Tender For Repair / Maintenance / Servicing Of Cooling Appliances And Allied Works Under Ge Chennai
Tender Value
10 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
0 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance / Servicing Of Cooling Appliances And Allied Works Under Ge Chennai
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Nov-2026 | other_corrigendum | Other | 17-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/buzzer, bell push, lamp holders, regulators, sockets, light fittings etc. removing materials from site and making good to the disturbed surfaces of walls, ceiling floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed. |
| 2 | M&L for Point wiring complete with two runs of 2.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping/PVC Conduit pipe medium grade including provision of 2.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site complete all as specified and as directed. |
| 3 | M&L for Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type |
| 4 | M&L for sub main wiring Casing caping two run 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including casing caping complete including taking down all as specified and as directed. NOTE:- Two runs of 4.0 Sq mm+ one run of 4.0 Sq mm and one run of PVC conduit pipe and its accessories of suitable size shall be measured as one unit length. |
| 5 | M&L for sub main wiring Casing caping two run 6.0 Sq mm and one run of 6.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including casing caping complete including taking down all as specified and as directed. NOTE:- Two runs of 6.0 Sq mm +one run of 6.0 Sq mm and one run of PVC conduit pipe and its accessories of suitable size shall be measured as one unit length. |
| 6 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps incl taking down unserviceable complete all as specified and as directed. |
| 7 | M&L for in Replacement of MCB SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unsv MCB complete all as specified and as directed. |
| 8 | M&L for MCB SPN 40 to 63 Amps, 240 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete including taking down all as specified and as directed. |
| 9 | M&L for MCB SP 5-32 Amps, 240 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down complete all as specified and as directed. |
| 10 | Taking out the existing unserviceable compressor unit from Split type AC and Supply & Fix new hermetically sealed Rotary / Piston type compressor unit of same make of Split type AC suitable to operate in A.C single phase 50 HZ 230 volts for split type AC of capacity 1.5 & 2.0 ton including testing and commisioning etc., complete all as directed. Note : Freon Gas for charging shall be measured and paid separately. |
| 11 | Flushing the complete condensing unit, evaporator coil unit, compressor suction and delivery tubes and replacement of charging lines, strainers capillary tube etc., of Split type AC and rectification of the leakage from the system, vaccumising. dehydrating as per standard practice and gas charging including testing and commissioning of system all as directed. Note : Freon Gas for charging shall be measured and paid separately. |
| 12 | Taking out the unserviceable and Supply and fix new Fan motor of 1/6 HP RPM 950 AC single phase 50HZ Evaporator coil for the Split type Air conditioners of any make.Note: The spares shall be of same make of AC (or) of existing spare and shall conforming to IS specification |
| 13 | All as per item No.12 above but Condensor coil/Evaporator coil (or) cooling coil. |
| 14 | All as per item No.12 above but Hand smart remote control with PCB up to 2 ton |
| 15 | All as per item No.12 above but Hand smart remote control with PCB inverter type up to 2 ton |
| 16 | All as per item No.12 above but starting 45 mfd to 5 mfd capacitor suitable mfd for the driven machine |
| 17 | Replacement of unserviceable Indoor unit of split type AC 1.5 Ton capacity complete all as specifeid and directed by Engr-in-ChargeMake : LG / Carrier/Voltas/Sidwal/Samsung/Hitachi/Videocon |
| 18 | Supply only freon gas R-32 for charging to Window / Split type ACs |
| 19 | Taking down carefully, split type AC of any capacity by carefully disconnecting the electric connection and carrying out water washing, cleaning the filter and cooling coil and refixing the same in position including testing commissioning all as specified and directed. |
| 20 | Removing from existing location and shifting of split type AC of any capacity and fix factory made fabricated support suitable to mount outdoor unit (one pair per AC including drilling holes in walls for insertion of copper pipe, drain pipe and three core cable and making good the surfaces complete all as specified and directed. Make : Existing make |
| 21 | Replacement in repair of copper pipe with insulation tubular form of size 1/2 inch for split type AC |
| 22 | Replacement in repair of copper pipe with insulation tubular form of size 1/4 inch for split type AC |
| 23 | Replacement in repair of copper pipe with insulation tubular form of size 5/8 inch for split type AC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 11, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 17, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayTender Documents
Download All (ZIP) ↓