Tender For B.O.Q For Operationalization Of Old Sdh Damhal Hanji Pora By Way Of Strengthening And Improvement Of Hospital Infrastructure B.W.O Electric Work
Tender Value
6.01 Lakhs
Estimated cost
Bid Submission
11 Nov 2026
6 days left
EMD
12028
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kulgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Operationalization Of Old Sdh Damhal Hanji Pora By Way Of Strengthening And Improvement Of Hospital Infrastructure B.W.O Electric Work
BOQ
| Sl. No. | Item Description |
| 1 | Internal Wiring |
| 2 | Wiring for light point/fan point/exhaust fan point/call bell point with 2 × 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, conforming to IS 694, with conductors as per IS 8130 and insulation as per IS 5831, and having fire performance in accordance with IEC 60332, ISI marked with valid BIS license, complete with all accessories , ( Havell/ Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor or OEMs/ firms holding ISO 9001 certification (Quality Management System) and shall be supplied with routine test certificates, and any material not conforming to the specified standards shall be rejected , complete with all accessories as required; single core cable in surface / recessed medium class PVC conduit ( including cost of conduit), with modular switch ( Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc. as required. |
| 3 | Group-A |
| 4 | Group-C |
| 5 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed mediumclass PVC conduit ( including cost of conduit) |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.) |
| 7 | Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit,( including cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 3 pin 5-10 A modular socket outlet and 2 no. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- (Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.) |
| 9 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. 3 pin 5/6A socket outlet |
| 10 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. Indicator |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 , single core cable in surface/ recessed medium class PVC conduitas required. Including cost of conduit. |
| 12 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Lighting Circuit) |
| 13 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire ( Heating submain) |
| 14 | S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve ,Schneider / Legrand /ABB, / Havells ,/ Siemens/ L&T / Hager /BCH make OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer in charge. |
| 15 | 6-32 Amp SP MCB |
| 16 | 63amp DP MCB |
| 17 | 63amp TPN MCB |
| 18 | Supply and fixing modular blanking plates on existing modular switch plates,excluding cost of plates. |
| 19 | Supplying and fixing following way, Horizontal type,Single pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections,powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 20 | 6 way (4+18), Double door |
| 21 | Lighting Fixtures and Fans |
| 22 | Supply installation testing and commissioning of 10 W LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W . The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt. approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures also. (Philips/ Havel's /Wipro make / sample to be approved before installation). |
| 23 | Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with necessary frame, mounting arrangement, louvers/shutter, and all accessories as required; the fan shall be of robust construction with high-grade engineering plastic/metal body, aerodynamically designed blades, and heavy-duty copper motor suitable for continuous operation, conforming to relevant Indian Standards and safety requirements of Havell /Bajaj/Crompton/ USHA/Orient OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge as per site requirement and necessary connections. |
| 24 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, , ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, suitable long down rod, 2 no. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Atomberg/Orient/USHA /Havells /Crompton / OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge. |
| 25 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make. |
| 26 | Cabling |
| 27 | S/Laying ( partly overhead/ partly underground) , testing and commissioning of XLPE aluminum armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. Havell/Eq. standard make as directed by engineer in charge and making endtermination with brass compression gland and aluminum lugs of required size. |
| 28 | 50 sq.mm 3.5 core ( armoured) |
| 29 | Main panel/ Earthing |
| 30 | PANEL: Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminum Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. The scope of work also entails securely installing the panel into the ground with concrete encasing its legs (As per approved design,size may vary as per site requirement) |
| 31 | INCOMING |
| 32 | 250 amp FP MCCB 50 KA Legrand /Schneider/L&T/ABB make. |
| 33 | 4 No. of Aluminum Bus Bar of 500 Amp. |
| 34 | Change over switch 250 Amp Front operated |
| 35 | 4 No. of Aluminum Bus Bar of 500 Amp |
| 36 | Digital meters and phase indicators -1 set. |
| 37 | OUTGOING |
| 38 | 63 amp TPN 10KA MCB |
| 39 | 63 amp DP 10KA MCB |
| 40 | Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick insize. |
| 41 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit then embedding 2.5 mtr. Long GI earthing electrode, 60 mm dia. Connecting the electrode with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemicalcompound. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender