Tender for Annual Rate Contract For Repair And Maintenance Works Block- Bijoliya

BOQ

Name of Work:- Annual Rate Contract for repair and maintenance works BLOCK- BIJOLIYA
Sl. No. Item Description
1P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
2P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
3Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
4Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
5Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
6Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
7Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required.
8Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
9Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
10Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
11Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
12Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
13Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required.
14Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
15P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required.
16Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required.
17Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required.
18Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required.
19Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required.
206 A one way switch
2116 A one way switch 1M
2216 Amp. 2 Module switch With Led Indicator
2332 Amp. 2 Module switch With Led Indicator
24Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.
256 A 3 pin shuttered socket
266/16 A shuttered socket
27Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required.
285 step fan regulator 2 Module
29Providing & Fixing of 3 M Key card switch with Load capacity 20 amp, Off time delay 30 Sec. made out of unbreakable and fire retardant virgin poly carbonate, including making connections, testing etc as required.
30Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.
311/2 Module
323 Module
334 Module
345 Module
356 Module
368 Module
3710 Module
3812 Module
3916/18 Module
40Providing & Fixing of following size cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.
411/2 Module
423 Module
434 Module
445 Module
456 Module
468 Module
4710 Module
4812 Module
4916/18 Module
50Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.
511-2 Module
523 Module
534-5 Module
546-8 Module
5510-12 Module
5616/18 Module
57Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.
581-2 Module
593 Module
604/5 Module
616 / 8 module
6210 / 12 module
6316/18 module
64Providing & Fixing of Multiple socket with surge and spikes protection cartridge not less then 5 KV with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required.
65Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate.
6680mm x 50mm
67100/105mm x 50mm
68150/160mm x 50mm
69195/200mm x 50mm
70Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required.
71Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
72P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder coated ,including dressing, ferruling and punching of telephone cable with krone tool etc. as required.
7310 Pairs
7420 Pairs
7550 Pairs
76100 Pairs
77200 Pairs
78P & F Portable Residual Current Device (PRCD) 3 pin plug top 16 A, 30 mA sensitivity. Plug should have feature of power indicator, test button and reset function etc. as required.
79SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
803 pole MCCB With Thermal Magnetic release
81up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
82up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
83125 Amp , 25 kA, adjustable O/L & fixed S/C setting,
84160 Amp , 25 kA, adjustable O/L & fixed S/C setting,
85200 Amp , 25 kA, adjustable O/L & fixed S/C setting,
86250 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
87250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
88400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
89630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
90800 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
91Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size.
92Up to 457 mm size
93more than 457 mm & up to 610 mm
94Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required.
95Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor, Cotter pin, rubber grommet making connection testing etc. as required.
96With regulator
97Without regulator
98Providing & Fixing BLDC technology step regulator compatible ceiling fan, with aluminium body & aluminium blade, power factor not less then 0.9 , following service value (CMM/W) , with following air delivery , speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10%, copper winding with class of Insulation 'F' complete with with secondary support safety cable ( steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.
991200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20
1001400 mm sweep with Air delivery >/= 270 CMM and Service Value 7.70
1011200 mm sweep with Air delivery >/= 215 CMM and Service Value 7.00
1021400 mm sweep with Air delivery >/= 260 CMM and Service Value 6.4
103Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required.
104150 mm sweep with Min. Air delivery 350 Cubic meter/Hr, 2000 RPM
105200 mm sweep with Min. Air delivery 800 Cubic meter/Hr, 1600 RPM
106250 mm sweep with Min. Air delivery 1150 Cubic meter/Hr, 1300 RPM
107SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1081170mm(+/-10%) LED batten with min. lumen output 2200 lm
109570mm (+/-10%) batten with min. lumen output 1000 lm
1101170mm(+/-10%) LED batten with min. lumen output 4400 lm
111SITC of IP20 SMD Mid Power LED batten with integrated box (min.1200mmx40mmx60mm including reflector) with replacable driver fixture made from Powder coated Extruded aluminium housing ,Min. lumen output 4800 lm, System lumen efficacy ≥ 120 lm/Watt output nly at CW (5700K to 6500K), internal surge protection of 4.0 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
112SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
113Recessed Mounting
114Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt)
115Minimum lumen output 1300 lm
116Minimum lumen output 1600 lm
117Minimum lumen output 1950 lm
118Minimum lumen output 2400 lm
119Surface Mounting (with extruded alumn. Housing )
120Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt)
121Minimum lumen output 1300 lm
122Minimum lumen output 1600 lm
123Minimum lumen output 1950 lm
124Minimum lumen output 2400 lm
125SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
126Recessed Mounting
127Minimum lumen output 4320 lm
128Minimum lumen output 4800 lm
129Surface Mounting (Driver should be Inside the Luminaire)
130Minimum lumen output 4320 lm
131Minimum lumen output 4800 lm
132SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
133Recessed Mounting
134Minimum lumen output 2880 lm
135Minimum lumen output 3600 lm
136Surface Mounting (Driver should be Inside the Luminaire)
137Minimum lumen output 2880 lm
138Minimum lumen output 3600 lm
139SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
140Recessed Mounting
141Minimum lumen output 4320 lm
142Minimum lumen output 4800 lm
143Surface Mounting (Driver should be Inside the Luminaire)
144Minimum lumen output 4320 lm
145Minimum lumen output 4800 lm
146SITC of IP20, 1100-1200 mm x 50-60 mm x 70-85 mm size Suspended mounting backlit & SMD mid power type LED linear Light fixture made from Extruded Aluminium housing, PMMA Acrylic/Extruded Polycarbonate push fit type diffuser for uniform light distribution. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). Lumen Efficacy will be >=100lm/W only at CW (5700K to 6500K) ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating . Luminiare can connect each other through jointer kit (cost of jointer kit is included) as required.
147Minimum lumen output 2000 lm
148Minimum lumen output 3000 lm
149SITC of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbay light fixture made from Pressure Die Cast Aluminium housing, UV stabilized PC Cover/ Toughened glass diffuser, potted driver, Eye bolt for mounting, system lumen efficacy ≥150 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and . surge protection 4 KV inbuilt & 10 KV external inside fixture as required.
150Minimum lumen output 12000 lm
151Minimum lumen output 15000 lm
152Minimum lumen output 18000 lm
153Minimum lumen output 22500 lm
154SITC of Suspended mounting IP66 IK08 rated Integrated High power LED Wellglass light fixture made from Pressure Die Cast Aluminium housing, potted driver, Eye bolt for mounting, PC clear / Opal Diffuser, system lumen efficacy ≥130 lm/Watt output only at CW (5700K to 6500K) , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating surge protection 4 KV inbuilt & 10 KV external inside fixture as required.
155Minimum lumen output 4550 lm
156Minimum lumen output 9100 lm
157SITC of IP 20 box made out from 1.0 mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).
158Suitable for 2' LED Tube shape fixture for single rod
159Suitable for 4' LED Tube shape fixture for single rod
160Suitable for 4' LED Tube shape fixture for double rod
161SITC of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt outputonly at CW (5700K to 6500K) , internal surge protection of 2.5 KV,THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
162600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing
1631200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing
1641200mm, Min. Lumens output 2000 lm LED Tube rod with Glass Housing
165SITC of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥120 lm/Watt output only at CW (5700K to 6500K) , THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
166Minimum lumen output 1200 lm
167SITC of IP-20 LED Recessed / Surface Mounted, Round / Sqaure backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5.life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
168Recessed Mounting
169Minimum lumen output 1300 lm
170Minimum lumen output 1600 lm
171Minimum lumen output 1950 lm
172Minimum lumen output 2400 lm
173Surface Mounting (with extruded alumn. Housing )
174Minimum lumen output 1300 lm
175Minimum lumen output 1600 lm
176Minimum lumen output 1950 lm
177Minimum lumen output 2400 lm
178SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5 life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
179Recessed Mounting
180Minimum lumen output 4320 lm
181Minimum lumen output 4800 lm
182Surface Mounting (Driver should be Inside the Luminaire)
183Minimum lumen output 4320 lm
184Minimum lumen output 4800 lm
185SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCM (standard deviation colour matching)<5life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
186Recessed Mounting
187Minimum lumen output 4320 lm
188Minimum lumen output 4800 lm
189Surface Mounting (Driver should be Inside the Luminaire)
190Minimum lumen output 4320 lm
191Minimum lumen output 4800 lm
192SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCM (standard deviation colour matching)<5 life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
193Recessed Mounting
194Minimum lumen output 2880 lm
195Minimum lumen output 3600 lm
196Surface Mounting (Driver should be Inside the Luminaire)
197Minimum lumen output 2880 lm
198Minimum lumen output 3600 lm
199SITC of IP-20 LED Recessed Mounted, Round backlit & COB type LED Downlighter of Powder Coated diecast/Extruded Aluminium body including trim with aluminium deflector and construction as per IS:10322 with 2.5 KV surge protected Isolated driver with Short & Open circuit protection (Input 320VAC-48 hours protection, Input 350VAC-2 hours protection) having efficiency > 85%, operating voltage 140-270 V AC. System Lumen efficacy of ≥ 100 lm /watt, at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, UGR(Unified Glare Rating)< 19, Fliker free(current ripple should be below 5%), SDCM(Standard Deviation Color Matching) < 5, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
200lumen output 550 lm to 770 lm
201lumen output 880 lm to 1100 lm
202lumen output 1320 lm to 1650 lm
203Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
204Short point (up to 3 mtr.)
205Medium point (up to 6 mtr.)
206Long point (up to 10 mtr.)
207Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.
208Short point (up to 3 mtr.)
209Medium point (up to 6 mtr.)
210Long point (up to 10 mtr.)
211Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
212On board
213Short point (up to 3 mtr.)
214Medium point (up to 6 mtr.)
215Long point (up to 10 mtr..)
216S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
21720 mm
21825 mm
21932 mm
22040 mm
22150 mm
222Recessed PVC Conduit Wiring with Non Modular accessories
223Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
224Short point (up to 3 mtr.)
225Medium point (up to 6 mtr.)
226Long point (up to 10 mtr.)
227Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
228Short point (up to 3 mtr.)
229Medium point (up to 6 mtr.)
230Long point (up to 10 mtr..)
231Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
232On board
233Short point (up to 3 mtr.)
234Medium point (up to 6 mtr.)
235Long point (up to 10 mtr..)
236S&F of following sizes of polypropelene corrugated flexible conduit including gland on both side of flexible conduit as required.
23716 mm OD
23820 mm OD
23925 mm OD
24032 mm OD
24140 mm OD
242Surface PVC Conduit Wiring with Modular accessories
243Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal/Surface mounted UPVC molded modular box, 6 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
244Short point (up to 3 mtr.)
245Medium point (up to 6 mtr.)
246Long point (up to 10 mtr.)
247Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.
248Short point (up to 3 mtr.)
249Medium point (up to 6 mtr.)
250Long point (up to 10 mtr.)
251Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
252On board
253Short point (up to 3 mtr.)
254Medium point (up to 6 mtr.)
255Long point (up to 10 mtr..)
256S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required.
25720 mm
25825 mm
25932 mm
26040 mm
26150 mm
262Surface PVC Conduit Wiring with Non Modular accessories
263Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size , 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
264Short point (up to 3 mtr.)
265Medium point (up to 6 mtr.)
266Long point (up to 10 mtr.)
267Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
268Short point (up to 3 mtr.)
269Medium point (up to 6 mtr.)
270Long point (up to 10 mtr..)
271Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
272On board
273Short point (up to 3 mtr.)
274Medium point (up to 6 mtr.)
275Long point (up to 10 mtr..)
276Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil
277Banking excavated earth in layers not exceeding 20cm. in depth breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers, and rolling every 3rd and top- most layer with power roller of 8-10 tonne capacity and dressing up in embankments for roads, flood banks marginal banks, and guide banks etc. lead up to 50 Mtr. and lift up to 1.5 Mtr. All kinds of soils
278Deduct for not rolling with power roller of 8 to 10 tonne capacity for banking excavated earth in layers not exceeding 20 cm in depth
279Deduct for not watering the excavated earth for banking.
280Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed:All kinds of soil
281Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed:
282Ordinary rock
283Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
284Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available :
285Ordinary rock
286Depth not exceeding 1.5 Mtr.
287Depth exceeding 1.5 Mtr. but not exceeding 3 Mtr
288Depth exceeding 3 Mtr. but not exceeding 4.5 Mtr
289P & F of Open timbering in case of shafts, wells, soak pits, manholes and the like including strutting, shoring complete (Measurement to be taken of the face area timbered):
290Depth not exceeding 1.5 Mtr.
291Depth exceeding 1.5 Mtr. but not exceeding 3 Mtr
292Depth exceeding 3 Mtr. but not exceeding 4.5 Mtr
293P & F Open timbering over area including strutting, shoring etc complete (Measurement to be taken of the face area timbered):
294Depth not exceeding 1.5 Mtr.
295Depth exceeding 1.5 Mtr. but not exceeding 3 Mtr
296Depth exceeding 3 Mtr. but not exceeding 4.5 Mtr
297Add extra for planking and strutting in open timbering if required to be left permanently in position (face area of timber permanently left to be measured)
298Add extra rate for quantities of works, executed :
299In or under water and /or liquid mud, including pumping out water as P.Mtr. 20% required depth
300In or under foul position , including pumping out water as required P.Mtr. 25% depth Note for item no. 1.24:- The extra percentage rate is applicable in respect of each item but limited to quantities of work executed in these difficult conditions. The unit, namely, metre depth, to be considered for payment, shall be the depth measured from the sub soil water level up to the centre of gravity of the qty executed in difficult condition. The depth shall be reckoned correct to 0.10m, 0.05m or more shall be taken as 0.10m and less than 0.05m ignorel.
301Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
302Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in
303All kinds of soil
304Ordinary or hard rock. 1.27(a) Supplying and Filling in plinth with river sand under floors including Cum 1024.00 watering ramming consolidating and dressing complete including cost of sand 1.27 (b) Supplying and Filling in plinth with blown sand under floors including Cum 450.00 watering ramming consolidating and dressing complete including cost of sand.
305Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil
306Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same: All kinds of soil
307Excavating holes upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc disposing of surplus excavted soil; as directed within a lead of 50 m and lift to 1.5 m
308All kinds of soil
309Ordinary rock
310Hard rock (requiring blasting) useful material 30%
311Hard rock(blasting prohibited) useful material 30%
312Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
313M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
314M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
315M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
316M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
317M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
3181:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
3191:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
320Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
321Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix
322Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix
323Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Arches, arch ribs, domes, vaults, shells, folded plate, chimneys, shafts , roofs having slope more than 15º ,vertical and horizontal fins individually or forming box louvers, facias and eaves boards M20 grade Nominal Mix / Design Mix
324Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge . All works upto floor V floorM20 grade Design Mix by using cement as per codal provision.
325Add extra for providing richer mixes respectively at all floor levels
326Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix.
327Providing M-30 grade concrete by using cement as per codal provision instead of M-20 grade design mix.
328Add extra for RCC work in superstructure above floor five level for each four floor or part thereof .
329Deduct for using less cement quantity than the quantity as provided in the item of design mix concrete/RMC as arrived as per mix design.(on cement quantity)
330Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
331Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :
332Walls (any thickness) including attached pilasters, buttresses plinth and string course.
333Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
334Columns, pillars, posts and struts etc.
335Add extra for shuttering in circular work (in respective centering Sqm 20% and shuttering items)
336Add extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured)
337Add extra for centering and shuttering work in superstructure above floor five level for each four floor or part thereof .
338Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.
339Cold twisted deformed bars (IS : 1786).
340Hot rolled deformed bars (IS : 1139).
341Labour charges for cutting, bending for fabrication and binding reinforcement (plain or tor/ribbed/TMT steel) as per drawing and design for R.C.C. and R.B. work including cost of binding wire with all lead and lift up to floor five level complete.
342Add extra for reinforcement in superstructure above floor five level for each four floor or part thereof .
343Providing ,arranging and erecting 50mm dia M.S. pipe cup lock shuttering arrangement above the ground level upto the height given below. The girding arrangement of cup lock system should have 2.50 meter 3.00 meter long coupling pipes and 0.90mt long lacer pipe (Horizontal bracing pipes) reconnected in both ways so as to make a square grid of size 0.90x0.90 meter in plan. The Horizontal bracing and lacer pipes should have a maximum spacing of 1.50 meter c/c both ways. The bottom of the coupling pipe must rest over a firm support at ground. the shuttering plates of 900mmx600mm size duly braced by angle supports and should rest over 50mmx50mm size wooden logs supported by 75x40x6mm size channels and U-Jacks made of M.S.25mm dia steel bars with adjustable thread and lock arrangement placed at a spacing of 0.60 meter c/c. The whole arrangement should be duly shored from ground by U-Jacks and lacer pipes to prevent any lateral movement during casting of slabs. Additional support as per direction of engineer in charge are also to by provided wherever felt necessary. The work would include transportation of material erecting the whole grid structure, bracing both way, shoring, leveling of shuttering and removal of form work complete as per direction of Engineer in charge for all the floors upto the height of:- (a) Upto 6.63 meter height (b) Upto 9.14 meter height Sqm. 1722.00
344Rebarring work in old R.C.C structures including making bore hole to adjust required bar diameter and filling a good quality filler to provide a tensil strength as per requirement and fix the Bar to the saction including cost of bars. (i) 8 mm bar (ii) 10 mm bar Each 515.00 (iii) 12 mm bar Each 581.00 (iv) 16 mm bar Each 914.00 (v) 20 mm bar Each 1186.00 (vi) 25 mm bar Each 1715.00
345Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :
346Cement mortar 1 : 4 (1 cement : 4 coarse sand)
347Cement mortar 1 : 6 (1 cement : 6 coarse sand)
348Add extra for Square or Rectangular Pillars in Superstructre brick work up to five storey
349Upto 45 cm length and all sides are free
350Upto 45 cm length and two corners are free
351Upto 90 cm length and all sides are free
352Half brick masonry in foundation & plinth using bricks of designation 75
353Cement mortar 1 : 3 (1 cement : 3 coarse sand)
354Cement mortar 1 : 4 (1 cement : 4 coarse sand)
355Cement mortar 1 : 6 (1 cement : 6 coarse sand)
356Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75
357Cement mortar 1 : 3 (1 cement : 3 coarse sand)
358Cement mortar 1 : 4 (1 cement : 4 coarse sand)
359Cement mortar 1 : 6 (1 cement : 6 coarse sand)
360Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry .
361Brick work in partition in super structure upto five storey 7cm. thick (brick on edges) using bricks of class designation 75 in :
362Cement mortar 1 : 3 (1 cement : 3 coarse sand)
363Cement mortar 1 : 4 (1 cement : 4 coarse sand)
364Brick work in super structure upto five storey with selected bricks of class designation 75 in exposed brick work including making horizontal and vertical grooves 10mm. wide 12mm. deep complete in cement mortar 1:6.
365Brick work with clay flyash F.P.S. brick (IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in :
366Cement mortar 1 : 4 (1 cement : 4 coarse sand)
367Cement mortar 1 : 6 (1 cement : 6 coarse sand)
368Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.
369Cement mortar 1 : 4 (1 cement : 4 coarse sand)
370Cement mortar 1 : 6 (1 cement : 6 coarse sand)
371Add extra for brick work in superstructure above floor five level, for each four floors or part thereof.
372Quantity in Cum.
373Quantity in Sqm.
374Add extra over item of brick work with class designation 100 in substitution of class designation 75 :
375Quantity in Cum.
376Quantity in Sqm.
377Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.
378Cement mortar 1 : 4 (1 cement : 4 coarse sand)
379Cement mortar 1 : 6 (1 cement : 6 coarse sand)
380Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in.
381Cement mortar 1 : 4 (1 cement : 4 coarse sand)
382Cement mortar 1 : 6 (1 cement : 6 coarse sand)
383Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:
384Cement Mortar 1:6 ( 1-Cement : 6-Sand).
385Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
386Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
387Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
388Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
389Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.
390Add Extra if I/rail section is used Kg. 10%
391Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
392Steel work in built up tubular trusses including cutting, hoisting (height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.
393Hot finished welded type tubes.
394Hot finished seamless type tubes.
395Electric resistance or induction butt welded tubes.
396Extra for hoisting and fixing for every additional one metre or part thereof beyond 10 mtr height.
397Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
398Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer- in-charge :
399Profile B
400Profile C
401Profile E
402Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide.
403Extra for providing D type pipe head as top of hand railing Kg. 10%
404Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
405Extra if square,rectangular hollow tubelar sections are used or grill Kg. 10% made by flats only
406Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design).
407Providing and fixing in position collapsible steel shutters with Sqm. vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension).
408Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame & diagonals braces of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners, 25mm dia pulley 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer.
409Providing and fixing 1mm thick M.S. sheet garrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners including all fittings and applying a coat of approved steel primer : (Excluding cost of frames) 9.12.1 Using M.S. angles 40 x 40 x 6mm for diagonal braces. 9.12.2 Using flats 30 x 6mm for diagonal braces and central cross piece. Sqm. 3292.00
410Supplying and fixing rolling shutters of approved make, made of 80 Sqm. x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment).
411Providing & fixing ball bearing for rolling shutters
412Extra for providing mechanical device chain and crank operation for operating rolling shutters. 9.15.1 Exceeding 10.00 Sqm and upto 16.80 Sqm in the area. 9.15.2 Exceeding 16.80 Sqm in the area. Sqm. 976.00 9.16 Extra for providing grilled rolling shutters manufactured out of 8 Sqm. 360.00 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-charge. (area of grill to be measured).
413Providing and fixing M.S. sheet 1mm thick single leaf door shutter Sqm. in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 9.17.1 Extra for double leaf shutters. Sqm. 20%
414Fixing standard steel glazed doors, windows and ventilators in walls Sqm. with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including fixing of glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws (only steel windows with lugs, glass pane cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.)
415Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
416Doors
417Windows fixed
418Windows side hung /Ventilators top or centre hung (openable)
419Partly fixed and partly openable [ fixed area not to exceed 33%]
420Providing brass handles/peg stays and fittings in place of oxidized Sqm. 5% fitting
421Aluminium handles/peg stays fitting instead of oxidized fitting. Sqm. 3%
4225mm thick plain glass instead of 4mm thick plain glass
423Deduct for Not providing glass panels
424Deduct for Pin headed 4mm thick glass panels is used instead of Sqm. 5% 4mm thick plain glass
425Deduct for Not provided oxidised fittings. Sqm. 5%
426Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the Sqm. metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
427Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
428Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge 9.28.1 Window openable. 9.28.2 Window fixed. Sqm 3851.00 9.28.3 Extra for additional shutter in pipe section windows with wire gauge Sqm 1819.00 14 mesh x 24 gauge
429180cm high fencing with angle iron post 55x55x6mm. placed at every 3Mtr. apart 45cm. in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every tenth post to be strutted with 55x55x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete.
430150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete
431150cm high fencing with angle iron 50x50x6mm. placed at every 3Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 5 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete.
432120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with four horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete.
433Add or deduct for each wire line over basic item
434Add or deduct for additional or less higher per 10 Cm. over basic Mtr 5% item
435Extra for using galvanized barbed wire instead of black barbed wire. Mtr. 5% Each wire 9.35.1 Add Extra if barbed wire fencing is done on wall upto height of Mtr. 5% 3.00 Mtr.
436Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.
43750mm x 50mm x 3.15mm
43875mm x 15mm x 3.15mm
439100mm x 100mm x 3.15mm
440150mm x 150mm x 3.15mm
441Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra)
442Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts, lock and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge
443Grading roof for water proofing treatment with water proffing compound 10.17.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 10.17.2 Cement mortar 1:3 (1 cement : 3 coarse sand) Cum 6425.00 10.17.3 Cement mortar 1:4 (1cement : 4 coarse sand) Cum 5348.00
444Providing and laying brick kharanja on roofs with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound in square pattern 10.18.1 75mm to 100mm thick average 10.18.2 55mm to 60mm thick average Sqm 276.00
445Providing and laying brick tiles of class designation 100 over roofs grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat .
446Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machine complete on 20 mm thick bed of cement sand mortar 1 : 4.
447Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS. 2645 over the RCC slab including cleaning the surface before treatment. (b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cement mortar 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:4 (1 cement :4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300xmm square (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm.
448Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
449Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete.
450Providing & laying broken glazed titles on roof (broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge.
451Crazy marble stone flooring 20mm thick marble stone with black or of specified colour topping including filling the gaps with cement marble chips mix in proportion of 4 : 7 (4cement : 7 white black or white or black marble chips) size from 1mm to 4mm by volume and under layer of 25mm thick cement concrete [1:2:4, graded stone aggregate 12.5mm nominal size] rubbing and polishing and cement slurry etc. complete : In ordinary cement.
452Precast terrazo tiles of approved make, 20mm thick with marble chips of size upto 6mm laid in floors, and landing, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete on 20mm thick bed of cement sand mortar 1 : 4.
453Light shade using white cement.
454Medium shade using approximately 50% white cement and 50% ordinary cement.
455Dark shade using ordinary cement.
456Ordinary cement without any pigment.
457Extra if terrazo tiles are laid in treads of steps not exceeding 30 cm in width.
458Precast terrazzo tiles of approved make 20mm thick with marble chips of size upto 6mm in skirting & risers, treads of steps and dados 12mm thick cement plaster 1:3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of :
459Light shade using white cement.
460Medium shade using approximately 50% white cement and 50% ordinary cement.
461Dark shade using ordinary cement.
462Ordinary cement without any pigment.
463Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 :
464Light shade using shade cement.
465Medium shade using approximately 50% white cement and 50% ordinary cement.
466Dark shade using ordinary cement.
467Ordinary cement without any pigment.
468Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)
469Light shade using shade cement.
470Dark shade using ordinary cement.
471Ordinary cement without any pigment.
472Add Extra for polished chequered precast cement concrete tiles 10% over item No. 11.17.1, 11.17.2, 11.17.3, 11.17.4
473Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
474For area of each slab from 901 to 2000 Sq.Cm :
475For area of each slab from 2001 to 5000 Sq.Cm
476Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
477For area of each slab upto 2001 Sqcm
478For area of each slab from 2001 to 5000 Sqcm
479Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointing with cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects :
480Fine dressed & machine cut edges 30-35 mm thicksand stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI.
481Red sand stone (Karauli stone)
482Pink sand stone (Bansi Paharpur stone)
483Mandana stone
484Fine grinded Gangsaw cut 30-35 mm thick stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement :4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI.
485Red sand stone (Karauli stone)
486Pink sand stone (Bansi Paharpur stone)
487Mandana stone
488Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
489Extra for Mirror polishing on terrazzo/Kota stone work where ever required to give high gloss finish complete.
490Random rubble dry stone Kharanja under floor.
491Providing & Laying Tactile tile (for vision impaired persons is standard of size 300x300x20mm and confirming to IS 1231 of 1980 (Re affirmed in 2006) in all colours & sheds further product should confirm ASTM 303 for shad resistance and DIN51099 for colour fastness etc. laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 course sand) in all shapes & patterns including grouting the joint which white cement mixer) will matching pigments etc complete is per direction of Engineer-in-charges. Grade M 30
492Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :
49320mm thick
49412mm thick
495Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :
49620mm thick .
49712mm thick .
498Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :
49920mm thick.
50012mm thick.
501Plaster on new surface on walls in cement sand mortar 1:8 including racking of joint etc. complete fine finish :
50220mm thick.
50312mm thick.
5046 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand)
505Rough cast plaster upto 10m height above ground level with a mixture of sand and gravel or crushed stone from 6mm to 10mm nominal size dashed over and including the fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement
506Pebble dash plaster upto 10m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) with 10% finely grounded hydrated lime by volume of cement
507Washed stone grit plaster on exterior walls of height upto 10 M. above level in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2kg of cement per sqm, top layer 15 mm cement plaster 1:1/2:2 ( 1 cement : 1/2 coarse sand : 2 stone chipping size 10 mm nominal size) in panel with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chipping, complete as per specification and direction of Engineer in charge. (Payment for providing grooves shall be made separately)
508Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
509Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts embedding hold fasts in cement concrete blocks with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominaal size)painting two coats of coal tar to sides of chaukhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 metres lead
510Door chowkhats
511Window chowkhats
512Making the opening in masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/rubbish to the nearest municipal dumping ground.For door/windows/clerestory windows
513Renewing glass panes, with putty and nails wherever necessary:
514Float glass panes of thickness 4 mm
515Float glass panes of thickness 5 mm
5164mm thick plain glass panes.
5175mm thick plain glass panes.
518Renewing glass panes and refixing existing wooden fillets :
5194mm thick plain glass panes.
5205mm thick plain glass panes.
521Renewal of old putty of glass panes (length)
522Refixing old glass panes with putty and nails
523Fixing old glass panes with wooden fillets (Excluding cost of fillets)
524Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase and making good and painting exposed portion of the clamps complete.
525Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
526Repair to brick masonary in cement sand mortar 1:6 with new brick.
527Cement plaster 1:3 under old stone slabs with admixture (gur,nails,binding wire to mesh and scraping scales & dressing joints of slabs complete.
528Proofing upto 25 mm thickness.
529Proofing above 25 mm thickness& upto 60 mm thickness
530Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc. complete in all respects.
531Replacing broken roofing slab in patches including lime terrace, ceiling plaster etc. including removal of broken slabs.
532Making holes in stone masonry wall upto 450 mm x 450 mm size and making good in CM 1:6.
533Grinding of existing floor with
534Providing and fixing double scaffolding system on the exterior side, upto five story made with 4\\" wooden member 1.5 m c/c horizontal and vertical direction joining with rassi, clamps, challies. The scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of EI.The lavation area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding.Note : This item to be used for maintence work judically
535Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete
536Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc.
537Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 2 in following stepsi) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.ii) Applying Epoxy primer on the exposed steel bars.iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.vi) Cure the plastered surface for 15 days All work including scaffolding etc. complete in all respect.
538Replacement of stone Chajja with sriwan in damaged portion as per existing thickness and width in CM 1 : 3 with removal of old damaged pieces of chajja including top plaster of chajja and bottom pointing in CM 1 : 3 with scoffolding upto Ground floor level as per direction of Engineer in charge
539Add Extra for each additional floor
540Repair to damaged cement plaster of stone chajja with CM 1 : 3 of required thickness on top & bottom as per existing pattern and making patta etc complete up to three floor level as per direction of Engineer in charge including all necessary scoffolding etc
541Mechanised cleaning of storage tanks comprises of following 6 stage as mentioned below: 1. Mechanical dewatering 2. Desalting removal of leftover dirty water and sludge with sludge pump 3. Cleaning of wall, ceiling and floor by high pressure water jet with help of equipments which creates a pressure of 100-150 bar 4. Removal of remaing sludge from floor with the help of industrial vacuum cleaner. 5. Spraying of non toxic, bio degradable ecofriendly and bacterial agent certified by a govt approved laborary to disinfect the tank from all harmfull pathogens. The dose should be safe as per the UECD guidelines & 23 adopted on 17 th december 2001. 6. Treatment of inside tank by exposing UV radiation to kill further suspended or floating bacteria if any
542Upto 500 ltr.
543Above 500 ltr. to 1000 Ltr.
544Above 1000 ltr.
545Repair of door, window shutters including cost of material and labour for change of damaged : (a) Style / rail of teak wood 30mm thick/ Aluminium Section (i) 4\\"wide (ii) 6\\" wide Rmt. 294.00 (b) Panel by 0.00 (i) Shuttering Ply - 9mm thick (Commercial) Sqm. 658.00 (ii) Wire Gauge 14 mesh x 24 gauge Sqm. 587.00 (iii) Plain Glass Panes 4mm thick Sqm. 474.00 (c) Aldrop of mild Steel 0.00 (i) 12\\" long x12mm dia Each 162.00 (ii) 8\\" long x 10mm dia Each 117.00 (d) Stopper of Aluminium with 0.00 (i) Single Rubber Gutka Each 36.00 (ii) Double Rubber Gutka Each 52.00 (e) Door Springs of mild Steel Each 176.00 (f) Steel Hinges 0.00 (i) For Wooden Chowkhat 3\\" size. Each 26.00 (ii) For Wooden Chowkhat 4\\" size Each 37.00 (iii) For Stone Chowkhat ,4\\"size Each 32.00 (g) Mild Steel Tower Bolt 6\\" long Each 43.00 (h) Steel Locking Bolt Each 58.00 (i) Steel Handle 6\\" size Each 26.00
546Making of hole in R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EI
547From diameter 100mm to 150mm
548Diameter above 150mm
549Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge.
550Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.
5511: 3: 6 or richer mix.
5521: 4: 8 or leaner mix.
553Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
554Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
555Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge
556Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work
557Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
558In cement mortar.
559Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 meters (stacks of cleaned bricks shall be measured):
560From brick work in cement mortar. Nos.
561Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:
562In cement mortar.
563Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer in charge :
564In cement mortar.
565Removing mortar from stones and cleaning stones and concrete articles including stacking (net quantity of stacks of cleaned materials will be measured):
566Cement mortar.
567Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:
568Of area 3 square meter and below.
569Of area exceeding 3 square meter.
570Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead: 14.13.1 Of area 3 square meter and below. 14.13.2 Of area exceeding 3 square meter. Each 61.00
571Dismantling steel work in single sections including dismembering and stacking within 50 meters lead in: 14.17.1 R.S. joists. 14.17.2 Channels, angles, tees & flats. Kg 1.00
572Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead.
573Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.
574Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: 14.23.1 For thickness of tiles 10mm to 25mm. 14.23.2 For thickness of tiles 25mm to 40mm. Sqm 37.00
575Dismantling dry brick pitching in floors drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
576Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
577Dismantling brick tiles covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
578Dismantling precast concrete or stone slabs in wall partitions etc. including stacking within 50 meter lead: 14.40.1 Thickness up to 40mm. 14.40.2 Thickness 40mm up to 75mm Sqm 129.00
579Dismantling CI or asbestos rain water pipe with fitting and clamps including stacking within 50 meter lead: 14.41.1 Up to 80mm dia pipe. 14.41.2 100mm dia pipe. Mtr. 21.00 14.41.3 150mm dia pipe. Mtr. 22.00
580Dismantling tar felt over roofing complete including stacking of serviceable material and disposal of unserviceable material within 50-meter lead.
581Dismantling GI pipes (external work) including excavation and refilling trenches after taking out the pipes and including stacking of pipes within 50 meter lead: 14.43.1 15mm to 40mm nominal bore. 14.43.2 Above 40mm nominal bore. Mtr. 52.00
582Dismantling CI pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into block, including stacking of pipes lead at site within 50 meter, of dia: 14.44.1 Up to 150mm dia. 14.44.2 Above 150mm dia. up to 300mm dia. Mtr. 162.00 14.44.3 Above 300mm dia. Mtr. 217.00
583Dismantling steel cylinder, R.C. pipes etc. including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes, within a lead of 50 meter, of dia: 14.45.1 Up to 600mm dia. 14.45.2 Above 600 mm dia. Mtr. 547.00
584Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes, and stacking the same within a lead of 50 meter, of dia: 14.46.1 Up to 150mm. 14.46.2 Above 150mm. Mtr. 116.00
585Taking out CI cover with frame from stone slab / RCC slab of inspection chambers of various sizes including dismantling of stone slab / RCC slab roofing and stacking of useful materials near the site and disposal of unserviceable materials within 50- meter lead.
586Taking out C.I. cover with frame from stone slab / RCC slab of manholes of various sizes including dismantling of stone slab / RCC slab roofing and stacking of useful materials near the site and disposal of unserviceable materials within 50-meter lead.
587Dismantling of RCC spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap stacking the useful material near the site and disposal of unserviceable materials within 50 meter lead.
588Dismantling of gully chamber of various sizes including CI grating with frame including stacking of useful materials near the site and disposal of unserviceable material within 50 meter lead including refilling the gap.
589Dismantling of CI sluice valve including stacking of useful materials within a lead of 50 meter: 14.52.1 Up to 150mm dia. 14.52.2 Above 150mm dia. Each 388.00
590Dismantling of spindle fire hydrant including stacking of useful material within 50 meter lead.
591Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead : 14.54.1 Upto 1.44 Sqm 14.54.2 Above 1.44 Sqm to 2.52 Sqm Sqm 508.00 14.54.3 Above 2.52 Sqm to 3.84 Sqm Sqm 762.00
592Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
593Dismantling CC jali including cost of making grooves in plaster and making good and including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. .
594Removing aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
595Making of hole (width up to 150 mm) in R.C.C. slab/wall/beams by power driven drilling machine complete as per direction of EI 14.58.1 upto 150mm thick 14.58.2 above 150 mm thick Each 297.00
596Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (i) Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. iv) IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
597Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :
598Serrated with central bulb (225 mm wide, 8-11 mm wide)
599Dumb bell with central bulb (180 mm wide, 8 mm wide)
600Kickers (320 mm wide, 5 mm thick)
601Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners, junction with polymer mixed slurry.
602Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @ 0.253 kg/sqm.b) laying second layer of Fiber glass cloth when the first layer is still green . Overlaps of joints of fiber cloth should not be less than 10 cm .c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all aroundd) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured
603Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot 1.45Kg. per square meter of area for each course, second course of roofing felt type 3 grade –I (Hessian based self finished bitumen felt )and fourth and final course of stone grit 6mm and down size of pea sized gravel spread at 6cubes diameter per square meter including preparation of surface, but excluding grading, complete with Bitumen felt (Hessian base) type 3 grade - I conforming to : 1322.
604Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ @ 1.45 ,1.20 and 1.45 Kg per sqm. of area respectively second and fourth courses of roofing felt type 3 grade-I conforming to IS 1322 (Hessian based self finished bitumen felt) conforming to IS 1322 and sixth and final course of stone grit 6mm and down size of pea sized gravel spread at 6 cubic dm. per square metre including preparation of surface but excluding grading complete .
605Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot at 1.45, 1.20 and 1.70 Kg. per Sqm. of area respectively second and fourth courses of roofing felt type 2 grade-I (fiber base self finished bitumen felt) and sixth and final course of stone grit 6mm and down size or pea sized gravel spread at 8cu.dm per sqm including preparation of surface excluding grading complete confirming to IS : 1322 and 1346.
606Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot at 1.45, 1.20 and 1.70Kg. per Sqm of area respectively second and fourth courses of roofing felt type 2 grade 2 (fiber base self finished bitumen felt) and sixth and final course of stone grit 6mm and down size of pea sized gravel spread at 8cu.dm per sqm including preparation of surface excluding grading complete confirming to IS : 1322 and 1346.
607Supplying and applying bituminous solution primer on roofs or on wall surface at 0.24 liter per sqm.
608Deduct for omitting in water proofing treatment final course of spreading stone grit 6mm. and down size of pea sized gravel :
609At 6dm3 per Sqm.
610At 8dm3 per Sqm.
611Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
612Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.3 mm thick
613Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
614Extra over items of Cement Plaster / Cement Concrete flooring / 125 gm Plain or RCC work Providing and mixing admixture of synthetic Fiber 6mm / 12mm. @ rate of 125gm. pack per 50 Kg. of Cement or in the ratio of as specified by manufacture specification and direction of Engineer In-charges with all leads and lifts.
615Supplying and providing of two components poly sulphide sealant containing solid contents, confirming to standard specification and approved compatible primer, for priming vertical faces prior to application of poly sulphide sealant including all labour charges for sealing of expansion joints after drill mixing of two components sealing compound. Cleaning and preparation of expansion joint using wire brush sand papering with emery paper and filing with suitable mechanical means. The work includes racking and cleaning of joints, sticking, debonding tape on bottom of joint, applying primer on edges, using masking tape on edges, providing of sealant and removal of masking tape immediately after providing sealant in joint.
616To vertical joint between RCC columns, bricks & stone masonry in size 40 mm width and 12 mm depth, including providing back up material (Thermocoal foam) if required.
617To joints in flooring, as per drawing with first layer of poly sulphide sealant in size 20 mm width and 10 mm depth over PE Foam and then providing polyethylene foam back up rod 25 mm dia size and finally providing another layer of poly sulphide sealant in size 20 mm width and 10 mm depth over P.E. back up rod as per application procedure and direction of Engineer-in-charge.
618Providing and fixing in position bitumen impregnated fiberboard confirming to IS: 1838 in expansion joints including the cost of primer sealing compound.
61912 mm. thick
62018 mm. thick
62125 mm. thick
622Providing and fixing expansion joint board for building RCC column beams, walls, slab of Polyethylene foam of density 30 to 35 Kg/m3 of Armour Board.
62320mm Thick
62425 mm Thick
62530 mm Thick
62640 mm Thick
62750 mm Thick
628Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as per design to match the colour / shade of wall treatment.
629Non-asbestos fibre cement board 6 mm thick as per IS:14862. 1
630Aluminum fluted strips 2 mm thick
631Acrylic sheet 5 mm thick
632Providing and filling in position bitumen sealing compound P. Cm. grade A (IS 1834 ) in expansion joints. Width for 100mtr. length
633Providing and filling in position bitumen mix filler of proportion 80 width per Kg. of hot bitumen, 1 Kg. of cement and 0.25 cubic meter of coarse cm depth per 100 mtr. sand for expansion joints. length
634Providing and fixing in cement sand mortar 1 : 3 single/double rebated R..C. Door Window and ventilator frames (Chowkhats) including 1% reinforcement as per design and concrete mix 1 : 2 : 4 cutting etc. complete incl. horns. and hold fasts :
635Size 75 x 50mm
636Size 75 x 75mm
637Size 100 x 75mm
638Size 125 x 75mm
639Extra for RC frames (Chowkhats) Curved in plan Mtr. 10%
640Extra for RCC frame finishing the exposed face with terrazo Mtr. 20% (Mosaic) finish.
641Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry :
642Size 100x 75mm
643Size 125 x 100mm
644Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames of approved quarry :
645Size 100 x 75mm.
646Size 125 x 100mm
647Providing & mixing admixture in Cement Concrete flooring/Cement Plaster/Plain or RCC work, Synthetic Polyster Triangular Construction Fiber of length 6mm/12mm/18mm with specific gravity 1.34 to 1.40 and diameter 10-40 microns and melting point>220 degrres centigrade by using 125 gm fiber for 50 kgs cement used as per direction of Engineer-in-charge.
648Providing & mixing admixture in Cement Mass Concrete flooring CC Road, RCC work, Canal Lining and Shotcrete Non Circular with ribbed surface Structural Synthetic Macro Fiber 42-50mm length, specific gravity of > 1.30 and diameter 0.8 - 1.20mm and melting poing > 220 degree centigrade @ 0.75% -100% by cement weight in mix as per direction of Engineer-in-charge.
649Nano technology water proofing, thermal insulation protection coating
650Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work.
651Providing & applying one coat of UV resistant polymer cement based waterproofing slurry coating of approved make and quality on concrete or plastered surface as per specifications including preparation of surface by cleaning brushing and dust removing, filling of cracks and making the surface leak proof by mixing one part of chemical with 2 parts of cement and 2 parts of water (covering area 1.86 Sq.M/Kg of chemical) including cost of cement, labour, tools & plant, scaffolding if necessary etc., complete as directed by Engineer in Charge. with Cement Motor before application and the same will be paid under relavent items.
652Providing & applying Three coat of Acrylic Water Proof membrane having sunlight and UV resistant properties over waterproofing slurry coat , initial coat of 50-75 micron thickness with diluting 1 part of chemical with 2 parts of clean water, over which applying 2 coats at 2 Hrs .intervals each with diluting 1 part of chemical with 20% of clean water for total thickness of 400 to 450 microns (covering area 0.9 Sq.M/Kg of chemical including preparation of surface by cleaning, brushing and dust removing, scaffolding if necessary etc., with contractor's labour, tools, machinery etc, complete as directed by Engineer in Charge.
653Providing & applying Three coat of pure Acrylic Water based elastomeric brush applied insulating coating on exterior surface overwaterproofing slurry coat , initial coat of 50-75 micron thickness with diluting 1 part of chemical with 2 parts of clean water, over which applying 2 coats at 2 Hrs, intervals each with diluting 1 part of chemical with 10% of clean water for total thickness of 400 to 450 microns (covering area 0.9 Sq.M/Kg of chemical) including preparation of surface by cleaning, brushing and dust removing, scaffolding if necessary etc., with contractor's labour, tools, machinery etc, complete as directed by Engineer in Charge.
654Providing and fixing 50mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of >350 kPa listed as per ASTM D 1621, density of 34-36 kg/m3 as per ASTM D 1622, water absorptions =< 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, part 1 of class B2 and as per ASTm E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the diretion of Engineer-in-Charge.
655Providing & fixing 50mm extruded polystyrene (XPS) insulation board density 36kg/m3, under or over RCC roof slab complete as per manufacturing specifications fixed with 1% suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
656Supply and Application of Solar IR Heat Reflective Coating System conforming to BIS Std IS 17218:2019 for concrete surface having minor leakage by thorough surface preparation to remove dust, dirt, molds etc. using High Pressure WaterJet / Wire Brush etc, opening of cracks and filling with elastomeric crack filler, then applying one absorption coat of UV resI tan1 elastomeric coating having min. 50% solids (i.e. Thermacool WP 51/or Equivalent), followed by application of \\"elastomeric clear coating White Cement\\" waterproofing coat having min. 400% elongation and tensile strength of 2.2 MPa and than top coating with 2 Coats of Solar lR Heat Reflective Coating conforming to BIS Standard IS 17218:2019 (i.e. Therrnacool 0.3C/or Equivalent) of cementitious surfaces, white colour, matt, surface coverage 3.25 sqm/Ltr/2 wat, dft 100- 120microns.The work shall be done as per the directions of Engineer-in-charges. water based pure acrylic, UV resistant, Solar lR Heat Reflective coating with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 sqm/Ltr/2 wat, dft 100- 120microns.The work shall be done as per the directions of Engineer-in-charges.
657P. & F Squatting Pan (Indian type) white glazed vitreous china 1st quality W.C. Pan (IS : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excluding the pair of foot rest.)
658Size 450mm.
659Size 510 mm
660Size 580mm
661P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:
662Size 530x410mm.
663Size 580x440mm.
664P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor
665P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor
666P & F Universal (anglo-Indian type) white glazed vitreous china W.C. pan 1st quality (IS 2556 Marked ) with P or Strap including cutting and making good the wall and floor
667P & F European type white glazed vitreous china 1st quality W.C. (IS : 2556 Mark) including cutting and making good the wall and floor
668Wall Mounting
669Wall Mounting (extended)
670Wall Mounting (syphonic) (A) Add extra over item No. 1.1 to 1.7, 1.14, 1.15, 1.19, 1.22 Each 50% ,1.23,1.38 & 1.42 for using approved light coloured vitreous china ware i.e.ivory champagne , perl , soft green , soft blue ,pink, ,light grey etc. instead of white vitreous chinawares. (B) Add extra over item No.1.1 to 1.7, 1.14, 1.15, 1.19, 1.22 Each 65% ,1.23,1.38 & 1.42 for using approved dark colored vitreous china ware i.e.Cherry Red , Dark blue, Jet black, Magenta, Burgandy instead of white vitreous chinawares.
671P & F water closet Seat Covers with brass hinges complete :
672Solid PVC (IS 2548 marked) grade-I Black for EWC.
673-do- White.
674-do- Coloured.
675-do- White.
676-do- Coloured.
677P & F C.P. lugs for toilet seat cover.
678Labour charges for removing W.C. pan (any type) of all sizes with care including all necessary fittings P or S trap.
679P & F White glazed Conversion Bend for W.C. from P trap to S trap. .
680P & F vitreous china P trap of approved quality
681Add extra if C.I.P trap is used in place of Vitreous china P trap for W.C.
682P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor.
683P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.
684Flat Back (small) size 456x355x265mm.
685Flat Back (large) or half stall size 610x400x80mm.
686Mini stall size 455x385x350mm.
687P & F W.V.C. Urinal Partition Plate of approved standard make of size 630x315mm including making good the wall.
688P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm.
689Makrana II quality marble having light spots
690Makrana `Albeta` Marble having light streaks.
691Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble.
692P & F W.V.C. Half-Round Channel of approved make in C.M. 1:3, joints finished in white cement of:
693Size 100mm dia.
694Size 150mm dia.
695P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:
696Size 450x350mm
697Labour charges for removing and refixing of urinals (all type & sizes) including all necessary fittings.
698P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall:
699WVC with C.P. brass bend.
700PVC with PVC bend as per IS : 7231 .
701PVC with PVC bend and superior internal fittings
702WVC for symphonic EWC.
703PVC with CP brass long band.
704P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, siphon with copper tube, C.I. brackets complete including cutting and making good the wall. WVC (as per IS : 2556) 10 litres.
705P & F Flush Pipe of approved make with complete fittings for high level flushing cistern:
706G.I. `B` class (Concealed) 25mm.
707G.I. `B` class (Concealed) 32 mm.
708PVC exposed (heavy) 32mm.
709GI (Sheet) hot galvanized exposed (10 litres).
710P & F WVC (10 litres) low-level flushing cistern with cover.
711P & F WVC (10 litres) low-level flushing cistern cover only
712P & F WVC syphon with plunger plate only.
713P & F WVC Auto cistern with cover only.
714P & F WVC Auto cistern cover only.
715P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make.
716For 4 Urinals
717For 3 Urinals
718For 2 Urinals
719For 1 Urinal
720P & F C.P. brass Urinal Spreader for stall urinal of approved make.
721P & F Synthetic (PTMT) Urinal Spreader for stall urinal of approved make.
722P & F C.P. brass Doom Waste Coupling 32 mm dia.
723P & F C.P. brass Doom Waste Coupling 40 mm dia.
724P & F Plastic Syphon of approved make for automatic flush tank.
725P & F Copper tube Syphon for auto flush tank.
726Removing and re-fixing of wash hand basin including all necessary fittings.
727P & F metal brackets duly painted including cutting & making good the wall.
728P & F C.P. Brass flush Valve with C.P. flush bend of approved make.
729Lever type with Elbow 32 mm dia
730Push type with Elbow 32 mm dia
731Concealed type for 115 mm thick wall
732Concealed type for 230 mm thick wall
733Economy model 25 mm dia.
734Economy model 32 mm dia.
735P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :
736Size 450 mm x 300 mm
737Size 510 mm x 400 mm
738Size 550 mm x 400 mm
739Size 580 mm x 450 mm
740Size 610 mm x 510 mm
741Size 400 mm x 400 mm or 450 mm x 390 mm Corner
742460 dia for counter top
743Size 550 mm x 400 mm dia for counter top
744Size 630 mm x 500 mm dia for counter top
745Add extra for using 25mm GI waste pipe instead of PVC waste pipe
746P & F Terrazzo (Mosaic) wash hand basin with supporting brackets waste coupling and PVC waste pipe complete, including painting of brackets making good the walls:
747450 mm x 280 mm
748550 mm x 400 mm
749P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :
750Fire clay glazed kitchen sink (I.S 771-1985 Marked) size 600 x 450 x 250mm.
751Fire clay glazed kitchen sink (I.S 771-1985 Marked) size 600 x 450 x 200 mm.
752WVC Lab sink (IS:2556 mark) size 530 x 430 x 180 mm
753WVC Lab sink (IS:2556 mark) size 500 x 350 x 150 mm
754WVC Lab sink (IS:2556 mark) size 450 x 300 x 150 mm
755Mosaic fine polished kitchen sink size 600 x 450 x 200mm.
756Mosaic fine polished kitchen sink size 450 x 450 x 200mm.
757Mosaic fine polished kitchen sink size 600 x 450 x 200 mm with 600 x 450mm drain board
7581.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. Overall size Bowl size (inches) (inches)
75918 x 16 x 6 16x14x6
76022 x 18 x 7 20x16x7
76124 x 18 x 8 20x16x8
76237 x 18 x 7 17x15x7 (with drain board)
76345 x 20 x 8 20x16x8 (with drain board) specified above.
764P & F Drain Board of approved make with C.I. brackets duly painted compolete including cutting & making good the wall:
765WVC (I.S.: 2556 Mark) size 530 x 450mm
766Mosaic fine polished size 600 x 450
767P & F 1st quality WVC pedestal for wash basin.
768P & F Bottle Trap of approved make :
769C.P Brass 32 mm
770C.P Brass 40 mm
771Synthetic Material (PTMT)32 mm
772Synthetic Material (PTMT)42 mm
773P.V.C
774P& F waste Coulping with fittings of approved quality /make:
775C.P Brass 32 mm dia
776C.P Brass 40 mm dia
777C.P. Brass 50 mm dia
778SS 125 mm
779P& F waste Pipe with all fitting
780P.V.C with C.P nut 32 mm
781P.V.C with PVC nut 32 mm
782P.V.C. with C.P. nut 40 mm dia
783G.I(B class) 32mm
784G.I(B class) 40 mm
785P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers.
786Size 600 x 450mm x 4 mm thick
787Other sizes deduct 30%
788P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge
789Size 500x400mm
790Oval shape 450x350 mm
791Round 500mm dia deduct 30%
792P & F Toilet Shelf of approved quality/make:
793W.V.C. (I.S.: 2556 Mark) Size 300mm
794W.V.C. (I.S.: 2556 Mark) Size 550 mm
795Synthetic Material with tumbler of approved quality/make size 470 x 114 x 36mm
796Hard Plastic of approved make as per direction of EI of size 590x140mm
797Acrylic shelf on C.P. brass casted brackets & guard rail of approved make as per direction of EI of size 550x125mm
798Glass Shelf with edges rounded off Anodised Aluminium angle frame & C.P. brass brackets & guard rail size Each 600x120mm
799P & F Towel Rail or Ring of approved quality/make:
800C.P. brass Towel Rail elbow type with concealed screws size 450mm (Heavy duty).
801C.P. brass Towel Rail elbow type with concealed screws size 600 mm (Heavy duty).
802C.P. brass towel rail with brackets 450 x 20mm.
803C.P. brass towel rail with brackets 600 x 20mm.
804Synthetic Material(PTMT) of approved quality/make size 525 x90 x 75mm
805Synthetic Material(PTMT) of approved quality/make size 675 x90 x 75mm
806WVC (1stquality, IS2556 Marked) of approved make. Recessed towel Hanger size 108 x 108mm.
807C.P. Brass Towel Ring revolving type
808Synthetic Material (PTMT) Towel Ring of approved quality/make.
809P & F Grating of approved quality/make:
810Stainless Steel Sheet size 125mm dia.
811Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make
812Synthetic Material(PTMT) of approved quality/make size 125mm dia.
813(-do-) 150mm dia.
814(-do-) Square 150 x 150 x 8mm. (Anti Cockroach)
815C.P. brass with frame (Heavy) & superior quality size 125mm dia.
816(-do-) Light & superior quality size 125mm dia
817Cast Iron.
818P & F Liquid Soap Container with brackets complete of approved make:
819C.P. brass
820Synthetic Material of approved quality/make:
821P & F Tooth Paste & Brush Holder of approved quality/make:
822C.P. brass
823C.P. brass (Heavy and Superior quality)
824Stainless Steel
825P & F Toilet Paper Holder with rod of approved quality/make:
826C.P. brass
827C.P. brass heavy & Superior quality.
828WVC (1stquality, IS 2556 Marked) recessed size 150x150mm.
829(-do-) exposed (-do-)
830P & F Soap Dish or Tray of approved quality/make
831C.P. brass
832C.P. brass heavy and superior quality.
833WVC (1st Quality, IS 2556 Marked) recessed size 150 x 150 mm.
834(-do-) 200 x100mm.
835(-do-) Soap tray 170mm.
836(-do-) Soap Dish 380mm.
837P & F Twin- peg of approved quality / make
838C.P. brass
839C.P. brass (heavy)Superior quality
840Acrylic
841P & F Shower arm 15mm dia of approved quality/make.
842C.P.brass heavy & superior quality 150mm Projection.
843(-do-) size 220mm(-do-)
844(-do-) size 300mm.(-do-)
845(-do-) size 370mm.(-do-)
846P & F Bath Shower of approved quality/make.
847C.P. brass fixed.
848C.P. brass of Heavy & superior quality 150mm.
849C.P. brass of Heavy & superior quality, revolving with adjustable key 150mm.
850P & F Extension Pipe for bib cocks of approved quality/make.
851C.P. brass of Heavy & Superior quality 50x15mm
852(-do-) 100 X 15mm.
853(-do-) 150 X 15mm.
854P & F Acrylic Toilet accessories set consisting of Towel rail, shelf, towel ring, soap dish, paste & brush holder & twin peg of approved quality/make.
855Labour Charges for removing WVC pan:
856Indian/Orissa pan
857European W.C.
858Flushing cistern
859P & F Jet spray for water closet with C.P. Copper Tube flange of approved make.
860Providing & fixing C.P.flange for 15mm dia taps.
861Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
862Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
863Extra for using Marble printed / Granite shade or dark Sqm 10% shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles.
864Extra for using size above 200x300mm in glazed tiles and Sqm 10% for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size.
865P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in- Charge
866P & F C.P. brass Urinal Spreader for Large Urinal of heavy duty of approved make as per direction of Enginner-in- Charge
867Removing & Re fixing of P.V.C. Cistern fittings (Syphon, Ball cock & Handle Set) complete as per direction of Enginner-in-Charge
868Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor.
869W.C. orissa pan with 100 mm vitreous china P or S trap (Size 580x440 mm.)
870Universal (anglo-Indian type) with P or S trap
871Wall Mounting European type W.C.
872Double Syphonic European W.C. with mounted W.V.C. flushing cistern of 10 litre capacity complete with all necessary internal fittings with Hydraulic seat cover.
873Providing & Fixing premium qulaity WVC Urinal with PVC waste pipe, dome couplings, concealed iron brackets or screws etc. complete.
874Flat Back (small) size 440x265x315 mm. 1..69.2 Flat Back (large) or half stall size 590x375x390 mm. Each 7133.00
875Providing & Fixing premium qulaity W.V.C. Urinal Partition plate of size 630x315 mm
876Providing & Fixing premium qulaity WVC Wash basin with C.I. brackets duly painted & 32 mm C.P. brass waste coupling of approved make with PVC waste pipe complete
877Size 550 mm x 400 mm
878Size 550 mm x 400 mm dia for counter top.
879P & F Premiumquality water closet Seat Covers with brass hinges complete Solid PVC (ISI marked) grade-I White for
880P & F Premium quality Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make as per Engineer-in-charge with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall :
881P&F Looking Mirror 5mm thick of approved make with ornamental frame size 50x12 with 6mm Ply Board on Back Side Complete as per approved sample
882Supply of Hydraulic Seat Cover for Europeon WC of superior quality approved make in white Colour
883Providing & Fixing chair for wall hung W.C.
884Providing & Fixing Concealed cistern with Floor mounting frame and flush plate of superior quality and approved sample by Engineer-in-charge.
885Providing and fixing new spindle for Bib cock/pillar cock for repairing purpose to solve leakage and proper functioning of tap.
886Providing & Fixing premium quality Toilet corner Glass Shelf size 225x225mm with C.P. brass brackets & guard rail edges rounded of SS frame
887Providing & Fixing premium quality waste coupling 32mm half thread as per approved by Engineer in Charge.
888Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flange as per approved by Engineer in Charge.
889P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: (a) Exposed on wall
89015 mm dia nominal bore 'A' Class 'B' Class Mtr. 271.00
89120mm dia nominal bore 'A' Class 'B' Class Mtr. 334.00
89225mm dia nominal bore 'A' Class 'B' Class Mtr. 423.00
89332mm dia nominal bore 'A' Class 'B' Class Mtr. 515.00
89440mm dia nominal bore 'A' Class 'B' Class Mtr. 637.00
89550mm dia nominal bore 'A' Class 'B' Class Mtr. 793.00
89665mm dia nominal bore 'A' Class 'B' Class Mtr. 951.00
89780mm dia nominal bore 'A' Class 'B' Class Mtr. 1139.00 (b) Concealed pipe in wall including painting with anticorrosive bitumen paint
89815 mm dia nominal bore 'A' Class 'B' Class Mtr. 280.00
89920mm dia nominal bore 'A' Class 'B' Class Mtr 329.00 2.1.11 25mm dia nominal bore 2.1.11.1 A' Class Mtr 369.00 2.1.11.2 B' Class Mtr 480.00
90025 mm dia (a) The rates are for ISI marked item. (b) If the items are Non- ISI marked, reduce the rate by 25%.
901P & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make:
902C.P. Pillar cock, 15 mm dia nominal bore
903C.P. Pillar cock Elbow action, 15 mm nominal bore.
904C.P. Pillar cock fancy type ,15mm nominal bore.
905C.P. Pillar cock, Swan-neck with casted spout, 15mm nominal bore.
906C.P. Pillar cock, high-neck, 15 mm nominal bore.
907Synthetic Material (PTMT) Pillar cock of approved quality / make 15mm nominal bore.
908P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:
909Brass 400 gm,15mm nominal bore.
910P.V.C.heavy duty, 15mm nominal bore.
911C.P. Brass bib cock,15mm nominal bore.
912(-do-) Long body, 15mm nominal bore weight not less than 690 gm
913(-do-) Long nose, 15mm nominal bore weight not less than 810 gm
914(-do-) Elbow-action, 15mm nominal bore.
915Synthetic Material(PTMT) bib cock of approved quality/ make, nominal bore, 15mm, 86 mm long.
916(-do-) Fancy Type, 122 mm long.
917(-do-) Long Body, 175 mm long
918P & F Stop Cock (IS :8931 Mark), superior quality & of approved make:
919Brass 400 gm. 15mm nominal bore.
920(-do-) 750 gm. 20 mm nominal bore.
921(-do-) 1350gm. 25 mm nominal bore.
922C.P. Brass 15mm nominal bore.
923(-do-) Concealed Stop Cock 15mm.
924Synthetic material (PTMT) stop cock of approved quality/make 15mm.
925(-do-) Concealed stop cock 15mm
926P & F Sink Cocks of superior quality & approved made :
927C.P. Sink cock swinging spout 15mm.
928(-do-) Casted Spout 15 mm.
929P & F Push Cock superior quality, of approved make 2..10.1 C.P. Brass 15 mm.
930Synthetic Material (PTMT) push cock of approved quality/make 15mm.
931P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :
932Brass wt. Not less than 300 gm,15mm.
933Brass wt.Not less than 400 gm, 20mm.
934(-do-) wt.Not less than 600 gm, 25mm.
935(-do-) wt.Not less than 800 gm, 32mm.
936(-do-) wt.Not less than 1000 gm 40mm.:
937(-do-) wt.Not less than 1200 gm 50mm.
938Synthetic material (PTMT) of approved make 15mm nominal size.
939(-do-) 20 mm nominal size.
940(-do-) 25 mm nominal size.
941(-do-) 50 mm nominal size.
942P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.
943C.P. Inlet connection 15mm.Brass (IS : 8931 marked)
944---do--- with 37 cm long pipe and nut.
945---do--- with 60 cm long thread and nut
946Synthetic Material (PTMT) Inlet connection of approved quality/make 15 mm nominal size.
947P & F 15 mm. Dia Connection Pipe of approved quality/make :
948PVC pipe with C.P. Brass nuts upto length, 300mm
949(-do-) upto length 370mm
950(-do-) 450mm.
951(-do-) 600mm.
952P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :
953CP brass push type 15mm nominal bore.
954(-do-) 20mm nominal bore.
955(-do-)exposed 25mm nominal bore.
956(-do-) 32mm nominal bore.
957(-do-) concealed 25mm nominal bore.
958(-do-) concealed 32mm nominal bore.
959(-do-) Half-turn exposed 25mm nominal bore.
960(-do-) Concealed 25mm nominal bore.
961Brass / Gun metal Half-turn wt. 1 Kg. of approved quality / make, 25mm nominal bore.
962CP Brass flush valve 32mm nominal bore
963P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :
964Gun-metal 15mm nominal bore.
965(-do-) 20mm nominal bore.
966(-do-) 25mm nominal bore.
967(-do-) 32mm nominal bore.
968(-do-) 40mm nominal bore.
969(-do-) 50mm nominal bore.
970(-do-) 65mm nominal bore.
971(-do-) 80mm nominal bore.
972(-do-)100 mm dia nominal bore
973P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:
974300 (-do-)
975500 (-do-)
976750 (-do-)
9771000 (-do-)
978Hoisting Charges for each floor :
979For items 2.26.1 to 2.26.4
980For items 2.26.5 to 2.26.8
9813240 (40mm OD) pipe
982Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge
983Pillar Cock 15 mm nominal size
984Swan neck pillar cock 15 mm nominal size
985Bib Cock with long thread 15 mm nominal size
986Long body Bib Cock 15 mm nominal size
987Two way Bib Cock 15 mm nominal size
988Angular stop cock with long thread 15 mm nominal size
989Stop cock long thread
990Stop cock with reduced body
991Concealed stop cock 15 mm nominal size
992Sink cock with swinging casted spout (table mounted ) 15 mm nominal size
993Single lever wash basin mixer with 450 mm long copper connection pipe
994Central hole basin mixer
995Jet Spray
996PN-16 Pipe, 20 mm OD
997PN-16 Pipe, 25 mm OD
998PN-16 Pipe, 32 mm OD
999PN-16 Pipe, 40 mm OD
1000PN-16 Pipe, 50 mm OD
1001PN-16 Pipe, 63 mm OD
1002Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)
100315 mm nominal outer dia pipes
100420mm nominal outer dia pipes
100525 mm nominal outer dia pipes
100632mm nominal outer dia pipes
100740 mm nominal outer dia pipes
100850 mm nominal outer dia pipes
1009Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)
101015 mm nominal outer dia pipes
101120mm nominal outer dia pipes
101225 mm nominal outer dia pipes
101332mm nominal outer dia pipes
1014Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).
101515 mm nominal outer dia pipes
101620mm nominal outer dia pipes
101725 mm nominal outer dia pipes
101832mm nominal outer dia pipes
101940 mm nominal outer dia pipes
102050 mm nominal outer dia pipes
1021Providing and fixing premium quality Angular stop cock 15mm with wall flange complete as per sample approved by Engineer in charge
1022Providing and fixing premium quality Two way Bib cock 15mm with wall flange complete as per sample approved by Engineer in charge
1023Providing and fixing superior quality PVC Tank Cover complete as per approved by Engineer In Charge
1024300 Lt. capacity
1025500 Lt. capacity
1026Above 500 Lt. capacity
1027Supply and installation of Premium quality sluice valve 100mm dia including all fittings as per approved by Engineer in charge.
1028P&F Sink Mixture of (Adjustable or Non Adjustable) Superior quality Swan Neel
1029For laying of S.W. pipes beyond 1.2m depth, earthwork & close timbering or open timbering (as per site conditions) is to be paid extra.
1030P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.
1031Trap size 150 X 100mm, ferrow cement cover with frame, Internal Each Chamber size 300 X 300mm.
1032Trap size 225 X 150 mm, ferrow cement cover with frame Internal Each Chamber size 450 X 450mm.
1033P & F S.W. Master Trap (Inter-cepting) `A` grade (I.S.: 651 marked) of approved quality/make
1034100mm dia
1035150mm dia
1036Labour charges for Removing S.W. pipes including breaking of joints & bed concrete, stacking of useful material at site within 50 mtr. Lead and disposal of unserviceable material within 0.5 Km. lead:
1037100 & 150mm dia pipe
1038200, 230 & 250mm dia pipe
1039300mm dia pipe
1040350mm dia pipe
1041400mm dia pipe
1042P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.
104363 mm dia
104475 mm dia
1045110 mm dia
1046160 mm dia
1047Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation of trenches etc.
1048PVC pipe 110 mm dia
1049PVC pipe 160 mm dia
1050P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:
1051Coupler (socket) (i) 75mm dia (ii) 110mm dia Each 118.00 (iii) 160 mm dia Each 129.00
1052Reducer 110 X 75 mm (i) 75mm dia (ii) 110mm dia Each 107.00 (iii) 160 mm dia Each 124.00
1053Plain Tee (i) 75mm dia (ii) 110mm dia Each 199.00 (iii) 160 mm dia Each 218.00
1054Door Tee (i) 75mm dia (ii) 110mm dia Each 226.00 (iii) 160 mm dia Each 242.00
1055Door 'Y' (i) 75mm dia (ii) 110mm dia Each 244.00 (iii) 160 mm dia Each 260.00
1056Double 'Y' (i) 75mm dia (ii) 110mm dia Each 316.00 (iii) 160 mm dia Each 336.00
1057Double Door 'Y' (i) 75mm dia (ii) 110mm dia Each 399.00 (iii) 160 mm dia Each 415.00
1058Bend 45 (i) 75mm dia (ii) 110mm dia Each 130.00 (iii) 160 mm dia Each 146.00
1059Bend 87.5 (i) 75mm dia (ii) 110mm dia Each 164.00 (iii) 160 mm dia Each 180.00
1060Door Bend (Top Side) (i) 75mm dia (ii) 110mm dia Each 157.00 (iii) 160 mm dia Each 175.00
1061Door Bend (Left & Right) (i) 75mm dia (ii) 110mm dia Each 199.00 (iii) 160 mm dia Each 215.00
1062Vent Cowel (i) 75mm dia (ii) 110mm dia Each 57.00 (iii) 160 mm dia Each 78.00
1063Socket plug (i) 75mm dia (ii) 110mm dia Each 83.00 (iii) 160 mm dia Each 103.00
1064Door Cap (i) 75mm dia (ii) 110mm dia Each 63.00 (iii) 160 mm dia Each 81.00
1065Pipe Clip (i) 75mm dia (ii) 110mm dia Each 37.00 (iii) 160 mm dia Each 54.00
1066W.C. connector with lipring 110mm dia
1067W.C. connector bent type 110mm dia
1068Plain floor trap 110mm dia
1069Multi floor trap 110mm dia
1070height Raiser 110mm dia
1071Top Tile& straine 110mm dia
1072Top Tile only 110mm dia
1073P- Trap 110mm dia
1074Q- Trap 110mm dia
1075S- trap 110mm dia
1076Ring fitting 110mm dia 3.17.274 Gully trap 110mm dia Each 571.00
1077Raising manhole cover and frames slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole masonry to be paid separately).
1078Rectangular manhole 90x60 cm
1079Rectangular manhole 150x120 cm
1080Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.
1081Depth up to 0.5 M
1082Add extra over item 3.19.1 for every additional 0.10m depth above 0.5 m depth.
1083Deduct in Item No 3.19.1 for manhole with brick work 230 mm thick in place of 300 mm thick stone masonry
1084Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :
1085Depth up to 1.5 M
1086Add extra over item 3.20.1 for every additional 0.10m depth above 1.5 m depth .
1087Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.
1088Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame.
1089Deduct for using brick work 230 mm thick in place of 300 mm thick stone masonry
1090-do- size 450 x 450mm depth upto 0.5 M Cement cover with frame
1091Deduct for using brick work 230 mm thick in place of 300 mm thick stone masonry
1092-do- size 600 x 450mm depth upto 0.5 M Cement cover with frame.
1093Deduct for using brick work 230 mm thick in place of 300 mm thick stone masonry
1094-do- depth upto 0.5 M to 1.0 M –do-
1095Deduct for using brick work 230 mm thick in place of 300 mm thick stone masonry
1096Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:
1097Size 300 Cm. dia outside & 300 Cm. depth .
1098-do- & 240 Cm. Depth.
1099Size 240 Cm. dia outside & 240 Cm. depth.
1100Construction of soakage Trench in all types of soil with 300 mm thick dry stone masonry, 80 mm thick stone slab covering, jointing of slab in CM 1:3 Ralthal, Kharanja, 40 mm thick M-15grade C.C. flooring earthwork etc. complete as per approved drawing including disposal of earth within a lead of 50 Mtr.:
1101Top width 180Cm., bottom width 90Cm. & depth 240Cm.
1102-do- 240 Cm., -do- 150Cm. & depth 300 Cm
1103Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr .
1104Inner dia 90 Cm & 10 to 12 Mtr deep.
1105Inner dia 60 Cm & 10 to 12 Mtr deep.
1106Labour charges for construction of Soakage well of 90 Cm. dia (Earth – work & its disposal ,with in a lead of 0.5 Km .only ).
1107Add extra if Soakage Well is filled with dry stones.
1108Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-
1109Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab Each with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
1110Size 230 x110 x150 cm.(for 20 users) with 115 mm thick RCC (M-20) Each slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
1111Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) Each slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. Depth -18 % each
1112Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site.
1113Add extra if R.C.C slab of designed thickness & reinforcement is provided on manhole in place of stone slab( Actual area of R.C.C slab to be measured).
1114P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete.
1115Supplying and fixing C.I. Cover with frame, C.I. gratings for chambers & man holes.
1116Supplying and fixing Ferro- cement cover with C.I. frame for chambers & man holes of size.
1117450mm dia, 5Kg. C.I. frame to with stand 3 MT center point load & minimum unfractured load of 1 MT. (Light duty).
1118500mm dia 12 Kg.-do-15 MT centre point load (medium duty).
1119500mm dia 22 Kg.-do-22 MT centre point load (Heavy duty).
1120500mm dia 25 Kg.-do-70 MT centre point load seal type (Heavy duty.)
1121Rectangular shape 600 x 450 mm, to withstand 3 MT center point load & minimum unfractured load of 1 MT. (Light duty).
1122Supplying & Fixing R.C.C. Manholes covers with frame of approved make (Light duty).
1123Size 500mm dia (Double seal)
1124Size 450mm dia
1125Size 400mm dia
1126Size 600 X 600mm (Double seal)
1127Size 600 X 450mm
1128Size 450 X 450mm
1129Size 300 X 300mm
1130Size 250 X 250mm
1131Size 180 X 180mm
1132150mm with door (i) Bend (ii) Door Cross Each 2989.00 (iii) Tee Each 2164.00
1133Providing and Fixing Spun –Cast Iron floor trap (Nahani) of (IS :3989 Mark ) approved quality / make with socket down or hinged grating including cutting and making good the floor :-
1134Size 100 x 100 mm
1135Size 100 x 75 mm
1136Add 10% extra Over Item No. 3.41 if the pipes are laid under suspended condition under the roof.
1137Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
113875 mm dia
1139110 mm dia
1140Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
1141Coupler (i) 75mm dia (ii) 110mm dia Each 114.00
1142Repair Coupler (i) 75mm dia (ii) 110mm dia Each 132.00
1143Single Push Fit Coupler (i) 75mm dia (ii) 110mm dia Each 135.00
1144Bend 87.5 Dg. (i) 75mm dia (ii) 110mm dia Each 164.00
1145Bend 45 Dg. (i) 75mm dia (ii) 110mm dia Each 140.00
1146Door Bend 87.5 Dg. (i) 75mm dia (ii) 110mm dia Each 205.00
1147Single 'Y' (i) 75mm dia (ii) 110mm dia Each 295.00
1148Single 'Y' with Door (i) 75mm dia (ii) 110mm dia Each 369.00
1149Double 'Y' (i) 75mm dia (ii) 110mm dia Each 374.00
1150Double 'Y' with Door (i) 75mm dia (ii) 110mm dia Each 485.00
1151Socket Plug (i) 75mm dia (ii) 110mm dia Each 76.00
1152Pipe Clip (i) 75mm dia (ii) 110mm dia Each 33.00
1153Double tee with Door (i) 75mm dia (ii) 110mm dia Each 606.00
1154W.C. Connector 110mm dia
1155W.C. Connector (Bend) with ring 110mm dia
1156Single Tee (i) 75mm dia (ii) 110mm dia Each 223.00
1157Single Tee with Door (i) 75mm dia (ii) 110mm dia Each 256.00
1158Double Tee (4 Ways) (i) 75mm dia (ii) 110mm dia Each 389.00
1159Offset 110mm dia
1160Extra Square Jali 110mm dia
1161Extra Round Jali 110mm dia
1162Gully Trap 110mm dia
1163Nahni Trap with Jali 4” 110mm dia
1164Nahni Trap without Jali 4” 110mm dia
1165Nahni Trap with Jali 3” 75 mm dia
1166Nahni Trap without Jali 3” 75 mm dia
1167Vent Cowel 110mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58229290
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1 Crore
LAST DATE 04-11-2026
Authority
Authority Name Rajasthan Council Of School Education
Work Description Tender for Annual Rate Contract For Repair And Maintenance Works Block- Bijoliya
Basic Detail
Tender No NIT-17/2026-27-SMSA BHILWARA
Bidding Type Tender
Location
City Bhilwara
State Rajasthan
Key Dates
Publish Date 27 Oct 2026
Submission Date 04 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 1 Crore
Tender Fee 1000
EMD 2 Lakhs
Exemption Not Available
Document List
BOQ_1072773.xls
f3833989-37c2-4ef4-846d-7ee87d564fb7.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf
Tendernotice_7.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1072773.xls

html

f3833989-37c2-4ef4-846d-7ee87d564fb7.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf

pdf

Tendernotice_7.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender