Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58224896

Tender For Repair/ Maintenance Of Voltage Stabilizer And Misc Works At Af Stn Awantipur

Issued by Statutory Bodies & Commissions/Committees · srinagar, Jammu and Kashmir
Tender Value
20 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
20 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repair/ Maintenance Of Voltage Stabilizer And Misc Works At Af Stn Awantipur

BOQ

Name of Work:- REPAIR/ MAINT OF VOLTAGE STABILIZER AND MISC WORKS AT AF STN AWANTIPUR
Sl. No. Item Description
1Taking down defective Voltage Stabilizer of capacity varying from 25 KVA to 100 KVA of any make and model installed at different location of 8FBSU from pole/structure/ sub-station after disconnecting the connections and removing to sub-station then transporting the same to a reputed work shop for repairs. After repairing the same transporting back the repaired transformer (including loading and unloading) to the directed location. After installing the stabilisers connections of LT has to be done as directed by Engr-in-Charge.Note-Items of repair will be measured and paid separately.
2Taking down defective Voltage Stabilizer of capacity varying from 125 KVA to 250 KVA of any make and model installed at different location of 8FBSU from pole/structure/sub-station after disconnecting the connections and removing to sub-station then transporting the same to a reputed work shop for repairs. After repairing the same transporting back the repaired transformer (including loading and unloading) to the directed location. After installing the stabilisers connections of LT has to be done as directed by Engr-in-Charge.Note-Items of repair will be measured and paid separately.
3Taking down defective Voltage Stabilizer of capacity varying from 300 KVA to 500 KVA of any make and model installed at different location of 8FBSU from pole/structure/sub-station after disconnecting the connections and removing to sub-station then transporting the same to a reputed work shop for repairs. After repairing the same transporting back the repaired transformer (including loading and unloading) to the directed location. After installing the stabilisers connections of LT has to be done as directed by Engr-in-Charge.Note-Items of repair will be measured and paid separately.
4Opening/stripping off voltage stabilizer of capacity 25 KVA to 100 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/defective parts requiring replacement, making internal connection servicing of bushings and reassembling the voltage stabilizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. Complete all as directed. Note : Servicing will be done by reputed company rep at site only.
5Opening/ stripping off voltage stabilizer of capacity above 100 KVA to 250 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/defective parts requiring replacement, making internal connection servicing of bushings and reassembling the voltage stabilizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. Complete all as directed. Note : Servicing will be done by reputed company rep at site only.
6Opening/ stripping off voltage stabilizer of capacity above 300 KVA to 500 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/defective parts requiring replacement, making internal connection servicing of bushings and reassembling the voltage stabilizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. Complete all as directed. Note : Servicing will be done by reputed company rep at site only.
7Repairing and rewinding of main transformer of voltage stabiliser using super enamelled copper winding wire of existing gauge including PVC sheet, sleeve, varnishing etc of capacity 25 KVA to 100 KVA including following repairs : (i) Removing top cover of the Voltage Stabilizer and taking out the complete core assembly from the stabilizer including drain out the oil from the stabilizer and clean the conservator. (ii) Cutting and remove the old burnt coil winding from the limbs and rewinding the limbs by new copper wire as suitable size/ as per existing gauge with proper insulation and varnishing complete. (iii) Reassembling the complete core assembly, connection to the existing electric supply line and testing all as per satisfaction of Engineer-in-Charge.
8Repairing and rewinding of main transformer of voltage stabiliser using super enamelled copper winding wire of existing gauge including PVC sheet, sleeve, varnishing etc. of capacity 125 KVA to 250 KVA including following repairs : (i) Removing top cover of the Voltage stabilizer and taking out the complete core assembly from the stabilizer including drain out the oil from the stabilizer and clean the conservator. (ii) Cutting and remove the old burnt coil winding from the limbs and rewinding the limbs by new copper wire as suitable size/ as per existing gauge with proper insulation and varnishing complete. (iii) Reassembling the complete core assembly, connection to the existing electric supply line and testing all as per satisfaction of Engineer-in-Charge.
9Repairing and rewinding of main transformer of Voltage Stabiliser using super enamelled copper winding wire of existing gauge including PVC sheet, sleeve, varnishing etc of capacity 300 KVA to 500 KVA including following repairs : (i) Removing top cover of the Voltage Stabilizer and taking out the complete core assembly from the stabilizer including drain out the oil from the stabilizer and clean the conservator. (ii) Cutting and remove the old burnt coil winding from the limbs and rewinding the limbs by new copper wire as suitable size/ as per existing gauge with proper insulation and varnishing complete. (iii) Reassembling the complete core assembly, connection to the existing electric supply line and testing all as per satisfaction of Engineer-in-Charge.
10M&L draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity above 200 KVA to 500 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
11M&L draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 25 KVA to 200 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
12M&L for repairing the voltage stabilizer of any make, capacity above 200 KVA to 500 KVA by supply and fixing in replacement of following items:-(a) Electronic printed circuit board of solid state including ICs, regulators, condensers, triac, transistors complete.
13(b) Circuit control/trigger transformer.
14(c ) Main terminal block.
15(d) Choke coils.
16(e) Carbon brush.
17(f) Spacer for Dimmer coils.
18(g) Input switch to stop over running of dimmer start motor.
19(h) Servo motor with 20 Kg-cm torque.
20(j) Driving gear.
21(k) Bearing for dimmer coils.
22(l) Terminal connections brass rod with bush and brass stud.
23(m) Servo Card analog
24(n) Wiring set
25(o) Electromagnetic Relay 6 Ampere
26(p) Electromagnetic Relay 20 Ampere
27(q) Carbon holder
28(r) Carbon arm with finger
29(s) Limit switch
30(t) RC Network
31M&L repairing the voltage stabilizer of any make, capacity above 100 KVA to 200 KVA by supply and fixing in replacement of following items:-(a) Electronic printed circuit board of solid state including ICs, regulators, condensers, triac, transistors complete.
32(b) Circuit control/trigger transformer.
33(c ) Main terminal block.
34(d) Choke coils.
35(e) Carbon brush.
36(f) Spacer for Dimmer coils.
37(g) Input switch to stop over running of dimmer start motor.
38(h) Servo motor with 20 Kg.cm torque.
39(j) Driving gear.
40(k) Bearing for dimmer coils.
41(l) Terminal connections brass rod with bush and brass stud.
42(m) Servo Card analog
43(n) Wiring set
44(o) Electromagnetic Relay 6 Ampere
45(p) Electromagnetic Relay 20 Ampere
46(q) Carbon holder
47(r) Carbon arm with finger
48(s) Limit switch
49(t) RC Network
50M&L repairing the voltage stabilizer of any make, capacity from 25 KVA to 100 KVA by supply and fixing in replacement of following items:-(a) Electronic printed circuit board of solid state including ICs, regulators, condensers, triac, transistors complete.
51(b) Circuit control/ trigger transformer.
52(c ) Main terminal block.
53(d) Choke coils.
54(e) Carbon brush.
55(f) Spacer for Dimmer coils.
56(g) Input switch to stop over running of dimmer start motor.
57(h) Servo motor with 20 Kg.cm torque.
58(j) Driving gear.
59(k) Bearing for dimmer coils.
60(l) Terminal connections brass rod with bush and brass stud.
61(m) Servo Card analog
62(n) Wiring set
63(o) Electromagnetic Relay 6 Ampere
64(p) Electromagnetic Relay 20 Ampere
65(q) Carbon holder
66(r) Carbon arm with finger
67(s) Limit switch
68(t) RC Network
69S&F for replacement of current transformer of min ratio 100/5 Amps (Set of three) all as specified and directed.
70S&F for replacement of current transformer of ratio 200/5 Amps (Set of three) all as specified and directed.
71Supply and replacement of digital ampere meter of suitable range as per existing size all as specified and directed.
72Supply and fixing in repairs of digital voltmeter of size 72 x 72 mm of suitable range as per existing size all as per specified and directed.
73Supply and fixing in repairs of indicator with bulb, red, yellow or green 230 volts as per sample complete all as specified and directed.
74Supply and fixing in repairs of push button any type and size as per sample, suitable to operate the synchronous motor manually, complete all as specified and directed.
75Supply & toping up of new transformer oil (in sealed barrel) having dielectric strength 50KV at 2.5mm gap after initial dehydration complete all as specified and directed.
76M&L for dehydration of transformer oil upto dielectric strength not less than 50KV at 2.5 mm gap all as specified and as directed by Engr-in-Charge.
77Supply and fixing MCCB in replacement of 100 Amps, 4 pole, 415 Volts, 50 HZ, rupturing capacity 16KA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed.
78Supply and fixing MCCB in replacement of 200 Amps, 4 pole, 415 Volts, 50 HZ adjustable type with rupturing capacity 36KA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed.
79S&F dimmer for Voltage Stabiliser of capacity 25KVA and upto 50 KVA all as specified and directed.
80S&F dimmer for Voltage Stabiliser of capacity above 50 KVA and upto 100 KVA all as specified and directed.
81S&F dimmer for Voltage Stabiliser of capacity above 100 KVA and upto 250 KVA all as specified and directed.
82S&F dimmer for Voltage Stabiliser of capacity above 250 KVA and upto 500 KVA all as specified and directed.
83Note:- An amount of Rs.38,790.00 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58224896
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair/ Maintenance Of Voltage Stabilizer And Misc Works At Af Stn Awantipur
Basic Detail
Tender No GE (AF) AWA-49/2026-27
Bidding Type Tender
Location
City srinagar
State Jammu and Kashmir
Key Dates
Publish Date 27 Oct 2026
Submission Date 17 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
98442c15-67e4-4f76-a1bd-ea871757507d.html
BOQ_892688.xls
Tender49.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

98442c15-67e4-4f76-a1bd-ea871757507d.html

xls

BOQ_892688.xls

pdf

Tender49.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender