Tender For Maintenance And Repairs To Sewage Pumps, Air Blowers And Connected Misc Works Of Stp Under Ge (Af) Bidar
Tender Value
20 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
17 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bidar → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance And Repairs To Sewage Pumps, Air Blowers And Connected Misc Works Of Stp Under Ge (Af) Bidar
BOQ
| Sl. No. | Item Description |
| 1 | M&L for cleaning of sewage intake circular tank of size 7 mtr dia and 7 mtr depth by removing all sludge and de-scaling vegitation on the inside and outside of tank and white washing (Two coat) including cleaning the surrounding area of the tank to a distance of 3 meter circumstance including cutting of grass, digging out roots, filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete all as specified and as directed. |
| 2 | All as per Item No 01 but 6 mtr dia and 6 mtr depth complete all as specified and as directed. |
| 3 | M&L for cleaning of raw sewage rectangular tank of size 7.5 mtr x 5.4 mtr and 5 mtr depth by removing all sludge and de-scaling vegitation on the inside and outside of tank and white washing (Two coat) including cleaning the surrounding area of the tank to a distance of 3 meter circumstance including cutting of grass, digging out roots, filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete all as specified and as directed. |
| 4 | All as per Item No 03 but 6 mtr x 7 mtr and 8 mtr depth complete all as specified and as directed. |
| 5 | All as per Item No 03 but 4.45 mtr x 3.25 mtr and 2.5 mtr depth complete all as specified and as directed. |
| 6 | All as per Item No 03 but 8.4 mtr x 4.7 mtr and 2.5 mtr depth complete all as specified and as directed. |
| 7 | M&L for cleaning of treated water circular tank of size 9 mtr dia and 3 mtr depth by removing all vegitation on the inside and outside of tank and white washing (Two coat) including cleaning the surrounding area of the tank to a distance of 3 meter circumstance including cutting of grass, digging out roots, filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete all as specified and as directed. |
| 8 | All as per Item No 07 but rectangular tank of size 10.5 mtr x 4.5 mtr and 4 mtr depth complete all as specified and as directed. |
| 9 | All as per Item No 07 but rectangular tank of size 5.5 mtr x 4.6 mtr and 3 mtr depth complete all as specified and as directed. |
| 10 | All as per Item No 07 but rectangular tank of size 4.7 mtr x 2.2 mtr and 1.5 mtr depth complete all as specified and as directed. |
| 11 | M&L for cleaning of tube settler tank rectangular tank of size 5 mtr x 2.6 mtr and 2.5 mtr depth by removing all sludge and de-scaling vegitation on the inside and outside of tank and white washing (Two coat) including cleaning the surrounding area of the tank to a distance of 3 meter circumstance including cutting of grass, digging out roots, filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete all as specified and as directed. |
| 12 | All as per Item No 11 but 3.3 mtr x 3.1 mtr and 3 mtr depth complete all as specified and as directed. |
| 13 | All as per Item No 11 but 2.65 mtr x 2.2 mtr and 2.2 mtr depth complete all as specified and as directed. |
| 14 | M&L for cleaning of MBBR tank rectangular tank of size 2 mtr x 2.8 mtr and 3 mtr depth by removing all sludge and de-scaling vegitation on the inside and outside of tank and white washing (Two coat) including cleaning the surrounding area of the tank to a distance of 3 meter circumstance including cutting of grass, digging out roots, filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete all as specified and as directed. |
| 15 | All as per Item No 14 but 3.1 mtr x 3.1 mtr and 3 mtr depth complete all as specified and as directed. |
| 16 | All as per Item No 14 but 2.55 mtr x 2.2 mtr and 2.8 mtr depth complete all as specified and as directed. |
| 17 | All as per Item No 14 but cylindrical tank of 1.5 mtr dia and 4 mtr depth complete all as specified and as directed. |
| 18 | M&L for cleaning of sludge holding tank rectangular tank of size 10 mtr x 5 mtr and 0.6 mtr depth by removing all sludge and de-scaling vegitation on the inside and outside of tank and white washing (Two coat) including cleaning the surrounding area of the tank to a distance of 3 meter circumstance including cutting of grass, digging out roots, filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete all as specified and as directed. |
| 19 | M&L for cleaning of CCT tank rectangular tank of size 5 mtr x 1.5 mtr and 1.5 mtr depth by removing all sludge and de-scaling vegitation on the inside and outside of tank and white washing or enamel paint (Two coat) including cleaning the surrounding area of the tank to a distance of 3 meter circumstance including cutting of grass, digging out roots, filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrscomplete all as specified and as directed. |
| 20 | All as per Item No 19 but 3.1 mtr x 2 mtr and 2 mtr depth complete all as specified and as directed. |
| 21 | All as per Item No 19 but 2.7 mtr x 2.2 mtr and 1 mtr depth complete all as specified and as directed. |
| 22 | M&L for lifting and taking out the sewage submersible pump set and motor of capacity 7.5 to 10 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage sump /well and lowering back the pump after repairing /removing the sludge from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as specified and as directed.Note :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete. |
| 23 | All as per item No 22 but of capacity 1 HP to 2 HP complete all as specified and as directed. |
| 24 | M&L for rewinding of Submersible sewage pump by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried ,rewinding the motor using required gauge of super enameled copper winding wire, varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 7.5 HP to 10 HP complete all as specified and as directed. |
| 25 | All as per item No 24 but of capacity 1 HP to 2 HP complete all as specified and as directed. |
| 26 | M&L for repairing and testing of pump centrifugal/mono block/non clogging of capacity 0.5 to 5 HP of any make and type including welding work, rotor turning and balancing, re-metaling of shaft bush bearing, keys, mechanincal seal, SS shaft impeller and other such accessories etc required to make pump functional and testing on load complete all as specified and as directed. |
| 27 | All as per item No 26 but of capacity 7.5 HP complete all as specified and as directed. |
| 28 | All as per item No 26 but of capacity 15 HP complete all as specified and as directed. |
| 29 | All as per item No 26 but of capacity 20 HP complete all as specified and as directed. |
| 30 | M&L for rewinding of electric motor of capacity 0.5 to 1.5 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed. |
| 31 | All as per item No 30 but of capacity 5 HP to 7.5 HP complete all as specified and as directed. |
| 32 | All as per item No 30 but of capacity 15 HP complete all as specified and as directed. |
| 33 | All as per item No 30 but of capacity 20 HP complete all as specified and as directed. |
| 34 | M&L for dismantling and taking up unserviceable sewage feed pump screw type pump set of capacity 2 HP from foundations after disconnecting electric and water connections and cleanings the screw rotors, greacing the bearings by opening nut-bolts & washers at site and reassembling the same after necessary work complete all as specified and as directed. |
| 35 | M&L for servicing of air blower of capacity upto 300 m³/Hr, 1790 RPM with positive displacement type twin lube root blower with motor of 15 HP, including opening the blower motor blower shaft, shaft Key ways, shaft holes etc and replacing the gland packing, gland nuts, coupling, replacement of oil seal including oil and re-fixing the same to the original position and commissioning testing complete all as specified and as directed. |
| 36 | All as per item No 35 but of capacity 83 m³/Hr and motor capacity 5 HP complete all as specified and as directed. |
| 37 | Supply and fill Compressor Oil as required in compressors complete all as specified and directed. |
| 38 | Supply and fix in replacement Air blower belt as per existing size complete all as specified and directed. |
| 39 | Supply and fix in replacement pressure guage 4\\" dia, 0-21 Kg/cm2 rating complete all as specified and as directed. |
| 40 | Supply fixing, testing and commissioning in replacement of 0-6 LPH electrically operated, metered, adjustable dosing pump with accssories including lead tubing , connecting nuts injection check valve with 60 ltr PE/ FRP tank fitted with agiatator all as directed by Engineer-in-Charge E tank with PE/FRP/HDPE lid and level gauges, mounted on tank complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 41 | Supply fixing, testing and commissioning in replacement of 0-6 LPH electrically operated, metered, adjustable dosing pump with accssories including lead tubing , connecting nuts injection check valve with 60 ltr PE/ FRP tank fitted with agiatator all as directed by Engineer-in-Charge E tank with PE/FRP/HDPE lid and level gauges, mounted on tank complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents