Tender for New Construction Of O.S.T/ O.O.A.T Centre Building In Chc, Mc Morinda, Assembly Constituency Sri Chamkaur Sahib, Distt. Rupnagar.
BOQ
| Sl. No. | Item Description |
| 1 | Civil WorkExcavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bttom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres. |
| 2 | Cement concrete 1:4:8 with 40 mm gauge stone ballast.using concrete mixer volumetric type. |
| 3 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 4 | Reinforced cement cocrete M-25 mechanicaly batch mixed using batch type mixer and needle vibrator but excluding steel reinforcement, centering and shuttering in foundation and plinth. |
| 5 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 6 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 7 | Centring and shuttering for foundations. Shuttering for faces of concrete foundations and foundation beams ( vertical or battering ). |
| 8 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the complex in 15 cm layers including ramming, watering and consolidating including all leads. |
| 9 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 10 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain). |
| 11 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 12 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 13 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. |
| 14 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 15 | Supplying Japani sheet frames (chowkhat) consisting of 18 gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 16 | Base course under floor flor consisting of 100 mm C.C 1:8:16 and 100 mm Sand filling |
| 17 | Cement Plaster 1:5 12.5 mm Thick Plaster |
| 18 | 20 mm thick Cement plaster |
| 19 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 20 | Cement concrete 1:2:4 gola 10 cm. x 10 cm. quardrant along junction of roof with parapet wall finished smooth, where specially specified. |
| 21 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999)) Commercial with elm or gurjan facing on both Sides with laminated core and lipped edges:- 35mm thick |
| 22 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 23 | Supplying and fixing glass panes with glazingclips and special metal sash putty of approved make. Glass panes 4mm. |
| 24 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items). |
| 25 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 26 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) ( a ) Size 600 x 600 mm. |
| 27 | Precast chequred tiles of 20mm minimum thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base for floors, treads of steps and landings. |
| 28 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 29 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 30 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300 x 16 mm |
| 31 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size ofdoor 851mm to 1000mm) |
| 32 | Plinth Protection Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 33 | Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by manual means |
| 34 | First class burnt brick work laid in cement sand mortar 1:6 in foundation plinth. |
| 35 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the complex in 15 cm layers including ramming, watering and consolidating including all leads. |
| 36 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand fillingusing mechanical mixer for mixing of material |
| 37 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 38 | 12.5 mm cement plaster 1:5 |
| 39 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 40 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 41 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade qty same as per 12.5 mm Thick Plaster. |
| 42 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqmqty same as per 20 mm Thick Plaster |
| 43 | Extra for Smooth Surface for Slab (Qty. as per Item no. 13) |
| 44 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. |
| 45 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4.0 kgf / cm²) conforming to IS : 4985, including fixing with M.S. clamps U-PVC pipes (working pressure 4.0 kgf. / sqcm) Pipe 110 mm dia. |
| 46 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend. |
| 47 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend. |
| 48 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 49 | Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3. |
| 50 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 51 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 52 | Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers). |
| 53 | Precast Cement Concrete Kerb (a) Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications. |
| 54 | Cement concrete 1:4:8 with 40 mm gauge stone ballast.using concrete mixer volumetric type. |
| 55 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with Rubber moulded to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. |
| 56 | SHEDSUB HEAD NO. 1 (FOUNDATION WORK)Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 57 | Cement Concrete 1:4:8 with 40mm gauge stone aggregate. Using volumetric concrete mixer. |
| 58 | RCC M-25 mechanically mixed using batch type concrete mixure as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement in foundation & plinth. |
| 59 | RCC M-25 mechanically mixed using batch type concrete mixure as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement in super structure & plinth. |
| 60 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete. |
| 61 | Nuts & Bolts of all sizes and length required |
| 62 | Centring and Shuttring for faces of conceate foundation CSR 9.1 (Foundation Beam and PL Beam) |
| 63 | Centring and Shuttring fo Column. |
| 64 | Steel work fixed independently without connecting plates including cutting hoisting and fixing in position Angle Iron 50 x 50 x 6mm. |
| 65 | SUB HEAD NO. 2 (STANCHION WORK)Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position. |
| 66 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span. |
| 67 | SUB HEAD NO. 3 (TRUSS & ROOFING)Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. |
| 68 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 69 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 70 | Extra labour for Painting or Priming coat on trusses/Gantry board or similar structures of height above 4 metre for every additional. |
| 71 | Sanitary Fixture in Toilets and Estate Services for Existing BlockExcavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. Earth work upto 1.5 m. Depth All classes of soil except rocky 370m x 0.5m x 1.0 m. |
| 72 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 90mm o/d pipe of 6 Kgf. / sqcm |
| 73 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 69x36x74 cm with P trap or S trap and seat cover complete in all respect. |
| 74 | Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 75 | Providing and fixing in position china ware European type water closet P trap or S trap of approved make (to approval of engineer in charge) consisting of 10 ltr PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of engineer in charge. |
| 76 | Providing and fixing Jet Spray with 2'-6'' long PVC pipe With CP brass nut. |
| 77 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 550 mm x 400 mm x 815 mm |
| 78 | Providing and fixing in position 5mm thick beveled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm C.P brass screws and washers and S/S studs on top complete in all respect (as required by the engineer-in- charge) Size 550 x 400 mm |
| 79 | Providing and fixing PVC waste pipe 32mm complete in all respect. |
| 80 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-Charge) fixed in with rawl plugs embedded in walls with brass screws, complete in all respects. (b) CP brass towel rail 15mm dia 600mm long. |
| 81 | Providing and fixing in position 15mm i/d bib cock of approved make (to the approval of Engineer-in-Charge) complete in all respect.C.P. brass Bib cock long nose /long body without flange. |
| 82 | C.P. brass Bib cock without flange. |
| 83 | Providing and fixing in position stop cock/angle valve of approved make (to the approval of Engineer-in-Charge) complete in all respect.C.P. brass 15 mm concealed stop cock with flange. |
| 84 | C.P. brass 15 mm angle valve without flange. |
| 85 | P/F in position PVC flexible tube connection of approved make (to the approval of Engineer-in-Charge) Complete in all respect.PVC tube connection of size 15mm x450 mm with CP brass nut. |
| 86 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-Charge) including cutting, jointing, wastage, but excluding cost of lead jointing.Type B110mm o/d SWR UPVC pipe lines laid complete |
| 87 | 75mm o/d SWR UPVC pipe lines laid complete |
| 88 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per IS - 14735 of approved make (to the approval of Engineer-in-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipe Single junction with door |
| 89 | Single junction plain. |
| 90 | Bend with door. |
| 91 | P Trap/Floor Trap 110 mm x 110 mm. |
| 92 | For 90mm o/d pipe Single junction with door. |
| 93 | Single junction plain. |
| 94 | Bend with door. |
| 95 | Plain Bend. |
| 96 | Collars. |
| 97 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. SDR 11 CPVC pipes & fittings 20mmo/d |
| 98 | Cutting holes upto 23cm tsquare through B.B in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required.Through walls11.43 thick |
| 99 | Through walls 22.86 thick. |
| 100 | Disilting all types of main sewers 760 mm and onwards internal dia by silt clearing machines addopting all safety measures and disposal of silt upto 5km complete in all respects. |
| 101 | Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge.Eurpoean/Indian/Orissa W.C., |
| 102 | PVC / China Ware Cistern. |
| 103 | Wash Hand Basin / Urinal Pot. |
| 104 | CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap. |
| 105 | Wall mixer / Sink Mixer / Basin Mixer / Concealed Stop Cock. |
| 106 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 107 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm. |
| 108 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.a ) Vertical type25 litre capacity water heater |
| 109 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Full Steel Body 150/150 ltr without Stablizer |
| 110 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 111 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks (2000 x 1). |
| 112 | Providing, fixing and jointing ISI Marked gun-metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I Pipe lines laid in the ground or inside buildings including all carriages complete15mm i/d Gun Metal peet valve heavypattern. |
| 113 | 32mm i/d Gun Metal peet valve heavypattern. |
| 114 | Providing and fixing in position automatic brass ball Cock in tanks.Brass ball Cock with rod and platic ball20mm i/d |
| 115 | AUTOMATIC VOLTAGE STABLIZER: Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 4 KVA. |
| 116 | P&F Washing Machine Haier 14 kg Toughened Glass with Anti Bacterial Vortex Pulsator, 1300 RPM, Spray Function, Wash Programs, Magic Filter, Rat Mesh Semi Automatic Top Load Black (HTW140-178BK). |
| 117 | Sanitary Fixture in Toilets and Estate Services for New BlockProviding and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 118 | Providing and fixing in position china ware European type water closet P trap or S trap of approved make (to approval of engineer in charge) consisting of 10 ltr PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of engineer in charge. |
| 119 | Providing and fixing Jet Spray with 2'-6'' long PVC pipe With CP brass nut. |
| 120 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 550 mm x 400 mm x 815 mm. |
| 121 | Providing and fixing in position 5mm thick beveled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm C.P brass screws and washers and S/S studs on top complete in all respect (as required by the engineer-in- charge) Size 550 x 400 mm. |
| 122 | Providing and fixing PVC waste pipe 32mm complete in all respect. |
| 123 | Providing & Fixing in position C.P./ Aluminium Khunti of approved make (to the approval of Engineer-in-Charge ) fixed into wall with CP brass screws and rawl plugs etc. complete in all respect.Aluminium khunti with 4 pegs. |
| 124 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-Charge) fixed in with rawl plugs embedded in walls with brass screws, complete in all respects. (b) CP brass towel rail 15mm dia 600mm long. |
| 125 | Providing and fixing in position 15mm i/d bib cock of approved make (to the approval of Engineer-in-Charge) complete in all respect.C.P. brass Bib cock without flange. |
| 126 | Providing and fixing in position stop cock/angle valve of approved make (to the approval of Engineer-in-Charge) complete in all respect.C.P. brass 15 mm concealed stop cock with flange. |
| 127 | C.P. brass 15 mm angle valve without flange. |
| 128 | P/F in position PVC flexible tube connection of approved make (to the approval of Engineer-in-Charge) Complete in all respect.PVC tube connection of size 15mm x450 mm with CP brass nut. |
| 129 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-Charge) fixed into wallwith rawl plugs and C.P brass screws complete in all respect. |
| 130 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-Charge) including cutting, jointing, wastage, but excluding cost of lead jointing.Type B110mm o/d SWR UPVC pipe lines laid complete |
| 131 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per IS - 14735 of approved make (to the approval of Engineer-in-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipe Single junction with door. |
| 132 | Single junction plain. |
| 133 | Bend with door. |
| 134 | Plain bend. |
| 135 | Cowls. |
| 136 | Collars. |
| 137 | P Trap/Floor Trap 110 mm x 110 mm. |
| 138 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge..CPVC SDR 11 Pipe & fitting 16mm o/d |
| 139 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 140 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval EIC) as per IS 1879 in G.I Pipe lines complete in all respect.15mm i/d G.I. union |
| 141 | 20mm i/d G.I. union |
| 142 | Providing, fixing and jointing ISI Marked gun-metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I Pipe lines laid in the ground or inside buildings including all carriages complete15mm i/d Gun Metal peet valve heavypattern. |
| 143 | 32mm i/d Gun Metal peet valve heavypattern. |
| 144 | Cutting chase in brick wall in cement or floor for embedding G.I.or C.I pipes lines and making good the same to its original condition(size 75 x 75mm ). |
| 145 | Cutting holes upto 23cm tsquare through B.B in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required.Through walls11.43 thick |
| 146 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand or stone filling. |
| 147 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 148 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 149 | Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging of sewer, desilting, removal of sludgewater and making good of khudda.Sewer Connection Upto 300mm i/d |
| 150 | Providing and fixing in position automatic brass ball Cock in tanks.Brass ball Cock with rod and platic ball20mm i/d |
| 151 | Disilting all types of main sewers 760 mm and onwards internal dia by silt clearing machines addopting all safety measures and disposal of silt upto 5km complete in all respects. |
| 152 | Providing and fixing in position vitreous Chinaware white lndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 153 | Providing and fixing partition for different type of urinals.Vitreous white Chinaware PartitionSmall partitions size 69 x 16.5 x 32.5 cm |
| 154 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with grating 150mm x 150mm cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150mm with a minimum seal 50mm.100mm internal diametre H.C.I gully trap with H.C.I. grating and SFRC cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm. |
| 155 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.Size 450mm x 450mm inside with RCC 455mm x 455 mm cover and frame medium duty double seal. |
| 156 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.Inside size 90x150 cm and 120 cm deep. |
| 157 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 158 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks. |
| 159 | Providing and fixing in position paper holders of approved make (to the approval of Engineerin- charge ) fixed in to wall with C.P brass screws complete in all respect.C.P. brass toilet paper holder. |
| 160 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 161 | Construction of brick masonry Platfarm for PVC Water Storage Tank. |
| 162 | P&F MTA/FTA |
| 163 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVCpipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.160mm o/d pipe |
| 164 | ELECTRICALRECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (with fan box ) |
| 165 | Wiring light point. |
| 166 | Wiring call-bell point. |
| 167 | Wiring 6 Amp. wall socket point. |
| 168 | Wiring 16/20 amp. power plug control point. |
| 169 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 170 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) |
| 171 | Overall size 2.5sq.mm (Un-sheathed) |
| 172 | Overall size 4sq.mm (Un-sheathed) |
| 173 | Overall size 10sq.mm (Un-sheathed) |
| 174 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 10sq.mm (2Core) Un-armoured (Loose) |
| 175 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 176 | HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 177 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 178 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 179 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-PVC flexible pipe 25mm dia. |
| 180 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 181 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 182 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 183 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 4 way each |
| 184 | SHEET METAL IRON CLAD SWITCHES: Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-ICDP Switch 32amp., 415volts |
| 185 | Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48” (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos. of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM. Complete in all respects as desired by the Engineer in charge of work at site. |
| 186 | Supply and Erection of Heavy Duty Exhaust Fan Suitable size 12” (300mm) including Louver shutter, connection & testing complete in all respects as desired by the Engineer in charge of work at site. Exhaust Fan, Blade Sweep : 300 mm (12”), Type of motor : Permanent capacitor induction motor, C75 Rated Voltage : 230 volts, 50 Hz, AC. single Phase, Test voltage : 230 volts, 50 Hz, .AC. I Phase, Frequency : 50 Hz., Capacitor rating : 1.0 F, 400V, 50 Hz, AC., Rated watts at full (load) speed & at 230V. : 27 watts., Current in amps at full speed & at 230 V. : 0.12 Amps., Power factor : 0.9 min., Rated full speed & at 230 V : 1310 rpm., Rated air delivery at 230 V : 800 M3/hr, Rated Service value : 30 m3/hr/watt, No. of blades leaves : Five, Type of blade leaf : Plastic (PP), No of running positions : One position, Class of Insulation : Class “E”, Type of bearings : Oil impregnated self aligned bush bearings. |
| 187 | Supply and Erection of 36 Watt 2X2 Surface mounted LED Luminaire (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. |
| 188 | Supply and Erection of 100 Watt LED Flood Light fitting (including LED driver) with pressure die cast aluminium housing with control gear (IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. |
| 189 | Air ConditionProviding and installing O-General / Daikin / Hitachi / Mitsubishi / Toshiba / Cerrier make 5/3-Star rating (Hi-wall Cooling only without installation kit i.e. Copper Pipe) or any other equivalent make Split type invertor Air Conditioner of 2.0 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including installation charges. |
| 190 | Providing and installing O-General / Daikin / Hitachi / Mitsubishi / Toshiba / Cerrier make 5/3-Star rating (Hi-wall Cooling only without installation kit i.e. Copper Pipe) or any other equivalent make Split type invertor Air Conditioner of 1.5 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including installation charges. |
| 191 | Providing and installing Automatic Voltage Stabilizer copper winding and having suitable range for input and output of 5 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect make V-Guard, Liv Guard, Luminous and any other equivalent make. |
| 192 | Providing & Fixing extra refrigerant copper pipe including cutting chase in walls & making good the same wall complete in all respect |
| 193 | Providing and fixing 15 mm i/d PVC drain pipe with specials for Split type Air Conditioner complete in all respects. |
| 194 | Provision of Angle iron stand for placeing out door AC unit. |
| 195 | Providing and fixing PVC 70/76, 3 Core Electrical Wire for Split type Air Conditioner complete in all respects. |
| 196 | Fire Fighting System (Extinguishers only)Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.6kg capacity |
| 197 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect4.5 kg capacity |
| 198 | OHSR RepairProviding and laying, jointing, fixing, testing ISI Marked G.I. Pipe 80mm (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 199 | Prov. Installing, testing & commissioning Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator ,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS. standard specifications. |
| 200 | Provision for automated Water Controller as per DWSS standards and specifications |
| 201 | Repair of OHSR (25KL capacity), incl external walls, internal walls, braces, ring beams, dome, fixing top jaali and cleaning of OHSR with suitable material. Work Complete in all respect incl centring, shuttering, scaffolding on Lumpsum Basis. |
| 202 | Provision of electric control panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB. Shunt Capacitor. Single Phase preventer, Indicating lamps, Kit-Kat etc. Complete Job. Refer standards of DWSS 10 BHP |
| 203 | Providing, installing, testing and commissioning of submerrisble pumping set of required discharge and head. Complete in all respects.10.00 BHP |
| 204 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in- charge) 100mm i/d Sluice Valves flanged. |
| 205 | Plinth protection for OHSR (Capacity 25000 L, Dia 5.55m) (Analysis A9-1 DWSS) |
| 206 | Repair of Pump Chamber |
| 207 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 2.5sq.mm (50/0.25mm), 3Core |
| 208 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department Size 0.9 m. x 0.9 m. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender