Agriculture Boards / Undertakings / PSU Closing in 7 days TDR #58241164

Tender For annual repair maintenance Electrical Works At Fsd Sevur For The Fy 2026-27 - Replacement Of Old And Damaged Ug Cables, Renovation Of Electrical Fittings Of Toilets, Providing Power Sockets To Ad Cabins, Replacement Of Damaged Light Fitting

Issued by Boards / Undertakings / PSU · Vellore, Tamil Nadu
Tender Value
10.22 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
7 days left
EMD
20450
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vellore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for annual repair maintenance Electrical Works At Fsd Sevur For The Fy 2026-27 - Replacement Of Old And Damaged Ug Cables, Renovation Of Electrical Fittings Of Toilets, Providing Power Sockets To Ad Cabins, Replacement Of Damaged Light Fittings Inside Godowns And Other Allied Works

BOQ

Name of Work:- ARMO Electrical Works at FSD Sevur for the FY 2026-27 - Replacement of old and damaged UG cables, renovation of electrical fittings of toilets, providing power sockets to AD cabins, replacement of damaged light fittings inside godowns and other allied works
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group B
2Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm)
4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)6 way, Double Door.
5Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
6Supplying and fixing FP sheet steel enclosure on surface/ recess along with 25/32 A 415 V \\"C\\" curve TPN MCB complete with connections, testing and commissioning etc. as required.
7Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole
8Single Pole and Neutral
9Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
10Supplying, installation,testing and commissioning of 1200 mm retrofit LED tube with suitable boxtype batten on wall/ ceiling/ truss with suitable fitting arrangements to terminate the metal conduit wiring with check nut to the fittings including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required. (non compact type) (ISI certified)
11Supplying, installation, Testing and commissioning of 70 Watt LED type Well Glass Light in pressure die-cast Aluminium housing and fixing on truss with suitable clamps, nut and bolts including connection, testing etc., as required. (ISI certified) (Rating IP66, Luminar efficacy>120Lm/W, CRI>75)
12LED Down lighter (SMD Type)(System lumen efficacy ≥ 105 < 120 lm/Watt)Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 50C to 40C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body including trim12-15 watt
13Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 watt
1490 watt
15Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).70 W
16250 W
17Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
18Supplying of PVC insulated, PVC sheathed / XLPE aluminium conductor armoured under ground power cable of 1.1 KV grade conforming to IS 1554 part-I/7098(part-I) 1998 with up to date amendments of the following sizes.3 x 6 sq mm
194 x 16 sq mm
20Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm
21Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
22Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
23Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia
24Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required.
25Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required2 x 10 sq. mm (19 mm)
264 x 16 sq. mm (28 mm)
27Supplying and fixing hot press molded SMC box of size 250mm x 200mm x 105mm (inside) on wall/ truss/pole with suitable clamps including providing and fixing suitable 3 way connector and din bar for fixing MCBs terminating the incoming and out going cables /wires (but with out end termination glands) making connections etc. as required
28Supplying and fixing of propeller type heavy duty exhaust fan of sweep 300 mm, single phase, 230 Volts, 50 Hz, having metallic body and blades, pre-treated for anti-corrosion, complete with a square steel frame and flexible cord including wiring, testing and commissioning on wall surface as required as per site conditions.
29Supply of 6 meter high hot dipped galvanised octagonal pole with 130mm bottom dia & 70mm top dia made up of 3mm thick HT sheet along with base plate of size 200x200x12mm thick along with 4 nos of 20x600 high J type EN8 grade foundation bolts along with template to fix the pole to the foundation and supply and fixing of 2 mtr long hot dipped galvanized double arm bracket made up of 40 NB GI pipe mounted on pole for mounting street light fixture as required at the site work
30Erection of 6 mtr octagonal pole by making cement concrete of 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate) (M20) foundation having cross section of 400x400 mm and depth of 1400 mm with steel reinforcement, excavation, refilling, centering along with fixing of 20x600 mm long foundation bolt into foundation for anchoring pole and laying of flexible PVC pipe for cable entry and giving necessary cable termination connections at pole base and supply & laying 1.5 sqmm multicore flexible cable from pole base to light fixtures as required.
31Supplying of wall reclining Aluminium extension Ladder of 14'+14' length with 1\\" fluted pipe section steps with load rating of 150 kg etc at site of works as required.
32Supply of Self supporting Aluminium Ladder of 3.05Mtr (10’) with 74mm x 28.5mm channel section steps with load rating of 150 kg etc at site of works as required.
33Cutting the bituminous/ CC road for trenching and cable laying and after cable laying and making good the road with suitable grade cement concrete of 1:3:6 ratio as required at the site of work.
34Credit items to be taken out
35Dismantled DBs, Switch boards, Iron pipes, any misc iron scrap etc
36Dismatled Well glass/Street light fittings
37Dismantled Ceiling fans/exhaust fans
38Dismantled aluminium insulated wire/cables Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58241164
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 10.22 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for annual repair maintenance Electrical Works At Fsd Sevur For The Fy 2026-27 - Replacement Of Old And Damaged Ug Cables, Renovation Of Electrical Fittings Of Toilets, Providing Power Sockets To Ad Cabins, Replacement Of Damaged Light Fittings Inside Godowns And Other Allied Works
Basic Detail
Tender No 8.2/2026-27 FSD Sevur ARMO
Bidding Type Tender
Location
City Vellore
State Tamil Nadu
Key Dates
Publish Date 28 Oct 2026
Submission Date 09 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 10.22 Lakhs
Tender Fee Ref. Documents
EMD 20450
Exemption Not Available
Document List
6314b24a-9758-4e08-8d65-8c5f7c39a9b6.html
BOQ_979464.xls
PB_SVR.pdf
TB_SVR.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

6314b24a-9758-4e08-8d65-8c5f7c39a9b6.html

xls

BOQ_979464.xls

pdf

PB_SVR.pdf

pdf

TB_SVR.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender