Water Resources and Irrigation Government Departments Closing in 6 days TDR #58242957

Tender For Execution, Energisation And Drilling Works Of Gundilo_Iv Tw Under Dharmasala Block In Jajpur District.

Issued by Government Departments · Jajapur, Odisha
Tender Value
26.36 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
6 days left
EMD
26361
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jajapur → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Execution, Energisation And Drilling Works Of Gundilo_Iv Tw Under Dharmasala Block In Jajpur District.

BOQ

Name of Work:- Execution, Energisation and Drilling Works of Gundilo_IV TW Under Dharmasala Block in Jajpur District.
Sl. No. Item Description
1Schdule -A
2Earthwork in excavation of foundation in hard soil for stiff clay , stiff black cotton, hard red earth, shales, moorum ordinary gravels, including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. (Mechanical 60% & Manual 40%)
3Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge.
4Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge.
5Brick work with Fly ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
6Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) in superstructure per cum etc. complete as per the Engineer-incharge.
712mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
8R.C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
92.5 cm A.S. Flooring with C.C. (1:2:4) using 12mm size black hard granite crusher broken chips of approve quality for approve quorry including water and curring with cost taxes royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
10Rigid smooths centering and shuttering for RCC works including false work and dismentgalling then after casting including cot os materials complete.(a) RCC walls and fins including attached pillasters
11b) Chajja/Roof slab
12c) Lintel
13Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Still Bar (FE 415/ FE 500)
14Filling the foundation and plinth with the excavated material as directed by the Engineer-incharge.
15Distempering two coats to walls with Distemper of approved shade on new work to give an even shade exculding cost of Distemper. Per 1 Sqm. complete as per the direction of Engineer – in Charge
16Finishing wall with water proofing cement paint of approved shade two coats to NEW work to give an even shade including cost of cement paints. etc. complete as per the direction of Engineer – in Charge.
17Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.
18MS Pannel Door double leafed with MS frame overall size including frame of height 1.2mt x 1.98mt. width for door and shutter of 20 gauge CR sheet pannel as per approved size & specification etc. complete including cost of all materials fitting and fixing the door etc. complete as per the direction of the Engineer-incharge.
19Cost, Supplying of ISI marked 200 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 for water supply as per IS 4984/2016 in the following Nominal diameter, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST etc. complete as per the direction of the Engineer-incharge.
20Fitting and Fixing 200mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 Pipe including jointing the pipe including fitting and fixing of required no. of Riser Tee for outlet and Shaddle and nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
21Cost, Supplying of ISI marked 160 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 for water supply as per IS 4984/2016 in the following Nominal diameter, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST etc. complete as per the direction of the Engineer-incharge.
22Fitting and Fixing 160 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 Pipe including jointing the pipe including fitting and fixing of required no. of Riser Tee for outlet and Shaddle and nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
237.5 HP/5.62 KW Energy efficiency Submersible pumpset of total head 25 mtr having 900 LPM discharge of reputed brand with BEE 3 Star rated energy efficiency suitable for 200 mm dia tube well as per IS specification with 2 pair U-Clamp & 30 mtr of 4.00 sqmm
24Labour charges for installation of Submersible Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding and construction of supporting pillar etc. complete as per the direction of the Engineer-incharge.
25100 mm Ø nominal bore G.I. pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark.
26100mm dia G.I Bend (Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST
27100mm dia G.I.Flange (Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST
28100mm dia G.I. Nipple (Medium Duty) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST
29100mm dia G.I.Socket (Medium Duty) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST
30Cost, supplying of M.S T/W Clamp (Pair) 100mm dia with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST
31100mm dia C.I.Sluice Valve Flanged type PN-1.0 as per (IS-14846-2000 Standard) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST (As per S/R 2022)
3225 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark.
33Cost of 160mm x 160mm x 160mm HDPE Equal Tee
34Cost of 200mm x 200mm x 160 mm dia. HDPE Tee
35Cost of 160 mm dia HDPE End cap
36Cost of 160 mm dia HDPE tail paice
37Cost of 160 mm dia HDPE Flange
38Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST
39Cost of 150mm dia C.I. Butter Fly Valve BS:5155/15: Kirloskar or equivalent make 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed including all cost, conveyance, cess etc complete but excluding cost of GST (As per S/R 2022)
40Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp
4163 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark.
423 x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming.
434.0 mm2 Submerssible (3 Core) Flat Cable ISI mark of reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST
44Cost of Sly wrench 10''- 1 nos,Screw driver-10''-01 nos, star Screw driver-01 nos, Cutting Pliers- 01 nos, hand gloves- 01 pairs, 4 amp fuse-20 gm, Black tap- 5 packet, Lock and key - 03 nos etc.
45Schedule-B
46Construction of 3 phase 11 KV HT line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm AAA Conductor average span 40mtr , 11 KV \\"V\\" Cross arm required No.of 11 KV T & C Disc. polymer Insulators in tension point & 11 KV Pin Polymer insulators, Couping & Padding of Poles with all G.I.Channels. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc if required including cost of all materials, labour, transportation, erection & commissioning, earthing with chamber etc complete.
47Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation with 5mtrx3mtrx1.5mtr height mesonary toe wall /G.I. Flat fencing boundary wall with Flat with Polymer insulator ,L.T Dist Box with MCCB , Aluminim bus bar of single bay with kitkat fuse , sand filling and metal spearding with M.S.Grill gate ,all Channel matrials should be G.I , 7 Nos earthing with chamber with 3mtr G.I pipe of 40mm dia with connecting of 25mmx 5mm G.I flat to all earthing including 25KVA BIS Leble-II Star rated Transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm G.I.Channel, Transformer belting on 2.80 M long 50mm X 50mm X 5 mm G.I.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75mm X 40mm X 6 mm G.I.Channel and supported by 1.0 M long 50 X 50 X 5 mm G.I.Angle, with 3 No. 11 KV Lightening Arrestors and Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets as per TPNODL specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning, SITC and Erection of GI fencing/ brick masonary boundary wall 16 running metre with grill gate etc. complete but excluding cost of 6% supervision & inspection chargesas per specification of TPNODL etc complete.
48Electrical Earthing including all materials as per the direction of the Engineer-incharge.
494 KVR Power shunt capacitor
5011 KV Line 90 digree cut point
51Interposing pole 9 mtr 300kg PSC pole
52Schedule-C
53Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer in charge including use of own Rigs with its accessories, tools and plants and all consumables (like coir rope, cotton waste and bentonite powder etc. complete) etc. for lowering of finished bore suitable for lowering (minimum 400 mm dia.) of 200mm dia GI/PVC Pipe for housing fitted with sockets and with or without well screen as per the necessity for the soft medium, hard and boulder formations (. GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion ) including lower and withdrawing of casing pipes after drilling 200mm to 450mm dia in over burden portion.
54For Drilling of 200 (8”) dia pipe
55From 0 mtr. to 100th meters
56200mm Ø SCHEDULE 80 casing pipe (As per EPM Rate order no.4415 dated 25.10.2024)
57200mm Ø SCHEDULE 80 casing pipe threading charges
588\\" PVC bail plug
598\\" PVC threaded end cap PN-10
60200mm x 12\\" long PVC shot piece
61Labour charges for cutting Transverse slot on 200 mm dia pvc pipe with slot size 1.5 mm as per specification
62Supply of all Labour & T&P for lowering the following sizes of PVC Pipes with or without slotted pipes as per the necessity from ground level & fitted & fixed up in perfectly verticaly position inlcuding cutting & threading pipe and slotted pipe and fixing all jointing materials etc. complete. and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fitting & joining materials.
63Cost of supply of washed and screened gravel PE-6 size river shingels or bajri
64Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58242957
AUTHORITY Government Departments
TENDER VALUE 26.36 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Orissa Lift Irrigation Corporation Limited
Work Description Tender for Execution, Energisation And Drilling Works Of Gundilo_Iv Tw Under Dharmasala Block In Jajpur District.
Basic Detail
Tender No OLIC_03_26_27
Bidding Type Tender
Location
City Jajapur
State Odisha
Key Dates
Publish Date 28 Oct 2026
Submission Date 04 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 26.36 Lakhs
Tender Fee 7080
EMD 26361
Exemption Available
Document List
BOQ_616157.xls
DTCN.pdf
e46ba64f-e9e8-47ac-afa2-84313a14c797.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_616157.xls

pdf

DTCN.pdf

html

e46ba64f-e9e8-47ac-afa2-84313a14c797.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender