Housing Urban and Rular Development Government Departments Closing in 12 days TDR #58242357

Tender For Up-Gradation Of Existing Sewage Treatment Plant In Police Lines, Fatehabad.

Issued by Government Departments · Fatehabad, Haryana
Tender Value
1.22 Crore
Estimated cost
Bid Submission
10 Nov 2026
12 days left
EMD
2.46 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Fatehabad → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Up-Gradation Of Existing Sewage Treatment Plant In Police Lines, Fatehabad.

BOQ

Name of Work:- Up-gradation of Existing Sewage Treatment Plant in Police Lines, Fatehabad.
Sl. No. Item Description
1[10.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. [Through Rate]
2[10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]
3[10.67.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm [Through Rate]
4[10.77]Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. [Through Rate]
5[10.8]Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4 [Through Rate]
6[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate]
7[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
8[11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate]
9[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate]
10[11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate]
11[11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. [Through Rate]
12[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate]
13[12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate]
14[13.21.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter [Through Rate]
15[13.24.1]Providing and fixing glazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of Gasket / beading shall be paid as per respective item) 1. Float glass panes of 5.5mm thickness [Through Rate]
16[13.42.3]Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 3. G.I. pipes [Through Rate]
17[20.11.2]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 2. 100 mm i/d [Through Rate]
18[20.71.2]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 2. 56\\" (1400mm) [Through Rate]
19[22.1.1]Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1. White vitreous chinaware Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps [Through Rate]
20[22.103.2]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2. 20 mm nominal bore [Through Rate]
21[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]
22[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate]
23[22.157.1]Providing and laying SandS C.I. Standard specials such as tees, bends, collars tapers and caps etc, suitable for flanged jointing as per IS : 1538 : 1. Up to 300 mm dia [Through Rate]
24[22.160.1]Providing and laying SandS Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 1. 100 mm dia Ductile Iron Class K-7 pipes [Through Rate]
25[22.166.1.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
26[22.179.1.1]Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 1.1. Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
27[22.180.1.1]Extra for depth beyond 45 cm of brick masonry chamber : 1.1. For 455x610 mm size With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
28[22.182]Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet and over flow pipes. The base support i/c fittings and fixtures for tank shall be paid separately. [Through Rate]
29[22.2.1]Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 1. White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer [Through Rate]
30[22.22.1]Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests [Through Rate]
31[22.222.1.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.2. Single Socket Type A 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
32[22.222.1.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.3. Single Socket Type A 90mm o/d SWR UPVC pipe lines laid complete [Through Rate]
33[22.80.2.1]Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 2.1. 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 [Through Rate]
34[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate]
35[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]
36[22.9.1]Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: 1. White glazed fire clay kitchen sink of size 600x450x 250 mm [Through Rate]
37[23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate]
38[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
39[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate]
40[23.23.1.3]MISCELLANEOUS 1.3. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 25 mm dia [Through Rate]
41[23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm [Through Rate]
42[23.23.7.4]MISCELLANEOUS 7.4. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 600 X 50 X 2 mm [Through Rate]
43[23.28.11.2]Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 2. Powder coated die cast /Extruded aluminum Body (Thickness >= 1.20 mm) 24-26 Watt [Rate]
44[23.28.14.13]Supplying, installation, Testing and Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80 , under voltage and over voltage protection,EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 13. 72 watt [Rate]
45[23.28.17.4]Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-10, CRI )80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. 150 watt [Rate]
46[23.28.5.4]Supplying, installation, Testing and Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. `complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. Powder coated die cast with Aluminium Reflector 18 watt [Rate]
47[23.28.8.10]Supplying, installation, Testing and Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 10. CRCA Sheet Body (Thickness >= 0.50 mm) 36 watt [Rate]
48[23.4.1.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A [Through Rate]
49[23.4.4.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A [Through Rate]
50[23.4.5.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A [Through Rate]
51[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
52[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
53[23.8.1.12]FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. [Through Rate]
54[23.8.1.5]FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type [Through Rate]
55[23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate]
56[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate]
57[23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate]
58[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate]
59[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate]
60[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
61[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate]
62[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
63[24.13.20]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 20. 16 Sq mm 2core (Arm.) [Through Rate]
64[24.4.16]STREET LIGHT 16. Supply and erection of weather proof M.S. box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement , housed in wall , including the cost of 1 no. 16 amp. 415 volts SP MCB and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board/10 mm Bakellite sheet in the M.S. box including painting and necessary connections . [Through Rate]
65[24.4.2.3]STREET LIGHT 2.3. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 120 cm long, with 30 cm high suitable size pole cap [Through Rate]
66[24.4.8.5]STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm [Through Rate]
67[24.5.2.2]MISCELLANEOUS ITEMS 2.2. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 50/40 mm outer dia/ inner dia [Through Rate]
68[30.91]Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia up to 300mm [Through Rate]
69[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
70[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]
71[4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]
72[5.26]Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. [Through Rate]
73[5.27]Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. [Through Rate]
74[5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate]
75[6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) [Through Rate]
76[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]
77[6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. [Through Rate]
78[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]
79[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]
80[6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) [Through Rate]
81[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate]
82[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
83[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
84[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]
85[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate]
86[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
87[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
88[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]
89[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate]
90[9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate]
91Manpower deputed at site on 8 hours shift basis.
92Test report from NABL, HPCB approved laboratory
93Consumables like chlorine, oil and grease, EM solution for routine maintenance (1 Lot x 12 Months).
94Rate for Recovery of Old Bricks.
95Rate for Recovery of Old Brick Bats.
96Rate for Recovery of Old Steel.
97SUPPLY,INSTALLATION,TESTING and COMMISSIOING OF SUBMERSIBLE RAW SEWAGE TRANSFER PUMPS, C.I IMPELLER and C.I BODY,CONNECTED TO INBUILT MOTOR(WITH MECHNICAL SEAL) SUITABLE FOR 400/440 VOLTS, 3 PHASE 50 CYCLES A.C SUPPLY. PUMPS SUITABLE TO HANDLE SOLIDS UPTO 50MM SIZE WITH C.I BODY,C.I IMPILLER WITH COMPLETED IN ALL RESPECT MEACHNICAL SEALCAPACITY/FLOW RATE:-25M³/hrHEAD:-8-10 MTR1SET:-2NO’S PUMPS(1W plus 1S)R.P.M:-2900M.O.C:- C,I CASING/C.I IMPELLERMAKE:-WILO/KIRLOSKAR/KSB
98SUPPLY, INSTALLATION, TESTING and COMMISSIOING OF BELT TYPE OIL SKIMMER FOR REMOVAL OF OIL and GREASE PRESENT IN EFFLUENT FROM KITCHEN AREA and RESTAURANT AREA. OIL REAMOVAL CAPACITY: 0-50 LPH MOC OF OIL SKIMMER: MSEP, MOTOR HP-0.5 HP COMPLETED IN ALL RESPECT MAKE:- GREEN FORCE ENVIRO/PREMIER OIL SKIMMER/KSR ENGG./VAG/JASH/MECHANIOTECH/W2P
99SUPPLY, INSTALLATION, TESTING and COMMISSIOING OF TWIN LOBE ROTARY AIR BLOWERS FOR EQUALIZATION TANK,MBBR -1 and 2 and SLUDGE HOLDING TANK CAPABLE OF DELIVERING 400M³/Hr OF FREE AIR AT 0.4KGCM² DRIVEN THROUGH “V” BELT OR DIRECTLY COUPLED THROUGH FLEXIBLE COUPLING TO A TEFC MOTOR OF SUITABLE HP FOR 415 ±10% VOLTS ,3 PHASE,50 CYCLES AC SUPPLY COMPLETED IN ALL RESPECT MAKE:-KAY/AKASH/EVERST/USHA/SWAM
100SUPPLY, INSTALLATION, TESTING and COMMISSIONING OF COARSE BUBBLE DIFFUSERS OF DISK TYPE EPDM MATERIAL FOR EQUALIZATION TANK.COMPLETED IN ALL RESPECT MAKE:-W2P/GREEN FORCE ENVIRO/SHRI RAM ENVIROTECH/BHARAT/IFU/GREENAGER
101SUPPLY, INSTALLATION, TESTING and COMMISSIONING OF FINE BUBBLE MEMBRANE DIFFUSERS DISK TYPE OFEPDM MATERIAL FOR MBBR TANKS WITH AERATION GRID. COMPLETED IN ALL RESPECT MAKE:-BIO FLOW/GREEN FORCE ENVIRO/SHRI RAM ENVIROTECH/W2P/IFU/GREENAGER
102SUPPLY, INSTALLATION,TESTING and COMMISSIOING OF HIGH SURFACE AREA BIO MEDIA OF TRANSPARENT WHITE COLOUR MADE OF PP HAVING SURFACE AREA SUITABLE TO BE USED IN MBBR REACTOR. SPECIFIC GRAVITY 0.96 PLUS/-0.01 BUILD DENSITY :145PLUS/ -5KG/M3 COMPLETED IN ALL RESPECT MAKE:-BIO FLOW/GREEN FORCE ENVIRO/SHRI RAM ENVIROTECH/W2P/JASH/MECHANIOTECH/AQUATECH
103SUPPLY, INSTALLATION,TESTING and COMMISSIOING OF TUBE DECK MEDIA AS PER SIZE OF TUBE SETTLER MADE OF PP HAVING SURFACE AREA SUITABLE TO BE USED IN TUBE SETTLER.COMPLETED IN ALL RESPECT. MAKE:-BIO FLOW/GREEN FORCE ENVIRO/SHRI RAM ENVIROTECH/W2P/GREENAGER/BIOPLASTO
104SUPPLY,INSTALLATION,TESTING and COMMISSIOING OF HORIZONTAL CENTRIFUGAL FILTER FEED PUMPS CI HEAD and BASE,C.I IMPELLER ALONG WITH MOTOR,PRESSURE GAUGE ,NRV ON DELIVERY LINE and MECHNICAL SEAL. THE PUMP SHALL BE SUITABLE FOR 400/415 VOLTS, 3 PHASE 50 CYCLES A.C SUPPLY.(1W plus 1 S.) COMPLETED IN ALL RESPECT CAPACITY/FLOW RATE:-25M³/hrHEAD:-30-35 MTR1SET:-2NO’S PUMPS(1W plus 1S)R.P.M:-2900M.O.C:- C,I CASING/C.I OR S.S IMPELLERMAKE:-WILO/KIRLOSKAR/KSB/OSWAL/
105PROVIDING,FIXING, TESTING and COMMISIONING OF VERTICAL SELF SUPPORTING PRESSURE SAND FILTER COMPLETE WITH MEDIA, PRESSURE GAUGES AT INLET and OUTLET WITH MANUAL BUTTERFLY VALVES. COMPLETED IN ALL RESPECT CAPACITY/FLOW RATE:-25M³/hrFILTRATION RATE:-APPROX (15M³/Hr/M²)FILTER DIMENSIONS:-1500mm X1800mm (M.S.E.P) WORKING PRESSURE:- 2.5Kg/Sq.CmTEST PRESSURE:- 5Kg/Sq.CmSUPPLY and INSTALLATIONMAKE:-KSR/GREEN FORCE ENVIRO/SHRI RAM ENVIROTECH/OEM/AQUATECH
106PROVIDING,FIXING, TESTING and COMMISIONING OF VERTICAL SELF SUPPORTING CARBON SAND FILTER COMPLETE WITH MEDIA, PRESSURE GAUGES AT INLET and OUTLET WITH MANUAL BUTTERFLY VALVES. COMPLETED IN ALL RESPECT CAPACITY/FLOW RATE:-25M³/hrFILTRATION RATE:-APPROX (15M³/Hr/M²)FILTER DIMENSIONS:-1500mm X1800mm (M.S.E.P)WORKING PRESSURE:- 2.5Kg/Sq.CmTEST PRESSURE:- 5Kg/Sq.CmSUPPLY and INSTALLATIONMAKE:-KSR/GREEN FORCE ENVIRO/SHRI RAM ENVIROTECH/OEM/AQUATECH
107SUPPLY,INSTALLATION,TESTING and COMMISSIOING OF CHLORINE DOSING SYSTEM COMPRISING OFCHLORINE DOSING PUMP CAPACITY (0-6 LPH)QTY:-2NO’S(1W plus 1S) COMPLETED IN ALL RESPECTMAKE:-MILTONROY/GREEN FORCE ENVIRO/E -DOSE/W2PSR METERINGCHLORINE DOSING TANK CAPACITY-250 Ltr OF APPROVED BRANDSQTY:-1 NO
108SUPPLY,INSTALLATION,TESTING and COMMISSIOING OF 4” DIAL PRESSURE GAUGES TO MEASURE PRESSURE AT THE INLET and OUTLET OF PUMPS, BLOWERS and FILTERS.COMPLETED IN ALL RESPECT (MAKE:- H GURU/BELLS CONTROL
109SUPPLY, INSTALLATION,TESTING and COMMISSIOING OF ELECTROMAGNETIC FLOW METER WITH SUITABLE SPARE PARTS IN DISCHARGE OF SEWAGE TRANSFER PUMP IN TREATED WATER LINE. COMPLETED IN ALL RESPECT FLOW:-30M³/Hr (Max) MAKE:- MAAS ENGINEERS/KSR//EandH/ ASTER/ELECTRO-FLOW/W2P/FORBES/HOUSER
110SLUDGE DEWATERING SYSTEMSUPPLY,INSTALLATION,TESTING and COMMISSIOING OF MONOBLOCK PUMP FOR SLUDGE RECIRCULATION WITH MOTOR OF C.I PARTS and MECHNICAL SEAL COMPLETE WITH ISOLATION and NON RETURN VALVES, INCLUDING NECESSARY FITTING REDUCES, ELBOW ETC TO RUN. COMPLETED IN ALL RESPECTCAPACITY/FLOW RATE:- 25M³/HrHEAD-8-10MTR1SET:- 4NO’S PUMP(1 W plus 1S) R.P.M:-2900M.O.C:- C,I CASING/C.I IMPELLER/C.S SHAFTLOCATION:-STP ROOM MAKE:-WILO/KIRLOSKAR/KSB
111SUPPLY, INSTALLATION, TESTING and COMMISSIOING OF SCREW TYPE CENTRIFUGE FEED PUMP ALONG WITH CONTROL VALVES, SUCTION and DELIVERY HEADERS and FITTING. THE CAPACITY OF 5M³/Hr PER PUMP@40MWC HEAD. COMPLETED IN ALL RESPECT MAKE:-KSR ENGINEERS/GREEN FORCE ENVIRO/SYNERZZ SOLUTIONS/WILLO/KIRLOSKER/KSB
112SUPPLY, INSTALLATION, TESTING and COMMISSIOING OF BASKET TYPE CENTRIFUGE ,MSEP FRAME,S.S 304 BASKET HAVING DIA 1000MM. COMPLETED IN ALL RESPECT(MAKE:-KSR ENGINEERS/GREEN FORCE ENVIRO/SYNERZZ SOLUTIONS/SHRI RAM ENVIROTECH/W2P/AQUATECH
113SUPPLY, INSTALLATION, TESTING and COMMISSIOING OF POLY DOSING SYSTEM COMPRISING OF:-DOSING PUMP CAPACITY (0-6 LPH)QTY:-2NO’S(1W plus 1S) COMPLETED IN ALL RESPECTMAKE:-MILTON ROY/GREEN FORCE ENVIRO/E -DOSE DOSING TANK CAPACITY-250 Ltr OF APPROVED MAKEQTY:-1 NO
114SUPPLY, INSTALLATION, TESTING and COMMISSIOING OF PVC PIPE UNDER WATER and M.S.E.P ABOVE WATER,ALL PIPING OF STP and ISOLATION CONTROL VALVES FOR MAKING THE SYSTEM COMPLETE.COMPLETED IN ALL RESPECTPVC MAKE:- SUPREME/PRINCE/ASHIRWADM.S MAKE:- TATA/JINDAL/SAILELECTRICALS
115DESIGN, FABRICATION, ASSEMBLING, WIRING, SUPPLY, INSTALLATION TESTING AND COMMISSIONING OF MOTOR CONTROL CENTRE FABRICATED OUT OF 14 GAUGE CRCA SHEET STEEL CABLE GLAND PLATES SHALL BE PROVIDED ON TOP AS WELL AS AT THE BOTTOM OF THE PANELS. PANELS SHALL BE TREATED WITH ALL ANTICORROSIVE PROCESS BEFORE PAINTING AS PER SPECIFICATIONS WITH 2 COATS OF RED OXIDE PRIMER AND FINAL APPROVED SHADE OF POWDER COATED PAINT 2 NOS EARTHLING TERMINALS SHALL BE PROVIDED FOR 3 PHASE, 4 WIRE, 50 HZ SUPPLY SYSTEM. PANEL SHOULD BE COMPLETE WITH ISOLATION PUSH BUTTON FOR EVERY EQUIPMENT AND AUTO MANUALSELECTION SWITCHES (AS PER ACTUAL EQUIPMENT RATING AND AS PER MANUFACTURER STANDARDS), MAKE-W2PPANEL FEATURESENERGY METER AND VIFINCOMINGONE NO. AMPS TP INCOMING MCCB COMPLETE WITH THE FOLLOWING0-500 VOLTS 96X96 SQUARE MM VOLTMETER WITH SELECTOR SWITCH AND FUSES. 0 AMPS 96X96 SQUARE MM AMMETERWITH......./5 AMPS RATIO CT`S ANDSELECTOR SWITCHPHASE INDICATING LAMPS WITH TOGGLE SWITCHES.INDICATION LAMPS FOR ON/OFF/TRIP STATUS OF MOTORS.OUTGOINGAS PER STP EQUIPMENT CONTROL PANEL AS DESCRIBED ABOVE COMPLETED IN ALL RESPECT
116SUPPLY and LAYING OF ALUMINUM/COOPER ARMORED/UNARMOURED CABLE OF SIZE AS PER EQUIPMENT RATING ALONG WITH SUPPORTS. COMPLETED IN ALL RESPECT MAKE SCHENDER/LandT/HAVELS/PLAZA
117SUPPLY,INSTALLATION,TESTING and COMMISSIOING OF MEDIA RETAINING SCREENQTY:3 NO’S(2 NO’S IN MBBR and I NO IN TUBE SETTLER) COMPLETED IN ALL RESPECTMAKE:W2P/GREEN FORCE EENVIRO/KSR ENGINEERS/JASH/MACHINOTECH AQUATECH Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58242357
AUTHORITY Government Departments
TENDER VALUE 1.22 Crore
LAST DATE 10-11-2026
Authority
Authority Name Haryana Police Housing Corporation Limited
Work Description Tender for Up-Gradation Of Existing Sewage Treatment Plant In Police Lines, Fatehabad.
Basic Detail
Tender No 20268FA5DF4B FA05 441E BCA1 766F4F8A5DDF57HHC
Bidding Type Tender
Location
City Fatehabad
State Haryana
Key Dates
Publish Date 28 Oct 2026
Submission Date 10 Nov 2026
Open Date 11 Nov 2026
Finance
Tender Value 1.22 Crore
Tender Fee 17700
EMD 2.46 Lakhs
Exemption Available
Document List
777951Z175407.pdf
BOQ_636067.xls
f3857169-f8bb-4f78-98de-8c32e50b50a4.html
OT0175407.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
pdf

777951Z175407.pdf

xls

BOQ_636067.xls

html

f3857169-f8bb-4f78-98de-8c32e50b50a4.html

pdf

OT0175407.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender