Tender For Boq : Repairing Of Urban Health & Wellness Centre At Naamkum In Ward No.02, Under Nagar Panchayat Khunti 2026-2027
Tender Value
22.77 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
5 days left
EMD
45550
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khunti → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Boq : Repairing Of Urban Health & Wellness Centre At Naamkum In Ward No.02, Under Nagar Panchayat Khunti 2026-2027
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 2 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M +25M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 3 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 4 | Providing designation 75B one brick on Edge soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 6 | Providing designation 75B work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in superstructure with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 13 | Providing TMT steel reinforcement above 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. 8 mm dia |
| 14 | 10mm dia |
| 15 | 12 to 25 MM DIA |
| 16 | Providing 1.5mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/L. |
| 17 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 19 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 20 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 21 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 22 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 23 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 24 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 25 | Providing and laying cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : ,….. 1:2:4(1cement:2coarse sand (zone- III):4 graded stone aggregate 40 mm nominal size) |
| 26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 27 | Finishing wall with textured exterior paint of required shade :New work (Two or more coats applied @3.28itrkg/10sqm )over and including priming coat of exterior primer applied @2.20kg/10sqm |
| 28 | Distempering with 1st quality acrylic distemper (ready mixed) having VOCcontent less than 50 gram/litre, of approved manufacturer and of requiredshade and colour all complete to achieve even shade and colour :13.41.1 New work (two or more coats) over and including waterthinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 29 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm) |
| 30 | Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I. |
| 31 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated |
| 32 | Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 33 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 34 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 35 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 36 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparentor dyed to required shade according toIS: 1868, Minimum anodic coating of gradeAC 15) |
| 37 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.0 mm thickness (weight not less than 10kg/sqm) |
| 38 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. |
| 39 | Frame for 1/2 panel window:- |
| 40 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 41 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based)conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)Size of Tile 1000x1000 mm |
| 42 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 |
| 43 | Providing and laying rectified Glazed Ceramic floor tiles of size 300X 300 mm |
| 44 | Supplying and fixing MS Grill made of 20X6mm MS flat/square bar as per approved design and drawing properly fabricated with joints continues fillet welded and finised smooth carriage of to work site, hoisteing as per builing specification as per direction of E/I |
| 45 | Provinding and fixing in poisition collapsible steel shutter with vertical channels 20x10x2mm and braced with flat iron diagonal 20x5mm size with top and bottom rail T iron 40x40x6mm with 40mm dia steel pulleys, complete with bolts nuts locking arrangement stopper, handles, including applying prime coat of approved steel primer. |
| 46 | Providing one coat of synthetic enamel paint of approved shade and make over steel surface thorougly -do- |
| 47 | Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single care cable in surface/ recessed PVC condult with modular switch modular plate suitable Gl box etc as required. |
| 48 | Wiring for light/ power plug with 2x4 sq. mm FR PVC Insulated copper conductor single core cable in surface/ recessed PVC condult alongwith 1 No 4 sq. mm FR PVC Insulated copper conductor single core cable for leop earthing as required. |
| 49 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit as required |
| 50 | 2xx2.5 sq mm 1x2.5 sq mm earth wire |
| 51 | Supplying and foing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 52 | 32mm dia |
| 53 | Supplying and foang following moduler switch socket on the existing madular plate & switch box including connections but excluding modular plate etc as required. |
| 54 | 15/16 amp one way switch |
| 55 | 5/6 amp 3 pin socket outlet |
| 56 | 15/16 amp 5 pin socket outlet |
| 57 | Supplying and foang stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 58 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 59 | Supplying and frương 2 pin 5 Amp Ceiling rose on the existing junction box wooden block Including connection etc as required. |
| 60 | Installation testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tute etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted copper conductor single core cable and earthing etc. as required. |
| 61 | Installation testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. |
| 62 | Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan making good the damage connection testing commissioning etc. as required. |
| 63 | Supplying and foang following ways horizontal type three pole and neutral sheet steel MCB distribution board 415 volts on surface/recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 64 | Supplying and fixing 6 Amp to 32 Amp rating 240 volts 10 KA \\"C\\" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. |
| 65 | 6/32 Amp TPN |
| 66 | 40 Amp TPN |
| 67 | Supplying and fibing of following rating double pole (Single pole & neutral) 240 volts resudual current circuit breaker (RCCB) having a sensivity current 30 miliampere in the existing MCB DB complete with connections testing & commissioning etc as required. |
| 68 | 10/12 W LED Tube Light |
| 69 | 20/22 W LED Tube Light |
| 70 | SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts 50 Hz. AC supply complete with motor louvers/shutters etc. complete as required. Make-Usha/Crompton / Havells. |
| 71 | Supply Installation Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2018 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz Single phase supply etc. complete as required. Make - Usha/Crompton / Havells. |
| 72 | 10 litre. Low level cistern |
| 73 | Supplying fitting and foơng 40mm high vitreous white glazed earthen E.W.C. with 'p' trap of pery hindustan or any other approved 1.S.S. make including supplying and fixing 15 litres C.L mosquito proof low down flushing cistern of approved make with complete fittings with C.l.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commandericuckoo or other 1.3.3. make with hinges or screws etc, painting pipe and cistem etc, with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/L |
| 74 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approvad make supported on painted C.l. or R.S. brackets 32mm C.Lbrass waste, 15 mm dia C.L. body brass spindle stop cock of approved quality of weight not less than 350grams 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of EL |
| 75 | Providing and foxing white vitreous china laboratory sink with Cl brackets, C.P brass chain with rubber plug 40 mm C.P brass waste and 40 mm CP brass trap with necessary C.P brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required: |
| 76 | Providing and fixing white vitreous china flat back or wall comer type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 77 | 32mm Dia |
| 78 | Providing and foing PTMT liquid soap container 109 mm wide 125 mm high and 112 mm distance from well of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less then 105 gms. |
| 79 | Providing & foxing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimurn distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms |
| 80 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 |
| 81 | 15mm nominal bore |
| 82 | 15 mm nominal bore |
| 83 | with 100 mm dia. Pipe |
| 84 | 15 mm nominal bore |
| 85 | Providing & fixing rain weter \\"Khurras' size 450x450 mm required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen, Including Heavy duty CMS grating as per drawing complete as required. |
| 86 | Supplying ficting and fixing H.C.L. pipes with sar of approved make confirming to LS.1. 1729 including supplying nails and bobins short pieces, cutting loose collars, lead and yam for making lead caulked joints, cutting pipes to size including earth work or scaffolding where necessary etc., all complete as par specification and direction of P |
| 87 | (b) 75 mm dla |
| 88 | (c) 50 mm dia |
| 89 | A) H.C.L single junction with door but without ear except socket (I) 100 mm dia (wt. 10.5 Kg. app.) |
| 90 | (B) H.G.I. Heal Rest bend (I) 100 mm dia (wt. 5.5 Kg. app.) |
| 91 | Cutting drain width wise above G.L. for laying H.C. pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction |
| 92 | Making holes in walls for laying H.C.L pipes and restoring the same after pipe laying as per specification and direction of E/1. (a) 125mm dia |
| 93 | Supplying materials and labour for painting the exposed H.C. pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/1. (a) 50 mm dia |
| 94 | (a) 100 mm dia |
| 95 | Providing Fixing testing and commissioning of UPVC pipe SWR type \\"B\\" conforms to IS: 13592-1992 with all fittings such as bends, tees, elbow, Y offset cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS: 13592-1992 type 'B'. The fitting dimension conforming to IS: 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint 110 mm (OD) SWR Pipe |
| 96 | Providing and fuong G.L. pipes complete with Gl fittings and clamps including cutting and making good the walls etc. (Exposed on well Terrace) |
| 97 | Providing and foxing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including foxing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc. |
| 98 | 20 mm nominal outer dia pipes |
| 99 | 25 mm nominal outer dia pipes |
| 100 | Providing and fixing of gun metal gate valve with Cl wheel of approved quality (screwed ends) 18,17.2 32 mm dia, nominal bore |
| 101 | Painting Gil pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality 18.40.3 25 mm dia, nominal bore |
| 102 | Providing and fixing G.L. union in G.L. pipe including cutting and threading the pipe and making long screws etc, complete, 18.46.4 32mm nominal bore |
| 103 | Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design, |
| 104 | Constructing masonry Chamber 60x45x50 cm, inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (Inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement: 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortor 1:3 (1 cement 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design, |
| 105 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but withoud fittings and the hese support for tank |
| 106 | (a) 4.5 kg carbon dioxide extinguisher IS marked with high pressure discharge tube hom control valve CCE approved cylinder |
| 107 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. |
| 108 | (b) From 51.0 M to125.00 M |
| 109 | (c) From126.0 M to200.00 M |
| 110 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 111 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp |
| 112 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 113 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. |
| 114 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 115 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 116 | (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc |
| 117 | Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr |
| 118 | Provrding and filling of Groove between 50 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent |
| 119 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement laster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 120 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :21.1.1 For fixed portion21.1.1.2 Powder coated aluminium (minimumthickness of powder coating 50 micron) @ 1.10 KG/SFT. |
| 121 | 21.3 Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item):21.3.1 With float glass panes of 4.0 mm thickness (weight notless than 10kg/sqm) |
| 122 | 9.84 Providing and fixing aluminium extruded section body tubular typeuniversal hydraulic door closer (having brand logo with ISi, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door widthfrom 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc.complete |
| 123 | 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.100.1 125 mm |
| 124 | Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessary screwsetc. complete.9.101.2 Twin rubber stopper |
| 125 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (16.91.2) |
| 126 | Providing P.C.C.M -200 with normal mix of (1:1.5:3) in foundation with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening,, shuttering, mixing cement concrete in mixer and placing in position,vibrating ,striking, curing , taxes and royalty all complete as per building specification and direction of Engineer Incharge.(5.3.1.1) |
| 127 | Earthing with GI earth pipe 4.5 m long \times 40mm dia. including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. |
| 128 | Earthing with copper earth plate 600\text{mm} \times 600\text{mm} \times 3\text{mm} thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required. |
| 129 | Extra for using charcoal and salt for GI/Copper Plate earth electrode as required. |
| 130 | Providing and fixing 8 SWG copper wire at 0.50\text{ metre} below ground level for conductor earth electrode, including soldering etc. as required |
| 131 | Photography And sign Board |
| 132 | Sign Board with Lighting |
| 133 | Sand (lead upto 10 km) |
| 134 | Stone chips (20km) |
| 135 | Brick (lead upto 18 km) |
| 136 | ADD 18% GST |
| 137 | ADD 1% L.C Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender