Tender For maintenance of Various Sports Complex.Sub Head : Supply, Replacement And Maintenance Of Irrigation System, Pole I/C Foundation, Pump And Wiring Accessories At Saket Sports Complex.
Tender Overview
Project Description
Tender for maintenance of Various Sports Complex.Sub Head : Supply, Replacement And Maintenance Of Irrigation System, Pole I/C Foundation, Pump And Wiring Accessories At Saket Sports Complex.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-Oct-2026 | Corrigendum1 | Other | 03-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and replacement of Large Radius Pop up Sprinkler with Gear driven mechanism having 2” female inlet, dia of coverage 84.0 m at 6.0 bar, capable of delivering discharge 15.6 lps and trajectory of throw 25°. It has feature of internal rubber folding cap so as to avoid passage of powder, sand and dirty water including testing, commissioning etc. as required. |
| 2 | Supply and replacement of 2\\" pop up connecting assembly made of high density plastic suitable for working pressure of 8.0 bar. |
| 3 | Supply and replacement of Valve box with cover on all valves. The valve boxes shall be heavy duty plastic with poly vinyl chloride reinforce and green top. Rain Spa (Italy) make 12\\" rectangular valve box. |
| 4 | Supply and replacement of 2\\" brass QCV with 2\\" male x 1.5\\" female brass key along with 2\\" x 2\\" swivel elbow. |
| 5 | Supply and replacement of Gear Driven Pop up Sprinkler with ABS (Acrylonitrile Butadiene Styrene) Riser with 3/4\\" inlet, 5\\" Riser, capable of delivering 1.7–3.6 lpm with radius of coverage from 7.9–14.9 m at pressure 2.0–5.0 Kg/cm² with trajectory of throw 26°, having top graduated arc adjustment, arc memory clutch, reversing mechanism, arc recall, full & part circle adjustment in 1°, heavy duty rubber cover which seals out dirt and increases product durability, and check valve. |
| 6 | Supply and replacement of Swing Joint 3/4\\" etc. as complete as required. |
| 7 | Supply and replacement of u-PVC pipe conforming to IS-4985:2000 with all fittings and accessories like coupling, tees, bends, reducer, screwed adopter, flanged tail piece etc.; jointing including earth work in excavation and refilling (earth work includes 450 mm soil cover over the pipe and width of 300 mm) of following size:-90 mm, 10 kg/cm². |
| 8 | 75 mm, 10 kg/cm². |
| 9 | 63 mm, 6 kg/cm². |
| 10 | 50 mm, 6 kg/cm². |
| 11 | 40 mm, 6 kg/cm². |
| 12 | Supply and replacement of Gear Driven Pop up Sprinkler with ABS (Acrylonitrile Butadiene Styrene) Riser with 1\\" inlet, 4\\" Riser, capable of delivering 19.3–110.5 lpm with radius of coverage from 13.7–21.6 m at pressure 2.7–6.2 Kg/cm² with trajectory of throw 26°, having top graduated arc adjustment, arc memory clutch, reversing mechanism, arc recall, full & part circle adjustment in 1°, heavy duty rubber cover which seals out dirt and increases product durability, and check valve. |
| 13 | Supply and replacement of Swing Joint 1\\" complete etc. as required. |
| 14 | Supplying installation of three phase dewatering/waste disposer submersible pump set of 80 mm DEL, 5500 CW, impeller CI, motor body CI, pump housing CI, shaft SS(CW+), CS(SW), IP 44, F class, rating 7.5 HP/5 kW including Testing and Commissioning etc. complete as required. |
| 15 | Supply, installation testing & commissioning of LT weather proof dust and vermin proof, outdoor panel with double door and IP 54 protection, fabricated out of suitable sized angle iron and flats and covered with 2mm thick CRCA sheet steel including canopy, duly stove enamel painted, both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports including PCC 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) foundation. The feeder pillars shall be complete with 3 phase and neutral bus bars of capacities as described below. Incoming125 FP MCCB, ics=25 KA with T.M RLS for O/L+S/C – 1 No. BUSBAR:150 Amp. Al. Bus BarOutgoing32A TP MCB, ics =10 KA -3 Nos.18 Amp TP Power Contrator- 06 Nos.9-15A OVER LOAD RELAY- 02 Nos.ADD ON BLOCK 1NO+1NC-06 Nos.SINGLE PHASING PREVENTER-02 Nos..ON DELAY TIMER DIGITAL SINGLE PHASE AMMETER-02 Nos.AUTO/MANUAL SELECTOR SWITCH-02 Nos. ON, OFF INDICATION LAMP-04 Nos.START, STOP PUSH BUTTON- 04 Nos.CT 60/5A CLASS-1-02 NosPhase indicator RED-1 Nos.YELLOW-1 No.BLUE-1 No. |
| 16 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/Class-II of IS:3589 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (DSR-2025-27.7.10)250 mm dia (wall thickness 6.3 mm). |
| 17 | 100 mm dia. |
| 18 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked, complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required. (DSR-2025-27.12.5)100 mm dia. |
| 19 | Supplying, installation, testing and commissioning of fixing of 100 mm dia. Gun metal horizontal non-return valve (screwed type) on the existing pipeline, including testing & commissioning etc. complete as required. (DSR-2025-20.21.1) |
| 20 | Supplying and replacement of existing old tubular pole by hot dip galvanized octagonal steel pole of 10 m height made out of 3 mm thick sheet having bottom 210 mm A/F & top 90 mm A/F with built-in connector control box with flush cover at height of 1000 mm from bottom of pole, PCD 320 mm, MS base plate 320 mm x 320 mm x 20 mm thick with 250 mm strip in octagonal shape (anti-theft arrangement). Pole to be fixed on existing RCC foundation with bolts and nuts, making connection/interconnection with thimble/lugs in connector box, earthing, making/numbering of pole etc., with mounted built-in control box: (a) 6 mm thick laminated sheet with 2 nos. 6 Amp, 10KA, SPMCB, “C” characteristic on DIN channel, 2 nos. 63 Amp terminal block suitable for 25 sq.mm aluminium conductor cable and DIN channel for MCBs; (b) earth stud welded at suitable height including washer, spring washers and nuts; (c) cable support clamps suitable for 2 nos. of 2 x 16 sq.mm cable; (d) hot dipped galvanized channel type bracket suitable for mounting up to 4 nos. fixture lightings with nut bolt and suitable canopy; (e) drawing of pole and bracket to be approved by Engineer-in-Charge as per manufacturer before use at site (rate inclusive of rebate of cost). |
| 21 | Providing and laying in position M20 (1:2:4) reinforced cement concrete foundation of size 500 mm long x 500 mm wide and 1600 mm deep including excavation of earth, cutting, bending and placing reinforcement of cold twisted bar of 12 mm dia 1650 mm long (approx.) – 8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.) – 10 Nos. (with 150 mm spacing), including supplying of 4 Nos. M-24 x 750 mm long (150 mm top threaded portion) GI foundation bolt (EN-8 grade) with 3 Nos. nuts and 2 Nos. washers, bolts along with 2 Nos. templates/anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 26 mm dia holes to match with PCD of pole base plate, positioning of foundation bolts and providing 63 mm (OD) 2 Nos. DWC pipe for cable entry and exit as required. Drawing to be approved by Engineer-in-Charge. |
| 22 | Supplying and replacement of existing old tubular pole by hot dip galvanized octagonal steel pole of 3 m height including dismantling of existing old/rusted pole, made out of 3 mm thick sheet having bottom 130 mm A/F & top 70 mm A/F with built-in connector control box with flush cover at height of 500 mm from bottom of pole (with anti-theft arrangement of cover), MS base plate 200 mm x 200 mm x 12 mm thick, pole fixed on existing RCC foundation with bolts and nuts making connection/interconnection with thimble/lugs in connector box, earthing, making/numbering of pole etc., with mounted built-in control box: (a) 6 mm thick laminated sheet with 2 nos. 5 A to 32 Amp, 10KA, SPMCB, “C” characteristic on DIN channel, 2 nos. 63 Amp terminal block suitable for 16 sq.mm aluminium conductor cable and DIN channel for MCBs; (b) earth stud welded at suitable height including washer, spring washers and nuts; (c) cable support clamps suitable for 2 nos. of 2 x 10 sq.mm cable; (d) galvanized steel 1 mtr single arm bracket made out of suitable dia pipe with canopy suitable as required and suitable for LED fitting etc.; (e) drawing of pole to be approved by Engineer-in-Charge as per manufacturer before use at site (including rebate of cost). |
| 23 | Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 300 mm long x 300 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1600 mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1600 mm long (approx.)-8 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-16 x 450 mm long (100 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 200 mm x 200 mm x 3 mm thick having 4 Nos. suitable mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.) |
| 24 | Supplying of XLPE insulated aluminium conductor having stranded wire armoured power cable of 1.1 KV grade including making, connection, testing etc.a) 3.5 core 35 sq.mm. |
| 25 | b) 2 core 10 sq.mm. |
| 26 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. (DSR-2025) — 3 x 1.5 sq.mm. |
| 27 | Supplying of ISI marked PVC conduit of following size — 25 mm dia. |
| 28 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc., conforming to IS 14930, Part II, complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (DSR 2025) — 63 mm dia (OD 63 mm & ID 51 mm nominal). |
| 29 | Supply, boring and laying of HDPE pipe (ISI) marked of 90 mm OD size conforming to IS:4984 with pressure rating of 6 KG/Sq.cm by trenchless technology with no-dig method by making bore hole in horizontal direction across the road with boring equipment including jointing, cleaning, rodding of pipe, performing mandrel test, providing suitable covers on mouth of pipes, excavation of pits of required size & depth and laying of cables in the pipe etc. complete as required. |
| 30 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. (DSR-2025-10.6.1) — a) Up to 35 sq.mm. |
| 31 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (DSR-2025-8.13.16)120 Watt |
| 32 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (DSR-2025-8.16.5)200 Watt |
| 33 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. (DSR-2025-2.2.13)100 A,30KA,FPMCCB |
| 34 | Supplying and fixing 63 A rating TPN, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 35 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (DSR-2025-5.2) |
| 36 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer, excavation and re-filling etc. as required. (DSR-2025-5.11) |
| 37 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR-2025-5.15) |
| 38 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. (DSR-2025-5.18) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender