Tender For Purchase Of Non Consumable Items For Mechanical Department
Tender Overview
Project Description
Tender for Purchase Of Non Consumable Items For Mechanical Department , Cooling Tower Test Kit Rig (Make - Jps Make Model - Rac 01) Specification 1. Material Stainless Steel - 304 Grade 16 Gauge 2. Cooling Tower Packing - Cross Corrugated Pvc Fill 3. Dimension - 250X250 & Ht - 1000 Mm 4. Air Blower - 1 Hp 5. Pump - 1/2 Hp 6. Water Heater Or Geyser - 3 Kw 7. Temperature Indicator - 4 Digit - 6 Channel - 1 No; Rtd 6 Mm Sensor - 6 Nos 8. Air Flow Measurement - U Tube Manometer - 300 Mm - Acrylic 9. Water Flow Measurement - Acrylic Rotameter 10. Supply Tank Ss - Size 300X500x300 Mm Height 11. Control Board - 16 Amps Mcb With Neon Indicator 12. Panel Board - Ms Sheet Metal 13. Castor Wheels Provided - 4 Inch With Brake Exercises Conduct A Test On The Cooling Tower And Determine Its Efficiency , Recirculation Type Air-Conditioning System Kit (Make - Jps Make Model - Rac 03) Specification 1. Type - Recirculating Duct Vapour Compression Refrigeration System 2. Compressor - 1 Ton Hermetically Sealed 3. Condenser - 13X12 Inches 3 Row Air-Cooled Finned Tube Condenser With Axial Fan 4. Evaporator - 13X12 Inches 3 Row Cooling Coil With Recirculating Duct Arrangement With Axial Fan 5. Expansion Device - Capillary Tube 6. Refrigerant - R 22 7. Air Flow Measurement - Anemometer And Sling Psychrometer 8. Electrical Measurement - Digital Voltmeter, Digital Ammeter And Energy Meter 9. Power Supply 230 V Ac, Single Phase, 50 Hz 10. Fresh Air Duct With Damper - 300X300x1200 Mm; Return Air Duct With Damper - 300X300x1200 Mm; Recirculating Duct - 300X300x600 Mm; Air Conditioned Space - 900X450x1200 Mm Transparent Duct 11. Reversing Valve For Winter Air Conditioning With A Solenoid Switch Hot & Cool In Same Coil Heat Pump Method 12. Filter Drier - Dm-5 13. Pressure Gauges - 2 Nos (Suction Side - 800 Psi; Discharge Side - 800 Psi) 14. Temperature Indicator - 4 Digit- 6 Channel 15. Rtd Sensors 16. Voltage Stabilizer - 4 Kva 17. Frame Construction - Ms Painted Frame With Castor Wheels 18. Detailed Manual With Sample Readings & Calculation Exercises 1. Set The Winter Comfort Condition In The Desired Space Using A Recirculation Type Air - Conditioning System And Also Determine Its Cooling Capacity. 2. Set The Summer Comfort Condition In The Desired Space Using A Recirculation Type Air-Conditioning System And Also Determine Its Cooling Capacity.
BOQ
| Sl. No. | Item Description |
| 1 | Cooling Tower Test Kit Rig(Make – JPS MAKE Model – RAC 01)Specification1. Material Stainless steel – 304 Grade 16 Gauge2. Cooling Tower Packing – cross corrugated PVC Fill3. Dimension – 250x250 & Ht – 1000 mm4. Air blower - 1 HP5. Pump - 1/2 HP6. Water heater or Geyser – 3 kW7. Temperature indicator – 4 digit – 6 channel – 1 no; RTD 6 mm sensor – 6 Nos8. Air Flow Measurement – U Tube Manometer - 300 mm – Acrylic9. Water flow Measurement – Acrylic Rotameter10. Supply tank SS – Size 300x500x300 mm Height11. Control Board - 16 Amps MCB with Neon Indicator12. Panel Board - MS Sheet Metal13. Castor wheels provided – 4 inch with brakeExercisesConduct a test on the cooling tower and determine its efficiency |
| 2 | Recirculation Type Air-Conditioning System Kit(Make – JPS MAKE Model – RAC 03)Specification1. Type – Recirculating Duct Vapour Compression Refrigeration System2. Compressor – 1 Ton Hermetically Sealed3. Condenser – 13x12 inches 3 row Air-cooled finned tube condenser with axial fan4. Evaporator - 13x12 inches 3 row Cooling coil with Recirculating duct arrangement with Axial Fan5. Expansion Device – Capillary tube6. Refrigerant – R 227. Air Flow Measurement – Anemometer and sling psychrometer8. Electrical Measurement – Digital voltmeter, digital ammeter and energy meter9. Power Supply 230 V AC, Single Phase, 50 Hz10. Fresh Air duct with damper – 300x300x1200 mm; Return Air Duct with damper - 300x300x1200 mm; Recirculating Duct – 300x300x600 mm; Air Conditioned space – 900x450x1200 mm Transparent duct11. Reversing Valve for Winter Air Conditioning with a Solenoid Switch Hot & Cool in Same Coil Heat Pump Method12. Filter Drier – Dm-513. Pressure gauges – 2 Nos (Suction side – 800 Psi; Discharge side – 800 Psi)14. Temperature indicator – 4 digit- 6 channel15. RTD Sensors16. Voltage Stabilizer – 4 KVA 17. Frame Construction - MS painted frame with castor wheels18. Detailed manual with sample readings & CalculationExercises1. Set the winter comfort condition in the desired space using a recirculation type air – conditioning system and also determine its cooling capacity.2. Set the summer comfort condition in the desired space using a recirculation type air-conditioning system and also determine its cooling capacity. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender