Road Transport and Highways Boards / Undertakings / PSU Closing in 4 days TDR #58224323

Tender For Works Contract For Civil & Structural Works Including Supply Of All Materials In Connection With Mechanical Works For Lube Modernization & Bottom Upgradation (Lmbu) Project Of Hpcl, Mumbai Refinery, India

Issued by Boards / Undertakings / PSU · Mumbai Suburban, Maharashtra
Tender Value
7.09 Crore
Estimated cost
Bid Submission
23 Nov 2026
4 days left
EMD
16.12 Lakhs
Bank guarantee accepted
Document Fee
19470
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Works Contract For Civil & Structural Works Including Supply Of All Materials In Connection With Mechanical Works For Lube Modernization & Bottom Upgradation (Lmbu) Project Of Hpcl, Mumbai Refinery, India

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Nov-2026 CORRIGENDUM-1 Date 23-Nov-2026

BOQ

Name of Work:- WORKS CONTRACT FOR CIVIL & STRUCTURAL WORKS INCLUDING SUPPLY OF ALL MATERIALS IN CONNECTION WITH MECHANICAL WORKS FOR LUBE MODERNIZATION & BOTTOM UPGRADATION (LMBU) PROJECT OF HPCL, MUMBAI REFINERY, INDIA
Sl. No. Item Description
1Part A: Civil & Structural works in Offsites including ISBL works
2STRUCTURAL
3EARTH WORK (REFER SPECIFICATION NO. 6-68-0003)
4Earthwork excavation in soil
5Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
6Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
7Earthwork excavation in soft rock
8Earth work in EXCAVATION below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
9Earth work in EXCAVATION below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth beyond 1.5m and upto & inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
10SHORING AND STRUTTING
11Providing and installing approved type of \\"SHORING AND STRUTTING\\" by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed.
12Providing and installing approved type of \\"SHORING AND STRUTTING\\" by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed.
13Backfilling after execution of work
14BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.
15BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.
16BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 500M AND UPTO & INCLUSIVE OF 1KM including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.
17Transporting & Disposing the SURPLUS EARTH AND DEBRIS
18Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids).
19Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids).
20\\"Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction areas to areas ANYWHERE OUTSIDE THE PLANT BOUNDARY, including re-excavating the deposited soil excavated earlier, loading, transportation, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). DISPOSAL AREAS OUTSIDE PLANT BOUNDARY TO BE ARRANGED BY THE CONTRACTOR. Royalty as applicable for disposal outside plant limits to be borne by the Contractor.\\"
21Transportation of ROCK material
22Transportation of ROCK material coming out of operation of item Nos. 01CS.1.2 to 01CS.1.5 BEYOND INITIAL LEAD OF 100M AND UPTO 1KM to the area of disposal including loading, unloading, laying at all depths and heights, stacking, spreading, levelling at an area of disposal as directed. For carting on the basis of Truck Measurements (volume of truck reduced by 50% for voids).
23Transportation of ROCK material coming out of operation of item Nos. 01CS.1.2 to 01CS.1.5 beyond initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM to the area of disposal including loading, unloading, laying at all depths and heights, stacking, spreading, levelling at an area of disposal as directed. For carting on the basis of Truck Measurements (volume of truck reduced by 50% for voids).
24Transportation of ROCK material coming out of operation of item Nos. 01CS.1.2 to 01CS.1.5 UPTO the area of disposal ANYWHERE OUTSIDE THE PLANT BOUNDARY including loading, unloading, laying at all depths and heights, stacking, spreading, levelling at an area of disposal as directed. For carting on the basis of Truck Measurements (volume of truck reduced by 50% for voids). DISPOSAL AREAS OUTSIDE PLANT BOUNDARY TO BE ARRANGED BY THE CONTRACTOR. Royalty as applicable for disposal outside plant limits to be borne by the Contractor.
25Earthwork Manual Excavation in SOIL
26Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
27Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
28Earthwork Manual Excavation in SOFT ROCK
29Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
30Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth beyond 1.5m and upto & inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
31PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004)
32PCC - Non FIM Items
33Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
34Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
35RCC Substrutures - Non FIM Items
36Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
37Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
38RCC Superstructures - Non FIM Items
39Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
40Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS MORE THAN 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
41Precast Elements - Non FIM Items
42Manufacturing, transporting, supplying and erecting in position Reinforced Cement Concrete PRECAST ELEMENTS such as columns, beams, cover slabs, lintels, louvers, fins, shelves etc. of M-35 grade with 20mm and down size graded crushed stone aggregates/gravel, each unit upto and inclusive of 500 kg. for all leads, levels, shapes and thickness including all moulds, shuttering and centering, vibrating, tamping, curing, chamfering wherever required, finishing the top surface with cement mortar 1:3 (1 Cement : 3 Sand) to give a smooth and even surface, or non skid finish as specified, providing lifting hooks, metal inserts, making holes pockets, (only M.S. inserts to be measured & paid separately) transporting to site, erecting, levelling, aligning and fixing in position with cement mortar 1:3 ( Cement : 3 Coarse Sand), breaking bricks and/or concrete surfaces and making good the same etc. all complete (excluding the Cost of Reinforcement ) and as directed. All materials including cement supplied by the contractor.
43Manufacturing, transporting, supplying and erecting in position Reinforced Cement Concrete PRECAST ELEMENTS such as columns, beams, cover slabs, lintels, louvers, fins, shelves etc. of M-35 grade with 20mm and down size graded crushed stone aggregates/gravel, each unit beyond 500 kg and upto and inclusive of 1000 kg. for all leads, levels, shapes and thickness including all moulds, shuttering and centering, vibrating, tamping, curing, chamfering wherever required, finishing the top surface with cement mortar 1:3 ( 1 Cement : 3 Sand) to give a smooth and even surface, or non skid finish as specified, providing lifting hooks, metal inserts, making holes pockets, (only M.S. inserts to be measured & paid separately) transporting to site, erecting, levelling, aligning and fixing in position with cement mortar 1:3 ( Cement : 3 Coarse Sand), breaking bricks and/or concrete surfaces and making good the same etc.all complete (excluding the Cost of Reinforcement) and as directed. All materials including cement supplied by the contractor.
44HYD Bars / MS Bars - Non FIM Items
45Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
46Conc. Encasing - Non FIM Items
47Providing and laying Reinforced Cement Concrete of grade M-35 with 20mm and down size graded stone aggregates for ENCASING OF STRUCTURAL STEEL WORK including chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (excluding the cost of Reinforcement and Shuttering) for all heights and depths in any shape, position, and thickness etc. all complete as specified and shown. Cement. All materials supplied by the contractor.
48Centering and Shuttering - Non FIM Items
49Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed.
50Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed.
51Expansion joints - Non FIM Items
52Providing 20mm wide EXPANSION JOINTS in flooring and pavement slabs and ISOLATION JOINTS around equipment foundations/columns/pedestal/trenches etc. including cleaning the joints of all loose material, filling clean sand for the full depth of slab (upto and inclusive of 300 mm) except for 12mm depth from top and sealing the top 12mm with approved two part liquid polysulphide Sealing Compound as per IS:12118 etc. all complete as shown, specified and directed.
53STRUCTURAL STEEL WORKS SPEC NO. 6-68-0006
54General Steel Works - Non FIM Items
55Supplying, Fabricating at CONTRACTOR's shop outside the plant boundary, transporting fabricated items to site, unloading, storing, erecting in position and testing/ examining , bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250A / E250BR / E250B0 (conforming to IS:2062 at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc.. all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
56Supplying, Fabricating at CONTRACTOR's shop outside the plant boundary, transporting fabricated items to site, unloading, storing, erecting in position and testing/ examining , bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250A / E250BR / E250B0 (conforming to IS:2062 at all locations and levels MORE THAN 20 m ABOVE HPP/ FGL including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc.. all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
57Painting - Non FIM Items
58Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 10.2 of Table 10.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 7.2.1 of Table 7.2 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable), for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COSTAL) areas considering environmental classification as INDUSTRIAL MARINE. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on Structural steel weight).
59Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 8.1 of Table 8.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) for painting over the coat of shop primer & galvanisation already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on weight of steel).
60Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. no. 10.2 of Table 10.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of self priming type surface tolerant high build epoxy coating F-8, 100micron DFT, over the damaged area requiring repair/rectification, including storage, surface preparation as per ST.2, degreasing, cleaning, drying, providing necessary arrengement for access, testing etc., for steel structures (excluding ladders, spiral stairways & handrails) at all location & levels, all complete as specified, in OFFSITE (COASTAL) areas as well as UNIT (COASTAL & INLAND) areas considering environmental classification as INDUSTRIAL MARINE. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on surface area in Sqm)
61Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. no. 8.1 of Table 8.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of self priming type surface tolerant high build epoxy coating F-8, 100micron DFT, over the damaged area requiring repair/rectification, including storage, surface preparation as per ST.2, degreasing, cleaning, drying, providing necessary arrengement for access, testing etc. for HANDRAIL, LADDERS & SPIRAL STAIRWAYS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on surface area in Sqm)
62Barricading Structure - Non FIM Item
63Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS FOR BARRICADING, of Grade E250A / E250BR / E250B0 (conforming to IS:2062) and/ or CFSHS/ CFRHS of Grade YSt 310 (conforming to IS:4923) and/ or CFCHS of Grade YSt 310 (conforming to IS:1161) at all locations and levels, including all built-up sections/ compound/ hollow/ tubular sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks for isolating the construction area, cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Non-shrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting and applying pre-erection/ shop primer as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc., AND maintaining the structure during project execution AND dismantling, removing & taking away all materials outside the plant boundary after completion of the project, to the complete satisfaction of Engineer-in- charge all complete as per the direction of Engineer-in-Charge. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
64STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007)
65Yst310 IS 4923
66Supplying, Fabricating at contractor's workshop outside plant boundary, mock assembly, protective packing after applying primer, transporting fabricated items to site, and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS, USING COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS:4923, Grade Yst 310 ( Raw material used for these steel shall be hot rolled coil of min Yst=310 MPa) of approved make, including all built-up sections/ compound sections made out of rolled sections and/or plates/ bent plates, in all types of structural frameworks, truss, floor beams, stairs, sag rods, ladders or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, welding/bolting of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, including preparation and submission of detailed fabrication drawings, planning location of splices in structural assembly to suit transportation ease and minimum number of joints at site, preparing the surface for painting (SSPC-SP-10), applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) after fabrication etc. all complete. Identification of the prefabricated items supplied to site as per design drawings at construction site to facilitate storage/erection by others. SUPPLY OF ALL MATERIAL INCLUDING GALVANIZED NUTS, WASHER AND BOLTS FOR FIELD BOLTED JOINTS IS IN CONTRACTOR'S SCOPE. (ALL FIELD CONNECTION SHALL BE BOLTED CONNECTION UNLESS OTHERWISE MENTION IN AFC/ APPROVED FABRICATION DRAWING).
67MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008
68Anchor Bolts - FIM Items
69Fixing and keeping in position at all levels and locations already fabricated THREADED ANCHOR BOLTS of all diameters and nomenclature supplied by the owner as Free Issue including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including transporting the same from owner's store/issue points to site of work handling , straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed. (BOLTS SHALL BE SUPPLIED BY THE OWNER AS FREE ISSUE).
70Anchor Bolts - Non FIM Items
71Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
72MS Metal Inserts - Non FIM Items
73Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
74GI Pipe Sleeves - Non FIM Items
75Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed.
76MS Chequered Plates - Non FIM Items
77Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
78MS Grating Cat. A,B - Non FIM Items
79Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturer's supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE.
80Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings.
81Hand Railing 1000mm - Non FIM Items
82Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
83Supplying, fabricating and fixing in position (to already erected vertical posts for Hand Railing) at all locations ONLY TOP RAIL 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, welding, bending, surface preparation, shop primer as per EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
84Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
85Hand Railing 500mm - Non FIM Items
86Supplying, fabricating and fixing in position at all locations 500mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS:4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
87Mechanical Anchor fastners - Non FIM Items
88\\"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
89\\"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
90Chemical Anchor Fastner
91\\"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
92\\"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 24mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
93Threaded bolts for equipment fixing-Non FIM
94Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
95DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012)
96RCC - Non FIM Items
97Making cut-outs in RCC slab/ wall upto a thickness of 400mm (taking all necessary safety precautions) by vibration-less spark-free mechanical means like core- cutting, wet cutting by diamond wall saw system at all depths & heights including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, disposal of unserviceable material, plastering & finishing the cut surfaces, all complete as specified and directed by the Engineer-in- Charge (Measurement on Plan/ Elevation Area basis).
98Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).
99Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).
100Pockets - Non FIM Items
101Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed.
102PCC _ Non FIM Items
103Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).
104Steelwork - Non FIM Items
105Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed.
106AC / GI Sheets - Non FIM Items
107Dismantling GI/asbestos/translucent sheets, ridges, gutters etc. (taking all necessary safety precautions) in roofings and wall claddings, including supply of all tools & tackles, necessary scaffolding, consumables, cutting (by flame or saw) of fixing hooks, transporting and stacking the serviceable materials, cleaning the site and disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete for all levels, as specified and directed.
108MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013)
109Sand Filling - Non FIM Items
110Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete .
111BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE
112Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturer's specification for protection of reinforcement against corrosion. Supply of admixture in Contractor's scope.
113BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056)
114Epoxy Resin - non FIM Items
115Providing and applying approved EPOXY RESIN (prepared as per manufacturer's recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items).
116SAFETY (REFER EIL SPECIFICATION)
117Safety Structures - Non FIM Items
118Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers.
119Providing of steel scaffold stair tower system with minimum 800 mm wide flights, landings at every 1.5 to 2.0 m height, handrailing around flights and landings for safe access upto a height of 12.0 m, all complete including supply of all materials, tools & tackles, manpower etc., at the location directed by Engineer-in-Charge on monthly rental basis. Rental charges shall be payable after completion of erection of the system and acceptance by the Engineer-in- Charge. Rates shall also be inclusive of dismantling of the system and taking out all materials from the project permises as directed by the Engineer-in-Charge. Rate quoted shall be for Running Meter (Height) per month.
120GENERAL CIVIL
121ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER)
122Earthwork in filling with borrow earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved borrow areas for all leads from Complex Limit including excavation of earth at borrow areas, clearing and stripping at borrow areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as per IS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of all unserviceable materials if any beyond the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. (Borrow areas shall be arranged by Contractor at his own cost. The rate quoted shall include all royalties, right-of-way etc. complete)
123CONCRETE PAVEMENTS
124Providing and laying Reinforced Cement Concrete with 20mm and down size graded crushed stone aggregates in flooring, pavements etc. including leaving pockets, if necessary, making recess/drains, laying in alternate panels, etc. for all depths including shuttering, tamping, curing, etc. as specified in any shape, thickness, position and finishing the top surface smooth etc. all complete as per drawings, specifications and directions of Engineer-in- Charge.
125For RCC of M-30 grade concrete (all materials including cement but excluding cost of providing & fixing reinforcement and joint sealing shall be supplied by the contractor).
126Supplying and laying of 150 micron thick HM HDPE (Grade- I) FILM lining conforming to IS 10889 below concrete pavements, Hard stand, at any other place etc. including royalties, taxes, handling, transportation, unloading, storage, joining etc. all complete as per drawings, manufacturer's specifications and directions of Engineer-in- charge.
127Supply of all materials and Construction of DRY LEAN CEMENT CONCRETE SUB-BASE (7 days compressive strength of 10.0 MPa) with 26.5mm and down size aggregate including cement , water, and approved additives on a prepared sub-grade, mixed in batching plant, transported to site, for all leads & lifts, laid, compacted, finished and cured etc. complete as per IRC:SP:49 (Guidelines for the use of Dry Lean Concrete as Sub-Base), drawings, standards, specifications and directions of Engineer-in-charge.
128Providing 20mm wide Expansion Joints in pavement slabs as per standard/ drawing including cleaning the joints of all loose material, filling with 20mm thick impregnated fibre boards for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. all complete as per drawings, specifications and directions of Engineer-in-Charge.
129For type-I pavement (Upto and inclusive of thickness of 200 mm).(Including providing and laying MS dowel bar, painting as required, GI pipe and cap and cotton waste).
130For type-II pavement (Upto and inclusive of thickness of 150 mm)
131For type-III pavement (Upto and inclusive of thickness of 100 mm).
132For thickened pavement (Upto and inclusive of thickness of 300 mm).
133Providing joints in pavements and around foundations as per standard/ drawing including cleaning the joints of all loose materials and sealing with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in- Charge for.
134Construction joints 20mm wide x 25mm deep.
135Sealing joint around pedestal and column etc. 20mm wide x 200 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge.
136Sealing joint around pedestal and column etc. 20mm wide x 150 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge.
137Sealing joint around pedestal and column etc. 20mm wide x 100 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge for.
138Sealing joint around pedestal and column etc. 20mm wide x 300 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge for.
139Sealing joint around precast cover etc. 10mm wide and for full depth of slab (upto and inclusive of 300 mm) including filling with clean sand for the full depth of slab except for 10mm depth from top and sealing the top 10mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge for.
140Supply of forged/ cast fittings
141Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owner's stores/workspot etc. all complete as per the directions of Engineer-in- Charge.
142Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class
143Dia. 1.5 Inch Pipe Class J2A
144MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS
145Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specified shall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge. For following Brick Class.
146All materials including cement supplied by the Contractor and Following Brick Class
147Brick Class 5
148Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge.
149All materials including cement supplied by the Contractor.
150PLUMBING AND BUILDING DRAINAGE
151Cement Lined Pipe (Above ground)
152Laying and joining of Carbon Steel pipes and specials above ground at all elevations for buildings, including preparing requisite spools, transportation of all material from Owner's storage point to worksite, including providing internal cement lining on pipes and specials as per specification for cement lining, including cutting floors/walls and making good the same, fabrication including cutting of pipes, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, threading, and laying of pipes of all type and thickness, welding the same, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges, orifice assemblies and all other online instruments, and fittings and specials, like elbows, reducers, tees, vents, blind flanges, drains, stub in/ branch connections, alignment, fixing of nuts, bolts, gaskets and washers, including providing pipe joints as per specifications including supply & erection of collars for pipe joints, hydrostatic testing, pneumatic, vacuum, spark testing and any other type of testing as specified, draining, drying by compressed air etc. completing all such works in all aspects, cleaning and flushing, etc. complete as per drawings, specifications and instructions of Engineer-in- Charge including return of all unused /scrap pipe to owner's storage point (Bare Pipes and fittings shall be supplied by owner as free issue material. Collar sleeves for pipe jointing shall be supplied by contractor. Cement lining of pipes, fittings and specials including supply of all materials shall be in contractor's scope.) For Water System
153Dia. 6 Inch PMS A33Y
154Dia. 4 Inch PMS A33Y
155Dia. 1.5 Inch PMS A33Y
156Dia. 1 Inch PMS A33Y
157MISCELLANEOUS ITEMS
158Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge.
159Lining/Pitching
160Providing and laying 100 mm thick cement concrete lining of M-20 grade with 20mm and down size graded stone aggregates for embankments, road side slopes holding ponds bunds, drains, tank pad, channels or at any other place as directed, including laying cement concrete in alternate panels, shuttering the edges, curing, finishing the top surface rough or smooth complete as per drawings, specifications and directions of Engineer-in-Charge.
161On horizontal surfaces (All materials including cement supplied by contractor)
162On sloped surfaces (All materials including cement supplied by contractor)
163Supply and installation of expansion bellow as per specification comprising of rubber expansion bellow in position including transportation of the material to work site, as per directions of Engineer-in-Charge. For following nominal size and piping class
164Dia 30 Inch Piping Material Class A5Y
165NDT Testing
166DYE PENETRATION / MAGNETIC PARTICLE TEST Performing of magnetic particle test or dye penetration test including supply of all necessary materials, equipment and labour for carrying out the work as per specs. and direction of Engineer-in -charge
167DP TEST LENGTH(BW&SW)
168MAGNETIC PARTICLE TEST
169RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specifications and instructions of Engineer-in- Charge. Radiographs shall be submitted to the Engineer-in- charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractor's fault and foradditional radiography necessitated due to poor performance of contractor's welders shall be done at contractor's cost) Note: Unit for radiography quantity is 'Nos of circumferential weld joints'.
170FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING)
171Nominal Dia. 4 Inch
172Nominal Dia. 6 Inch
173Nominal Dia. 2 Inch
174Nominal Dia. 1 Inch
175Nominal Dia. 16 Inch
176Nominal Dia. 18 Inch
177Nominal Dia. 1.5 Inch
178FOR JOINTS THK. > 8 (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING)
179Nominal Dia. 8 Inch
180Nominal Dia. 12 Inch
181Nominal Dia. 10 Inch
182Nominal Dia. 14 Inch
183Portable/ trolley mounted Extinguishers
184Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge.
185Capacity in Kg 9
186Capacity in Kg 6
187Supply and installing in position, trolley mounted DCP (Dry Chemical Powder Type) extinguisher including transporting to worksite, placing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge.
188Capacity in Kg 50
189Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge.
190Capacity in Kg 4.5
191Tank Fire Protection
192Supplying and Installation of aluminum alloy foam couplings with inbuilt NRV having one number 63.5mm (2-1/2\\") male instantaneous type inlet coupling conforming to IS:903 with flanged outlet connection including supply of nuts, bolts, gaskets, washers as per drawings, specifications and direction of Engineer-in-Charge. For the following flanged outlet dia. in inch
193Outlet Dia. (Nominal) 3 Inch
194Fabrication and Erection of piping (underground)
195FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owner's storage point to worksite, earthwork in excavation in all types of soil EXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re- excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owner's storage point (Pipes and fittings shall be supplied by owner as free issue material.) (Depth of excavation for pipe trench shall be upto 3.0m)
196Carbon Steel Piping (Non IBR), Thickness <=10 mm
197Fabrication, For the following nominal sizes
198NB 2 inch - 6 inch
199NB 8 inch - 14 inch
200Erection including corrosion protection coating, for Water System (Pressure Piping), For following Nominal Sizes
201NB 2 inch - 6 inch
202NB 8 inch - 14 inch
203Cement Lined Pipe
204Laying and joining of Carbon Steel pipes and specials underground including preparing requisite spools, transportation of all material from Owner's storage point to worksite, including providing internal cement lining on pipes and specials as per specification for cement lining , earthwork in excavation in all types of soil excluding soft rock and hard rock which shall be paid under relevant item for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, edge preparation, providing corrosion protection tape coating as per specification on pipes and specials, laying the pipes in the trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments, and fittings and specials, like elbows, reducers, tees, vents, blind flanges, drains , stub in/ branch connections, alignment, fixing of nuts, bolts, gaskets and washers, including providing pipe joints as per specifications including supply & erection of collars for pipe joints ,welding, corrosion protection tape coating of field joints, cutting of road wherever required & making good the same, testing for the corrosion protection tape coating as per specification, hydrostatic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness , watering, compacting with mechanical means like vibro rammers etc. to 90% of standard proctor density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the Refinery complex limit etc. complete as per drawings, specifications and instructions of Engineer-in- Charge including return of all unused /scrap pipe to owner's storage point (Bare Pipes and fittings shall be supplied by owner as free issue material. Collar sleeves for pipe jointing shall be supplied by contractor. Cement lining of pipes, fittings and specials including supply of all materials shall be in contractor's scope.) (Depth of excavation for pipe trench shall be upto 3.0m).
205Dia. 6 Inch PMS A34Y
206Dia. 8 Inch PMS A34Y
207Dia. 10 Inch PMS A34Y
208Dia. 12 Inch PMS A34Y
209Dia. 4 Inch PMS A34Y
210Cement Lined pipe in RCC trenches
211Laying and joining of Carbon Steel pipes and specials in RCC trench including transportation of all material from Owner's storage point to worksite, including providing internal cement lining on pipes and specials as per specification cutting of pipes if required, edge preparation, providing corrosion protection tape coating as per specification on pipes and specials, laying the pipes in RCC trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments, and fittings and specials, like elbows, reducers, tees, vents, blind flanges, drains, stub in/branch connections, alignment, fixing of nuts, bolts, gaskets and washers, including providing pipe joints as per specifications including supply & erection of collars for pipe joints as per specifications welding, corrosion protection tape coating of field joints, testing for the corrosion protection tape coating as per specification, hydrostatic testing of the system, flushing, complete as per drawings, specifications and instructions of Engineer-in- Charge including return of all unused /scrap pipe to owner's storage point (Bare Pipes and fittings shall be supplied by owner as free issue material. Collar sleeves for pipe jointing shall be supplied by contractor. Cement lining of pipes, fittings and specials including supply of all materials shall be in contractor's scope. Construction of trench, backfilling with sand shall be paid under separate item). For water system pressure piping
212Dia. 6 Inch Pipe Material Class A34Y
213Dia. 10 Inch Pipe Material Class A34Y
214Dia. 8 Inch Pipe Material Class A34Y
215Dia. 12 Inch Pipe Material Class A34Y
216Dia. 4 Inch Pipe Material Class A34Y
217Supply, fabrication and Erection of piping(underground)
218Water System Galvanised Pressure Piping (Under Ground) (Screwed)
219Supplying and laying carbon steel galvanised pipes as per piping materials specification Class underground including supply of all necessory fittings including Tee, reducing Tee, reducing Coupling, nipple, coupling, elbows etc. supply of teflon tapes, PTFE tape, white lead, etc. cutting the pipes to required lengths, making threads, earthwork in excavation for trenches, etc. in all types of soil except soft rock & hard rock including dewatering, shoring and strutting if required, dressing of sides, levelling, grading and ramming of bottoms, including laying of pipes in trenches, jointing the pipes and fittings with threaded connections, hydrostatic testing of the piping, backfilling the trenches with selected/approved earth fill material, cutting of roads wherever required, making good the road surface after laying, disposal of surplus earth at a designated area anywhere within complex limit etc., complete as per specifications, drawings and directions of Engineer-in- Charge. For following Nominal Size and Piping Material Class.
220Nominal Dia 2 Inch Piping class J2A
221Nominal Dia 1.5 Inch Piping class J2A
222Supply, fabrication and Erection of piping (Above ground)
223Miscellaneous G.I. PIPING (ABOVE GROUND)
224Supplying and laying ABOVE GROUND mild steel galvanized pipes as per piping material specification, including supply and installation of reducing tees, fittings, elbows, nipples, Teflon tapes, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes on pipe rack, sleepers, T-supports, erection of piping on technological structures etc. including joining of pipes and fittings with threaded/ flanged connections etc. hydrostatic testing of the piping including supply of necessary fittings etc. and pipe supports complete as per data sheets, specifications, drawings and instructions of Engineer-in-charge.
225Dia. 2 Inch PMS J2A
226Dia. 1.5 Inch PMS J2A
227Supply and installation of valve assembly, flange assembly etc.
228Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge.
229Gate valve assembly for following nominal sizes and piping material class
230Dia. 1.5 Inch PMS J2A
231fire fighting equipment's
232Installation of firefighting equipment including transporting the equipment from Owner's store to work site, fixing of nuts, bolts, washers, gaskets needed for fixing the equipment with matching flange, welding etc. complete as per drawings, specifications and direction of Engineer-in- Charge. (All fire fighting equipment's and accessories shall be supplied by owner)
233Stand Post type fire hydrant ( Double outlet)
234Water/ water cum foam monitor
235Long range water/ water cum foam monitor
236First Aid hose reel (Wall Mounted)
237First Aid hose reel (Floor Mounted)
238Double headed landing valve
239Type-II Hose Box chamber including all items inside the chamber, fixing in position with anchor bolts/ PCC Block in foundation, including all civil works and supply of all materials including cement etc. (hose box and inside accessories supplied free of cost by owner)
240Miscellaneous Items
241Miscellaneous
242Supply and installation of an Air release valve in the piping network, as per the datasheet C068-261-81-45-DS-4017 attached to the tender, as per the standards, specifications, and directions of the Engineer in Charge.
243ARCHITECTURE
244ROOFING
245Providing and fixing A.C. air extractor of approved quality over A.C. sheeting including M.S. frame work, anticorrosive polymer coated G.I. hooks, nuts, bolts, and polymer cap, seal and thrust wshers of approved make, finishing etc. all complete.
246610mm dia extractor.
247Providing and fixing rain water pipes with M.S. holder clamps including fixing/embedding into masonry/concrete, providing connections like shoes, vents, specials, bends etc. fixing in perfect plumb etc. all complete.
248110mm dia O.D. Size. embedded PVC rain water pipe jointed with bonding solution of approved quality and make with pressure rating of 4kg/cm2 including clamps, connections etc. all as per approved manufacturer's details.
249Providing and laying in position approved quality profiled, precoated, steel sheets (for roofing, cladding etc.) made from cold rolled high tensile Zincalume/ Galvalume Steel of 550 MPA yield stress conforming to IS:513, IS:15961 and ASTM AS: 1397; the substrate shall be hot dip metallic coating of aluminium- zinc alloy (150 grams per sq. mtr. Total on both sides, coating class AZ150); the bottom unexposed surface shall be provided with alkyd backer of minimum 5 microns over a 5 micron coat of primer; top exposed surface shall have SDP (Super Durable Polyester) paint system MINIMUM 20 microns in approved shade applied over 5 microns primer; overall coated thickness of sheets not less than 0.52 mm having base metal thickness of minimum 0.45mm (negative tolerance not acceptable), profile depth not less than 28mm and pitch of 195 to 255mm; including cutting, mitering, laps, providing cutouts for fixing accessories, necessary fastners (approved quality anti corrosive polyester polymer coated, rivets, nuts, bolts, self drilling screws/ fasteners with integral washers and EPDM seals, and nylon colour caps and natural cure type joint sealants etc.) All complete as per approved manufacturer's specifications. Note: The steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg name, etc) on back side at regular interval confirming genuinity of the material.
250Providing and laying in position roofing and cladding accessories like ridge piece, corner piece, north light curve piece, apron piece, gutter, flashing etc. fabricated out of 0.5mm precoated Zincalume/ Galvalume Steel steel sheets of same material/ quality etc. as that of sheeting; bent and profiled to match with the roofing and cladding, including all cutting, fabrication, rivetting, fastners etc. all complete.
251Polycarbonate sheets roofing/ cladding:Providing and fixing in position (for roofing and cladding) machine made 2mm thick corrugated polycarbonate sheets (conforming to IS :14434, 14443) of approved manufacturer (in approved shade) extruded from polycarbonate resin, having profiles as approved/ matching exactly with the surrounding pre-coated roofing/ cladding sheets and having following properties:(a) Specific gravity 1.2 g/ cm3 (b) Hardness 119 M Scale(c) Tensile Strength 64 Mpa(d) Compressive strength 66Mpa(e) Impact Strength 900 J/mThe item includes fixing to steel structure members (truss/purlins)/ brick masonry walls by means of polymer coated 'J' or 'L' hooks, bolts, nuts 8mm dia G.I. bitumen washers etc. all complete as per approved manufacturer's recommendations and specifications.
252Barricading of corrugated GI sheet of 0.8mm thickness: Providing and fixing corrugated GI sheet of 0.8mm thickness, minimum 120 GSM coating and conforming to IS : 277 in barricading cladding, corner piece, etc. with 8mm dia `J' or `L' type anticorrosive polymer coated GI hook, bolts, nuts and polymer cap, seal and thrust washer including cutting to proper size, drilling holes, mitering, laps, finishing, providing anticorrosive protective coating on hooks, nuts, bolts etc. and maintaining the same during project execution. After completion of the retention period mentioned elsewhere in the BID document, all materials shall be dismantled and taken away by the contractor outside plant boundary to the complete satisfaction of Engineer-in-charge all complete as per the direction of Engineer-in-charge. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
253GEOTECH
254GROUND IMPROVEMENT
255SAND GRAVEL MIX
256Supplying and filling sand gravel mix (1:1) with approved aggregate below road, RCC pavement, manholes, pits, foundations, bedding of UG piping etc. in layers of 150 mm loose thickness (maximum) including watering, ramming, rolling, compacting to achieve 85% relative density as per IS 2720 Part-XIV, quarrying, royalties, transportation, handling, etc. all complete as per drawings, specifications and directions of Engineer-in-Charge.(The rate shall be inclusive of the cost of all labour, material, equipment etc. all complete)
257Part B: Civil & Structural works in Units (SWS/ARU & ROG-PSA)
258STRUCTURAL
259EARTH WORK (REFER SPECIFICATION NO. 6-68-0003)
260Earthwork excavation in soil
261Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
262Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
263Earthwork excavation in soft rock
264Earth work in EXCAVATION below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
265Earth work in EXCAVATION below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth beyond 1.5m and upto & inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
266SHORING AND STRUTTING
267Providing and installing approved type of \\"SHORING AND STRUTTING\\" by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed.
268Providing and installing approved type of \\"SHORING AND STRUTTING\\" by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed.
269Backfilling after execution of work
270BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.
271BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.
272BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 500M AND UPTO & INCLUSIVE OF 1KM including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.
273Transporting & Disposing the SURPLUS EARTH AND DEBRIS
274Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids).
275Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids).
276\\"Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction areas to areas ANYWHERE OUTSIDE THE PLANT BOUNDARY, including re-excavating the deposited soil excavated earlier, loading, transportation, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). DISPOSAL AREAS OUTSIDE PLANT BOUNDARY TO BE ARRANGED BY THE CONTRACTOR. Royalty as applicable for disposal outside plant limits to be borne by the Contractor.\\"
277Transportation of ROCK material
278Transportation of ROCK material coming out of operation of item Nos. 01CS.1.2 to 01CS.1.5 BEYOND INITIAL LEAD OF 100M AND UPTO 1KM to the area of disposal including loading, unloading, laying at all depths and heights, stacking, spreading, levelling at an area of disposal as directed. For carting on the basis of Truck Measurements (volume of truck reduced by 50% for voids).
279Transportation of ROCK material coming out of operation of item Nos. 01CS.1.2 to 01CS.1.5 beyond initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM to the area of disposal including loading, unloading, laying at all depths and heights, stacking, spreading, levelling at an area of disposal as directed. For carting on the basis of Truck Measurements (volume of truck reduced by 50% for voids).
280Transportation of ROCK material coming out of operation of item Nos. 01CS.1.2 to 01CS.1.5 UPTO the area of disposal ANYWHERE OUTSIDE THE PLANT BOUNDARY including loading, unloading, laying at all depths and heights, stacking, spreading, levelling at an area of disposal as directed. For carting on the basis of Truck Measurements (volume of truck reduced by 50% for voids). DISPOSAL AREAS OUTSIDE PLANT BOUNDARY TO BE ARRANGED BY THE CONTRACTOR. Royalty as applicable for disposal outside plant limits to be borne by the Contractor.
281Earthwork Manual Excavation in SOIL
282Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
283Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
284Earthwork Manual Excavation in SOFT ROCK
285Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
286Earth work in EXCAVATION BY MANUAL MEANS below ground level for all kinds of works in SOFT ROCK as classified in specification for a depth beyond 1.5m and upto & inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.
287PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004)
288PCC - Non FIM Items
289Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
290Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
291RCC Substrutures - Non FIM Items
292Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
293Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
294RCC Superstructures - Non FIM Items
295Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
296Providing and laying REINFORCED CEMENT CONCRETE OF M-35 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS MORE THAN 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.
297Precast Elements - Non FIM Items
298Manufacturing, transporting, supplying and erecting in position Reinforced Cement Concrete PRECAST ELEMENTS such as columns, beams, cover slabs, lintels, louvers, fins, shelves etc. of M-35 grade with 20mm and down size graded crushed stone aggregates/gravel, each unit upto and inclusive of 500 kg. for all leads, levels, shapes and thickness including all moulds, shuttering and centering, vibrating, tamping, curing, chamfering wherever required, finishing the top surface with cement mortar 1:3 (1 Cement : 3 Sand) to give a smooth and even surface, or non skid finish as specified, providing lifting hooks, metal inserts, making holes pockets, (only M.S. inserts to be measured & paid separately) transporting to site, erecting, levelling, aligning and fixing in position with cement mortar 1:3 ( Cement : 3 Coarse Sand), breaking bricks and/or concrete surfaces and making good the same etc. all complete (excluding the Cost of Reinforcement ) and as directed. All materials including cement supplied by the contractor.
299Manufacturing, transporting, supplying and erecting in position Reinforced Cement Concrete PRECAST ELEMENTS such as columns, beams, cover slabs, lintels, louvers, fins, shelves etc. of M-35 grade with 20mm and down size graded crushed stone aggregates/gravel, each unit beyond 500 kg and upto and inclusive of 1000 kg. for all leads, levels, shapes and thickness including all moulds, shuttering and centering, vibrating, tamping, curing, chamfering wherever required, finishing the top surface with cement mortar 1:3 ( 1 Cement : 3 Sand) to give a smooth and even surface, or non skid finish as specified, providing lifting hooks, metal inserts, making holes pockets, (only M.S. inserts to be measured & paid separately) transporting to site, erecting, levelling, aligning and fixing in position with cement mortar 1:3 ( Cement : 3 Coarse Sand), breaking bricks and/or concrete surfaces and making good the same etc. all complete (excluding the Cost of Reinforcement ) and as directed. All materials including cement supplied by the contractor.
300HYD Bars / MS Bars - Non FIM Items
301Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIALIN CONTRACTOR'S SCOPE.
302Centering and Shuttering - Non FIM Items
303Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed.
304Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed.
305Expansion joints - Non FIM Items
306Providing 20mm wide EXPANSION JOINTS in flooring and pavement slabs and ISOLATION JOINTS around equipment foundations/columns/pedestal/trenches etc. including cleaning the joints of all loose material, filling clean sand for the full depth of slab (upto and inclusive of 300 mm) except for 12mm depth from top and sealing the top 12mm with approved two part liquid polysulphide Sealing Compound as per IS:12118 etc. all complete as shown, specified and directed.
307STRUCTURAL STEEL WORKS SPEC NO. 6-68-0006
308General Steel Works - Non FIM Items
309Supplying, Fabricating at CONTRACTOR's shop outside the plant boundary, transporting fabricated items to site, unloading, storing, erecting in position and testing/ examining , bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250A / E250BR / E250B0 (conforming to IS:2062 at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc.. all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
310Supplying, Fabricating at CONTRACTOR's shop outside the plant boundary, transporting fabricated items to site, unloading, storing, erecting in position and testing/ examining , bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250A / E250BR / E250B0 (conforming to IS:2062 at all locations and levels MORE THAN 20 m ABOVE HPP/ FGL including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc.. all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
311Painting - Non FIM Items
312Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 10.2 of Table 10.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 7.2.1 of Table 7.2 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable), for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COSTAL) areas considering environmental classification as INDUSTRIAL MARINE. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on Structural steel weight).
313Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 8.1 of Table 8.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) for painting over the coat of shop primer & galvanisation already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on weight of steel).
314Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. no. 10.2 of Table 10.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of self priming type surface tolerant high build epoxy coating F-8, 100micron DFT, over the damaged area requiring repair/rectification, including storage, surface preparation as per ST.2, degreasing, cleaning, drying, providing necessary arrengement for access, testing etc., for steel structures (excluding ladders, spiral stairways & handrails) at all location & levels, all complete as specified, in OFFSITE (COASTAL) areas as well as UNIT (COASTAL & INLAND) areas considering environmental classification as INDUSTRIAL MARINE. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on surface area in Sqm)
315Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. no. 8.1 of Table 8.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of self priming type surface tolerant high build epoxy coating F-8, 100micron DFT, over the damaged area requiring repair/rectification, including storage, surface preparation as per ST.2, degreasing, cleaning, drying, providing necessary arrengement for access, testing etc. for HANDRAIL, LADDERS & SPIRAL STAIRWAYS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on surface area in Sqm)
316Barricading Structure - Non FIM Item
317Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS FOR BARRICADING, of Grade E250A / E250BR / E250B0 (conforming to IS:2062) and/ or CFSHS/ CFRHS of Grade YSt 310 (conforming to IS:4923) and/ or CFCHS of Grade YSt 310 (conforming to IS:1161) at all locations and levels, including all built-up sections/ compound/ hollow/ tubular sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks for isolating the construction area, cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Non-shrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting and applying pre-erection/ shop primer as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc., AND maintaining the structure during project execution AND dismantling, removing & taking away all materials outside the plant boundary after completion of the project, to the complete satisfaction of Engineer-in- charge all complete as per the direction of Engineer-in-Charge. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
318STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007)
319Yst310 IS 4923
320Supplying, Fabricating at contractor's workshop outside plant boundary, mock assembly, protective packing after applying primer, transporting fabricated items to site, and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS, USING COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS:4923, Grade Yst 310 ( Raw material used for these steel shall be hot rolled coil of min Yst=310 MPa) of approved make, including all built-up sections/ compound sections made out of rolled sections and/or plates/ bent plates, in all types of structural frameworks, truss, floor beams, stairs, sag rods, ladders or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, welding/bolting of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, including preparation and submission of detailed fabrication drawings, planning location of splices in structural assembly to suit transportation ease and minimum number of joints at site, preparing the surface for painting (SSPC-SP-10), applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) after fabrication etc. all complete. Identification of the prefabricated items supplied to site as per design drawings at construction site to facilitate storage/erection by others. SUPPLY OF ALL MATERIAL INCLUDING GALVANIZED NUTS, WASHER AND BOLTS FOR FIELD BOLTED JOINTS IS IN CONTRACTOR'S SCOPE. (ALL FIELD CONNECTION SHALL BE BOLTED CONNECTION UNLESS OTHERWISE MENTION IN AFC/ APPROVED FABRICATION DRAWING).
321MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008
322Anchor Bolts - FIM Items
323Fixing and keeping in position at all levels and locations already fabricated THREADED ANCHOR BOLTS of all diameters and nomenclature supplied by the owner as Free Issue including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including transporting the same from owner's store/issue points to site of work handling , straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed. (BOLTS SHALL BE SUPPLIED BY THE OWNER AS FREE ISSUE).
324Anchor Bolts - Non FIM Items
325Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
326MS Grating Cat. A,B - Non FIM Items
327Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturer's supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE.
328Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings.
329Hand Railing 1000mm - Non FIM Items
330Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
331Supplying, fabricating and fixing in position (to already erected vertical posts for Hand Railing) at all locations ONLY TOP RAIL 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, welding, bending, surface preparation, shop primer as per EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
332Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
333Hand Railing 500mm - Non FIM Items
334Supplying, fabricating and fixing in position at all locations 500mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS:4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
335Mechanical Anchor fastners - Non FIM Items
336\\"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
337\\"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
338Chemical Anchor Fastner
339\\"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
340\\"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 24mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\\"
341Threaded bolts for equipment fixing-Non FIM
342Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
343DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012)
344RCC - Non FIM Items
345Making cut-outs in RCC slab/ wall upto a thickness of 400mm (taking all necessary safety precautions) by vibration-less spark-free mechanical means like core- cutting, wet cutting by diamond wall saw system at all depths & heights including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, disposal of unserviceable material, plastering & finishing the cut surfaces, all complete as specified and directed by the Engineer-in- Charge (Measurement on Plan/ Elevation Area basis).
346Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).
347Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).
348Pockets - Non FIM Items
349Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed.
350PCC _ Non FIM Items
351Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).
352Steelwork - Non FIM Items
353Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed.
354AC / GI Sheets - Non FIM Items
355Dismantling GI/asbestos/translucent sheets, ridges, gutters etc. (taking all necessary safety precautions) in roofings and wall claddings, including supply of all tools & tackles, necessary scaffolding, consumables, cutting (by flame or saw) of fixing hooks, transporting and stacking the serviceable materials, cleaning the site and disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete for all levels, as specified and directed.
356MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013)
357Sand Filling - Non FIM Items
358Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete .
359BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE
360Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturer's specification for protection of reinforcement against corrosion. Supply of admixture in Contractor's scope.
361SAFETY (REFER EIL SPECIFICATION)
362Safety Structures - Non FIM Items
363Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers.
364Providing of steel scaffold stair tower system with minimum 800 mm wide flights, landings at every 1.5 to 2.0 m height, handrailing around flights and landings for safe access upto a height of 12.0 m, all complete including supply of all materials, tools & tackles, manpower etc., at the location directed by Engineer-in-Charge on monthly rental basis. Rental charges shall be payable after completion of erection of the system and acceptance by the Engineer-in- Charge. Rates shall also be inclusive of dismantling of the system and taking out all materials from the project permises as directed by the Engineer-in-Charge. Rate quoted shall be for Running Meter (Height) per month.
365GENERAL CIVIL
366CONCRETE PAVEMENTS
367Providing and laying Reinforced Cement Concrete with 20mm and down size graded crushed stone aggregates in flooring, pavements etc. including leaving pockets, if necessary, making recess/drains, laying in alternate panels, etc. for all depths including shuttering, tamping, curing, etc. as specified in any shape, thickness, position and finishing the top surface smooth etc. all complete as per drawings, specifications and directions of Engineer-in- Charge.
368For RCC of M-30 grade concrete(all materials including cement but excluding cost of providing & fixing reinforcement and joint sealing shall be supplied by the contractor).
369Supplying and laying of 150 micron thick HM HDPE (Grade- I) FILM lining conforming to IS 10889 below concrete pavements, Hard stand, at any other place etc. including royalties, taxes, handling, transportation, unloading, storage, joining etc. all complete as per drawings, manufacturer's specifications and directions of Engineer-in- charge.
370Supply of all materials and Construction of DRY LEAN CEMENT CONCRETE SUB-BASE (7 days compressive strength of 10.0 MPa) with 26.5mm and down size aggregate including cement , water, and approved additives on a prepared sub-grade, mixed in batching plant, transported to site, for all leads & lifts, laid, compacted, finished and cured etc. complete as per IRC:SP:49 (Guidelines for the use of Dry Lean Concrete as Sub-Base), drawings, standards, specifications and directions of Engineer-in-charge.
371Providing 20mm wide Expansion Joints in pavement slabs as per standard/ drawing including cleaning the joints of all loose material, filling with 20mm thick impregnated fibre boards for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. all complete as per drawings, specifications and directions of Engineer-in-Charge.
372For type-I pavement (Upto and inclusive of thickness of 200 mm).(Including providing and laying MS dowel bar, painting as required, GI pipe and cap and cotton waste).
373For type-II pavement (Upto and inclusive of thickness of 150 mm)
374For type-III pavement (Upto and inclusive of thickness of 100 mm).
375For thickened pavement (Upto and inclusive of thickness of 300 mm).
376Providing joints in pavements and around foundations as per standard/ drawing including cleaning the joints of all loose materials and sealing with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in- Charge for.
377Construction joints 20mm wide x 25mm deep.
378Sealing joint around pedestal and column etc. 20mm wide x 200 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge.
379Sealing joint around pedestal and column etc. 20mm wide x 150 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge.
380Sealing joint around pedestal and column etc. 20mm wide x 100 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge for.
381Sealing joint around pedestal and column etc. 20mm wide x 300 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge for.
382Sealing joint around precast cover etc. 10mm wide and for full depth of slab (upto and inclusive of 300 mm) including filling with clean sand for the full depth of slab except for 10mm depth from top and sealing the top 10mm with Polysulphide base joint sealant of approved make conforming to BS:5212, including applying 2 coats of approved primer compatible with the brand of Polysulphide etc. complete as per drawings, specifications and directions of Engineer-in-Charge for.
383Supply of forged/ cast fittings
384Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owner's stores/workspot etc. all complete as per the directions of Engineer-in- Charge.
385Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class
386Dia. 6 Inch Pipe Class J91A
387Dia. 8 Inch Pipe Class J91A
388Dia. 4 Inch Pipe Class J91A
389Dia. 1 Inch Pipe Class J91A
390Dia. 3 Inch Pipe Class J91A
391Supplying the following blind flange assembly consisting of flange, blind flange, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class
392Dia. 1 Inch Pipe Class J91A
393Dia. .5 Inch Pipe Class J91A
394Dia. .75 Inch Pipe Class J91A
395MISCELLANEOUS ITEMS
396Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge.
397NDT Testing
398DYE PENETRATION / MAGNETIC PARTICLE TEST Performing of magnetic particle test or dye penetration test including supply of all necessary materials, equipment and labour for carrying out the work as per specs. and direction of Engineer-in -charge
399DP TEST LENGTH(BW&SW)
400MAGNETIC PARTICLE TEST
401RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specifications and instructions of Engineer-in- Charge. Radiographs shall be submitted to the Engineer-in- charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractor's fault and for additional radiography necessitated due to poor performance of contractor's welders shall be done at contractor's cost) Note: Unit for radiography quantity is 'Nos of circumferential weld joints'.
402FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING)
403Nominal Dia. 4 Inch
404Nominal Dia. 6 Inch
405Nominal Dia. 2 Inch
406Nominal Dia. 1 Inch
407Nominal Dia. 16 Inch
408Nominal Dia. 18 Inch
409Nominal Dia. 1.5 Inch
410FOR JOINTS THK. > 8 (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING)
411Nominal Dia. 8 Inch
412Nominal Dia. 12 Inch
413Nominal Dia. 16 Inch
414Nominal Dia. 10 Inch
415Nominal Dia. 14 Inch
416Portable/ trolley mounted Extinguishers
417Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge.
418Capacity in Kg 9
419Capacity in Kg 6
420Supply and installing in position, trolley mounted DCP (Dry Chemical Powder Type) extinguisher including transporting to worksite, placing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge.
421Capacity in Kg 50
422Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge.
423Capacity in Kg 4.5
424Tank Fire Protection
425Supplying and Installation of aluminum alloy foam couplings with inbuilt NRV having one number 63.5mm (2-1/2\\") male instantaneous type inlet coupling conforming to IS:903 with flanged outlet connection including supply of nuts, bolts, gaskets, washers as per drawings, specifications and direction of Engineer-in-Charge. For the following flanged outlet dia. in inch
426Outlet Dia. (Nominal) 3 Inch
427Fabrication and Erection of piping (underground)
428FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owner's storage point to worksite, earthwork in excavation in all types of soil EXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re- excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owner's storage point (Pipes and fittings shall be supplied by owner as free issue material.) (Depth of excavation for pipe trench shall be upto 3.0m)
429Carbon Steel Piping (Non IBR), Thickness <=10 mm
430Fabrication, For the following nominal sizes
431NB 2 inch - 6 inch
432NB 8 inch - 14 inch
433Erection including corrosion protection coating, for Water System (Pressure Piping), For following Nominal Sizes
434NB 2 inch - 6 inch
435NB 8 inch - 14 inch
436Cement Lined Pipe
437Laying and joining of Carbon Steel pipes and specials underground including preparing requisite spools, transportation of all material from Owner's storage point to worksite, including providing internal cement lining on pipes and specials as per specification for cement lining , earthwork in excavation in all types of soil excluding soft rock and hard rock which shall be paid under relevant item for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, edge preparation, providing corrosion protection tape coating as per specification on pipes and specials, laying the pipes in the trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments, and fittings and specials, like elbows, reducers, tees, vents, blind flanges, drains , stub in/ branch connections, alignment, fixing of nuts, bolts, gaskets and washers, including providing pipe joints as per specifications including supply & erection of collars for pipe joints ,welding, corrosion protection tape coating of field joints, cutting of road wherever required & making good the same, testing for the corrosion protection tape coating as per specification, hydrostatic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness , watering, compacting with mechanical means like vibro rammers etc. to 90% of standard proctor density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the Refinery complex limit etc. complete as per drawings, specifications and instructions of Engineer-in- Charge including return of all unused /scrap pipe to owner's storage point (Bare Pipes and fittings shall be supplied by owner as free issue material. Collar sleeves for pipe jointing shall be supplied by contractor. Cement lining of pipes, fittings and specials including supply of all materials shall be in contractor's scope. )(Depth of excavation for pipe trench shall be upto 3.0m)
438Dia. 6 Inch PMS A34Y
439Dia. 8 Inch PMS A34Y
440Dia. 10 Inch PMS A34Y
441Dia. 12 Inch PMS A34Y
442Dia. 4 Inch PMS A34Y
443Cement Lined pipe in RCC trenches
444Laying and joining of Carbon Steel pipes and specials in RCC trench including transportation of all material from Owner's storage point to worksite, including providing internal cement lining on pipes and specials as per specification cutting of pipes if required, edge preparation, providing corrosion protection tape coating as per specification on pipes and specials, laying the pipes in RCC trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments, and fittings and specials, like elbows, reducers, tees, vents, blind flanges, drains, stub in/ branch connections, alignment, fixing of nuts, bolts, gaskets and washers, including providing pipe joints as per specifications including supply & erection of collars for pipe joints as per specifications welding, corrosion protection tape coating of field joints, testing for the corrosion protection tape coating as per specification, hydrostatic testing of the system, flushing, complete as per drawings, specifications and instructions of Engineer-in- Charge including return of all unused /scrap pipe to owner's storage point (Bare Pipes and fittings shall be supplied by owner as free issue material. Collar sleeves for pipe jointing shall be supplied by contractor. Cement lining of pipes, fittings and specials including supply of all materials shall be in contractor's scope. Construction of trench, backfilling with sand shall be paid under separate item). For water system pressure piping
445Dia. 6 Inch Pipe Material Class A34Y
446Dia. 10 Inch Pipe Material Class A34Y
447Dia. 8 Inch Pipe Material Class A34Y
448Dia. 12 Inch Pipe Material Class A34Y
449Dia. 4 Inch Pipe Material Class A34Y
450Supply, fabrication and Erection of piping(underground)
451Water System Galvanised Pressure Piping (Under Ground) (Screwed)
452Supplying and laying carbon steel galvanised pipes as per piping materials specification Class underground including supply of all necessory fittings including Tee, reducing Tee, reducing Coupling, nipple, coupling, elbows etc. supply of teflon tapes, PTFE tape, white lead, etc. cutting the pipes to required lengths, making threads, earthwork in excavation for trenches, etc. in all types of soil except soft rock & hard rock including dewatering, shoring and strutting if required, dressing of sides, levelling, grading and ramming of bottoms, including laying of pipes in trenches, jointing the pipes and fittings with threaded connections, hydrostatic testing of the piping, backfilling the trenches with selected/approved earth fill material, cutting of roads wherever required, making good the road surface after laying, disposal of surplus earth at a designated area anywhere within complex limit etc., complete as per specifications, drawings and directions of Engineer-in- Charge. For following Nominal Size and Piping Material Class.
453Nominal Dia 2 Inch Piping class J2A
454Nominal Dia 1.5 Inch Piping class J2A
455Nominal Dia 2 Inch Piping class J91A
456Nominal Dia 3 Inch Piping class J91A
457Nominal Dia 4 Inch Piping class J91A
458Nominal Dia 1 Inch Piping class J91A
459Supplying and laying carbon steel galvanized pipes for Fire water spray system/ sprinkler system/ detection system as per piping material specification, UNDER GROUND, including supply of all necessary fittings such as tees, reducing tees, reducing couplings, couplings, elbows, nipples, Teflon tapes, PTFE tape, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes in RCC TRENCHES, joining of pipes and fittings with threaded/flanged connection, gaskets and bolts, hydrostatic testing of the piping including supply of necessary fittings etc. complete as per specifications, drawings and instructions of Engineer-in-charge For following nominal sizes and piping material class. (Construction of trench, backfilling with sand shall be paid under separate item).
460Nominal Dia 2 Inch Piping Class J91A
461Nominal Dia 3 Inch Piping Class J91A
462Nominal Dia 4 Inch Piping Class J91A
463Nominal Dia 1 Inch Piping Class J91A
464Water System Galvanised Pressure Piping (Under Ground) (Welded)
465Supplying and laying carbon steel galvanised pipes as per piping materials specification Class underground including supply of all necessory fittings including Tee, reducing Tee, reducuing Coupling, nipple, coupling, elbows etc., cutting the pipes to required lengths,welding, providing cold galvanising with zinc coating compound on surfaces where galvanising has been burnt off, earthwork in excavation for trenches, etc. in all types of soil except soft rock and hard rock, including dewatering, shoring and strutting if required, dressing of sides, levelling, grading and ramming of bottoms, including laying of pipes in trenches, jointing the pipes and fittings with welded/ flanged connections, hydrostatic testing of the piping, backfilling the trenches with selected/approved earth fill material, cutting of roads wherever required, making good the road surface after laying, disposal of surplus earth at a designated area anywhere within complex limit etc., complete as per specifications, drawings and directions of Engineer-in- Charge. For following Nominal Size and Piping Material Class .
466Nominal Dia 6 Inch Piping class J91A
467Nominal Dia 8 Inch Piping class J91A
468Supplying and laying carbon steel galvanized pipes for Fire water spray system/ sprinkler system/ detection system as per piping material specification, UNDER GROUND, including supply of all necessary fittings such as tees, reducing tees, reducers, couplings, elbows, nipples etc., cutting the pipes to required lengths, welding, providing cold galvanising with zinc coating compound on surfaces where galvanising has been burnt off, including laying of pipes in RCC TRENCHES, joining of pipes and fittings with welded/ flanged connections, gaskets and bolts, hydrostatic testing of the piping including supply of necessary fittings etc. complete as per specifications, drawings and instructions of Engineer-in-charge For following nominal sizes and piping material class. (Construction of trench, backfilling with sand shall be paid under separate item).
469Nominal Dia 6 Inch Piping class J91A
470Nominal Dia 8 Inch Piping class J91A
471Supply, fabrication and Erection of piping (Above ground)
472Fire water spray/ sprinkler/ detection system G.I. PIPING A/G (Screwed)
473Supplying and laying ABOVE GROUND mild steel galvanized pipes for Fire water spray system/ sprinkler system/ detection system as per piping material specification including supply of reducing tees, fittings, elbows, nipples, Teflon tapes, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes on pipe rack, sleepers, T-supports, erection of piping on equipments, pumps etc. including joining of pipes and fittings with threaded/flanged connections, including installation of spray nozzles, Quartzoid bulb detectors, restriction orifice, flanges, break-up flanges, gaskets and bolts, hydrostatic testing of the piping including supply of necessary fittings etc. complete as per specifications, drawings and instructions of Engineer-in-charge.(Spray nozzles, restriction orifice, flanges and break-up flanges shall be paid separately under separate SOR/ shall be given as free issue to the contractor.) For following nominalsizes and piping material class.
474Dia. .75 Inch PMS J91A
475Dia. 1 Inch PMS J91A
476Dia. 1.5 Inch PMS J91A
477Dia. 2 Inch PMS J91A
478Dia. 3 Inch PMS J91A
479Dia. 4 Inch PMS J91A
480Dia. .5 Inch PMS J91A
481Miscellaneous G.I. PIPING (ABOVE GROUND)
482Supplying and laying ABOVE GROUND mild steel galvanized pipes as per piping material specification, including supply and installation of reducing tees, fittings, elbows, nipples, Teflon tapes, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes on pipe rack, sleepers, T-supports, erection of piping on technological structures etc. including joining of pipes and fittings with threaded/ flanged connections etc. hydrostatic testing of the piping including supply of necessary fittings etc. and pipe supports complete as per data sheets, specifications, drawings and instructions of Engineer-in-charge.
483Dia. 1 Inch PMS J2A
484Dia. 1.5 Inch PMS J2A
485Fire water spray/ sprinkler/ detection system G.I. PIPING A/G (Welded)
486Supplying and laying ABOVE GROUND mild steel galvanized pipes for Fire water spray system/ sprinkler system/ detection system as per piping material specification including supply of reducing tees, fittings, elbows, nipples, Teflon tapes, white lead etc., cutting the pipes to required lengths, welding, applying zinc silicate coating on welded joints, including laying of pipes on pipe rack, sleepers, T-supports, erection of piping on equipments, pumps etc. including joining of pipes and fittings with welded/flanged connections, including installation of spray nozzles, Quartzoid bulb detectors, restriction orifice, flanges, break-up flanges, gaskets and bolts, hydrostatic testing of the piping including supply of necessary fittings etc. complete as per specifications, drawings and instructions of Engineer-in-charge.(Spray nozzles, restriction orifice, flanges and break-up flanges shall be paid separately under separate SOR/ shall be given as free issue to the contractor.). For following nominal sizes and piping material class.
487Nominal Dia. 6 Inch Piping Material Class J91A
488Nominal Dia. 8 Inch Piping Material Class J91A
489Supply and installation of valve assembly, flange assembly etc.
490Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge.
491Gate valve assembly for following nominal sizes and piping material class
492Dia. 1.5 Inch PMS J2A
493Dia. 1 Inch PMS J91A
494Dia. 2 Inch PMS J91A
495Dia. 3 Inch PMS J91A
496Dia. .75 Inch PMS J91A
497Supplying the flange assembly conforming to piping material specifications and delivering the same to owner's stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class
498Dia. 1 Inch PMS J91A
499Dia. 2 Inch PMS J91A
500Dia. 3 Inch PMS J91A
501Dia. 4 Inch PMS J91A
502Dia. 6 Inch PMS J91A
503Dia. 8 Inch PMS J91A
504fire fighting equipment's
505Installation of Deluge Valve Skid
506Installation, erection, testing and commissioning of deluge valve assembly Skid actuated through wet detection/ air detection system including placing the skid at the dsignated location and fixing with anchoring bolts, connecting the water inlet and system piping, connecting detection network piping, fittings etc. complete for deluge valve skid assembly as per specification, drawings and directions of Engineer-in-Charge. (Deluge valve skid fitted with all instruments & piping/ valves shall be provided as free issue to the contractor.)
507Nominal Dia of Deluge Valve 4 Inch
508Nominal Dia of Deluge Valve 6 Inch
509Nominal Dia of Deluge Valve 3 Inch
510Installation of firefighting equipment including transporting the equipment from Owner's store to work site, fixing of nuts, bolts, washers, gaskets needed for fixing the equipment with matching flange, welding etc. complete as per drawings, specifications and direction of Engineer-in- Charge. (All fire fighting equipment's and accessories shall be supplied by owner)
511Stand Post type fire hydrant ( Double outlet)
512Water/ water cum foam monitor
513Long range water/ water cum foam monitor
514First Aid hose reel (Wall Mounted)
515First Aid hose reel (Floor Mounted)
516Double headed landing valve
517Type-II Hose Box chamber including all items inside the chamber, fixing in position with anchor bolts/ PCC Block in foundation, including all civil works and supply of all materials including cement etc. (hose box and inside accessories supplied free of cost by owner)
518Supply and installation of medium velocity spray nozzles with 1/2\\" NPT fixing arrangement including transportation to worksite from Owner's storage point, testing, flushing etc. all complete as per specification, drawings, data sheet and directions of Engineer-in-Charge. For nozzle of following K factor
519K factor 18
520K factor 30
521Quartzoid bulb detectors
522Supply, installation, testing and commissioning of quartzoid bulb detectors with 1/2\\" NPT fixing arrangement at locations as per data sheets, drawings and directions of Engineer-in-Charge.
523Actuation Temperature 79 °C
524Miscellaneous Items
525Miscellaneous
526Supply and installation of an Air release valve in the piping network, as per the datasheet C068-261-81-45-DS-4017 attached to the tender, as per the standards, specifications, and directions of the Engineer in Charge.
527ARCHITECTURE
528ROOFING
529Providing and fixing A.C. air extractor of approved quality over A.C. sheeting including M.S. frame work, anticorrosive polymer coated G.I. hooks, nuts, bolts, and polymer cap, seal and thrust wshers of approved make, finishing etc. all complete.
530610mm dia extractor.
531Providing and fixing rain water pipes with M.S. holder clamps including fixing/embedding into masonry/concrete, providing connections like shoes, vents, specials, bends etc. fixing in perfect plumb etc. all complete.
532110mm dia O.D. Size. embedded PVC rain water pipe jointed with bonding solution of approved quality and make with pressure rating of 4kg/cm2 including clamps, connections etc. all as per approved manufacturer's details.
533Providing and laying in position approved quality profiled, precoated, steel sheets (for roofing, cladding etc.) made from cold rolled high tensile Zincalume/ Galvalume Steel of 550 MPA yield stress conforming to IS:513, IS:15961 and ASTM AS: 1397; the substrate shall be hot dip metallic coating of aluminium- zinc alloy (150 grams per sq. mtr. Total on both sides, coating class AZ150); the bottom unexposed surface shall be provided with alkyd backer of minimum 5 microns over a 5 micron coat of primer; top exposed surface shall have SDP (Super Durable Polyester) paint system MINIMUM 20 microns in approved shade applied over 5 microns primer; overall coated thickness of sheets not less than 0.52 mm having base metal thickness of minimum 0.45mm (negative tolerance not acceptable), profile depth not less than 28mm and pitch of 195 to 255mm; including cutting, mitering, laps, providing cutouts for fixing accessories, necessary fastners (approved quality anti corrosive polyester polymer coated, rivets, nuts, bolts, self drilling screws/ fasteners with integral washers and EPDM seals, and nylon colour caps and natural cure type joint sealants etc.) All complete as per approved manufacturer's specifications. Note: The steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg name, etc) on back side at regular interval confirming genuinity of the material.
534Providing and laying in position roofing and cladding accessories like ridge piece, corner piece, north light curve piece, apron piece, gutter, flashing etc. fabricated out of 0.5mm precoated Zincalume/ Galvalume Steel steel sheets of same material/ quality etc. as that of sheeting; bent and profiled to match with the roofing and cladding, including all cutting, fabrication, rivetting, fastners etc. all complete.
535Polycarbonate sheets roofing/ cladding: Providing and fixing in position (for roofing and cladding) machine made 2mm thick corrugated polycarbonate sheets (conforming to IS :14434, 14443) of approved manufacturer (in approved shade) extruded from polycarbonate resin, having profiles as approved/ matching exactly with the surrounding pre-coated roofing/ cladding sheets and having following properties:(a) Specific gravity 1.2 g/ cm3 (b) Hardness 119 M Scale(c) Tensile Strength 64 Mpa(d) Compressive strength 66Mpa(e) Impact Strength 900 J/mThe item includes fixing to steel structure members (truss/ purlins)/ brick masonry walls by means of polymer coated 'J' or 'L' hooks, bolts, nuts 8mm dia G.I. bitumen washers etc. all complete as per approved manufacturer's recommendations and specifications.
536Barricading of corrugated GI sheet of 0.8mm thickness: Providing and fixing corrugated GI sheet of 0.8mm thickness, minimum 120 GSM coating and conforming to IS : 277 in barricading cladding, corner piece, etc. with 8mm dia `J' or `L' type anticorrosive polymer coated GI hook, bolts, nuts and polymer cap, seal and thrust washer including cutting to proper size, drilling holes, mitering, laps, finishing, providing anticorrosive protective coating on hooks, nuts, bolts etc. and maintaining the same during project execution. After completion of the retention period mentioned elsewhere in the BID document, all materials shall be dismantled and taken away by the contractor outside plant boundary to the complete satisfaction of Engineer-in-charge all complete as per the direction of Engineer-in-charge. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
537GEOTECH
538GROUND IMPROVEMENT
539SAND GRAVEL MIX
540Supplying and filling sand gravel mix (1:1) with approved aggregate below road, RCC pavement, manholes, pits, foundations, bedding of UG piping etc. in layers of 150 mm loose thickness (maximum) including watering, ramming, rolling, compacting to achieve 85% relative density as per IS 2720 Part-XIV, quarrying, royalties, transportation, handling, etc. all complete as per drawings, specifications and directions of Engineer-in-Charge.(The rate shall be inclusive of the cost of all labour, material, equipment etc. all complete)
541\\"NOTE:-THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST.\\" Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58224323
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 7.09 Crore
LAST DATE 23-11-2026
Authority
Authority Name Bridge And Roof Company India Limited
Work Description Tender for Works Contract For Civil & Structural Works Including Supply Of All Materials In Connection With Mechanical Works For Lube Modernization & Bottom Upgradation (Lmbu) Project Of Hpcl, Mumbai Refinery, India
Basic Detail
Tender No BANDR/HO/71174/CIVIL AND STRL/HPCL/MUMBAI/NIT/SC/01
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 16 Nov 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 7.09 Crore
Tender Fee 19470
EMD 16.12 Lakhs
Exemption Not Available
Document List
BOQ_979304.xls
c3f83fa7-8ab2-4476-ada5-23a6d1b2dbf7.html
eNIT_CIVIL_STRL_WORK_7117_1.pdf
Spec_Part1.pdf
Spec_Part10.pdf
Spec_Part11.pdf
Spec_Part12.pdf
Spec_Part2.pdf
Spec_Part3.pdf
Spec_Part4.pdf
Spec_Part5.pdf
Spec_Part6.pdf
Spec_Part7.pdf
Spec_Part8.pdf
Spec_Part9.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_979304.xls

html

c3f83fa7-8ab2-4476-ada5-23a6d1b2dbf7.html

pdf

eNIT_CIVIL_STRL_WORK_7117_1.pdf

pdf

Spec_Part1.pdf

pdf

Spec_Part10.pdf

pdf

Spec_Part11.pdf

pdf

Spec_Part12.pdf

pdf

Spec_Part2.pdf

pdf

Spec_Part3.pdf

pdf

Spec_Part4.pdf

pdf

Spec_Part5.pdf

pdf

Spec_Part6.pdf

pdf

Spec_Part7.pdf

pdf

Spec_Part8.pdf

pdf

Spec_Part9.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender