Tender For Beautification Of Chowk Outside Kutiya Baba Baraham Dass In Ward No 5 At Mc Kalanaur (Est. Cost Rs. 15.00 Lakh)
Tender Value
12.71 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
6 days left
EMD
30000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rohtak → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Beautification Of Chowk Outside Kutiya Baba Baraham Dass In Ward No 5 At Mc Kalanaur (Est. Cost Rs. 15.00 Lakh)
BOQ
| Sl. No. | Item Description |
| 1 | NS Item -installation Of Fountain 20` dia |
| 2 | NS Item -Providing and fixing of stainless steel bollards of 10gauge 304Q with 100mm dia x3mm thick, Patti 20mm x 4mmthick (3Nos) With Radium Patti, Bass Plate200mmx200mmx4mm thick all labour and material required tofor including the cost of all labour and material required tocomplete the job in all respect up to the entire satisfaction ofthe Engineer in charge of the work |
| 3 | NS Item -PandF of Submersible Complete in all respect. |
| 4 | NS Item -Supply of single band poles are made of durable Mild Steel with a total height of 4 meter above ground level. The Single Band pole shall be of section 100x100 mm of 4 mtr long. The band pole with decorative single side bracket of760x100x100mm long with street light of 50W each. Pole shall be with base plate of size 300x300x12mm. All pole section shall be welded by certified welders using high and MIG welding process. The Service door shall be provided at bottom part of the pole which equipped with a C clamp withsliding nuts to accommodate a built in connection box. The control gear tray is prewired with MCB, terminal connectors for loop in loop out arrangement. The base plated of the pole shall be designed with elongated foundation holes for fine alignment of the pole during installation. The optical system has been carefully engineered to provide correct illumination and enhanced security. the optical system has been carefully engineered to provide correct illumination and enhanced security. Light output of source is more than 110lm/ watt, CRI)70, Surge protection 4k, operating voltage 140-270V. The single side side decorative street light pole will be as per attached detail drawing. Fitting is IP66, wired with Branded OSRAM or equivalent make LED and Fulham or equivalentconstant current driver. Proper thermal management for longer life of fixture. Led burning of 50,000 hours. Pole primarily coated with primer than epoxy resin and top coated with UV stabilised MRF PU powder coat and cured. Band poleis completely weather protected land suitable for outdoorlighting application and suitable for the street lighting. Pole iscomplete in all aspect with all accessories without foundationbolts. |
| 5 | HSR Item 28.20.1-Providing and applying integral crystallineslurry of hydrophilic in nature for waterproofing treatment tothe RCC structures like retaining walls of the basement, watertanks, roof slabs, podiums, reservoir, sewage and watertreatment plant, tunnels / subway and bridge deck etc.,prepared by mixing in the ratio of 5 : 2 (5 parts integralcrystalline slurry : 2 parts water) for vertical surfaces and 3 : 1(3 parts integral crystalline slurry : 1 part water) for horizontalsurfaces and applying the same from negative (internal) sidewith the help of synthetic fibre brush. The material shall meetthe requirements as specified in ACI-212-3R-2010 i.e. byreducing permeability of concrete by more than 90%compared with control concrete as per DIN 1048 and resistantto 16 bar hydrostatic pressure on negative side. Thecrystalline slurry shall be capable of self-healing of cracks upto a width of 0.50mm. The work shall be carried out allcomplete as per specification and the direction of theengineer-in-charge. The product performance shall carryguarantee for 10 years against any leakage. 1. For verticalsurface two coats @ 0.70 kg per sqmHSR Rate(Rs.) 398.00 Through Rate |
| 6 | HSR Item 10.51-Providing and fixing granite stone in allshades 15mm to 18 mm thick in skirting /dado, risers ofsteps, pillars and wall facing, laid in any pattern as specifiedover base of 12mm thick cement coarse sand mortar 1:3 andjointed with white cement slurry mixed with pigment to matchthe shade of Granite including labour for fixing cramps pinsand dowels etc.HSR Rate(Rs.) 2534.00 Through Rate |
| 7 | HSR Item 10.96-Providing and fixing Glass mosaic tiles onfinished plain wall surface of size 20 mm x 20 mm x 4 mm inall colour, design , fixing in customize design as per directionof Engineer-in- Charge. The glass mosaic tiles to be fixed onthe wall surface with the help of approved adhesive applied atthe rate of 2.5 kg per sqm and grouting of the same. The rateis inclusive of all operation, material and required patternapproved by Engineer-in-Charge:HSR Rate(Rs.) 2650.00 Through Rate |
| 8 | HSR Item 6.1.6-Providing and laying in position cementconcrete of specified grade excluding the cost of centeringand shuttering - All work below plinth level and up to Floor IVlevel: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 gradedstone aggregate 40 mm nominal size)HSR Rate(Rs.) 2442.00 Through Rate |
| 9 | HSR Item 4.12.1-Earth work in excavation by mechanicalmeans (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqmon plan) including getting out and disposal of excavated earthlead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soilHSR Rate(Rs.) 78.00 Through Rate |
| 10 | HSR Item 6.15.1-Reinforced cement concrete work in walls(any thickness), including attached pilasters, buttresses, plinthand string courses, fillets, columns, pillars, piers, abutments,posts and struts etc. above plinth level up to floor four level,excluding cost of centering, shuttering, finishing andreinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zoneIII) : 3 graded stone aggregate 20 mm nominal size)HSR Rate(Rs.) 5969.00 Through Rate |
| 11 | HSR Item 5.23.1-Demolishing cement concrete manually/ bymechanical means including disposal of material within 50metres lead as per direction of Engineer - in - charge. 1.Nominal concrete 1:1.5:3 or richer mix (i/c equivalent designmix)HSR Rate(Rs.) 480.00 Through Rate |
| 12 | HSR Item 6.30.2-Centering and shuttering including strutting,propping etc. and removal of form for 2. Walls (any thickness)including attached pilasters, buttresses, plinth and stringcourses etc.HSR Rate(Rs.) 282.00 Through Rate |
| 13 | HSR Item 6.14.1-Providing and laying in position specifiedgrade of reinforced cement concrete, excluding the cost ofcentering, shuttering, finishing and reinforcement - All work upto plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zoneIII): 3 graded stone aggregate 20 mm nominal size)HSR Rate(Rs.) 4374.00 Through Rate |
| 14 | HSR Item 6.33.6-Steel reinforcement for R.C.C. work, wherenot included in the complete rate of RCC, includingstraightening, cutting, bending, placing in position, binding,wastage, overlaps, welded joints, spacer bars, chairs, stays,hangers and annealed steel wire etc. complete in all respectbelow plinth level Note: Reinforcement shall be measured inlength including hooks, if any, separately for differentdiameters as actually used in work , excluding overlaps.Wastage, overlaps, couplings, welded joints, spacer bars,chairs, stays, hangers and annealed steel wire or othermethods of binding & placing shall not be measured and costof these items shall be deemed to be included in the rates forreinforcement. 6. Thermo-Mechanically Treated bars of gradeFe-500D or moreHSR Rate(Rs.) 66.00 Through Rate |
| 15 | HSR Item 5.70-Disposal of building rubbish / malba / similarunserviceable, dismantled or waste materials by mechanicalmeans, including loading, transporting, unloading to approvedmunicipal dumping ground or as approved by Engineer-incharge, beyond 50 m initial lead, for all leads including all liftsinvolved.HSR Rate(Rs.) 86.00 Through Rate |
| 16 | HSR Item 23.1.6.4-COPPER WIRING IN MS CONDUIT(SURFACE/RECESS) 6.4. Wiring main ,sub mains and Circuitwiring in two single core for phase and neutral wire and onesingle core for earth wire PVC insulated Copper conductorcable 1100 Volts grade in MS Conduit etc as required. 1 runof Size 6 Sqmm(1/2.80mm)HSR Rate(Rs.) 238.00 Through Rate |
| 17 | HSR Item 23.1.6.5-COPPER WIRING IN MS CONDUIT(SURFACE/RECESS) 6.5. Wiring main ,sub mains and Circuitwiring in two single core for phase and neutral wire and onesingle core for earth wire PVC insulated Copper conductorcable 1100 Volts grade in MS Conduit etc as required. 1 runof Size 10 Sqmm(1/3.50 mm)HSR Rate(Rs.) 411.00 Through Rate |
| 18 | HSR Item 24.8.2-RCC FOUNDATIONS FOR OCTAGONALPOLES 2. Providing RCC foundation of M25 grade (1Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation,steel reinforcement (Fe 500) @80 kg/cum of concretecontents, concrete cover 50mm, anchor bolts etc. over a bedof PCC 1:5:10 of required dimensions for octagonal poles ofvarious heights as per following specifications complete in allrespects and as per directions of Engineer-in-charge4m high poleHSR Rate(Rs.) 2849.00 Through Rate |
| 19 | HSR Item 13.41-Providing and fixing stainless steel ( Grade304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixingthe railing with necessary accessories and stainless steeldash fasteners , stainless steel bolts etc., of required size, onthe top of the floor or the side of waist slab with suitablearrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shallbe considered excluding fixing accessories such as nuts,bolts, fasteners etc.).HSR Rate(Rs.) 396.00 Through Rate |
| 20 | HSR Item 6.29.1-Centering and shuttering including strutting,propping etc. and removal of form work for : 1. Foundations,footings, bases for columnsHSR Rate(Rs.) 155.00 Through Rate Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender