Drinking Water Supply and Sanitation Government Departments Closing in 2 days TDR #58229301

Tender For Annual Rate Contract For The Work Of Providing, Laying, Jointing And Testing Of Di Pipelines With Interconnection Works Including 1 Year Defect Liability Period Under The Jurisdiction Of Phed City Division V (South) Jaipur.

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
1.50 Crore
Estimated cost
Bid Submission
12 Nov 2026
2 days left
EMD
3 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Rate Contract For The Work Of Providing, Laying, Jointing And Testing Of Di Pipelines With Interconnection Works Including 1 Year Defect Liability Period Under The Jurisdiction Of Phed City Division V (South) Jaipur.

BOQ

Name of Work:- Annual rate contract for the work of Providing, Laying, Jointing and Testing of DI pipelines with interconnection works including 1 year defect liability period under the jurisdiction of PHED City Division V (South) Jaipur.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.
2All kinds of soil
3Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
4Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
5Bituminous courses
6Granular courses
7Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
880 mm
9100 mm
10150 mm
11200 mm
12250 mm
13300 mm
14350 mm
15400 mm
16450 mm
17500 mm
18600 mm
19Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Rates are exclusive of GST.
20100 mm
21150 mm
22200 mm
23250 mm
24300 mm
25350 mm
26400 mm
27450 mm
28500 mm
29600 mm
30Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work).
31All End Socketed
32Upto 300 mm Diameter
33Above 300mm and up to 600 mm diameter
34All End Flanged
35Upto 300 mm Diameter
36Above 300mm and up to 600 mm diameter
37Single Flange/ MJ Collar
38Upto 300 mm Diameter
39Above 300mm and up to 600 mm diameter
40Double Flange Pipe (up to 1 mtr. length)
41Upto 300 mm Diameter
42Above 300mm and up to 600 mm diameter
43Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical Specifications and as per direction of Engineer.Note : E/w to be measured and paid separately.
44Plain ended CI specials including tail piece, spigot end and socket end.
45Up to 300 mm dia
46Above 300 mm and up to 600 mm dia
47Double flanged CI pipe fittings.
48Up to 300 mm dia
49Above 300 mm and up to 600 mm dia
50Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
51MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
52Work of lnter Connection in AC/PVC pipe line including dismantling of BT road/ cc road/ excavation of soil, cutting of existing pipeline, jointing of tee (complete) and other specials excluding sluice valve, dewatering, transportation from JE store and providing adequate safety of site & testing for water proof interconnection using his own T&P, labour & dewatering pump etc. required to complete the job. (Material such as Tee/ Tee clamp/ rubber sheet/CID joints required for lnter connection shall be provided by the department free of cost).
53In Kaccha
54up to 110 mm AC/PVC
55up to 160 mm AC/PVC
56up to 250 mm AC/PVC
57up to 400 mm AC/PVC
58In Bituminous road
59up to 110 mm AC/PVC
60up to 160 mm AC/PVC
61up to 250 mm AC/PVC
62up to 400 mm AC/PVC
63In concrete road
64up to 110 mm AC/PVC
65up to 160 mm AC/PVC
66up to 250 mm AC/PVC
67up to 400 mm AC/PVC
68Work of lnter Connection in DI/CI/HDPE pipe line including dismantling of BT road/ cc road/ excavation of soil, cutting of existing pipeline, jointing of tee (complete) and other specials excluding sluice valve, dewatering, transportation from JE store and providing adequate safety of site & testing for water proof interconnection using his own T&P, labour & dewatering pump etc. required to complete the job. (Material such as Tee/ Tee clamp/ rubber sheet/CID joints required for lnter connection shall be provided by the department free of cost).
69In Katccha
7080-100 mm CI/DI/MS
71125-150 mm CI/DI/MS
72200-250 mm CI/DI/MS
73300-400 mm CI/DI/MS
74In Bituminous road
7580-100 mm CI/DI/MS
76125-150 mm CI/DI/MS
77200-250 mm CI/DI/MS
78300-400 mm CI/DI/MS
79In concrete road
8080-100 mm CI/DI/MS
81125-150 mm CI/DI/MS
82200-250 mm CI/DI/MS
83300-400 mm CI/DI/MS
84Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
85Manually Operated CI Sluice valve of Class PN-1.0
8680 mm HW
87100 mm HW
88125 mm HW
89150 mm HW
90200 mm HW
91250 mm HW
92300 mm HW
93350 mm with Gear
94400 mm with Gear
95450 mm with Gear
96500 mm with Gear
97600 mm with Gear
98Motorized Sluice Valves with Electric Actuator with integral starter of Class PN 1.0
9980 mm dia
100100 mm dia
101125 mm dia
102150 mm dia
103200 mm dia
104250 mm dia
105300 mm dia
106350 mm dia
107400 mm dia
108450 mm dia
109500 mm dia
110600 mm dia.
111Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
112Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
11380 mm dia
114100 mm dia
115125 mm dia
116150 mm dia
117200 mm dia
118250 mm dia
119300 mm dia
120350 mm dia
121400 mm dia
122450 mm dia
123500 mm dia
124600 mm dia.
125Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.0
12680 mm dia
127100 mm dia
128125 mm dia
129150 mm dia
130200 mm dia
131250 mm dia
132300 mm dia
133350 mm dia
134400 mm dia
135450 mm dia
136500 mm dia
137600 mm dia.
138Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
13980 mm dia
140100 mm dia
141125 mm dia
142150 mm dia
143200 mm dia
144250 mm dia
145300 mm dia
146350 mm dia
147400 mm dia
148450 mm dia
149500 mm dia
150600 mm dia.
151Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
152Class PN 1.6, Manually Operated with Gear
153100 mm dia
154150 mm dia
155200 mm dia
156250 mm dia
157300 mm dia
158350 mm dia
159400 mm dia
160450 mm dia
161500 mm dia
162600 mm dia
163Class PN 1.0, Motorised Operated
164200 mm dia
165250 mm dia
166300 mm dia
167350 mm dia
168400 mm dia
169450 mm dia
170500 mm dia
171600 mm dia
172Class PN 1.6, Motorised Operated
173200 mm dia
174250 mm dia
175300 mm dia
176350 mm dia
177400 mm dia
178450 mm dia
179500 mm dia
180600 mm dia
181Providing, lowering, aligning, fixing in position in pipe line, DI resilient seated (soft seated) Concentric Wafer type, Butterfly valves of approved make of following Pressure rating & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc - DI (same as body material) / CS, Face to face dimensions as per DIN 3202 F4/ IS 13095 , Flanges Drilled as per IS:1538 ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside . Liner & Disc seal - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410/420 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \\"O \\"ring seal , Nut-Bolt confirming to IS:1363 and IS: 1367/ Galvanised steel, Insertion rubber of black EPDM 6mm thick ,Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
182Class PN 1.6, Wafer Type
18380 mm (Lever Operated)
184100 mm (Lever Operated)
185125 mm (Lever Operated
186150 mm (Lever Operated)
187200 mm (with Gear)
188250 mm (with Gear)
189300 mm (with Gear)
190Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
191Class PN 1.6
19280 mm dia
193100 mm dia
194125 mm dia
195150 mm dia
196200 mm dia
197250 mm dia
198300 mm dia
199350 mm dia
200400 mm dia
201450 mm dia
202500 mm dia
203600 mm dia
204Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
205Class PN 1.6
20680 mm dia
207100 mm dia
208125 mm dia
209150 mm dia
210200 mm dia
211250 mm dia
212300 mm dia
213350 mm dia
214400 mm dia
215450 mm dia
216500 mm dia
217Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.
218Class PN 1.6
21940 mm dia
22050 mm dia
22180 mm dia
222100 mm dia
223150 mm dia
224200 mm dia
225Providing, lowering, aligning, fixing in position and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512 ,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512. ), Valve including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.
226Class PN 1.6
22750 mm dia
22880 mm dia
229100 mm dia
230150 mm dia
231200 mm dia
232Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- ChargeNote: Rates are exclusive of tail piece/ dismantling joints and earth work. .
233Plunger Type Flow Control Valve
23480 mm dia
235100mm dia
236125 mm dia
237150mm dia
238200mm dia
239250mm dia
240300mm dia
241350mm dia
242400mm dia
243450mm dia
244500mm dia
245600mm dia
246Providing, lowering, aligning and fixing in position DI D/F Diaphragm type Pressure Reducing / Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body & Bonnet - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or ASTM A 536, Diaphragm and Resilient seal disc - Flexible, non-wicking nylon fabric reinforced synthetic elastomer -Buna-N / EPDM (FDA / WRAS approved), Body Seat Ring - Cast stainless steel ASTM- A 351 GR. CF8M / AISI- 316, raised, replaceable inline & onsite Stem - Stainless Steel, AISI-316/410, raised, replaceable inline & onsite Spring & Bearing bush- Stainless Steel, AISI-316 ,Disc guide, disc retainer & diaphragm washer - Stainless Steel, AISI-304/ 316/Bronze ,Seal- EPDM/ NBR ,Pilot Body- Stainless Steel, AISI-304/ CF8 or Brass Tubing - Stainless Steel, AISI-304 / Copper ,Solenoid Valve- Stainless Steel, AISI-316 ,Throttling plug - Stainless Steel, AISI-304, Nut- Bolts - SS Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. insertion rubber of black EPDM 6mm thick Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
247Pilot operated SCADA Compatible Diaphragm Type Pressure Reducing Valves (Class PN 1.6)
24880 mm dia
249100 mm dia
250125 mm dia
251150 mm dia
252200 mm dia
253250 mm dia
254300 mm dia
255350 mm dia
256400 mm dia
257450 mm dia
258500 mm dia
259600 mm dia
260Diaphragm Type Flow Control Valve With Electrical Actuator suitable for SCADA (PN 1.6 )
26180 mm dia
262100 mm dia
263125 mm dia
264150 mm dia
265200 mm dia
266250 mm dia
267300 mm dia
268350 mm dia
269400 mm dia
270450 mm dia
271500 mm dia
272600 mm dia
273Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0
27480 mm dia
275100 mm dia.
276125 mm dia.
277150 mm dia.
278200 mm dia.
279250 mm dia.
280300 mm dia.
281350 mm dia
282400 mm dia
283450 mm dia
284Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S.pipe B class as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least1.50 m above road/ground level and at least30-45 cm below road/ground level and suitable size hole in road as per approved pattern as when it becomes shabby but at least after every alternate shifting at new location after shifting/removal of barricaing holes shall be filled up properly and site is to be cleared in all respect
285Carriage of materials(Earth,sand,lime,morrummanure or sludge
286upto50 m
287Add for each50 m(upto 500 M)
288For500 m
289For 1 KM
290Add for each 1 Km beyond Ist Km (upto 5 Km.)
291For 5 KM
292Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.
293For Class-AA loading
294Sluice valve chamber of size 1.13 m x0.85 m x1.325 m- for pipe size-up to 100 mm
295Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm
296Sluice valve chamber of size 1.26m x1.185m x1.88mfor pipe size-from 200-to-300mm
297Sluice valve chamber of size 1.39m x1.43m x2.245mfor pipe size-from 350-to-450mm
298Sluice valve chamber of size 1.61m x1.75m x2.85mfor pipe size-from 500-to-700mm
299For Class-A loading
300Sluice valve chamber of size1.13m x0.85m x1.27mfor pipe size-upto100mm
301Sluice valve chamber of size1.17m x0.95m x1.415mfor pipe size-from 125-to-150mm
302Sluice valve chamber of size1.26m x1.185m x1.82mfor pipe size-from 200-to-300mm
303Sluice valve chamber of size1.39m x1.43m x2.185mfor pipe size-from 350-to-450mm
304Sluice valve chamber of size1.61m x1.75m x2.795mfor pipe size-from 500-to-700mm
305For in-campus Valve Chambers
306Sluice valve chamber of size1.13m x0.85m x1.225m for pipe size-upto100mm
307Sluice valve chamber of size1.17m x0.95m x1.37mfor pipe size-from 125-to-150mm
308Sluice valve chamber of size1.26m x1.185m x1.76mfor pipe size-from 200-to-300mm
309Sluice valve chamber of size1.39m x1.43m x2.125mfor pipe size-from 350-to-450mm
310Sluice valve chamber of size1.61m x1.75m x2.72mfor pipe size-from 500-to-700mm
311Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.
312For Class-AA loading
313Air valve chamber of size0.9m x1m x1.695m for air valve size-from 50 mm-to-80mm
314Air valve chamber of size1m x1.1m x1.945m for air valve size of 100mm
315Air valve chamber of size1.05m x1.4m x2.42m, for air valve size of 150mm
316Air valve chamber of size1.325m x1.7m x2.875m, for air valve size of 200mm
317For Class-A loading
318Air valve chamber of size0.9m x1m x1.71m for air valve size-from 50 mm-to-80mm
319Air valve chamber of size1m x1.1m x1.96m, for air valve size of 100mm
320Air valve chamber of size1.05m x1.4m x2.42m, for air valve size of 150mm
321Air valve chamber of size1.325m x1.7m x2.9m, for air valve size of 200mm
322For in-campus Valve Chambers
323Air valve chamber of size0.9m x1m x1.66mfor air valve size-from 50 mm-to-80mm
324Air valve chamber of size1m x1.1m x1.91mfor air valve size of 100mm
325Air valve chamber of size1.05m x1.4m x2.37m, for air valve size of 150mm
326Air valve chamber of size1.325m x1.7m x2.825m, for air valve size of 200mm
327Construction of RCC Scour valve chamber wet type for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.
328For Class-AA loading
329Scour valve chamber of size1.13m x0.85m x1.985m, for connecting pipe size-upto100mm
330Scour valve chamber of size1.175m x0.95m x2.285m, for connecting pipe size-more than 100 mm & up to 150mm
331Scour valve chamber of size1.2m x1.08m x2.485m, for connecting pipe size- more than 150 mm & up to 200mm
332For Class-A loading
333Scour valve chamber of size1.13m x0.85m x1.95m, for connecting pipe size-upto100mm
334Scour valve chamber of size1.175m x0.95m x2.25m, for connecting pipe size-more than 100 mm & upto150mm
335Scour valve chamber of size1.2m x1.08m x2.45m, for connecting pipe size-more than 150 mm & upto200mm
336Construction of RCC Scour valve chamber dry type for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.
337For Class-AA loading
338Scour valve chamber of size1.13m x0.85m x1.985m, for connecting pipe size-upto100mm
339Scour valve chamber of size1.175m x0.95m x2.285m, for connecting pipe size- more than 100 mm & up to 150mm
340Scour valve chamber of size1.2m x1.08m x2.485m, for connecting pipe size- more than 150 mm & up to 200mm
341For Class-A loading
342Scour valve chamber of size1.13m x0.85m x1.95m, for connecting pipe size-upto100mm
343Scour valve chamber of size1.175m x0.95m x2.25m, for connecting pipe size-more than 100 mm & upto150mm
344Scour valve chamber of size1.2m x1.08m x2.45m, for connecting pipe size-more than 150 mm & upto200mm
345Construction of RCC pillar for following size of air valves including earthwork excavation, RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge.
346Air valve pillar for air valves size of 80mm dia
347Air valve pillar for air valves size of 100mm dia
348Air valve pillar for air valves size of 150mm dia
349Air valve pillar for air valves size of 200mm dia
350SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
351EFM 50 mm
352EFM 80 mm
353EFM100 mm
354EFM 125 mm
355EFM 150 mm
356EFM 200 mm
357EFM 250 mm
358EFM 300 mm
359EFM 400 mm
360EFM 450 mm
361EFM 500 mm
362EFM 600 mm
363SITC of Ultrasonic Flow Meter of approved make of following dia sized pipelines and specifications complete: Media : Water (Raw/Clear ) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow velocity range: -10 m/s to +10m/s (bidirectional), Power supply- 80 to 240 v/ AC, 50 Hz.,Output 1 : 4-20 mA, Communication Output : RS 485, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Acoustic path: single/ dual, Accuracy : ± 1% of M.V (max.) for size 50-300mm and ± 2% of M.V (max.) for size 350-2000mm (single path) , Transmitter Enclosure: Cast Aluminium, Sensor cable: encapsulated, Sensor mounting method: V / Z type, Protection type: IP 67, including all materials required for Ultrasonic Flow Meter complete in all respect as per technical specification and as per direction of Engineer In-Charge.
364UFM 200mm -600 mm (CLAMP ON TYPE)
365UFM 200mm -600 mm (INSERTION TYPE)
366SITC of Bulk Flow Meter with removable mechanism class \\"B\\" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
367BFM 80 mm
368BFM100 mm
369BFM 125 mm
370BFM 150 mm
371BFM 200 mm
372BFM 250 mm
373BFM 300 mm
374BFM 400 mm
375BFM 450 mm
376BFM 500 mm
377BFM 600 mm
378House hold tap connections
379Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PP saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or ball valve (min. weight 165 gm) and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid separately.Rate is exclusive of GST.
380For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
381Providing Household Tap Connection as per technical specification and approved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid separately.Rate is exclusive of GST.
382For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
383Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.
384Note: Road cut and restoration is not part of this item and paid separately.Rate is exclusive of GST.
385For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
386P & F Bib cock (IS : 781 mark), superior quality of approved make , brass 400 gm, 15 mm nominal bore.Rate is exclusive of GST.
387P & F Bib cock (IS : 8931 mark), superior quality of approved make, chrome plated with complete brass body including brass handle with wt. 300 to 325 gm.15 mm nominal bore.Rate is exclusive of GST.
388Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.Rate is exclusive of GST.
389Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.Rate is exclusive of GST. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58229301
AUTHORITY Government Departments
TENDER VALUE 1.50 Crore
LAST DATE 12-11-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Annual Rate Contract For The Work Of Providing, Laying, Jointing And Testing Of Di Pipelines With Interconnection Works Including 1 Year Defect Liability Period Under The Jurisdiction Of Phed City Division V (South) Jaipur.
Basic Detail
Tender No NIT-15/2026-27
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 27 Oct 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 1.50 Crore
Tender Fee 5000
EMD 3 Lakhs
Exemption Available
Document List
2b2be948-1001-4fb6-8e7b-48ecfecc24e6.html
BOQ_1072787.xls
TD15.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

2b2be948-1001-4fb6-8e7b-48ecfecc24e6.html

xls

BOQ_1072787.xls

pdf

TD15.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender