Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58228738

Tender For Special Repairs To Building No P-86 At installation Hamla Under Ge (Nw) Bhandup

Issued by Statutory Bodies & Commissions/Committees · Mumbai Suburban, Maharashtra
Tender Value
23.80 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
20 days left
EMD
47600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Building No P-86 At installation Hamla Under Ge (Nw) Bhandup

BOQ

Name of Work:- SPECIAL REPAIRS TO BUILDING NO P-86 AT INS HAMLA UNDER GE (NW) BHANDUP
Sl. No. Item Description
1Taking down cement plaster of any description in any position including racking out joints making key scrubbing down with water etc. and removal of debris outside MD land complete all as specified and directed.
2M & L for 10 mm thick rendering in CM (1:3) on fair faces of concrete surfaces of ceiling on plastered ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
3M & L for 15 mm thick plastering in CM (1:6) on fair faces of brick work or concrete surfaces and provision of 3 mm thick wall care putty on plastered surfaces of wall, surfaces finished even and smooth without using extra cement complete all as specified and directed.
4M & L for 15 mm (10+5) thick rendering in CM (1:4) using WPC @ 2% by weight of cement on brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.Note : Water proofing compound shall be measured & paid seperately.
5Supply only integral water proofing compound complete all as specified and directed.
6Demolition of brick work built in CM including taking out roots vegetation if any at any position and removal to outside MD land complete all as specified and directed.
7M & L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius built in CM (1:6) complete all as specified and directed.
8M & L for 75 mm PCC (1:3:6) type C2 thick as in plinth protection finished even and smooth using extra cement and making joints at three metre interval and filling bitumen compete all as specified and directed.
9Taking down chowkats without taking off shutters from the frame area not exceeding 1.50 sqm each complete all as specified and directed.
10Taking down chowkats without taking off shutters from the frame exceeding 1.50 sqm and not exceeding 4.00 sqm complete all as specified and directed.
11Taking down shutters of any description exceeding 1.00 sqm not exceeding 2.00 sqm complete all as specified and directed.
12S & F second class hardwood plain solid straight chowkats and framed rebated on the solid rounded put together with glue pinned at joints complete all as specified and dirtected.
13S & F second class hard wood 35 mm thick factory made plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial or 12 mm veneered particle board with commercial veneer on both faces the size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressured treated complete all as specified and directed.
14M & L for Aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples or wooden / aluminium beading complete all as specified and directed.
15S & F second class HW 35 mm thick glazed and skeleton shutters, open rebated and pepared to receive glass, gauze, etc with sash bar, edges of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass, gauze etc sizes of members of shutters as specified in SSR part-1 section 8, clause 8.24 (a); complete all as specified and directed.
16M & L for painting with synthetic enamel paint of two coat over a coat of pink primer on new wooden surfaces of any description exceeding 10 cm width or girth including preparation of surfaces complete all as specified and directed.
17M & L for applying one coat of synthetic enamel paint on old wooden surfaces of any description exceeding 10 cm width or girth including preparation of surfaces complete all as specified and directed.
18M & L for MS hold fasts size 25 x 6 mm FI fixed to chowkats complete all as specified and directed.
19M & L for providing PCC (1:2:4) type B1 cement concrete in bed blocks for hold fasts complete all as specified and directed.
20S & F stainless steel butt hinges heavy weight 100 mm long complete all as specified and directed.
21S & F aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
22S & F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
23S & F extruded aluminium alloy handles, fabricated type, anodised 150 mm size complete all as specified and directed.
24M & L for 20 to 25 mm machine cut kota stone slab as in riser of steps, skirting, dado and pillar, cills and jambs laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beewax polish and including over 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and as directed by Engineer in charge.
25S & F for anodized aluminium section in frame or shutters of window, doors and partition with aluminium section (medium weight) of suitable size as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plasted steel screws and all necessary fitting, screw, plug for fixing screws locking arrangement etc complete all as specified and directed. Note:- The rates of glass pane, wire mesh will be measured and paid separately.
26S & F 4.8 mm thick glass selected quality in each pane for aluminimum door shutters, aluminium partition wall and sliding windows / ventilator shutters etc including rubber beading or gasket for aluminium section complete all as specified.
27S & F anodised aluminium grill DG- 102 (10 mm x 5.2 mm) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1 mm thick of approved make complete all as specified and directed.
28S & F solid PVC door frame (chowkhat) of size 50 mm x 47 mm made out of 5 mm plain dark colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
29S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain dark colour PVC 'C 'Channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain dark colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rail with suitable PVC sheet beading and joined together with solvent cement, etc fixed to frame complete all as specified and directed.
30S & F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor of 140 mm size complete all as specified and directed.
31S & F in repair PVC flushing cistern 10 litres capacity high / low level with inlet, ball valve, float and handle including brackets complete all as specified and directed.
32Stage 1: Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debries outside MD land etc complete all as specified and directed.Stage 2: Providing 15 mm thick plaster in CM 1:3 mixed with integral water proofing chemical of STP Ltd in the proportion / quantity all as per manufactures instructions. Note :- Rate inclusive of waterproofing compound.Stage 3 : Primer - Mix Tarfelt LM with water in ratio 1:1 @ 250 gms/sqm and apply the primer on the plaster surfaces. Stage 4 : Application of 1 st coat of Tarfelt LM of STP Ltd without dilution with water @1kg/sqm by brush complete all as per manufactures instructions.Stage 5: Laying 50 GSM fyber glass cloth over the 1st coat while the coated surface is still tacky.Stage 6: After 6 to 7 hours interval apply second coat i.e final coat of Tarfelt LM without dilution with water of STP Ltd by brush as per manufactures instructions @1kg /Sqm
33M & L for cement concrete (1:5:10) type E2 using 40 mm graded aggregate as in lean concrete complete all as specified and directed.
34S & F in repairs vitreous china wash down water closet pan (padestal pattern), white including seat cover and connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specified and directed.
35S & F WC connector 110 mm PVC SWR for WC complete all as specified and directed.
36S & F in repairs PVC valveless, syphonic action type, 10 litres capacity flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe 32 mm dia complete all as specified and directed.
37Supply only PVC connector 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
38M & L in repair for stainless steel floor trap, plain with grating removeable & refixable type including jointing with solvent cement 100 mm dia of outlet complete all as specified and directed.
39S & F in repair mirror 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
40S & F in repairs stainless steel sink with drainage board made of stainless steel 1 mm thick kitchen or labouratory with plugs, washers, and wastes. including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm X 460 mm and bowl size 410 mm x 330 mm x 160 mm including necessary fittings such 40 mm coupling waste, pipe complete all as specified and directed.
41S & F in repair wash basin, Vitreous China white (Flat back) 630 x 450 mm including brackets, pinning in ends of brackets or erecting stand including fixing of waste pipe and pillar type etc complete all as specified and directed.Note : Suppy of pillar tap and waste pipe shall be measured and paid separately.
42Supply only pillar tap 15 mm dia cast copper alloy chromium plated fancy type complete all as specified and directed.
43M & L for waste fitting of 32 mm bore, brass, chromium plated for glazed ware wash basin etc complete all as specified and directed.
44S & F in repairs stop valves 15 mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
45S & F low density polyethlene (LDPE) pipe of pressure rating 6 Kgf / Sqcm 40 mm dia complete all as specified and directed.
46S & F in repairs bib tap brass 15 mm bore dia chromium plated long shank fancy type with curtch or butterfly handle, screwed down, screwed for iron pipes complete complete all as specified and directed.
47S & F in repairs brass chromium plated towel rail 20 mm dia, \\"D\\" type, 600 mm long between flanges complete all as specified and directed.
48S & F in repair stainless steel soap dish approximate size 160 mm x 160 mm x 90 mm complete all as specified and directed by Engineer-in-Charge.
49S & F in repairs glass assembly sheet glass consisting of 5.5 mm thick sheet glass 12 cm wide with chromium plated bracked guard and railing 60 cm long complete all as specified and directed.
50S & F in repairs brass chromium plated shower rose 125 mm size including fixing to steel pipe or union complete all as specified and directed.
51Taking up or down steel tubing 15 mm bore of pipe and connections including cleaning for refixing etc as required complete all as specified and directed.
52All as per item no. 51 above but 25 mm bore of pipe complete all as specified and directed.
53M & L for tubes medium grade galvanised, with all fittings and fixed complete to walls or ceiling or laid in floors 15mm bore dia complete all as specified and directed.
54All as per item no. 53 above but 25 mm bore dia complete all as specified and directed.
55S & F in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed bore of 25 mm complete all as specified and directed.
56M & L in repairs for 2000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position complete all as specified and directed.
57M & L in repairs for 25 mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
58S & F in repairs 40 mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
59Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc complete all as specified and directed.
60M & L for glazed ceramic tiles in vertical surface 350 x 250 x 7mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
61Material and Labour non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not excceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer 15 mm thick for laying floor finishes in CM (1:6) complete all as specified and directed.
62M & L for vitrified ceramic tiles 8-10 mm thick light shade (Square / rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors over and including provision of cement screed bedding layer 20 mm thick in CM (1:4) etc set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
63Taking down 100 mm cast iron soil waste pipe moulding all fittings heads, shoes, bends etc. complete all as specified and directed.(Measured over all as fixed along the conference line over fittings and accessories).
64S & F 100 mm dia CI spun cast iron pipe jointed with cement joint and fixed to walls including cutting of holes wherever required complete all as specified and directed.
65S & F 100 mm dia CI bends including cutting of holes complete all as specified and directed.
66S & F 100 mm dia CI branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches and cutting of holes with cement joints complete all as specified and directed.
67S & F CI cowl 100 mm dia complete all as specified and directed.
68S & F in repairs 20 mm dia aluminium alloy curtain rail fixing with pair of brackets, stops, rollers etc complete all as specified and directed.
69M & L for leakage / seepage proof coating consisting of preparing the new surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8 hours before application of next coat) including necessary scaffolding etc all as per manufacturer instructions and complete all as specified & directed.Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
70M & L for leakage / seepage proof coating consisting of preparing the old surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100 microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8 hours before application of next coat) including necessary scaffolding etc all as per manufacturer instructions and complete all as specified & directed.Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
71M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over one coat of alkali resistant primer finish.etc complete all as specified and directed.
72M & L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of oil bound distemper over a coat of primer finish etc complete all as specified and directed.
73M & L for preparation of new plastered surfaces on ceilings and applying two coats of oil bound distemper with roller over complete all as specified and directed.
74M & L for complete removal of existing surfaces on ceiling and applying two coats of oil bound distemper with roller over application of putty complete all as specified and directed.
75Taking down AC rain water pipe any size or pattern including all fittings heads, shoes, bends, swan necks, etc including cleaning for refixing or removing to store complete all as specified and directed.
76M & L for 110 mm dia PVC rain water pipe single socketed (ISI marked) fixed fixed to wall with mild steel clamps including complete fittings such as heads, bends, shoes, swan necks etc. complete all as specified and directed.
77Dismantling of boarding, any description and in any position complete all as specified and directed
78M & L for 18 / 19 mm thick prelaminated particle board with teak wood beading, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
79M & L for second class hardwood moulding not exceeding 6 sqcm as in cornices, picture rails and the like such as in prelaminated particle board complete all as specified and directed.
80S & F 30 mm width of flange continous (piano) hinges, mild steel, bright finish or electro-galvanised complete all as specified and directed.
81S & F 75 mm size hasp & staple, aluminium anodised, safety type, including bolt to hinge plate and fixed with screws complete all as specified and directed.
82Chipping, removing, carefully concrete including loose palster by low impact hammer without damaging the structure and cleaning and disposal of debris outside the premises including necessary formwork ie providing & erecting steel props, safety nets, dust control net, self supported two legged B class tubular steel scaffolding, 4 mm thick ply covering to machineries / other utilities etc complete all as specified and directed.
83M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
84M & L for post construction anti-termite traetment along the external wall below concrete or masonary apron using chemical emulsion @2.25 litres per linear meter including drilling and plugging holes with cement morter (1:2) to match the existing floor etc complete all as specified and directed.
85S & F in repairs vitreous china squatting pain,\\"Orrisa\\" pattern WC of size 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe but including P or S trap and provision of lime concrete bedding complete all as specified and directed.Note: Flushing cistern and flush pipe will be measured and paid seperately.
86M & L for Marble work other than white or black / baroda green 18 to 20 mm thick (table rubbed and polished) in cooking platforms, jambs and like over and including provision of 20 mm thick cement mortar (1:4) including pointing in colour cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed.
87M & L for granite 18 to 20 mm thick (of any type) table rubbed and polished as in floor such as steps, window cills / jambs, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
88M & L for cleaning the existing reinforcement with wire / rotary wire brush, making the surfaces free from loose material dirt etc, and applying two coats of alkaline rust converting primer conforming to ASTM-B- 117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 1 hour between the coats complete all as specified and directed.
89M & L for providing and fixing additional steel bar in various structural elements like column, beams and slab etc including drilling, bending and fixing the bars tying with preleft binding wires etc complete anchoring reinforcement bar in existing RCC member in holes of minimum 10d depth for 8 to 12 mm dia bars complete all as specified and directed.
90M & L for applying anticorrosive treatment to reinforcement by IPNET RB and application of two coats of IPNET RB on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be by brush complete all as specified and directed.
91M & L for providing and applying structural grade epoxy-latex bond coat prior to application of any type of mortar conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
92M & L for building up the profile of structural members by using polymer modified mortar upto 20 mm thickness including levelling profilling etc complete all as specified and directed. Make:- Molith PMM of Krishna conchem or equivalent make as approved by GE. Note:- Mode of measurement : Superficial area of concrete will be measured.
93M & L for building up the profile of structural members by using polymer modified mortar upto 40 mm thickness including levelling profilling etc complete all as specified and directed. Make:- Molith PMM of Krishna conchem or equivalent make as approved by GE. Note:- Mode of measurement : Superficial area of concrete will be measured.
94Demolition of the existing brick coba treatment over roof slab completely including throughly cleaning complete all as specified and removal of the demolished material to outside MD land complete all as specified and directed.
95M & L for PCC (1:2:4) type B0 (using 12.5 mm graded aggregate) with water proofing 2% by weight of cement or as per manufacturer's instructions as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc complete all as specified and directed. Note :- Rate inclusive of waterproofing compound
96Supply and application of Seven layer SHR waterproofing coating system as per manufacture application procedure on leaking concrete roof surface by thorough surface preparation with high pressure water jet min.125 bars, opening the cracks, followed by one absorption coat of nano tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and minimum 50% solids, filling and sealing the cracks, then overcoating with one coat of NEEWP + cement mixture as waterproofing layer followed by sandwich coat of NEEWP + cement mixture as waterproofing layer with min 50GSM non woven fibre mesh then application of 4th coat of NEEWP +cement mixture elastomeric waterproofing layer +450% elongation. The surface is then to be tested for water tightness with ponding test for min 2 days and then top coated with 2 coats of SHR coating -pure acrylic based, UV resistant, non yellowing, bio organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with pull off adhesion 2.8 Mpa, Passes 2000 hrs accelerated durability test and other test as specified, suitable for all types of cementious surface, white colour, matt, surface coverage 3.25 sqm / Ltr / 2 coats, DFT 120 +/- microns using brush, roller, airless spray gun as applicable. The generic product should be GRIHA certified and application is to be done by the company approved applicator only complete all as specified and directed.
97M & L for post construction anti-termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 liters per linear meter including drilling and plugging holes with cement morter (1:2) to match the existng floor etc complete all as specified and directed.
98Demolition of reinforced brick work built in CM including taking out roots vegetation if any at any position and removal to outside MD land co mplete all as specified and directed.
99M & L for chequered cement concrete tiles with grey pigment cement and pigments 30 cm x 30 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors including 20mm screed bed cm (1:6) complete all as specified and directed.
100M & L in repair for stainless steel floor trap, plain with grating removeable & refixable type including jointing with solvent cement 100 mm dia of outlet complete all as specified and directed.
101S & F in repair anodised aluminium snap grid frame work for false ceiling (605 x 605 mm) complete all as specified and directed.
102S & F in repair semi perforated 12 mm thick micro tegular edged GRG (Glass fibre reinforced gypsum) false ceiling tiles complete all as specified and directed.
103S & F in repair hangers 6mm diameter GI (upto 1200 length adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasterns 12.5 mm dia 40 mm long complete all as specified and directed.
104S & F in repairs stainless steel sink with drainage board made of stainless steel 1 mm thick kitchen or labouratory with plugs, washers, and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm and bowl size 410 mm x 330 mm x 160 mm including necessary fittings such as 40 mm coupling waste, pipe complete all as specified and directed.
105M & L for white cement based wall care putty not less than 1 mm thick on wall celings new or old surfaces of any description finished even and smooth complete all as specified and directed
106M & L for two coat of synthetic enamel paint over a coat of aluminium red oxide primer to old steel surface including preparation complete all as specified and directed.
107S & F in mild steel angle iron cut to shape as directed drilling holes notching for wires as in post and struts in fencing, framed work, such as grills grating etc including all necessary cutting and welding etc and for similar work complete all specified and directed.
108S & F for mild steel screw bolts (machine cut) with hexagonal or square head at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long and diameter of neck 5 to 10 mm complete all as specified and directed.
109M & L in repair for PVC coated chain link fencing size not exceeding 40 x 40 mm. The dia of GI wire shall be 2.5 mm to 3 mm and thickness of PVC shall be 1 mm to 1.5 mm fixed to posts complete all as specified and directed
110M & L in repairs for rubberized FIFA quality Turf (or synthetic turf) requires a 50 mm pile height, non abrasive polythene fiber and an infill of silica sand with cryogenic rubber for cushioning, designed for durability and safety, these surfaces typically include UV inhibitors, high friction resistance, and excellent drainage, measuring the standard complete all as specified and directed.
111Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
112M & L for machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing polishing complete all as specified and directed.
113Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
114Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
115M & L for rolled sections as in framing like truss for cladding, glazing and the like fixed with angle cleats and connecting plates etc conforming to Fe 410-W (gde E250) complete all as specified and directed.
116S & F Prepainted galvalume aluminium zinc (150 micron) coating GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
117M & L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness , M-35 grade with grey cement and pigment complete ll as specified and directed.
118M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
119Taking down carefully copper / alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets & tube light fittings etc, removing materials from site or for reuse refixing & making good distrubed surface of wall, floors etc complete all as specified & directed.
120Taking down main switches from DBs with sheet metal enclosure 12 / 08 / 04 way SPN / TPN DBs etc complete all as specified & directed.
121M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in & including PVC conduit concealed in walls etc including cutting chases & making good the same in CM (1:3) to match with existing surfaces & partly drawn in & including PVC casing caping fixed on the surfaces of RCC slab / ceiling / columns / beams etc with all accessories, fittings, PVC junction boxes etc, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified & diretced for one light point / exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
122All as per item no. 122 above but for one 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and directed
123All as per item no. 122 above but for one 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and directed.
124All as per item no. 122 above but for one bell point controlled by one, one way switch 6 Amps complete all as specified and directed
125All as per item no. 122 above but for one ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and directed
126M & L for point wiring complete with proper colour coding using 1100 volts grade, 2.5 Sqmm, PVC insulated, FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in & including PVC conduit concealed in walls etc including cutting chases & making good the same in CM (1:3) to match with the existing surfaces & partly drawn in & including PVC casing caping fixed on the surfaces of RCC slab / ceiling / columns / beams etc with all accessories, fittings, PVC junction boxes etc. also including 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified & diretced for one 5 Pin, 6/16Amps, socket outlet independent complete all as specified & directed.Note for Item Ser No 122 to 127 : (i) Cutting chases for conduits and sinking's for GI metal switch boxes and making good to walls in cement mortar (1:3) to match with existing surfaces shall be carried out by the contractor without any extra cost from the department.(ii) Partially partly wiring in casing caping with all fittings accessories PVC junction boxes wherever concealed wiring is not possible on the surfaces of RCC slab / ceiling / columns / beams etc shall deemed to be included in the unit rate quoted against item.
127Supply and fixing modular switch, one way 6 A, one module, 230 Volts complete all as specified and directed.
128Supply and fixing modular Bell push 6A, one module 230 Volts complete all as specified and directed.
129Supply and fixing modular switch, one way 16 A, one module, 230 Volts complete all as specified and directed.
130Supply and fixing modular socket outlet multipurpose, 6A - 2/3 pin combined 2 module, 230 Volts complete all as specified and directed.
131Supply and fixing modular socket outlet multipurpose, 6A / 16A - 2/3 pin combined 2 module, 230 Volts complete all as specified and directed.
132Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and directed.
133Supply & fixing ceiling rose, surface bakelite 3 terminal complete all as specified & directed.
134Supply and fixing in repairs modular white cover plate with frame, to true size of the existing concealed metal box & make as per site requirement of 3 Module complete all as specified and directed.
135Supply and fixing in repairs modular white cover plate with frame, to true size of the existing concealed metal box & make as per site requirement of 4 module complete all as specified and directed.
136Supply and fixing in repairs modular white cover plate with frame, to true size of the existing concealed metal box & make as per site requirement of 6 module complete all as specified and directed.
137Supply and fixing in repairs GI metal flush boxes 1.2 mm thick,(18 Guage) 50 mm deep, with earth dolly, suitable for mounting modular white cover plate of size 3 module complete all as specified and directed.
138Supply and fixing in repairs GI metal flush boxes 1.2 mm thick, (18 Guage) 50 mm deep, with earth dolly, suitable for mounting modular white cover plate of size 4 module complete all as specified and directed.
139Supply and fixing in repairs GI metal flush boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, suitable for mounting modular white cover plate of size 6 module complete all as specified and directed.
140Supply and fixing in repairs LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
141Supply and fixing in repairs LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
142Taking down of existing ceiling fans, opening / dismantling of fan & fan blades, cleaning, servicing, oiling, greasing, carrying out repairs such as replacement of capacitors, bearings, bushes, canpoy, condensor, clamp, safety pin, rubber bush & reassembling the fan & fan blades, connecting up, testing & re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose / connector to fan & spray painting of ceiling fan with two coats of synthetic enamel paint after preparation of surfaces, complete all as specified & directed.
143Supply & fixing in repairs exhaust fan, steel body AC single phase, 230V of size 300 mm sweep with, blades & frame & louvers complete all as specified & directed. Note : Old exhaust fan should handover to MES store yard.
144Supply & fixing sheet metal enclosure powder coated for MCB DB SPN 12 way double door with din rail & bus bar including making good to the disurbed surface matching with the existing complete all as specified & directed.
145Supply & fixing in repairs MCB SPN 240 volts 32 Amps breaking capacity 10 KA 'B' Series rating complete all as specified & directed.
146Supply & fixing in repairs MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'B' Series rating complete all as specified & directed.
147S & F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
148Material & labour for earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5 mtr below normal ground lavel connected to GI wire 4 mm by mean of bolts, nuts, check nuts & washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit & CI cover fullel with watering pipe, wire mess & copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion complete all as specified & directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58228738
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 23.80 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Building No P-86 At installation Hamla Under Ge (Nw) Bhandup
Basic Detail
Tender No 8525/B
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 27 Oct 2026
Submission Date 17 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value 23.80 Lakhs
Tender Fee 500
EMD 47600
Exemption Available
Document List
BOQ_892733.xls
cf88b369-d85e-4d59-9ad6-929566231799.html
TENDERDOCUMENTS_8525.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_892733.xls

html

cf88b369-d85e-4d59-9ad6-929566231799.html

pdf

TENDERDOCUMENTS_8525.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender