Tender for Special Repair To High Tension (Ht) Network System, Rmu, Relays, Vcb And Other Connected Works Under Ge (A) Ahmedabad Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE (A) AHMEDABAD REVISED BOQ NAME OF WORK: SPECIAL REPAIR TO HIGH TENSION (HT) NETWORK SYSTEM, RMU, RELAYS, VCB AND OTHER CONNECTED WORKS UNDER GE (A) AHMEDABAD CANTT Contract No: CWE (A)/ABD/ OF 2026-27 SERIAL PAGE NO Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL NO ITEM DESCRIPTION Item Code / Make QTY UNITS Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Material & Labour for Testing & Calibration of VCB Protection Relay any make and type (Digital / Numerical Over current relay / Earth Fault Relay , Differential relay, Auxiliary) after Isolation of the relay / CT-PT secondary circuits and visual inspection of wiring, terminals and relay case for damage/moisture ingress and cleaning of relay case, terminal blocks and test-plug contacts carried out secondary injection test of the relay using a calibrated relay test kit and pick-up current/voltage, time-current characteristic (definite time / IDMT curve as set), and instantaneous element check against the approved relay setting sheet as well as primary injection test to verify CT ratio, polarity and over all protection scheme continuity from CT through relay to trip coil including check the Trip-circuit healthiness / continuity and verification & re-entry of relay settings as per the latest approved protection co-ordination as per requirment and then again carried out functional trip test / relay operation to actually trip the associated breaker complete all as specified and directed.Note :- (i) Necessary T & P for repair will be in the scope of contractor / own arrangement of the contractor. (ii) Arranging power shutdown/outage with the Discom (to be coordinated through the consern JE E/M / Engineer-in-Charge). |
| 3 | Repair, Maintenance, Servicing and recommissioning, Testing of 11 KV Vacuun Circuit Braker (VCB) of any make, capacity and type (Fixed / Withdrawable) complete with Isolation, withdrawal (for withdrawable type) or de-energising & earthing (for fixed type) of the VCB truck before the work start and dismantling of the breaker pole assembly for visual inspection of vacuum interrupter bottles, insulation, operating rod and contact travel and carried out contact-resistance test across each pole; vacuum-integrity test on each interrupter bottle (HV withstand / lightning-impulse type test surrogate as per OEM procedure and overhaul of spring-charging/operating mechanism (i.e.springs, cams, bearings, linkage, gear-train), lubrication and checking closing/tripping-time measurement including contact-travel, contact-wipe and simultaneity (phase-to-phase closing/opening time difference and do the adjustment as per OEM tolerance limit complete with Insulation Resistance test and functional test of all inter-locking between (earth-switch / breaker / door), mimic diagram and indication lamps / flags after that re-assembly, racking-in (withdrawable type) and functional trial operation (local & remote) complete all as specified and directed.Note :- (i) Necessary T & P for repair will be in the scope of contractor / own arrangement of the contractor. (ii) Spare part required for replacement shall be measured and paid for separately under supply only item in respective item of this schedule.(iii) Arranging power shutdown/outage with the Discom (to be coordinated through the consern JE E/M / Engineer-in-Charge). |
| 4 | Repair, Maintenance, Servicing and recommissioning, Testing of 11 KV Ring Main Unit (RMU) of any make and capacity complete after De-energising, isolating, discharging and earthing the RMU before starting work and opening RMU enclosure/tank for visual & physical inspection of bushings, cable boxes, interlocks, gaskets and insulating surfaces including cleaning of internal chambers, bus-bars, contacts, insulators/bushings with contact cleaner/solvent and lint-free cloth and carried out mechanical operation check (manual & electrical like open / close / trip and contact-resistance test on VCB & LBS main contacts including overhaul of charging spring, check spring-tension, operating mechanism, lubrication, caMaterial and labourinkage adjustment and replacement of unserviceable parts and charging of SF6 gas up to (due-point) pressure & moisture if found deficient and carried out Insulation Resistance (IR) test at 5kV on all phases-to-earth and phase-to-phase after repair work carry out High-Voltage test with stand as per manufacturer's manual and functional test of all inter-locking between (earth-switch / breaker / door), mimic diagram and indication lamps / flags complete all as specified and directed.Note :- (i) Necessary T & P for repair will be in the scope of contractor / own arrangement of the contractor. (ii) Spare part required for replacement shall be measured and paid for separately under supply only item in respective item of this schedule.(iii) Arranging power shutdown/outage with the Discom (to be coordinated through the consern JE E/M / Engineer-in-Charge). |
| 5 | Supply only item as follows: - (Component of VCB's & RMU ) (a) Vacuum Interrupter Bottle, 11kV, 630A (VCB pole unit) |
| 6 | VCB Spring-Charging / Operating Mechanism spares (springs, cams, bearings, linkages) |
| 7 | Trip Coil, DC 24/110/220V |
| 8 | Closing Coil, DC 24/110/220V |
| 9 | Auxiliary Switch / Contact Block (52a/52b) |
| 10 | HRC Fuse any capacity & Amps suitable for 11 KV RMU |
| 11 | Fixed & Moving Contact Assembly, per pole (set of 3 poles) |
| 12 | Epoxy/Insulating Bushing, per pole (RMU/VCB) |
| 13 | RMU Gasket & 'O'-ring Set (SF6/Vacuum type) |
| 14 | Load Break Switch (LBS) Contact & Arc-Chute Spares |
| 15 | SF6 Gas (Top up filling or complete filling in 11 KV RMU to Maintain the Pressure upto 0.3 bar to 0.5 bar as per requirment) |
| 16 | Multifunction Numerical Protection Relay (Handel IDMT Over Current Protection, Earth Fault, Over/Under Voltage protection & Differential, Digital Trip circuit supervision (TCS) 24 volt to 110 volt of any capacity, & Make |
| 17 | Master Trip Relay |
| 18 | Auxiliary Current Transformer (CT), 11kV class |
| 19 | Auxiliary Potential Transformer (PT), 11kV class |
| 20 | Float cum Boost charger (DC Battery Charger Panel) complete |
| 21 | Multicore Control Cable, 2.5 sqmm (for panel wiring) |
| 22 | Anti-Pumping Relay / 94 relay / Control relay for 11 KV VCB |
| 23 | Limit Switch for 11 KV VCB |
| 24 | Hold on catch assembly for 11KV VCB |
| 25 | Motor Rectifier Module (with heatsink & DIN rail mount) for 11KV VCB |
| 26 | Supply only Electrical Contact cleaner / anti rusting spray ( CRC-2-26) |
| 27 | Supply only Electrical Contact industrial grade cleaner spray ( 3M Cleaning Agent SCOTCH 1625/200) |
| 28 | Aluminium Space Heater ( Panel - Anti condensation Heater) of capacity 80 to100 operating voltage 110V AC/DC or 230 Volt for 11 KV VCB |
| 29 | HT Bushing any type for 11 KV, (Interface C (630A-Bolt-on/M16 or any interface) RMU |
| 30 | Spout Bushing 11 KV, (630A/1250A) VCB ( for Incoming / Out going ) |
| 31 | TNC Switch for 11 KV VCB |
| 32 | Annanunciator 6 to 8 window for 11 KV VCB |
| 33 | Emergency stop switch for 11 KV VCB |
| 34 | Hooter for 11 KV VCB |
| 35 | LED/Neon indicator Lamp (R,Y,B) (set of Three) |
| 36 | DC supply control unit / SMPS Unit complete |
| 37 | Sealed Maintenance Free (SMF) Battery of capacity (26 Ah to 42 Ah) and suitable for 24V / 30V /110V DC complete as per site requirement |
| 38 | Material & Labour for Repair & Comprehensive Maintenance of Distribution Transformer of capacity 63 KVA to 250 KVA after De-energising, isolating and earthing the transformer (HV & LV sides) and external visual inspection for oil leakage, rusting, bushing cracks including replacement complete gasket set (i.e.for tank cover, conservator, valves, cable box cover) to arrest leakage and cleaning/replacement of silica-gel breather and re-activation / replacement of silica gel including inspection & cleaning of HV & LV bushings / studs & replacement of any cracked/damaged bushing/studs and check the Tap-changer operation across all tap positions and contact-resistance verification including cleaning of radiator fins & conservator, and checking of oil-level gauge, transformer body & neutral earthing connections and continuity including replacement of aluminium Lugs of suitable size & MS cable box cover as per existing shape & size and then carry out Insulation Resistance (IR) / Polarisation Index test on the winding (HV-E, LV-E, HV-LV) complete all as specified and directed.Note :- (i) Necessary T & P for repair will be in the scope of contractor / own arrangement of the contractor. (ii) Spare part required like (bushing, Silca gel, rubberised cork, bushing rod, Transformer oil) for replacement shall be measured and paid for separately under respective item of this schedule.(iii) Arranging power shutdown/outage with the Discom (to be coordinated through the consern JE E/M / Engineer-in-Charge). |
| 39 | - ditto- all as per Item No 5 above but for 315 KVA to 500 KVA Transformer. |
| 40 | Taking down of transformers of capacity 63/100/160/250/315/400/500 KVA or any capacity from 2/4 Pole structure or from PCC platform with due care after disconnecting all HT/LT connections and transportation of Transformer to Local / Contractor workshop for repair including loading and unloading of transformer, and installed the same after return back from work shop, where it was taken with the help of crane/Hydra and reconnecting all the HT/LT electrical coneection and testing complete all as specefied and directed. |
| 41 | M& L for opening / spliting of defective indoor/outdoor transformer of any capacity both from HT/LT sides, and then drainage of complete transformer oil, opening of top cover with due care and removal of all HT/LT winding connections from bushing and then lifting of core by means of tripod and chain pulley with due care for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required repairs to the winding and core at the work shop for repairs. Note :- (i) The cost of rewinding shall be paid separately. (ii) The cost of dehydration/filtration & other necessary repair as directed shall be measured & paid separately under relevant items of this schedule. (iii) Additional transformer oil for top-up, if required will be filled by contractor and shall be paid under respective item of this schedule. |
| 42 | Material and labour for replacement of worn out HT side copper coils of Transformer rating 63-500 KVA made out of super enameled insulated copper wire all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed. |
| 43 | Material and labour for replacement of worn out LT side copper coils for Transformer rating rating 63-500 KVA made out of super enameled insulated copper strip all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed. |
| 44 | Material and labour for shifting of transformers of capacity 63/100/160/250/315/400/500 KVA or any capacity from 2/4pole structure or from PCC platform with due care after disconnecting all HT/LT connections on pole mounted structures, and installed the same at any new location of Ahmedabad cantt area including loading and unloading and lowering with the help of crane and reconnecting all the HT/LT electrical coneection and testing complete all as specefied and directed. |
| 45 | Dehydration/centrifuging of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer at 4mm gap the BDV should be 40KV complete all as specified and directed by engineer in charge.NOTE :- Contractor will arrange filtration machine/plant at site of transformer, dehydration of transformer oil will be carried out in working condition and electric supply for filtration will be taken from same transformer. |
| 46 | Supplying, filling dehydration and filtration of new transformer oil for toping up / Replacement of transformer oil having dielectric strength not less than 40 KV (rms) with gap of 2.5 mm all as conforming to IS complete all as specified and directed. |
| 47 | Material and labour for replacement of worn out bushing rod made out of brass with heavy duty three nuts and three washer at both ends suitable for HV side all as per existing size, shape, dia and length suitable for following capacity transformers :-(a) 63-200 KVA Transformer |
| 48 | 250 – 500 KVA Transformers. |
| 49 | Material and labour for replacement of worn out bushing rod made out of made out brass with heavy duty three nuts and three washer at both ends suitable for LV side all as exiting size, shape and length suitable for following capacity transformers :-(a) 63 - 200 KVA Transformers. |
| 50 | 250 – 500 KVA Transformers. |
| 51 | Material and labour for replacement of worn out porcelain bushing for 11KV HT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for following capacity transformers:-(a) 63-200 KVA Transformers |
| 52 | 250 – 500 KVA Transformers. |
| 53 | Material and labour for replacement of worn out porcelain bushing for .433 KV LT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for following capacity transformers:-(a) 63-200 KVA Transformers |
| 54 | 250 – 500 KVA Transformers. |
| 55 | Material and labour for replacement of worn out rubberised cork sheet 4mm thick for transformer top cover all as required at site and as directed by engineer in charge suitable for following capacity transformers:-(a) 63-200 KVA Transformers |
| 56 | 250 – 500 KVA Transformers. |
| 57 | Material and labour for replacement of worn out rubberised cork sheet 4mm thick suitable for HT/LT side bushing of off sizes all as required at site and directed. |
| 58 | Material and labour for Preparation of external surface of transformer for painting complete including fins / radiators / conservator by removal of all rust / oil / grease and unwanted material and then applying two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformer of following capacity complete all as specified and directed.(a) Upto 250 KVA |
| 59 | (b) 315-50 KVA |
| 60 | Material and labour for replacement of worn out silica gel breather assembly including silica gel all as per existing sample suitable for following capacity of transformers of any make.:-(a) 63-200 KVA Transformers |
| 61 | 250 – 500 KVA Transformers. |
| 62 | Material and labour for replacement of worn out off load tap changer, with matallic tap changing machanizm, 7 positions and making all electrical connection including removing existing one complete all as per existing sample suitable for following capacity of transformers of any make.:-63 - 200 KVA Transformers. |
| 63 | 250 – 500 KVA Transformers. |
| 64 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron with universal clamp made of SS earth enhancing compound shall be of 30kg/pit (resistivity is less than 0.12 Ohm meter).The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 4000 kg load bearing capacity complete all as specified and directed. |
| 65 | Material and labour for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays / strutus / floor or making basements etc complete all as specified and directed. |
| 66 | Material and labour for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping ( new and old damage coping) to poles / strutus etc complete all as specified and directed. |
| 67 | Material and labour Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required using 32x5mm galvanised iron strip complete with fixing arrangement on wall / foundation / passing through protection pipe complete all as specified and directed. |
| 68 | Supply and fixing Lithium ion battery of capacity 3 volt suitable for multifunction relay of VCB 11 KV complete all as specified and directed. Make : Panasonic model : CR123A or capacity equivalent mdel and capacity suitable for other VCB make relay. |
| 69 | S & F in replacement Terminal protector Boots suitable for 11 KV RMU (Right angle cable boot) complete with disconnecting the end terminals from RMU and re-fix to its original positation complete all as specified and directed. (Set of three) |
| 70 | Supply and fix vertical type air break gang operated Device of capacity 200 Amps, tripple pole, mechanically operated, outdoor type with all fittings, accessories, mounted on and including HT 11 KV porcelain insulators 09 Nos and steel channel frame, GI operating rod 25 mm dia of suitable length worked from ground including locking arrangements, with 7 livers Naval brass lock, complete all as specified and directed. (set of three) |
| 71 | Supply & fixing of replacement Current Transformer (CT) for 11kV VCB, Ratio 100-50/5+5A (Dual Ratio, Dual Core), Class of Accuracy 1.0, Burden 15VA on Core-1 & Core-2, Rated Insulation Level 12/28/75 kVp, Short-Time Current (STC) 18.4kA for 1 Sec, epoxy resin cast construction conforming to IS:2705, complete with dismantling of unserviceable CT and fixing of new CT in existing VCB arrangement, including all connections, testing & commissioning, complete all as specified and directed. ( Set of Three) |
| 72 | Supply & fixing of replacement Potential Transformer (PT), 11kV Oil/Dry type, Ratio & rating as per existing make and type, Class of Accuracy 3P/0.5 (as applicable), conforming to IS:3156, complete with dismantling of unserviceable PT and fixing of new PT in existing VCB/panel arrangement, including all connections, testing & commissioning, complete all as specified and directed. ( Set of Three) |
| 73 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for rerouting and finding of the HT/LT cable fault in underground cable and returning filling the same after rectification of the cable fault in any type of soil complete all as specified and directed.Note : 1. New HDPE Pipe of suitable size to be wraped over the cable at repair portion for protection approx 2 Mtr. |
| 74 | Material and labour for findout fault in High Tension (HT)/Low Tension (LT) underground power cable using cable Fault Locating Equipment / Machine (comprising Surge Generator and Pin-Pointer Fault Detector) complete after disconnection of HT/LT cable from both end terminations at sending & Receiving ends and pin-pointing of exact fault location on the cable route by surge/acoustic-magnetic method mobilization of fault-locating van/machine and skilled testing crew to site with all test leads, connectors complete all as specified and directed. |
| 75 | Material and labour for servicing of two & four pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI PG clamps 'T' connector run through clamps, bolts nuts, washer connecting lugs/thimbles knife contacts applying petroleum jelly to the moving contact as well fixed contacts, tightening all the connection for its smooth functioning all as specified and directed. Note :- No extra payment will be made for the spares required to keep the two & four pole structure in satisfactory functioning throughout contract period other than given in schedule complete all as specified and directed.. |
| 76 | Material and labour for cement concrete 1:3:6 type C-2 using 40 mm graded aggregate as in foundation and for PCC flooring at different 11 KV sub station as per site requirment and necessary form work complete all as specified and directed. |
| 77 | Dismentaling of old steel tubular pole LT/HT after excavation of PCC and disconecting of cross arm and insulators,and shifting it to new location as per site required including all ACSR conductor any size / cross arm / insulators connections including installed at site after necessary excavation PCC foundation work and coping complete all as specified and directed. Note :- Excavation , PCC foundation work and coping for installation of new location shall be measured and paid seperately under respective item of schedule. |
| 78 | Material and labour for Cutting through existing bituminous road / PCC / floor / approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing / RCC / HDPE pipe for encasing of UG cable and repairing the road to match with the original finish by PCC 1:3:6 type C-2 using 40mm graded aggrigate complete all as specified and directed. |
| 79 | Supply, installation, assembly, testing & commissioning of Vacuum Circuit Breaker (VCB) Panel/Switchgear, 11kV, 3-Phase, 50Hz, 630A, CRCA sheet steel enclosure, powder-coated finish (Admiral Grey/RAL 7032, with the following minimum specification: Indoor, floor mounted, free-standing, single-front, metal-clad construction as per IEC 62271-100 & IEC 62271-200 / IS:13118 & IS:3427; Rated voltage 12kV; Rated normal current 630A (busbar & breaker); Rated short-time withstand current 25kA for 3 Sec; Rated peak withstand current 63kA; Power frequency withstand voltage 28kV (1 min); Impulse withstand voltage (1.2/50µs) 75kV; Vacuum interrupter type breaker with spring-charged, motor-wound stored-energy operating mechanism; Horizontal drawout breaker truck with three distinct positions service / test / Isolated complete with mechanical & electrical interlocks, automatic safety shutters and earthing switch; Degree of protection IP4X (enclosure) / IP2X (after door open); Internal arc classification IAC-AFLR, 25kA for 1 Sec; Electrolytic copper, insulated & colour-coded busbar rated to match panel current; Metering & protection class CT/PT as per feeder requirement; Numerical multifunction protection relay (O/C, E/F etc.) with local mimic, indication lamps, control switches and meters; Control voltage 110V DC / 240V AC (as applicable) for spring charging motor, trip & close coils; Cable compartment suitable for 3-Core HT XLPE cable termination (bottom/top entry) with cable box, breaker truck, CT/PT, IDMT relays, Master trip relay, Transformer fault relay, Hooter, TNC switch, meters & control wiring including transportation to site and fixing positioning, on suitable size of PCC/Brick foundation and carried out pre-commissioning tests (IR, HV, contact resistance, timing, relay injection & functional interlock tests) and taking out and deposit the old unserviceable VCB in AGE E/M store complete as specified and directed.Make : Siemens / ABB / Cromption / Schneider Electric |
| 80 | Material and labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long and diameter of neck 10mm complete all as specified and directed. |
| 81 | Supply and spreading graded coarse aggregate of size 40 mm at electrical outdoor installation yard 11 KV Substations/ Near Two/Four Pole structures etc including leveling of uneven surface, removing vegetation, grass etc complete all as specified and directed. |
| 82 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 120 Sqmm 3 core including taking out old unserviceable HT cable complete all as specified and directed. |
| 83 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 95 Sqmm 3 core including taking out old unserviceable HT cable complete all as specified and directed. |
| 84 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of cable /pipes and for poles/stay/ struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified. |
| 85 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed. |
| 86 | Removing surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed. |
| 87 | Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed.(Note: Thickness after punning shall be measured for payment ) |
| 88 | Supply and laying unreinforced precast concrete cable cover, class HVP, type- 1 with peak, size 300mmx180mmx40mm laid flat adjacent and abutting to each other across the length of cable laid dry complete all as specified & directed. |
| 89 | S&F cable jointing kit 11 KV (earthed) grade cable for straight through termination (Heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 - 185sqmm complete all as specified and directed. |
| 90 | - ditto- all as per Item No- 47 above but of size 3 core 95 Sqmm. |
| 91 | Supply and fixing of cable jointing kit 11 KV (earthed) grade cable for indoor Terminal with long sleeves (Heat shinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm sqmm complete all as specified and directed. |
| 92 | - ditto- all as per Item No- 49 above but of size 3 core 95 Sqmm. |
| 93 | Supply and fixing of cable jointing kit 11 KV (earthed) grade cable for Out door Termination (heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120Sqmm to 185 Sqmm complete all as specified and directed. |
| 94 | - ditto- all as per Item No- 51 above but of size 3 core 95 Sqmm. |
| 95 | Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 KV for electrical purpose as per IS suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
| 96 | Material and labour for Cable route marker made out of CI plate, indication cable size, supply voltage, welded to 40mmx40mmx6mm angle iron bent to shape as directed. The height of the route marker above ground level shall be 300mm, and grouted in PCC (1:2:4) using 20 mm graded agggregate of size 303(H)x200(L)x200(W)mm complete all as specified and directed. |
| 97 | S&F in replacement of unserviceable lightning arrestors with new 11 KV Lightning arrestors explusion type complete with all fittings and necessary connection,transmission class, discharge capcity 65 kilo amps complete all as specified. (Set of three) |
| 98 | Material and labour in replacement of unserviceable cross arms with new cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including removing of existing any type of conductor a coat of red oxide primer one underand & one finishing coat complete all as specified and directed. |
| 99 | Supply and fix in replacement of drop out fuse unit explusion type for out door air break gang oprated switch single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts, and washer etc. synthetic bounded fuse camng tube complete with line fap suitable for current carry capcity upto 200 Amps complete as secified and directed. (Set of Three) |
| 100 | Supplying, install and errect in true vertical position steel tubular swaged welded pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-55 (11.0 metre long) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal yeliow colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height complete all as specified and directed. (Note: (1) Excavation and PCC works will be measured and paid separatly in respected items.(2) Cost of dismantling existing damaged PCC pole is deemed to be included in the quoted rate. |
| 101 | Material and labour in repalcement of aluminium conductor, steel reinforced (ASCR weizel) off sizes including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed. |
| 102 | Supply and fixing danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender