Tender For Providing Of Street Light And Improvement Works To Mgr Nagar Burial Ground In Ward No 90, South Zone. Roc No.6359/2026/Md4
Tender Overview
Project Description
Tender for Providing Of Street Light And Improvement Works To Mgr Nagar Burial Ground In Ward No 90, South Zone. Roc No.6359/2026/Md4
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Nov-2026 | date extension | Date | 20-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Cleaning the Juncle using Labour as per the Direction of the Departmental officers Etc., Complete |
| 2 | Providing and masonry and civil work for the spiral pole pit including Earth work, Base Concrete, Centering & RCC coloumn etc., complete as per the direction o fthe Departmental officers |
| 3 | Earth work excavation in all soils and Sub Soils with initial lead and lift including all Labour Charges as per the Direction of the Departmental officers etc. complete. |
| 4 | Cement concrete 1:4:8 mix ( One Cement, Four Sand , Eight Aggregate)using 40mm size HBG metal from approved quarry Complying with Standard Specification etc. complete |
| 5 | Cement concrete of 1:2:4 mix (One part of cement, two parts of sand and four parts of course aggregates by volume) using granite hard broken stones of 20mm for flooring concrete laid in layers of not more than 10cm thick complete complying with standard specification and drawings as directed by the engineer including all cost and conveyance of materials laying curing etc., complete. |
| 6 | Brick work in Cement mortar 1:5 mix ( One cement, Five Sand) using Iind class ground moulded Burnt bricks from Approved Chamber etc. complete |
| 7 | Providing Solid Block masonry in Cement mortar 1:5 mix using I St Class Solid Block as per the direction of the departmental officers etc., complete. |
| 8 | Plastering for brickwork and concrete surfaces using cement mortar 1:5 (One part of cement, five parts of sand by volume) thickness 12mm (average) for all internal/external surfaces like superstructure, rainwater ducts, elevation |
| 9 | Providing Flooring with Ellis pattern using 6mm chips (No sand to be used) including all materials and labour charges etc. complete. |
| 10 | Supply and laying of Ordinary inerlocking blocks 60mm thick using M20 grade concrete flooring cost including ramming using mechanical earth rammer before and after laying the interlock blocks etc complete. |
| 11 | Painting with plastic emulsion paint in two coats over a base coat of Primer in approved colour and quality etc., complete. |
| 12 | Supply and fixing of M.S.Sheet doors and Grills including one coat of red oxide paint etc. complete |
| 13 | Painting with enamel paint in two coats of approved colour and quality over new iron work etc. complete. |
| 14 | Supply, Erection of 8m Free Standing Four ArmS Bracket 8 sided Octogonally continously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification Bottom Pole Dia - 130mm, Top Pole Dia - 70 mm, Thickness of Pole - 3 mm, The pole should be hot dip galvanized confirming to BESN ISO-1461 with thickness of 65 Micron |
| 15 | Supply, Erection of 8m Free Standing single ArmS Bracket 8 sided Octogonally continously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification Bottom Pole Dia - 130mm, Top Pole Dia - 70 mm, Thickness of Pole - 3 mm, The pole should be hot dip galvanized confirming to BESN ISO-1461 with thickness of 65 Micron |
| 16 | Supply and Laying of 2 x 6 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (Elect data p.no.68) |
| 17 | Supply and Fixing of 60W LED Street light Fitting with necessary Bowl and Bracket and Bulp as per Standard Quality as per the Direction of the Departmental officers etc., complete. |
| 18 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed copper cable of 1100 V grade with suitable rigid pipe on walls & ceiling for open light / fan point |
| 19 | Supply and fixing of single box type 4\\"40W flu fitting completed with copper choke and condensor,with condult pipe suspension from the ceiling with PVC unsheathed Copper leads from terminals to the fitting with Tube. |
| 20 | Supply and laying of pipes as per standard specification etc complete., |
| 21 | 63mm dia PVC pipe |
| 22 | 25mm dia upvc pipe |
| 23 | 20mm dia Tap |
| 24 | 25mm dia upvc valve Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender