Power Government Departments Closing in 13 days TDR #58244373

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation; As Per Boq - Safe Carriage Of St/Pcc Pole 11/8.5/13 Mtr. Long From Esc, Mainpuri To Pit Site Of Work

Issued by Government Departments · Mainpuri, Uttar Pradesh
Tender Value
25 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
13 days left
EMD
25000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mainpuri → Uttar Pradesh
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation; As Per Boq - Safe Carriage Of St/Pcc Pole 11/8.5/13 Mtr. Long From Esc, Mainpuri To Pit Site Of Work Including Loading And Unloading At Both Ends. Distance Approx 05 To 20 Km. , Safe Carriage Of Small Line Material From Esc, Mainpuri To Pit Site Of Work Including Loading And Unloading At Both Ends. Distance Approx05 To 20 Km. , Erection Of 11/8.5/13 Mtr. Long St/Pcc Poles & Earth Rod Complete By Excavation Of Earth 1.5 Mtr. Deep And Backfilling Properly. , Grouting Of St/Pcc Pole & Earth Rod Complete With Cement, Sand And Stone Ballast In Ratio 1:4:8 Including Cost Of Material I.E. Cement, Sand And Stone Ballast As Per Norms , Erection And Grouting Of Stay In Cc Ratio 1:4:8 Of Cement, Sand And Stone Ballast Including Cost Of Grouting Material With Nozelling And Binding Of Stay Wire (Complete Work) , Laying Of Acsr Weasel/Rabbit/Dog For Construction Of Ht/Lt Lines Including Stringing And Sagging Nozelling And Binding Conductor With Insulator. , Fixing Of 11 Kv Cross Arm 65X65x6 Mm. V Type With Clamp And Nuts And Bolts , Fixing Of 11Kv F-Clamps With Clamps, Nut & Bolts. , Fixing Of 11Kv Pin Insulator With Pin & Nut , Fixing Of 11Kv Disc Insulator With Fitting. , Fixing Of Ms T-Off Channel With Clamp Nut And Bolts Etc. And All Respective Material As Per Norms , Safe Carriage Of Single Phase 16Kva/25Kva/63Kva/100 Kva/250 Kva Transformer From Esc Mainpuri Including Loading And Unloading At Both Ends, Average Distance Approximate 05 To 20 Km.. , 16Kva 11/0.25 Kv 1-Phase Transformer , 25 Kva Alluminium Wound 11/0.4 Kv Transformer , 63 Kva 11/0.4 Kv Transformer , 100 Kva Distribution Transformer , 250 Kva Distribution Transformer , Construction Of Double Pole With All Respective Materials And Mounting Of 16Kva/25Kva/63Kva/100 Kva/250 Kva Transformer On Single Pole/Double Pole With All Respective Material (As Per Respo Schedule And Requirements) Etc. , 16Kva 11/0.25 Kv 1-Phase Transformer , 25 Kva Alluminium Wound 11/0.4 Kv Transformer , 63 Kva 11/0.4 Kv Transformer , 100 Kva Distribution Transformer , 250 Kva Distribution Transformer , Earthing Of Distribution Transformer At Water Level With Gi Strip Patti As Per Respo Mannual. , Conturction Of Plinth 2X2x1.5 Mtr. As Per Respo Norms , Construction And Installation Of Fencing Including Civil Work For 10X10x6 Feet For 250 Kva Distribution T/F. As Per Respo Norms. , Laying Of 11Kv Xlpe 3X70 Sq.Mm. Cable At Different Places Along With Cost Of Digging (As Per Norms, Brick And Sand) Under Eudd Mainpuri As Per Respo Norms. , Providing & Fixing Of Indoor/Outdoor Type Jointing Kit Suitable For 11 Kv 3X70 Sq.Mm. Xlpe Cable , Providing & Fixing Of Straight Through Jointing Kit For 3X70 Sq.Mm. Cable , Laying Of 11Kv Xlpe 3X120 Sq.Mm. Cable At Different Places Along With Cost Of Digging (As Per Norms, Brick And Sand) Under Eudd Mainpuri As Per Respo Norms. , Providing & Fixing Of Indoor/Outdoor Type Jointing Kit Suitable For 11 Kv 3X120 Sq.Mm. Xlpe Cable , Providing & Fixing Of Pipe (Hdpe 140Mm Dia) For Laying (Pipe To Be Laid By Hdd Method)(Circuit Length-170M) , Providing & Fixing Of Gi Pipe 6 Dia. , Providing & Fixing Of 4X25 Sq.Mm. Armoured Cable As Per Norms , Laying Lt Ab Cable (3X50+1X35+1X16+1X25) Sq.Mm. With 5% Sag , Laying Lt Abc Cable (3X120+1X35+1X16) Sq.Mm. , Laying Cable (3.5X700) Sq.Mm. For Connection , Providing And Fixing Gaurding With Angle, Clamp, Nut&Bolts. With Gi Wire 6/8/10 Swg. (32 Span) , Fixing Of Single Phase / Three Phase Distribution Box With Clamp As Per Norms. , Fixing Of 11 Kv Vcb As Per Norms , Fixing Of Ct / Pt Pole Mounting Unit 15/5 A , Fixing Of Ct / Pt Pole Mounting Unit 20/05 A , Providing & Fixing Of Suspension Clamps & I Hook For Pcc/Stp. , Providing & Fixing Of Dead End Clamps With Eye Hook For Pcc/Stp. , Providing & Fixing Of Pearcing Connector (1X16+3X50)Sq.Mm. Abc. , Providing & Fixing Of Different Type Clamp, Nut & Bolt Off Size By The Contractor. , Providing And Fixing Tailless Unit Protection Cubical Pannel 500 A, 650 V For 250 Kva Dtr. As Per Norms , Providing And Fixing Lt Protection Dtr For 7 Nos. 100 Kva T/F With Box And All Respective Material As Per Norms. , Supply And Erection Lt Incomming Pannel With 4 Core Lt Mcb Box, Metering Equipment & Fixing Arrangment As Per Norms , Providing And Fixing Stone Pad 300X300x75 Mm. , Providing And Fixing Danger Board With Clamp Nut And Bolts , Providing And Fixing Barbed Wire As Per Norms , Providing And Fixing I Bolts With Nut And Bolts As Per Norms , Supply Of Red Oxide Paint And Painting Of Stp Pole Properly , Supply Of Alluminium Paint And Painting Of Stp Pole Properly , Received Back Of 25 Kva Transformer From Pit Site To Esc, Mainpuri , Received Back Of Iron Scrap From Pit Site To Esc, Mainpuri , Received Back Of Acsr Weasel Scrap From Pit Site Of Work To Esc, Mainpuri

BOQ

Sl. No. Item TitleItem Description
1Safe carriage of ST/PCC Pole 11/8.5/13 Mtr. Long from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx 05 TO 20 KM.Safe carriage of ST/PCC Pole 11/8.5/13 Mtr. Long from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx 05 TO 20 KM.
2Safe carriage of small line material from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx05 TO 20 KM.Safe carriage of small line material from ESC, Mainpuri to Pit site of work including loading and unloading at both ends. Distance Approx05 TO 20 KM.
3Erection of 11/8.5/13 Mtr. Long ST/PCC Poles & Earth Rod Complete by excavation of earth 1.5 mtr. deep and backfilling properly.Erection of 11/8.5/13 Mtr. Long ST/PCC Poles & Earth Rod Complete by excavation of earth 1.5 mtr. deep and backfilling properly.
4Grouting of ST/PCC Pole & Earth Rod Complete with Cement, Sand and Stone Ballast in ratio 1:4:8 including cost of material i.e. Cement, Sand and Stone Ballast as per NormsGrouting of ST/PCC Pole & Earth Rod Complete with Cement, Sand and Stone Ballast in ratio 1:4:8 including cost of material i.e. Cement, Sand and Stone Ballast as per Norms
5Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
6Laying of ACSR Weasel/Rabbit/Dog for construction of HT/LT Lines including stringing and sagging nozelling and binding conductor with insulator.Laying of ACSR Weasel/Rabbit/Dog for construction of HT/LT Lines including stringing and sagging nozelling and binding conductor with insulator.
7Fixing of 11 KV CROSS ARM 65X65X6 mm. V TYPE WITH CLAMP and Nuts and BoltsFixing of 11 KV CROSS ARM 65X65X6 mm. V TYPE WITH CLAMP and Nuts and Bolts
8Fixing of 11KV F-Clamps with Clamps, Nut & Bolts.Fixing of 11KV F-Clamps with Clamps, Nut & Bolts.
9Fixing of 11KV Pin Insulator with Pin & NUTFixing of 11KV Pin Insulator with Pin & NUT
10Fixing of 11KV Disc insulator with fitting.Fixing of 11KV Disc insulator with fitting.
11Fixing of MS T-Off Channel with Clamp Nut and Bolts etc. and all respective material as per NormsFixing of MS T-Off Channel with Clamp Nut and Bolts etc. and all respective material as per Norms
12Safe carriage of Single Phase 16KVA/25KVA/63KVA/100 KVA/250 KVA transformer from ESC Mainpuri including loading and unloading at both ends, average distance approximate 05 TO 20 KM..Safe carriage of Single Phase 16KVA/25KVA/63KVA/100 KVA/250 KVA transformer from ESC Mainpuri including loading and unloading at both ends, average distance approximate 05 TO 20 KM..
1316KVA 11/0.25 KV 1-PHASE Transformer16KVA 11/0.25 KV 1-PHASE Transformer
1425 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER25 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER
1563 KVA 11/0.4 KV TRANSFORMER63 KVA 11/0.4 KV TRANSFORMER
16100 KVA Distribution Transformer100 KVA Distribution Transformer
17250 KVA Distribution Transformer250 KVA Distribution Transformer
18Construction of Double pole with all respective materials and Mounting of 16KVA/25KVA/63KVA/100 KVA/250 KVA Transformer on Single Pole/Double Pole with all respective material (As per RESPO Schedule and requirements) etc.Construction of Double pole with all respective materials and Mounting of 16KVA/25KVA/63KVA/100 KVA/250 KVA Transformer on Single Pole/Double Pole with all respective material (As per RESPO Schedule and requirements) etc.
1916KVA 11/0.25 KV 1-PHASE Transformer16KVA 11/0.25 KV 1-PHASE Transformer
2025 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER25 KVA ALLUMINIUM WOUND 11/0.4 KV TRANSFORMER
2163 KVA 11/0.4 KV TRANSFORMER63 KVA 11/0.4 KV TRANSFORMER
22100 KVA Distribution Transformer100 KVA Distribution Transformer
23250 KVA Distribution Transformer250 KVA Distribution Transformer
24Earthing of Distribution Transformer at water level with GI Strip Patti as per Respo Mannual.Earthing of Distribution Transformer at water level with GI Strip Patti as per Respo Mannual.
25Conturction of Plinth 2x2x1.5 Mtr. as per Respo NormsConturction of Plinth 2x2x1.5 Mtr. as per Respo Norms
26Construction and Installation of Fencing Including Civil work for 10x10x6 Feet for 250 KVA Distribution T/F. as per Respo Norms.Construction and Installation of Fencing Including Civil work for 10x10x6 Feet for 250 KVA Distribution T/F. as per Respo Norms.
27Laying of 11KV XLPE 3x70 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms.Laying of 11KV XLPE 3x70 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms.
28Providing & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X70 SQ.MM. XLPE CABLEProviding & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X70 SQ.MM. XLPE CABLE
29Providing & Fixing OF STRAIGHT THROUGH JOINTING KIT FOR 3X70 Sq.Mm. CableProviding & Fixing OF STRAIGHT THROUGH JOINTING KIT FOR 3X70 Sq.Mm. Cable
30Laying of 11KV XLPE 3x120 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms.Laying of 11KV XLPE 3x120 sq.mm. Cable At different places along with cost of digging (As per Norms, Brick and Sand) under EUDD mainpuri as per Respo Norms.
31Providing & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X120 SQ.MM. XLPE CABLEProviding & Fixing OF INDOOR/OUTDOOR TYPE JOINTING KIT SUITABLE FOR 11 KV 3X120 SQ.MM. XLPE CABLE
32Providing & Fixing of PIPE (HDPE 140MM DIA) FOR LAYING (PIPE TO BE LAID BY HDD METHOD)(CIRCUIT LENGTH-170M)Providing & Fixing of PIPE (HDPE 140MM DIA) FOR LAYING (PIPE TO BE LAID BY HDD METHOD)(CIRCUIT LENGTH-170M)
33Providing & Fixing of GI Pipe 6\\" dia.Providing & Fixing of GI Pipe 6\\" dia.
34Providing & Fixing of 4x25 Sq.mm. Armoured Cable as per NormsProviding & Fixing of 4x25 Sq.mm. Armoured Cable as per Norms
35Laying LT AB CABLE (3X50+1X35+1X16+1X25) SQ.MM. WITH 5% SAGLaying LT AB CABLE (3X50+1X35+1X16+1X25) SQ.MM. WITH 5% SAG
36Laying LT ABC CABLE (3X120+1X35+1X16) SQ.MM.Laying LT ABC CABLE (3X120+1X35+1X16) SQ.MM.
37Laying CABLE (3.5X700) SQ.MM. For connectionLaying CABLE (3.5X700) SQ.MM. For connection
38Providing and Fixing Gaurding with Angle, Clamp, Nut&Bolts. With GI wire 6/8/10 SWG. (32 span)Providing and Fixing Gaurding with Angle, Clamp, Nut&Bolts. With GI wire 6/8/10 SWG. (32 span)
39Fixing of single phase / Three Phase Distribution Box with Clamp as per Norms.Fixing of single phase / Three Phase Distribution Box with Clamp as per Norms.
40Fixing of 11 KV VCB AS PER NORMSFixing of 11 KV VCB AS PER NORMS
41Fixing of CT / PT POLE MOUNTING UNIT 15/5 AFixing of CT / PT POLE MOUNTING UNIT 15/5 A
42Fixing of CT / PT POLE MOUNTING UNIT 20/05 AFixing of CT / PT POLE MOUNTING UNIT 20/05 A
43Providing & Fixing of Suspension Clamps & I Hook for PCC/STP.Providing & Fixing of Suspension Clamps & I Hook for PCC/STP.
44Providing & Fixing of Dead End Clamps with EYE Hook for PCC/STP.Providing & Fixing of Dead End Clamps with EYE Hook for PCC/STP.
45Providing & Fixing of Pearcing Connector (1x16+3x50)sq.mm. ABC.Providing & Fixing of Pearcing Connector (1x16+3x50)sq.mm. ABC.
46Providing & Fixing of different type Clamp, nut & Bolt off size by the contractor.Providing & Fixing of different type Clamp, nut & Bolt off size by the contractor.
47Providing and Fixing Tailless Unit Protection Cubical Pannel 500 A, 650 V for 250 KVA DTR. As per NormsProviding and Fixing Tailless Unit Protection Cubical Pannel 500 A, 650 V for 250 KVA DTR. As per Norms
48Providing and Fixing LT Protection DTR for 7 Nos. 100 KVA T/F with Box and all respective material as per Norms.Providing and Fixing LT Protection DTR for 7 Nos. 100 KVA T/F with Box and all respective material as per Norms.
49Supply and Erection LT incomming Pannel with 4 Core LT MCB Box, metering Equipment & fixing arrangment As per NormsSupply and Erection LT incomming Pannel with 4 Core LT MCB Box, metering Equipment & fixing arrangment As per Norms
50Providing and Fixing STONE PAD 300X300X75 MM.Providing and Fixing STONE PAD 300X300X75 MM.
51Providing and Fixing Danger Board with Clamp NUT AND BOLTSProviding and Fixing Danger Board with Clamp NUT AND BOLTS
52Providing and Fixing Barbed wire as per NormsProviding and Fixing Barbed wire as per Norms
53Providing and Fixing I Bolts with Nut and Bolts as per NormsProviding and Fixing I Bolts with Nut and Bolts as per Norms
54supply of RED Oxide Paint and painting of STP POLE properlysupply of RED Oxide Paint and painting of STP POLE properly
55supply of Alluminium Paint and painting of STP POLE properlysupply of Alluminium Paint and painting of STP POLE properly
56Received Back of 25 KVA Transformer from Pit site to ESC, MainpuriReceived Back of 25 KVA Transformer from Pit site to ESC, Mainpuri
57Received Back of IRON SCRAP from Pit site to ESC, MainpuriReceived Back of IRON SCRAP from Pit site to ESC, Mainpuri
58Received Back of ACSR WEASEL SCRAP from Pit site of work to ESC, MainpuriReceived Back of ACSR WEASEL SCRAP from Pit site of work to ESC, Mainpuri

AI Tender Summary

OUR REF NO 58244373
AUTHORITY Government Departments
TENDER VALUE 25 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Uttar Pradesh Power Corporation Limited
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation; As Per Boq - Safe Carriage Of St/Pcc Pole 11/8.5/13 Mtr. Long From Esc, Mainpuri To Pit Site Of Work Including Loading And Unloading At Both Ends. Distance Approx 05 To 20 Km. , Safe Carriage Of Small Line Material From Esc, Mainpuri To Pit Site Of Work Including Loading And Unloading At Both Ends. Distance Approx05 To 20 Km. , Erection Of 11/8.5/13 Mtr. Long St/Pcc Poles & Earth Rod Complete By Excavation Of Earth 1.5 Mtr. Deep And Backfilling Properly. , Grouting Of St/Pcc Pole & Earth Rod Complete With Cement, Sand And Stone Ballast In Ratio 1:4:8 Including Cost Of Material I.E. Cement, Sand And Stone Ballast As Per Norms , Erection And Grouting Of Stay In Cc Ratio 1:4:8 Of Cement, Sand And Stone Ballast Including Cost Of Grouting Material With Nozelling And Binding Of Stay Wire (Complete Work) , Laying Of Acsr Weasel/Rabbit/Dog For Construction Of Ht/Lt Lines Including Stringing And Sagging Nozelling And Binding Conductor With Insulator. , Fixing Of 11 Kv Cross Arm 65X65x6 Mm. V Type With Clamp And Nuts And Bolts , Fixing Of 11Kv F-Clamps With Clamps, Nut & Bolts. , Fixing Of 11Kv Pin Insulator With Pin & Nut , Fixing Of 11Kv Disc Insulator With Fitting. , Fixing Of Ms T-Off Channel With Clamp Nut And Bolts Etc. And All Respective Material As Per Norms , Safe Carriage Of Single Phase 16Kva/25Kva/63Kva/100 Kva/250 Kva Transformer From Esc Mainpuri Including Loading And Unloading At Both Ends, Average Distance Approximate 05 To 20 Km.. , 16Kva 11/0.25 Kv 1-Phase Transformer , 25 Kva Alluminium Wound 11/0.4 Kv Transformer , 63 Kva 11/0.4 Kv Transformer , 100 Kva Distribution Transformer , 250 Kva Distribution Transformer , Construction Of Double Pole With All Respective Materials And Mounting Of 16Kva/25Kva/63Kva/100 Kva/250 Kva Transformer On Single Pole/Double Pole With All Respective Material (As Per Respo Schedule And Requirements) Etc. , 16Kva 11/0.25 Kv 1-Phase Transformer , 25 Kva Alluminium Wound 11/0.4 Kv Transformer , 63 Kva 11/0.4 Kv Transformer , 100 Kva Distribution Transformer , 250 Kva Distribution Transformer , Earthing Of Distribution Transformer At Water Level With Gi Strip Patti As Per Respo Mannual. , Conturction Of Plinth 2X2x1.5 Mtr. As Per Respo Norms , Construction And Installation Of Fencing Including Civil Work For 10X10x6 Feet For 250 Kva Distribution T/F. As Per Respo Norms. , Laying Of 11Kv Xlpe 3X70 Sq.Mm. Cable At Different Places Along With Cost Of Digging (As Per Norms, Brick And Sand) Under Eudd Mainpuri As Per Respo Norms. , Providing & Fixing Of Indoor/Outdoor Type Jointing Kit Suitable For 11 Kv 3X70 Sq.Mm. Xlpe Cable , Providing & Fixing Of Straight Through Jointing Kit For 3X70 Sq.Mm. Cable , Laying Of 11Kv Xlpe 3X120 Sq.Mm. Cable At Different Places Along With Cost Of Digging (As Per Norms, Brick And Sand) Under Eudd Mainpuri As Per Respo Norms. , Providing & Fixing Of Indoor/Outdoor Type Jointing Kit Suitable For 11 Kv 3X120 Sq.Mm. Xlpe Cable , Providing & Fixing Of Pipe (Hdpe 140Mm Dia) For Laying (Pipe To Be Laid By Hdd Method)(Circuit Length-170M) , Providing & Fixing Of Gi Pipe 6 Dia. , Providing & Fixing Of 4X25 Sq.Mm. Armoured Cable As Per Norms , Laying Lt Ab Cable (3X50+1X35+1X16+1X25) Sq.Mm. With 5% Sag , Laying Lt Abc Cable (3X120+1X35+1X16) Sq.Mm. , Laying Cable (3.5X700) Sq.Mm. For Connection , Providing And Fixing Gaurding With Angle, Clamp, Nut&Bolts. With Gi Wire 6/8/10 Swg. (32 Span) , Fixing Of Single Phase / Three Phase Distribution Box With Clamp As Per Norms. , Fixing Of 11 Kv Vcb As Per Norms , Fixing Of Ct / Pt Pole Mounting Unit 15/5 A , Fixing Of Ct / Pt Pole Mounting Unit 20/05 A , Providing & Fixing Of Suspension Clamps & I Hook For Pcc/Stp. , Providing & Fixing Of Dead End Clamps With Eye Hook For Pcc/Stp. , Providing & Fixing Of Pearcing Connector (1X16+3X50)Sq.Mm. Abc. , Providing & Fixing Of Different Type Clamp, Nut & Bolt Off Size By The Contractor. , Providing And Fixing Tailless Unit Protection Cubical Pannel 500 A, 650 V For 250 Kva Dtr. As Per Norms , Providing And Fixing Lt Protection Dtr For 7 Nos. 100 Kva T/F With Box And All Respective Material As Per Norms. , Supply And Erection Lt Incomming Pannel With 4 Core Lt Mcb Box, Metering Equipment & Fixing Arrangment As Per Norms , Providing And Fixing Stone Pad 300X300x75 Mm. , Providing And Fixing Danger Board With Clamp Nut And Bolts , Providing And Fixing Barbed Wire As Per Norms , Providing And Fixing I Bolts With Nut And Bolts As Per Norms , Supply Of Red Oxide Paint And Painting Of Stp Pole Properly , Supply Of Alluminium Paint And Painting Of Stp Pole Properly , Received Back Of 25 Kva Transformer From Pit Site To Esc, Mainpuri , Received Back Of Iron Scrap From Pit Site To Esc, Mainpuri , Received Back Of Acsr Weasel Scrap From Pit Site Of Work To Esc, Mainpuri
Basic Detail
Tender No GEM/2026/B/8210385
Bidding Type Tender
Location
City Mainpuri
State Uttar Pradesh
Key Dates
Publish Date 28 Oct 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 25 Lakhs
Tender Fee Ref. Documents
EMD 25000
Exemption Not Available
Document List
fe1ebbf9-8c0d-4537-ac52-bc8a8ab2743e.pdf
1793173922.xlsx
1793173939.pdf
1793173946.pdf
1793173953.pdf
1793173958.pdf
ATCEUDD_1d048200-ece3-4af8-87351793174298946_EDCMAINPURIBUYCON.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

fe1ebbf9-8c0d-4537-ac52-bc8a8ab2743e.pdf

xlsx

1793173922.xlsx

pdf

1793173939.pdf

pdf

1793173946.pdf

pdf

1793173953.pdf

pdf

1793173958.pdf

pdf

ATCEUDD_1d048200-ece3-4af8-87351793174298946_EDCMAINPURIBUYCON.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender