Tender For annual repair maintenance Electrical Work To Internal And External Installation At Fsd Jasidih Under Do Deoghar For Fy 2026-27.
Tender Value
4.27 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
3 days left
EMD
8550
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Deoghar → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual repair maintenance Electrical Work To Internal And External Installation At Fsd Jasidih Under Do Deoghar For Fy 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 5 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 7 | 8 way , Double door |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | Single pole |
| 10 | Single pole and neutral |
| 11 | Triple pole and neutral |
| 12 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | 20 mm |
| 14 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.. |
| 15 | 3 x 1.5 sq. mm |
| 16 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted atten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), DCM(Standard Deviation Colour Matching) <3, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 17 | 18- 22 Watt |
| 18 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining ccessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), nsulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor ingle core cable and earthing etc. as required. |
| 19 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 20 | 45 watt |
| 21 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c+external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 22 | 50 watt |
| 23 | Supplying and Installation of heavy duty exhaust fan of 230 mm sweep with louvers & shutter in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 24 | Supplying, installation, Testing and commissioning of 70 Watt LED type Well Glass luminaires in pressure die-cast aluminium housing with IP 66,IK 07,LEDs with lumen efficacy of ≥ 120 lm/W, System efficacy of ≥ 110 lm/W,colour temp 5700 K,THD( %) ≤ 10, Polycarbonate diffuser in opal finish and fixing on truss /wall/ pole with suitable clamps and nut bolts and also dismantling the existing fitting etc at the site of work as required. |
| 25 | Supplying of aluminium conductor PVC insulated, PVC sheathed/ XLPE insulated inner sheathed steel strip armoured power cable of 1.1 KV grade conforming to IS:7098(Part-I) 1988 or latest amended following sizes etc . |
| 26 | 2X6 sqmm armoured |
| 27 | 4X10 sqmm armoured |
| 28 | 4X35 sqmm armoured |
| 29 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 30 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 31 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 32 | 2x6 sq mm (19 mm) |
| 33 | 4 X 10 sq. mm (25mm) |
| 34 | 4 X 16 sq. mm (28mm) |
| 35 | 4x35 sq mm (32 mm) |
| 36 | Supplying and fixing of Hot pressed moulded SMC Junction box of size 195mm x 135mm x 90mm with 4 way Strip connector 63A etc. as required at the site of work. |
| 37 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 38 | Dismantling of butnt porcelain kit-kat fuse sets with disconnetion of cable ends, supplyying and fixing 3 Nos 200 A porcelain kit-kat fuse sets, connection of incoming and outgoing cable conductors with socketting etc. as required as per direction of Engineer-in-charge. |
| 39 | Dismantling of all incoming and outgoing cables connection (outgoing- 4 Nos. FP MCBs, 1 No. DP MCB and incoming- 1 No. FP MCCB) in the existing Feeder Pillar Box, supplying and fixing 4 Nos. 100A Aluminium busbar of 200mm in length with 8 Nos. porcelain base on the existing MS chanel of the Feeder Pillar Box, connection with Existing one no. FP MCCB, 4 Nos. FP MCB & one No. DP MCB with new 6sqmm FRLS PVC insulated copper conductor cable cords of suitable length from busbar to FP MCBs and from FP MCCB to Busbar & also connecting with suitable sockets, dressing the cable/ wires, supplying & fixing 3 Nos. LED indicator lamps etc. as required as per direction of Engineer-in-charge. |
| 40 | Dismantling of all incoming and outgoing cables & wire connection including all MCCBs,MCB,Changeover,HD Connector, etc of the main LT Panel and suppliyng and fixing following itemsi) digital ammeter + digital Voltmeter= (1+1) no.ii) FP MCCB with thermomagnetic release and terminal spreaders- 100A, 36 KA, Ics=100%= 1 nos. Iii) 63A TPN MCB = 2 nos.iv) 32A DP = 1 nos.connection of all new and existing MCCBs & MCB with 6 sqmm PVC insulated FRLS copper conductor cable cords of suitable length from busbar & also connecting with suitable sockets dressing the cable/ wires, supplying & fixing 3 Nos. LED indicator lamps etc. as required as per direction of Engineer-in-charge. |
| 41 | Lowering of lantern carriage of 16.00 M high mast using motor-driven tools and resting it on the stay stud of the high mast. Providing & changing 32 meter 5 core 2.5 sqmm copper armoured cable trailing cable along with checking and testing of LED fittings and associated wiring. . After completion of repair and replacement, hoisting of the lantern carriage of the 16.00 M high mast by means of motor-driven tools, followed by commissioning of the high mast system as per the direction of the Engineer-in-Charge. |
| 42 | Providing and fixing insulating Rubber Mat of 6 mm thick of size 1 mtr x 2 Mtr (Widht X Length) on the the floor as per the direction of the Engineer-in-Charge. |
| 43 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 44 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 45 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender