Tender For Procurement Of Pca Pump – 02 Nos. For The Department Of Anesthesia & Critical Care At Aiims, Raebareli.
Tender Overview
Project Description
Tender For Procurement Of Pca Pump – 02 Nos. For The Department Of Anesthesia & Critical Care At Aiims, Raebareli. 1 Flow Rate Range Should Be 0.1M1/Hr To 1200 Muh With Accuracy Of T 1% On Mechanism 2 Should Work On The Folowing Syringe Capacities 5, 70, 20, 30135,50/60 Cc And Should Be Compatible With Min Lootypes Of Syringe 3 Should Have Syringe Protective Cover With Key Locking System 4 Lnfusion Modes To Be Present: Pca Bolus, Continous Rate, Pca Bolus+Continous & Pca Bolus+Variable Rate Mode 5 Dose Unit Supported: Nglh, Ng/Kg/Min, Ng/Kg/H, Pe/Min, Pg/H, Pe/Ke/Min, Vclke/H, Melmin, Ms/H, Me/24H, Me/Kg/Min, Me/Ke/H, Me/Kg/24H, Msl M2 Lh, Ms/ M2 /24H, S/H, Gl Vel Min, E/Ke/6, E/Kg/24H, Mmol /H, Mmol/Ke/H, Mmol/Kg/24H, Mu/Min, Mu/Kglmin, Mu/Ke/H, U/Min, U/H, U/Kg/Min, Ulke/H, Kcallh, Kcal/A4H, Kcal/Kg/H, Meq/Min, Meq/H, Meq/Kg/Min, Meq/Kc/H. 5 3 Modes Priming Is Required (Mandatory, Not Mandatory, Or Advised) With Max Flow Rate: 1200 Ml/Hr. Should Have Direct Bolus Option With Flow Rate 50Ml/Hr To 1200Mi/Hr With Increment Of 50Ml/Hr Along With Programable Bolus With Settable Dose Or Volume/Time 7 I Should Have Clinical Bolus Facility During Start Up As Loadin8 Dose Also During Pca Cycle With A Password. 9 Should Have Industion Dose Facility With Setting Of Dose / Time: 0.1 - 99.9 Units / 1 Second - 24 Hours Rate Auto-Calculation 10 Should Have Kvo Option Ranging From 0.1To 5Ml/Hr 11 Should Have Drug Library Of Minimum 3500 Drugs Categorized In User Defined 19 Categories With Facility To Set All Infusion Parameters Through Vigilant DrusLibrary L2 Fast Start Option Is Mandatory With Pause Option Programmable From Lmin To 24Hrs 13 Should Have Pca History Followup From Th To 24H Including Data Like Total Dose Given, Pca Bolus Attempted, Pca Bolus Give, Clinical Bolus & Background Dose. L4 The Night Mode Programmed Manually Or Automatically In A Variable Time Range Is Must To Decrease The Brightness Of The Screen. 15 Should Have Variable And 3 Pre-Set Levels Pressure Mode Is Must. Range From 50 To 900 Mmhg. (25 Mmhg Increment From 50 To 250 Mmhg / 50 Mmhg Increment From 250 To 900 Mmhg). Can Be Enables / Disabled And Adjusted. 16 The Dynamic Pressure System With Maximum And Minumum Threshold Setting Is Mandatory. L7 Anti-Bolus System Is Required 18 The Device Should Have Syringe Barrel Clasp Check, Plunger Head Detection, Anti-Siphon System Check, Flange Detection. 19 The Device Should Have The Folowing Alarm Occlusion Pressure Pre-Alarm, Occlusion Pressure Alarm, End Of Infusion Pre-Alarm, End Of Infusion Alarm, Volume Limit Pre-Alarm, Volume Limit Alarm, Keypad Manual Locking Or Keypadlock, Hard And Soft Flow Rate Limits, Start Infusion At Pause End, Disengaged Driving Mechanism Alarm, Low Battery Pre-Alarm, Discharged Battery Alarm, Battery Capacity Display In Hours And Minutes, Unconfirmed Programming, Technical Malfunction Alarm (Auto-Test, Rotation), Drive System Advance Check, Watchdog Check, Communication Connection Failure, Plug-Head Disengagement, Auto-Lock/Lock Code (On Keypad). 20 Should Have Patient Handset Control Indicators Like Handset Not Connected, Handset Button Continously Pressed & Patient Bolus Refused 21 The Device Should Have Push Guard For Syringe Protection.
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Offline submission at the designated office.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender