Tender for Supply And Installation Of 500 Kva Diesel Generator Set In Authorty Office At Sector-39, Noida
BOQ
| Sl. No. | Item Description |
| 1 | Supply of 500 KVA Twin Prime Duty, 415V, Kadiator Cooled, silent Type with acoustic enclosure, CPCB4+ complied dieseLgenerating set powered with suitable capacity prime duty Baudouin Engine, coupled with Leroy Somer/meccalte, H/H at 40degC, 50Hz, 415V, 1500RPM Alternator (capable of delivering true 400kW output @ 0.8 power factor), mountedon common base frame Static Excitation System, Lube Oil System, Electronic Governor including DG AMF Controller DIEF SGC420 with breaker (MCCB), A VM pads, 24 volt DC lead acid batteries, residential grade silencer with bellows, inbuilt Day oil tank, initial fill of lube oil & coolant with all other associated equipment / work complete in all respect AOR or Supply of (250X250=500) KVA Twin Prime Duty, 415V, Kadiator Cooled, silent Type with acoustic enclosure, CPCB4+ complied dieseLgenerating set powered with suitable capacity prime duty Baudouin Engine, coupled with Leroy Somer/meccalte, H/H at 40degC, 50Hz, 415V, 1500RPM Alternator (capable of delivering true 400kW output @ 0.8 power factor), mountedon common base frame Static Excitation System, Lube Oil System, Electronic Governor including DG AMF Controller DIEF SGC420 with breaker (MCCB), A VM pads, 24 volt DC lead acid batteries, residential grade silencer with bellows, inbuilt Day oil tank, initial fill of lube oil & coolant with all other associated equipment / work complete in all respect AOR |
| 2 | Supply, Installation, Testing and Commissioning of M.V. cubicle type totally enclosed free standing type, dust, damp and vermin proof D.G. Auxillary Panel made out of 14 SWG CRCA sheet complete with aluminium busbars, ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT’s, interconnections with suitable capacity aluminium leads/solid aluminium strips/ rods, interlocking, wiring powder coated and having following incoming and outgoing moulded case circuit breakers with rotary operating handle, starters, timers, etc. complete as per drawing and specification. |
| 3 | (NOTE:- All MCCB SHALL BE MOTOR DUTY) |
| 4 | INCOMING |
| 5 | 2 Nos. 160Amp FP Moulded Case Circuit Breaker. |
| 6 | 1 Nos Fixed type Automatic transfer switch 160 Amp rating in open frame with live to live transfer time <200ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS. |
| 7 | 1 No. Digital AVF Meter with inbuilt selector switch. |
| 8 | 1 Set of phase indicating lamps with Single Pole MCB. |
| 9 | 1 Set of ON / OFF indicating lamps with Single Pole MCB. |
| 10 | BUSBARS |
| 11 | 1 Set of 200Amp TPN busbar of aluminium alloy. |
| 12 | OUTGOING |
| 13 | 3 Nos. 63Amp TP moulded case circuit breaker with Starter/Delta Starter suitable for monoblock pump (15.0 HP). |
| 14 | 2 Nos. 40Amp TP moulded case circuit breaker with DOL Starter suitable for cooling pump (7.5 HP). |
| 15 | 3 Nos. 40Amp TP moulded case circuit breaker with DOL Starter suitable for cooling tower fan (7.5 HP). |
| 16 | 2 Nos. 20Amp TP moulded case circuit breaker with DOL starter suitable for Cooling Tower Fan (3.0 HP). |
| 17 | 4 Nos. 20Amp TP moulded case circuit breaker with DOL starter suitable for HSD motor (3 H.P). |
| 18 | 3 Nos. 20Amp TP moulded case circuit breaker with DOL starter suitable for LTA Pump (3 H.P. |
| 19 | 2 Nos. 20 to 40 Amp. TP moulded case circuit breaker with DOL Starter. (Spare) |
| 20 | Each DOL starter shall essentially have following. |
| 21 | 1 No. TP Power contactor. |
| 22 | 1 No. Overload relay |
| 23 | 1 No. Single phase preventor (Voltage sensing based) |
| 24 | 1 No. PLC./Manual selector switch. |
| 25 | 2 No. start/stop push buttons |
| 26 | 2 No. ON/OFF indicating lights. |
| 27 | 1 No. Trip indicating lights. |
| 28 | 1 No. Direct type ammeter. |
| 29 | 1 No.Auxillary contacts (4NO+ 4 NC). |
| 30 | 1 Set control fuses. |
| 31 | Each Star / Delta Starter shall essentially have following. |
| 32 | 3 No. TP Power contactor. |
| 33 | Timer for fully automatic operation. |
| 34 | 1 No. Overload relay |
| 35 | 1 No. Single phase preventor (Voltage sensing based) |
| 36 | 1 No. PLC./Manual selector switch. |
| 37 | 2 No. start/stop push buttons. |
| 38 | 2 No. ON/OFF indicating lights. |
| 39 | 1 No. Trip indicating lights. |
| 40 | 1 No. Direct type ammeter. |
| 41 | 1 No.Auxillary contacts (4NO+ 4 NC). |
| 42 | 1 Set control fuses. |
| 43 | D.G. Aux Panel described as above |
| 44 | 'S/L of Al. Conductor PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by the E/I Complete in all respects including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-2024, PS-20a.1-1)- 25 sq. mm 3.5 core |
| 45 | 2) 50 Sq.mm. 3½ Core |
| 46 | Supplying and making end termination with brasscompression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade asrequired. DSR-2025 11.1-1)-25 sq. mm DSR-2025 11.1.20 |
| 47 | 2)- 50 sq. mm DSR-2025 11.1.22 |
| 48 | Supplying and laying of following size DWC HDPEpipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part IIcomplete with fitting and cutting, jointing etc.direct inground (75 cm below ground level) includingexcavation and refilling the trench but excluding sandcushioning and protective covering etc., complete asrequired 1)90 mm dia (OD-90 mm & ID-76 mm nominal) DSR-Electrical-2025, 15.16.2 |
| 49 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.(but without charcoal/ coke and salt) as required. DSR-Electrical-2025,5.5 |
| 50 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. DSR-Electrical-2025,5.6 |
| 51 | Providing and laying Plinth UPERC-2025 PN.63 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
TodayNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender