Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #58238172

Tender For Repairs To Roofs, Chajjas, Sunken Portions And Allied Building Components Including Treatment Of Leakage ,Seepage, D Ness And Surface Deterioration At Domestic Area At Afs Tambaram.(8969/E8)

Issued by Statutory Bodies & Commissions/Committees · Chengalpattu, Tamil Nadu
Tender Value
25 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs To Roofs, Chajjas, Sunken Portions And Allied Building Components Including Treatment Of Leakage ,Seepage, D Ness And Surface Deterioration At Domestic Area At Afs Tambaram.(8969/E8)

BOQ

Name of Work:- REPAIRS TO ROOFS, CHAJJAS, SUNKEN PORTIONS AND ALLIED BUILDING COMPONENTS INCLUDING TREATMENT OF LEAKAGE ,SEEPAGE, D NESS AND SURFACE DETERIORATION AT DOMESTIC AREA AT AFS TAMBARAM.(8969/E8)
Sl. No. Item Description
1Demolition of cement concrete (unreinforced) in roofs, fioors(other than ground floors) beams,staircases, landing, chajjas and similar suspended works complete all as specified and directed by Engineer-in-Charge.
2Dismantling of any type of roof treatment incl roof tiles of any description and cement mortar over roof slab up to G+2 storey building and cleaning of surface with wire brushes removing of unsolvent materials, any cementious residue and depositing of the same as directed at a distance n.exc 500m complete all as specified and directed by Engineer-in-Charge.
3M&L 15mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth with out using extra cement mixed with WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement etc complete all as specified and directed by Engineer-in-Charge.Note;- WPC shall be measured and paid seperately.
4Cleaning the surface and removing the dust particles by using mechanical or manual tools and attending the cracks , holes like as weak points by using manufactures instruction .Providing and Laying polymer concrete by adding crystalline internal membrane admixtures by the ratio of (1 bag cement = 500gms crystalline admixtures ) making hunch surface 100mm x 100mm of floor & wall joint area. The surface to be cleaned free from oil grease,wax,dust and other barrier materials.The entire area applied primer as a base layer and over the top placing Fiber mesh & applied entire floor & around wall 1 ft area two coats of water based, UV resistant Elastomeric PU liquid membrane waterproofing coating with required time intervals by using brand ShaliUrethane-BTD.Dilute ShaliUrethane® BTD with water @ 1:1 ratio and use as primer @ 400 gm / m².Apply 1st coat of ShaliUrethane® BTD @ 1 kg (or 0.8 kg) / m² by brush / roller / airless spray while the primed surface is tacky. For faster and smoother application , apply with airless gun. Spread Non-woven Geo-textile fabric or Fiber Glass Tissue / scrimp of 45 GSM with SBR bonding applicationwith overlaps of 50 mm in both directions when the surface is still tacky; this is optional, to be assessed as per site requirements to achieve higher mechanical properties. Apply 2nd coat of ShaliUrethane® BTD @ 1 kg (or 0.8 kg) / m² by brush / roller / airless spray for final DFT of 1200 micron in two coats (for 1000 microns DFT apply 0.825 kg / m² / coat) complete all as specified and directed by Engineer-in-Charge.
5Disconnecting of existing PVC tanks for repairs to roof and reconnect, refixing in position for 500/1000 ltrs capacity tanks complete all as specified and directed by Engineer-in-Charge.
6Taking down Cement Plaster, up to height of Bldg G+2 Level, any description on Brick Walls or on Concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc, and removing same from the Site(s), complete all as specified and directed by Engineer-in-Charge. NOTE : Rates for scafolding are included in the item.
7M&L for rendering up to height of Bldg G+2 level on fair faces on wall surfaces 15 mm thick in cement mortar 1:4 mixed with water proofing compound at the rate of 200 ML per bag of cement, finished fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge.NOTE : Rates for scafolding are included in the item.Water proofing compound shall be measured and paid separately under relevent item
8Taking up or down 15 mm dia steel tubing and connections,including cleaning for refixing or removal to store in wall, ceiling or floor etc complete all as specified and directed by Engineer-in-Charge.
9All as item No 8 above but 20 mm dia of pipe complete all as specified and directed by Engineer-in-Charge.
10Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
11All as per item above but for bore dia 25 mm complete all as specified and directed by Engineer-in-Charge.
12Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge. Make : DrFixit/SIKA/Forsoc
13M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer-in-Charge.Make: Asian/Berger/Narolac
14S&F PVC (SWR) Soil, Waste and Vent Pipe 75mm bore (dia), Single Socketed, in any length with Rubber Ring Joint fixed to Wall or Laid in Trenches etc., including Taking down/up unserviceable Pipe, complete all as specified and directed by Engineer-in-Charge.
15All as per Item above but for 110mm bore (dia) complete all as specified and directed by Engineer-in-Charge.
16PVC (SWR) 75mm bore (dia), Bends, any radius with access door and Jointing with Solvent Cement and fixed-in-repairs, complete all as specified and directed by Engineer-in-Charge.
17All as per Item above but for 110mm bore (dia) complete all as specified and directed by Engineer-in-Charge.
18PVC (SWR) 75mm Bore (dia), Branch Piece, Single (Single Y) Equal or Unequal with access door and Jointing with Solvent Cement and fixed-in-repairs, complete all as specified and directed by Engineer-in-Charge.
19All as per Item above but for 110mm bore (dia) complete all as specified and directed by Engineer-in-Charge.
20PVC (SWR) 75mm Bore (dia), junction Single (Single T) Equal or Unequal with access door and Jointing with Solvent Cement and fixed-in-repairs, complete all as specified and directed by Engineer-in-Charge.
21All as per Item above but for 110mm bore (dia) complete all as specified and directed by Engineer-in-Charge.
22S & F PVC (SWR) vent cowl, size of bore 75mm complete all as specified and directed by Engineer-in-Charge.
23S & F PVC (SWR) vent cowl, size of bore 110mm complete all as specified and directed by Engineer-in-Charge.
24M&L for PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation filling and mass concrete (sunken floors etc.) complete all as specified and directed by Engineer-in-Charge.
25M&L for Rendering 15mm thick on brick work or concrete surfaces in CM 1:4 with and including water proofing compound to sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement including application of 90 micron polythene film and applying bitumen coating @ 3.00 Kg/Sqm complete all as specified and directed by Engineer-in-Charge.
26M&L for Rendering 5 mm thick in Cement Mortar 1:3 on concrete surfaces on ceiling finished Even and Smooth without using Extra Cement complete all as specified and directed by Engineer-in-Charge.
27S&F Rotational moulded polyethlene water storage tanks of capacity 500 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including suitable tank nipple and 20mm dia ball brass valve high pressure with polythene float and dismantling of existing RCC/ PVC tank of any capacity complete all as specified and directed by Engineer-in-Charge.
28All as per item no.27 but capacity 750 ltr of water storage tank complete all as specified and directed by Engineer-in-Charge.
29S&F Ball valves 20 mm dia fixed in repair, high pressure of PTMT, with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.(Minimum weight -455gms)
30M&L for pressure gunniting/shot creting for ,ceilings of building surfaces any size and any height of staging by using mechanical means and necessary scaffolding complete all as specified and directed by Engineer-in-Charge. :-Notes:-Stages for gunniting/shot creating ceiling surfaces:-(a) Dismantling/taking down loose /spalling /unsound cement concrete and plaster layers average depth upto 25mm from the surface and disposed up unserviceable debris and rubbish outside MD land.(b) Preparation of exposed reinforcement (i.e. including cutting of all edges, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale / rust etc from visible reinforcement by applying rust remover Reebaklens RR (3-4 Sqm per litre) or epoxy coated bonding agent or equivalent of Chemco system / Webac chemical and trimming cleaning the steel reinforcement properly) of roof/beam/columns surfaces.(c) Applying two Coats to the exposed reinforcement by ReArm Coat- Zp or equivalent of Chemco system / Webac chemicals on visible reinforcement surfaces to form a continious dry film not less than 80 micron thick a reinforcement epoxy.(d) Gunniting/Shotcrete the damaged portion of the inside surface of the roof with cement mortar mixed with Aqua Arm bond latex and then plastering.
31M&L for pressure gunniting/shot creting for roof/beams ,chajjas and water proofing by Epoxy coating of any size and any height of staging by using mechanical means and necessary scaffolding complete all as specified and directed by Engineer-in-Charge. :-Notes:-Stages for gunniting/shot creating roof/beam surfaces:-(a) Dismantling/taking down loose /spalling /unsound cement concrete layers average depth 25mm from the roof and disposed up unserviceable debris and rubbish outside MD land.(b) Preparation of exposed reinforcement (i.e. including cutting of all edges, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale / rust etc from visible reinforcement by applying rust remover Reebaklens RR (3-4 Sqm per litre) or epoxy coated bonding agent or equivalent of Chemco system / Webac chemical and trimming cleaning the steel reinforcement properly) of roof/beam/columns surfaces.(c) Applying two Coats to the exposed reinforcement by ReArm Coat- Zp or equivalent of Chemco system / Webac chemicals on visible reinforcement surfaces to form a continious dry film not less than 80 micron thick a reinforcement epoxy.(d) Gunniting/Shotcrete the damaged portion of the inside surface of the roof with cement mortar mixed with Aqua Arm bond latex and then plastering.
32S&F:- Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia securing with clips complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
33S&F:- Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia securing with clips complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58238172
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs To Roofs, Chajjas, Sunken Portions And Allied Building Components Including Treatment Of Leakage ,Seepage, D Ness And Surface Deterioration At Domestic Area At Afs Tambaram.(8969/E8)
Basic Detail
Tender No GE(AF)/TBM/8969/E8
Bidding Type Tender
Location
City Chengalpattu
State Tamil Nadu
Key Dates
Publish Date 27 Oct 2026
Submission Date 17 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
29a3c22c-8c44-462c-9945-eb7782d7fdb3.html
BOQ_892624.xls
PS.pdf
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

29a3c22c-8c44-462c-9945-eb7782d7fdb3.html

xls

BOQ_892624.xls

pdf

PS.pdf

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer