps, Nut & Bolts. , Fixing Of 11Kv Pin Insulator With Pin & Nut , Fixing Of 11Kv Disc Insulator With Fitting. , Fixing Of Ms T-Off Channel With Clamp Nut And Bolts Etc. And All Respective Material As Per Norms , Safe Carriage Of Single Phase 16Kva/25Kva/63Kva/100 Kva/ Transformer From Esc Mainpuri Including Loading And Unloading At Both Ends, Distance Approx 05 To 30 Km. , 16Kva 11/0.25 Kv 1-Phase Transformer , 25 Kva Alluminium Wound 11/0.4 Kv Transformer , 63 Kva 11/0.4 Kv Transformer , 100 Kva Distribution Transformer , 250 Kva Distribution Transformer , Construction Of Double Pole With All Respective Materials And Mounting Of 16Kva/25Kva/63Kva/100 Kva Transformer On Single Pole/Double Pole With All Respective Material (As Per Respo Schedule And Requirements) Etc. , 16Kva 11/0.25 Kv 1-Phase Transformer , 25 Kva Alluminium Wound 11/0.4 Kv Transformer , 63 Kva 11/0.4 Kv Transformer , 100 Kva Distribution Transformer , 250 Kva Distribution Transformer , Earthing Of Distribution Transformer At Water Level With Gi Strip Patti As Per Respo Mannual. , Conturction Of Plinth 2X2x1.5 Mtr. As Per Respo Norms , Construction And Installation Of Fencing Including Civil Work For 10X10x6 Feet For 250 Kva Distribution T/F. As Per Respo Norms. , Laying Of 11Kv Xlpe 3X70 Sq.Mm. Cable At Different Places Along With Cost Of Digging (As Per Norms, Brick And Sand) Under Eudd Mainpuri As Per Respo Norms. , Providing & Fixing Of Indoor/Outdoor Type Jointing Kit Suitable For 11 Kv 3X70 Sq.Mm. Xlpe Cable , Providing & Fixing Of Straight Through Jointing Kit For 3X70 Sq.Mm. Cable , Laying Of 11Kv Xlpe 3X120 Sq.Mm. Cable At Different Places Along With Cost Of Digging (As Per Norms, Brick And Sand) Under Eudd Mainpuri As Per Respo Norms. , Providing & Fixing Of Indoor/Outdoor Type Jointing Kit Suitable For 11 Kv 3X120 Sq.Mm. Xlpe Cable , Providing & Fixing Of Gi Pipe 6 Dia. , Providing & Fixing Of 4X25 Sq.Mm. Armoured Cable As Per Norms , Laying Lt Ab Cable (3X50+1X35+1X16+1X25) Sq.Mm. With 5% Sag , Laying Cable (3.5X700) Sq.Mm. , Laying Cable (2X16) Sq.Mm. , Providing And Fixing Gaurding With Angle, Clamp, Nut&Bolts. With Gi Wire 6/8/10 Swg. (47 Span) , Fixing Of Single Phase / Three Phase Distribution Box With Clamp As Per Norms. , Fixing Of 11 Kv Pilfer Proof Metering Cubical As Per Norms , Providing And Fixing Tailless Unit Protection Cubical Pannel 500 A, 650 V For 250 Kva Dtr. As Per Norms , Providing And Fixing Lt Protection Dtr For 9 Nos. 100 Kva T/F With Box And All Respective Material As Per Norms. , Providing & Fixing Of Suspension Clamps & I Hook For Pcc/Stp. , Providing & Fixing Of Dead End Clamps With Eye Hook For Pcc/Stp. , Installation Of 11Kv Tpmo Set. , Providing & Fixing Of Different Type Clamp, Nut & Bolt Off Size By The Contractor. , Providing And Fixing Stone Pad 300X300x75 Mm. , Providing And Fixing Aluminium Tape , Providing And Fixing I Bolts With Nut And Bolts As Per Norms , Providing And Fixing Barbed Wire As Per Norms , Received Back Of 25 Kva Transformer From Pit Site To Esc, Mainpuri
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Safe carriage of ST/PCC Pole 11/8.5 Mtr. Long from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx 05 TO 30 KM. | Safe carriage of ST/PCC Pole 11/8.5 Mtr. Long from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx 05 TO 30 KM. |
| 2 | Safe carriage of small line material from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx 05 TO 30 KM. | Safe carriage of small line material from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx 05 TO 30 KM. |
| 3 | Erection of 11/8.5 Mtr. Long ST/PCC Poles by excavation of earth 1.5 mtr. deep and backfilling properly. | Erection of 11/8.5 Mtr. Long ST/PCC Poles by excavation of earth 1.5 mtr. deep and backfilling properly. |
| 4 | Grouting of ST/PCC Pole & Earth Rod Complete with Cement, Sand and Stone Ballast in ratio 1:4:8 including cost of material i.e. Cement, Sand and Stone Ballast as per actual site requirement. | Grouting of ST/PCC Pole & Earth Rod Complete with Cement, Sand and Stone Ballast in ratio 1:4:8 including cost of material i.e. Cement, Sand and Stone Ballast as per actual site requirement. |
| 5 | Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work) | Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work) |
| 6 | Laying of ACSR Weasel/Dog for construction of HT/LT Lines including stringing and sagging nozelling and binding conductor with insulator. | Laying of ACSR Weasel/Dog for construction of HT/LT Lines including stringing and sagging nozelling and binding conductor with insulator. |
| 7 | Fixing of 11 KV CROSS ARM 65X65X6 mm. V TYPE WITH CLAMP and Nuts and Bolts | Fixing of 11 KV CROSS ARM 65X65X6 mm. V TYPE WITH CLAMP and Nuts and Bolts |
| 8 | Fixing of 11KV F-Clamps with Clamps, Nut & Bolts. | Fixing of 11KV F-Clamps with Clamps, Nut & Bolts. |
| 9 | Fixing of 11KV Pin Insulator with Pin & NUT | Fixing of 11KV Pin Insulator with Pin & NUT |
| 10 | Fixing of 11KV Disc insulator with fitting. | Fixing of 11KV Disc insulator with fitting. |
| 11 | Fixing of MS T-Off Channel with Clamp Nut and Bolts etc. and all respective material as per Norms | Fixing of MS T-Off Channel with Clamp Nut and Bolts etc. and all respective material as per Norms |
| 12 | Safe carriage of Single Phase 16KVA/25KVA/63KVA/100 KVA/ transformer from ESC Mainpuri including loading and unloading at both ends, Distance Approx 05 TO 30 KM. | Safe carriage of Single Phase 16KVA/25KVA/63KVA/100 KVA/ transformer from ESC Mainpuri including loading and unloading at both ends, Distance Approx 05 TO 30 KM. |
| 13 | 16KVA 11/0.25 KV 1-PHASE Transformer | 16KVA 11/0.25 KV 1-PHASE Transformer |
| 14 | 25 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER | 25 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER |
| 15 | 63 KVA 11/0.4 KV TRANSFORMER | 63 KVA 11/0.4 KV TRANSFORMER |
| 16 | 100 KVA Distribution Transformer | 100 KVA Distribution Transformer |
| 17 | 250 KVA Distribution Transformer | 250 KVA Distribution Transformer |
| 18 | Construction of Double pole with all respective materials and Mounting of 16KVA/25KVA/63KVA/100 KVA Transformer on Single Pole/Double Pole with all respective material (As per RESPO Schedule and requirements) etc. | Construction of Double pole with all respective materials and Mounting of 16KVA/25KVA/63KVA/100 KVA Transformer on Single Pole/Double Pole with all respective material (As per RESPO Schedule and requirements) etc. |
| 19 | 16KVA 11/0.25 KV 1-PHASE Transformer | 16KVA 11/0.25 KV 1-PHASE Transformer |
| 20 | 25 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER | 25 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER |
| 21 | 63 KVA 11/0.4 KV TRANSFORMER | 63 KVA 11/0.4 KV TRANSFORMER |
| 22 | 100 KVA Distribution Transformer | 100 KVA Distribution Transformer |
| 23 | 250 KVA Distribution Transformer | 250 KVA Distribution Transformer |
| 24 | Earthing of Distribution Transformer at water level with GI Strip Patti as per Respo Mannual. | Earthing of Distribution Transformer at water level with GI Strip Patti as per Respo Mannual. |
| 25 | Conturction of Plinth 2x2x1.5 Mtr. as per Respo Norms | Conturction of Plinth 2x2x1.5 Mtr. as per Respo Norms |
| 26 | Construction and Installation of Fencing Including Civil work for 10x10x6 Feet for 250 KVA Distribution T/F. as per Respo Norms. | Construction and Installation of Fencing Including Civil work for 10x10x6 Feet for 250 KVA Distribution T/F. as per Respo Norms. |
| 27 | Laying of 11KV XLPE 3x70 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms. | Laying of 11KV XLPE 3x70 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms. |
| 28 | Providing & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X70 SQ.MM. XLPE CABLE | Providing & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X70 SQ.MM. XLPE CABLE |
| 29 | Providing & Fixing OF STRAIGHT THROUGH JOINTING KIT FOR 3X70 Sq.Mm. Cable | Providing & Fixing OF STRAIGHT THROUGH JOINTING KIT FOR 3X70 Sq.Mm. Cable |
| 30 | Laying of 11KV XLPE 3x120 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms. | Laying of 11KV XLPE 3x120 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms. |
| 31 | Providing & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X120 SQ.MM. XLPE CABLE | Providing & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X120 SQ.MM. XLPE CABLE |
| 32 | Providing & Fixing of GI Pipe 6\\" dia. | Providing & Fixing of GI Pipe 6\\" dia. |
| 33 | Providing & Fixing of 4x25 Sq.mm. Armoured Cable as per Norms | Providing & Fixing of 4x25 Sq.mm. Armoured Cable as per Norms |
| 34 | Laying LT AB CABLE (3X50+1X35+1X16+1X25) SQ.MM. WITH 5% SAG | Laying LT AB CABLE (3X50+1X35+1X16+1X25) SQ.MM. WITH 5% SAG |
| 35 | Laying CABLE (3.5X700) SQ.MM. | Laying CABLE (3.5X700) SQ.MM. |
| 36 | Laying CABLE (2X16) SQ.MM. | Laying CABLE (2X16) SQ.MM. |
| 37 | Providing and Fixing Gaurding with Angle, Clamp, Nut&Bolts. With GI wire 6/8/10 SWG. (47 span) | Providing and Fixing Gaurding with Angle, Clamp, Nut&Bolts. With GI wire 6/8/10 SWG. (47 span) |
| 38 | Fixing of single phase / Three Phase Distribution Box with Clamp as per Norms. | Fixing of single phase / Three Phase Distribution Box with Clamp as per Norms. |
| 39 | Fixing of 11 KV Pilfer Proof metering Cubical As per Norms | Fixing of 11 KV Pilfer Proof metering Cubical As per Norms |
| 40 | Providing and Fixing Tailless Unit Protection Cubical Pannel 500 A, 650 V for 250 KVA DTR. As per Norms | Providing and Fixing Tailless Unit Protection Cubical Pannel 500 A, 650 V for 250 KVA DTR. As per Norms |
| 41 | Providing and Fixing LT Protection DTR for 9 Nos. 100 KVA T/F with Box and all respective material as per Norms. | Providing and Fixing LT Protection DTR for 9 Nos. 100 KVA T/F with Box and all respective material as per Norms. |
| 42 | Providing & Fixing of Suspension Clamps & I Hook for PCC/STP. | Providing & Fixing of Suspension Clamps & I Hook for PCC/STP. |
| 43 | Providing & Fixing of Dead End Clamps with EYE Hook for PCC/STP. | Providing & Fixing of Dead End Clamps with EYE Hook for PCC/STP. |
| 44 | Installation of 11KV TPMO Set. | Installation of 11KV TPMO Set. |
| 45 | Providing & Fixing of different type Clamp, nut & Bolt off size by the contractor. | Providing & Fixing of different type Clamp, nut & Bolt off size by the contractor. |
| 46 | Providing and Fixing STONE PAD 300X300X75 MM. | Providing and Fixing STONE PAD 300X300X75 MM. |
| 47 | Providing and Fixing Aluminium Tape | Providing and Fixing Aluminium Tape |
| 48 | Providing and Fixing I Bolts with Nut and Bolts as per Norms | Providing and Fixing I Bolts with Nut and Bolts as per Norms |
| 49 | Providing and Fixing Barbed wire as per Norms | Providing and Fixing Barbed wire as per Norms |
| 50 | Received Back of 25 KVA Transformer from Pit site to ESC, Mainpuri | Received Back of 25 KVA Transformer from Pit site to ESC, Mainpuri |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender