Drinking Water Supply and Sanitation Local Bodies Closing in 10 days TDR #58235817

Tender For Rerouting Of 150Mm Dia Di Distribution Near Kalli Kottai Main Road Due To Culvert Crossing Providing 100Mm Dia Ms Pipe And Di Sluice Valves Water Supply Distribution Main Line In Jari Kondal Atti - Division 50 Kondal Atti Zone Iv In Salem

Issued by Local Bodies · Salem, Tamil Nadu
Tender Value
4.15 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
10 days left
EMD
4150
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Salem → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Rerouting Of 150Mm Dia Di Distribution Near Kalli Kottai Main Road Due To Culvert Crossing Providing 100Mm Dia Ms Pipe And Di Sluice Valves Water Supply Distribution Main Line In Jari Kondal Atti - Division 50 Kondal Atti Zone Iv In Salem City Municipal Corporation.

BOQ

Name of Work:- Rerouting of 150mm dia DI Distribution near Kalli Kottai Main Road due to Culvert Crossing Providing 100mm dia MS Pipe and DI Sluice Valves Water Supply Distribution Main Line in Jari Kondal atti - Division 50 Kondal atti Zone IV in Salem City Municipal Corporation.
Sl. No. Item Description
1Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers\
2Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil.SS20B
3Supplying and delivery of MS pipes / specials without inside lining and outside coating but with anti rust painting as per IS 14589 -1999 as directed officers.
4Supply and Delivery of the following Water Supply Pipes & Specials etc., complete.
5110mm Dia PVC Pipe 6ksc
6110mm PVC Flange Socket
7110 x 90 mm dia Reducer
8Solvent Cement
9Supply and delivery of DI D / F (Soft Seated) resilient seated soft sealing Gate Valves (Sluice Valves / Scour Valves) as per following sizes with body bonnet of ductile cast iron of grade GGG 40, wedge fully rubber lined with EDPM, replaceable spindle nut, without gland packing and with 3 O-ring protection on the shaft and seals of NBR and with replaceable stem nut and the valves should be of vacuum tight and 100 % leak proof with face to face dimensions as per BS 5163 - 89 / IS 14846 - 2000 / DIN 3202 F4. All the valves should be with Electrostatice powder coating both inside and outside pocket less less straight thro body passage. All the valves are to be compatible for buried application with pressure rating PN 16 including all cost and conveyance.etc complete. As per standard specification
1080mm dia
11100mm dia
12150mm dia
13Supply , Delivery and fixing Charges for Jointing Materials
14Rubber insertion Sheet
15MS Bolt and nuts
16150mm dia DI Flange Socket Page 1 of 2
17150mm dia MJ Collar
18100mm dia MJ Collar
19Lowering of MS pipes and specials into the trenches andlaying to proper grade and alignment and as directed by the officers
20114.30mm dia MS Pipe 6mm thick
21Jointing MS Pipe and specials with welding including cost ofall materials and labours etc.,
22114.30mm dia MS Pipe 6mm thick
23Jointing D.I Double flanged pipes and specials with rubberinsertion including cost of lubricants.
24114.30mm dia MS Pipe 6mm thick
25Hire charges for arranging vehicles such as JCB including fuel charges and all other charges etc. complete
26Hire charges for 33KVA Generator for welding purpose with fuel and crew charges including transportation
27Towards labour Charges for Interlinking with Exiting Distruction Main and necessary Specials etc., complete.
28Kalli Kottai Main Road
29100mm dia PVC and DI Pipe
30150mm dia DI Pipe
31Towards labour Charges for Erection of Sluice Valves and AirValve and necessary Specials including Labour charges etc., complete.
3280mm dia
33100mm dia
34150mm dia
35Refilling with excavated soil (other than sand) complying with the standard specification for filling in foundation and basement Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58235817
AUTHORITY Local Bodies
TENDER VALUE 4.15 Lakhs
LAST DATE 13-11-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Rerouting Of 150Mm Dia Di Distribution Near Kalli Kottai Main Road Due To Culvert Crossing Providing 100Mm Dia Ms Pipe And Di Sluice Valves Water Supply Distribution Main Line In Jari Kondal Atti - Division 50 Kondal Atti Zone Iv In Salem City Municipal Corporation.
Basic Detail
Tender No E2-EST NO-557-WS-2025-2026
Bidding Type Tender
Location
City Salem
State Tamil Nadu
Key Dates
Publish Date 27 Oct 2026
Submission Date 13 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 4.15 Lakhs
Tender Fee Ref. Documents
EMD 4150
Exemption Not Available
Document List
9baf1d90-b073-48e1-9e18-69a4710fae94.html
BOQ_862962.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

9baf1d90-b073-48e1-9e18-69a4710fae94.html

xls

BOQ_862962.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender