Agriculture Boards / Undertakings / PSU Closing in 3 days TDR #58237468

Tender For annual repair maintenance Electrical Work To Internal And External Installation At Fsd Jasidih Under Do Deoghar For Fy 2026-27.

Issued by Boards / Undertakings / PSU · Deoghar, Jharkhand
Tender Value
4.27 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
3 days left
EMD
8550
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Deoghar → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for annual repair maintenance Electrical Work To Internal And External Installation At Fsd Jasidih Under Do Deoghar For Fy 2026-27.

BOQ

Name of Work:- ARMO electrical work to internal and external installation at FSD Jasidih under DO Deoghar for FY 2026-27.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Group C
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
42 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
5Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
6Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
78 way , Double door
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9Single pole
10Single pole and neutral
11Triple pole and neutral
12Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1320 mm
14Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required..
153 x 1.5 sq. mm
16LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted atten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), DCM(Standard Deviation Colour Matching) <3, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
1718- 22 Watt
18Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining ccessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), nsulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor ingle core cable and earthing etc. as required.
19LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2045 watt
21LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c+external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2250 watt
23Supplying and Installation of heavy duty exhaust fan of 230 mm sweep with louvers & shutter in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
24Supplying, installation, Testing and commissioning of 70 Watt LED type Well Glass luminaires in pressure die-cast aluminium housing with IP 66,IK 07,LEDs with lumen efficacy of ≥ 120 lm/W, System efficacy of ≥ 110 lm/W,colour temp 5700 K,THD( %) ≤ 10, Polycarbonate diffuser in opal finish and fixing on truss /wall/ pole with suitable clamps and nut bolts and also dismantling the existing fitting etc at the site of work as required.
25Supplying of aluminium conductor PVC insulated, PVC sheathed/ XLPE insulated inner sheathed steel strip armoured power cable of 1.1 KV grade conforming to IS:7098(Part-I) 1988 or latest amended following sizes etc .
262X6 sqmm armoured
274X10 sqmm armoured
284X35 sqmm armoured
29Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
30Upto 35 sq. mm (clamped with 1mm thick saddle)
31Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
322x6 sq mm (19 mm)
334 X 10 sq. mm (25mm)
344 X 16 sq. mm (28mm)
354x35 sq mm (32 mm)
36Supplying and fixing of Hot pressed moulded SMC Junction box of size 195mm x 135mm x 90mm with 4 way Strip connector 63A etc. as required at the site of work.
37Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
38Dismantling of butnt porcelain kit-kat fuse sets with disconnetion of cable ends, supplyying and fixing 3 Nos 200 A porcelain kit-kat fuse sets, connection of incoming and outgoing cable conductors with socketting etc. as required as per direction of Engineer-in-charge.
39Dismantling of all incoming and outgoing cables connection (outgoing- 4 Nos. FP MCBs, 1 No. DP MCB and incoming- 1 No. FP MCCB) in the existing Feeder Pillar Box, supplying and fixing 4 Nos. 100A Aluminium busbar of 200mm in length with 8 Nos. porcelain base on the existing MS chanel of the Feeder Pillar Box, connection with Existing one no. FP MCCB, 4 Nos. FP MCB & one No. DP MCB with new 6sqmm FRLS PVC insulated copper conductor cable cords of suitable length from busbar to FP MCBs and from FP MCCB to Busbar & also connecting with suitable sockets, dressing the cable/ wires, supplying & fixing 3 Nos. LED indicator lamps etc. as required as per direction of Engineer-in-charge.
40Dismantling of all incoming and outgoing cables & wire connection including all MCCBs,MCB,Changeover,HD Connector, etc of the main LT Panel and suppliyng and fixing following itemsi) digital ammeter + digital Voltmeter= (1+1) no.ii) FP MCCB with thermomagnetic release and terminal spreaders- 100A, 36 KA, Ics=100%= 1 nos. Iii) 63A TPN MCB = 2 nos.iv) 32A DP = 1 nos.connection of all new and existing MCCBs & MCB with 6 sqmm PVC insulated FRLS copper conductor cable cords of suitable length from busbar & also connecting with suitable sockets dressing the cable/ wires, supplying & fixing 3 Nos. LED indicator lamps etc. as required as per direction of Engineer-in-charge.
41Lowering of lantern carriage of 16.00 M high mast using motor-driven tools and resting it on the stay stud of the high mast. Providing & changing 32 meter 5 core 2.5 sqmm copper armoured cable trailing cable along with checking and testing of LED fittings and associated wiring. . After completion of repair and replacement, hoisting of the lantern carriage of the 16.00 M high mast by means of motor-driven tools, followed by commissioning of the high mast system as per the direction of the Engineer-in-Charge.
42Providing and fixing insulating Rubber Mat of 6 mm thick of size 1 mtr x 2 Mtr (Widht X Length) on the the floor as per the direction of the Engineer-in-Charge.
43Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
44Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
45Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58237468
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 4.27 Lakhs
LAST DATE 07-11-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for annual repair maintenance Electrical Work To Internal And External Installation At Fsd Jasidih Under Do Deoghar For Fy 2026-27.
Basic Detail
Tender No 02/EM/JH/2026-27
Bidding Type Tender
Location
City Deoghar
State Jharkhand
Key Dates
Publish Date 28 Oct 2026
Submission Date 07 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 4.27 Lakhs
Tender Fee Ref. Documents
EMD 8550
Exemption Not Available
Document List
447337ef-0fe2-4a35-9835-81f627618d7d.html
BOQ_979401.xls
DNIT_Jasidih.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

447337ef-0fe2-4a35-9835-81f627618d7d.html

xls

BOQ_979401.xls

pdf

DNIT_Jasidih.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender