Tender For Repair/Maintenance Of Hot Water Generator Control Wiring, Control Panels And Connected Works Of Various Ac Plants Under Ge(U) P&M Delhi Cantt-10
Tender Value
48.98 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
18 days left
EMD
97960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Hot Water Generator Control Wiring, Control Panels And Connected Works Of Various Ac Plants Under Ge(U) P&M Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Servicing and repairing of old unserviceable electrical operated hot water generator of different Capacity complete with automatic and safety controls such as safety valve, purge valve, high limit cut out, automatic and manual reset, low level cut out stop controller, thermostat, heaters including replacement of defective/ unsv parts with complete all as per specified and directed. |
| 2 | Supply and fixing in replacement of Hot water Generator (300 KW) Step controller with taking down old unserviceable one complete all as specified and directed. |
| 3 | Supply and fixing in relacement of Hot water generator (300 KW) digital display unit connected to controller with taking down old unserviceable one complete all as specified and directed. |
| 4 | Supply and fixing in replacement of Relay card of Hot water Generator (300 KW) with taking down old unserviceable one complete all as specified and directed. |
| 5 | Supply and fixing in replcement of Sensor wire of Hot Water Generator (300 KW) with taking down old unserviceable one complete all as specified and directed. |
| 6 | Supply and fixing in replacement of SMPS of Hot Water generator (300 KW) with taking down old unserviceable one complete all as specified and directed. |
| 7 | Supply & fixing in replacement of MCCB 4 Pole of capacity 63 Amps, 50 Hz, 415V with spreader terminals with taking down old unserviceable one complete all as specified and directed. |
| 8 | Supply & fixing in replacement of MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with spreader terminals with taking down old unserviceable one complete all as specified and directed. |
| 9 | Supply & fixing in replacement of MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with spreader terminals including taking down old unserviceable one complete all as specified and directed. |
| 10 | S&F in replacement moulded case circuit breakers(MCCB) 160 Amps, adjustible type, 4 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed. Make- L&T/ ABB/Legrand |
| 11 | S&F in replacement moulded case circuit breakers(MCCB) 200 Amps, adjustible type, 4 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed. Make- L&T/ABB/Legrand |
| 12 | S&F in replacement moulded case circuit breakers(MCCB) 250 Amps, adjustible type, 4 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed. Make- L&T/ABB/Legrand |
| 13 | S&F in replacement moulded case circuit breakers(MCCB) 400 Amps, 4 Pole, 36 KA, thermal magnetic with rotary handle and spreader compete all as specified and as directed. Make- L&T/ABB/Legrand |
| 14 | Supply & fixing in replacement of three pole power contactors of capacity 25 Amp including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. |
| 15 | Supply & fixing in replacement of three pole power contactors of capacity 18 Amp including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. |
| 16 | Supply & fixing in replacement of three pole power contactors of capacity 12 Amp including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. |
| 17 | Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 4.5-7.5 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.Make:L&T/ABB/Legrand |
| 18 | Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 9-15 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.Make:L&T/ABB/Legrand |
| 19 | Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 14-23 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.Make:L&T/ABB/Legrand |
| 20 | Supply & fixing in replacement of Digital type Multifunction meter Flush mounted 3 phase for measuring parameters (V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh), with suitable rating current transformers with built in selector switches suitable for mounting on LT panel, compete all as specified and as directed. Make L&T or equivalent in ABB/Legrand |
| 21 | Supply & fixing in replacement of Digital type Ammeter Flush mounted 3 phase, with suitable rating current transformers suitable for measuring range (0-60) Amps with selector switch suitable for mounting on LT panel, compete all as specified and as directed. Make L&T, ABB/Legrand |
| 22 | Supply and fixing in replacement of cable XLPE Insulated ,screened, PVC bedded, armoured, electric power cables (heavy duty) 1100 Volts grade with aluminium conductor of cross sectional area 185 Sqmm, 3 ½ core with galvanized steel strip or wire including taking down old unserviceable one compete all as specified and as directed. (Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.) |
| 23 | `-ditto- all as per item No. 22 above but cross sectional area 95 Sqmm,3.5 core. |
| 24 | `-ditto- all as per item No. 22 above but cross sectional area 70 Sqmm, 4 core. |
| 25 | `-ditto- all as per item No. 22 above but cross sectional area 50 Sqmm, 4 core. |
| 26 | `-ditto- all as per item No. 22 above but cross sectional area 35 Sqmm,4 core. |
| 27 | `-ditto- all as per item No. 22 above but cross sectional area 25 Sqmm, 4 core. |
| 28 | `-ditto- all as per item No. 22 above but cross sectional area 16 Sqmm, 4 core. |
| 29 | `-ditto- all as per item No. 22 above but cross sectional area 10 Sqmm, 4 core. |
| 30 | Supply & Fixing in replacement of PVC insulated single core copper conductor cable of size 16 sqmm for connections in LT Panels, complete all as specified and as directed. |
| 31 | ditto all as per item no. 23 but size 10 Sqmm |
| 32 | ditto all as per item no. 23 but size 6 Sqmm |
| 33 | Supply & fixing in replacement of cable XLPE Insulated ,screened, PVC bedded, armoured, electric power cables (heavy duty) 1100 Volts grade with aluminium conductor of cross sectional area 630 Sqmm, single core with galvanized steel strip or wire including taking down old unserviceable one compete all as specified and as directed. (Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.) |
| 34 | Material & labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32x6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including testing on completion all as specified and as directed. (Note:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.) |
| 35 | Supply & fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drewn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required 32x6 mm galvanised iron strip including taking down old unserviceable one complete all as specified & as directed. |
| 36 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed. |
| 37 | Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick complete all as specified and as directed. |
| 38 | Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 39 | M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note: For measurement purpose punned thickness of sand shall only be considered. |
| 40 | Supply and Laying burn brick size 230 mm X 113 mm X 75 mm as in protection to cable complete all as specified and directed. |
| 41 | Supply and fixing in replacement cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of following size dia complete all as specified and directed. Make:Zoloto |
| 42 | 150 mm dia. |
| 43 | 125 mm dia. |
| 44 | 100 mm dia. |
| 45 | 80 mm dia. |
| 46 | 65 mm dia |
| 47 | 50 mm dia. |
| 48 | M&L for cutting of existing MS/GI water mains of size 80 mm dia of chiller/condensor/cooling towers & GI pipes of make-up tanks of central AC plant at different points/section for replacement with new MS pipe in short lengths including MS fittings complete all specified and as directed. |
| 49 | All as per item No. 33 here-in-before but of size 100 mm. |
| 50 | All as per item No. 33 here-in-before but of size 125 mm. |
| 51 | All as per item No. 33 above but of size 150 mm. |
| 52 | Taking out old unserviceable MS pipes and Supplying & fixing of mild steel (Heavy) 'C' class pipe of size 80 mm dia on exposed surface / underground (in trenches) including welding works, connections with existing chilled water line, chiller, pump, fabrication of bends, MS flange, tees, reducers, shoe, support (brick masonry block & wooden support for underground / MS angle- clamp & wooden support for exposed surface) along with priming coat of steel primer as per standard specification complete all specified and as directed. Note:- (i) The rates quoted by the contractor shall deemed to include the cost of MS fittings required during laying of MS Pipes. (ii) The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be heavy class of thickness min. 7mm as per IS: 3589. |
| 53 | All as per item No. 34 here-in-before but of size 100 mm. |
| 54 | All as per item No. 34 here-in-before but of size 125 mm. |
| 55 | All as per item No. 34 here-in-before but of size 150 mm. |
| 56 | All as per item No. 34 here-in-before but of size 200 mm. |
| 57 | All as per item No. 34 here-in-before but of size 250 mm. |
| 58 | All as per item No. 34 here-in-before but of size 300 mm. |
| 59 | Supply & Fixing in replacement of Manual Balancing Valve and 3 way modulating control valve suitable for AHU application, PN16 pressure rating, complete with factory-fitted nitrile rubber insulation and cooling thermostat in a single body.The actuator shall be suitable for 2–10 V DC / 4–20 mA control signal and shall provide corresponding flow feedback output for integration with the BMS. The flow feedback provision shall be permanently available on the actuator for manual measurement and BMS connection.The valve shall have a minimum close-off pressure equal to 1.5 times the pump shut-off head, as per specified sizes.The control panel shall operate on 230 V AC supply from the HVAC starter panel. All interconnecting wiring between the control panel and actuator shall be carried out using fire-survival control cables, including supply and installation by the contractor.Complete with all accessories, fittings, wiring, testing and commissioning, as per specifications and as directed by the Engineer-in-Charge. |
| 60 | 65 mm |
| 61 | 50 mm |
| 62 | 40 mm |
| 63 | Supply and fixing in repair/replacement cast iron Y strainer flanged ends with SS perforated sheet screen of size complete all as specified and directed by the Engr-in-Charge. (Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO). |
| 64 | ditto- all as per item No. 36 above but 20 mm dia. |
| 65 | ditto- all as per item No. 36 above but 25 mm dia. |
| 66 | ditto- all as per item No. 36 above but 40 mm dia. |
| 67 | ditto- all as per item No. 36 above but 50 mm dia. |
| 68 | ditto- all as per item No. 36 above but 65 mm dia. |
| 69 | Supply & fixing in replacement of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire for integration within AHU room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required, all as specified and as directed |
| 70 | Fire Damper |
| 71 | Actuator |
| 72 | Supply and fixing in replacement of old unserversible of MS port strainer with complete as specified & directed by Eng-in-charge |
| 73 | 300 mm dia |
| 74 | 250 mm dia |
| 75 | 125 mm dia. |
| 76 | Supplying and laying in replacement synthetic Rubber insulated mats 25 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, compete all as specified and as directed. Make : Jyoti /Dunlop or Equivalent |
| 77 | M&L for cleaning inside surface of Air supply return/exhaust ducts all grills, dampers & diffusers of HVAC system by using high power vacuum air compressor, robotic camera air hammer, special nozzle, air sweep with other required accessories giving/showing inspection of dust before and after cleaning of duct upto the satisfaction of Engr-in-Charge. Note :- (A) The contractor is responsible for any damage/breakage caused at the time of cleaning and the contractor will repair/replace the same without any extra cost to the Govt.(B) The mesurement of cleaning of Duct shall be mesured as per the room area the duct is feeding. |
| 78 | Material and Labour for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed. |
| 79 | Material and labour for maintenance of AHU supply panel / feeder pillar/LT panel indoor/outdoor type including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends fresh and supply and crimping new thimbles/lugs and fixing the cable on bus bar/MCCB/Main switch/MCB including providing new nut bolts and washer if required greasing the doors of feeder pillar/LT panel outdoor/indoor type complete all as specified & directed by Engr-in-Charge. |
| 80 | Supply and fixing in repair/replacement of existing AHU door including nut,bolt,door lock,door glass,door handle,door hinges etc complete all as per specified and directed |
| 81 | Supply and fixing of fire proof double layered canvas cloth connection for indoor outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to Indoor and duct with nuts , bolts complete all as specified and directed. |
| 82 | S&F in repair/replacement cable tray of size 300 x 50 mm and thickness minimum 1.60 mm complete all as specified & directed. |
| 83 | S&F in repair/replacement cable tray of size 150 x 50 mm and thickness minimum 1.60 mm complete all as specified & directed. |
| 84 | Supply & Fixing in replacement of online electrostatic scale-off non-chemical water treatment system with electrically operated control panel. The outer casing shall be of 304 grade stainless steel with Catalytic (copper) metal electrode with both ends flanged and capable preventing scale formation. Electrostatic field change the normal chemistry of water it converts the scale forming ions to neutral molecules with positively charges electrode and stable molecules stay in suspension rather than attaching to wetted surface as scale.The equipment contains following:1: Stainless steel De-scaler unit2: Electronic Control panel.3. Two companion Flange and H.T. Cable Make : ‘Scaleoff (POLO) / Hydrokon / Dolphin |
| 85 | Electrostatic type online non chemical scale preventer unit to be fixed on Sub header line suitable for 3 x 60 TR AC Plant |
| 86 | Electrostatic type online non chemical scale preventer unit to be fixed on Sub header line suitable for 2 x 25 TR AC Plant |
| 87 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 125 mm MS Pipe including painting all as specified and as directed. |
| 88 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 100 mm MS Pipe including painting all as specified and as directed. |
| 89 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 80 mm MS Pipe including painting all as specified and as directed. |
| 90 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 65 mm MS Pipe including painting all as specified and as directed. |
| 91 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 50 mm MS Pipe including painting all as specified and as directed. |
| 92 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 40 mm MS Pipe including painting all as specified and as directed. |
| 93 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 32 mm MS Pipe including painting all as specified and as directed. |
| 94 | Supply & fixing in replacement of GI wire mesh and rendering 15 mm thick Cement Mortar (1:4) over newly provided thermocol insulation on 20 mm MS Pipe including painting all as specified and as directed. |
| 95 | Supply & fixing in replacement of Pre filter 10 micron of size 600mm x 600x 50mm made of out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the all three AC Plant air handling unit complete all as speicifed and directed by Engr-in-charge. (Make- Athlete Enviro Tech, united Fiters or equivalent) |
| 96 | Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. |
| 97 | S&F in repair/replacement of Pressure gauges of the chiller and condenser lines of range 0 - 100Psi. Including syphon and complete fitting |
| 98 | S&F in repair /replacement of temeperature Sensors of the chiller and condenser lines operates by mercury liquid of range 0-50⁰C |
| 99 | Material and labour in replacement of providing and filling post/frame work of stainless steel, grade 304 pipes including braces of stainless steel, plates , angle flats , tubular sections etc including cutting, hoisting fixing with argon welding , bright finish , buffing polishing, grouting with PCC 1:2:4 type B1(using 20mm graded stone aggregates) in the existing foundations complete with necessary holes, nuts , bolts, caps and anchor plates for stainless steel, as specified and directred. |
| 100 | Material and labour for installation of poly carbonate micro prismatic type retro reflective boards conforming to XI of ASTM, made of 4mm thick substrate of aluminium composite panel having 0.50mm thick skin of aluminium both side. The front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type XI of ASTM with coloured scheme, including subject matter , message (bi-lingual), symbol and borders etc as per IRC 67-2001. The aluminium composite panel shall be suitably fixed inside stainless steel frame work with complete fixing angle support , nut bolt etc complete all as specified and directred. |
| 101 | Supply and fixing in repair/replacement display of chiller unit , modal No. KWS-060 14 , Make of Central Type AC Plant kirloskar chiller private limited of capacity 3x60TR TR indicating of Digital setting of temperature levels, Built-in time delay, Auto distribution of load, BMS compatibility, in-built, anti-freeze protection system, Self diagnostics/ fault detection, and Auto-restart feature, along with complete internal wiring with connecting accessories like cable, wires, terminals etc. and re-assembling with the control panel of AC plant testing for staisfactory working complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender