Rural Development Local Bodies Closing in 18 days TDR #58223675

Tender For Construction Of Community Library At Nehru Park, Op Jindal Park And Kundi Talab In Municipal-Corporation, Yamunanagar -Jagadhri.

Issued by Local Bodies · Yamunanagar, Haryana
Tender Value
5.20 Crore
Estimated cost
Bid Submission
16 Nov 2026
18 days left
EMD
10.40 Lakhs
Bank guarantee accepted
Document Fee
25000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Yamunanagar → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Community Library At Nehru Park, Op Jindal Park And Kundi Talab In Municipal-Corporation, Yamunanagar -Jagadhri.

BOQ

Name of Work:- Construction of Community Library at Nehru Park, OP Jindal Park and Kundi talab in Municipal–Corporation, Yamunanagar -Jagadhri.
Sl. No. Item Description
1Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
2Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.
3INTELLIGENT FIRE ALARM SYSTEM : Micro processor based. Intelligent Addressable Main Fire alarm panel, Central Processing Unit ,with the following loop module and with each loop capacity of 120 detector per loop with total of 240 detectors and devices with loop length up to 2 kmtr, network communication card, minimum 320 character graphics, LCD display with touch screen or other keypad and 1000 event history logs in the non volatile memory (EEPROM) power supply unit at 230 plus 5 % V, 48 Hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout logs and facility to have integration with analog voice evacuation system( which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel should be compatible for integration with IBMS system with open protocol Bacnet/IP , complete as per specs and as required for following loops.
4Supplying, installation, testing and commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
5Supplying, installation, testing and commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
6Kirloskar make Waste Water Disposer Submersible Pump in SS body Model 1000SW 2880 RPM Single phase 1.25HP/1.0KW delivery pipe 40MM with AUTO CUT-OFF Arrangement
7Providing and fixing white finishes ABS Hand Dryer
8Providing and fixing wall mounted SS Paper towel dispenser of capacity 400 to 600.
9Providing and Fixing 600 mm long Hand rail (Grab bar) for Toilets with Stainless Steel Screws on wooden cleats / expandable fastners complete as per instructions of the engineer-in-charge
10Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 10 Kg/cm2 etc. complete in all respect. (25mm nominal bore)
11Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 10 Kg/cm2 etc. complete in all respect. (32mm nominal bore)
12Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 10 Kg/cm2 etc. complete in all respect. (40mm nominal bore)
13Providing and fixing 25mm dia. G.I. air release valve, single acting including the cost of all pipes and fittings as per standard design and site conditions complete in all respects.
14Providing and fixing UV stabilized UPVC soil and wast UPVC PIPES HSN CODE : 3917 SCH 40 / SCH 80 Pipes Conform to ASTM D 1785 (32 mm dia )
15Providing and fixing UV stabilized UPVC soil and wast UPVC PIPES HSN CODE : 3917 SCH 40 / SCH 80 Pipes Conform to ASTM D 1785 (40 mm dia )
16Providing and fixing UV stabilized UPVC soil and wast UPVC PIPES HSN CODE : 3917 SCH 40 / SCH 80 Pipes Conform to ASTM D 1785 (50 mm dia)
17Providing and fixing UV stabilized UPVC soil and wast SWR type B pipes as per IS 13592 (equivalent to 6Kg/sq.cm) with one end plain and other end socketed with jointing as per IS code, fittings such as tees, bends, doors etc. and provided with solvant cement including clamps/structural steel supports as required/directed at site including cutting and making good the walls, floors, RCC work etc, cutting chases and filling the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) or cement mortar 1:4 (1 cement :4 coarse sand) as required. Where required holes in slabs shall be made by the Contractor and after installation the same shall be resealed and fire barriers shall be provided as necessary. The piping shall be installed, supported and all joints made strictly as per the manufacturers recommendations. (For soil/waste/rain pipes at ceiling level inside the building) (75 mm dia)
18Providing and fixing UV stabilized UPVC soil and wast SWR type B pipes as per IS 13592 (equivalent to 6Kg/sq.cm) with one end plain and other end socketed with jointing as per IS code, fittings such as tees, bends, doors etc. and provided with solvant cement including clamps/structural steel supports as required/directed at site including cutting and making good the walls, floors, RCC work etc, cutting chases and filling the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) or cement mortar 1:4 (1 cement :4 coarse sand) as required. Where required holes in slabs shall be made by the Contractor and after installation the same shall be resealed and fire barriers shall be provided as necessary. The piping shall be installed, supported and all joints made strictly as per the manufacturers recommendations. (For soil/waste/rain pipes at ceiling level inside the building) (110 mm dia)
19Providing and fixing UV stabilized UPVC soil and wast SWR type B pipes as per IS 13592 (equivalent to 6Kg/sq.cm) with one end plain and other end socketed with jointing as per IS code, fittings such as tees, bends, doors etc. and provided with solvant cement including clamps/structural steel supports as required/directed at site including cutting and making good the walls, floors, RCC work etc, cutting chases and filling the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) or cement mortar 1:4 (1 cement :4 coarse sand) as required. Where required holes in slabs shall be made by the Contractor and after installation the same shall be resealed and fire barriers shall be provided as necessary. The piping shall be installed, supported and all joints made strictly as per the manufacturers recommendations. (For soil/waste/rain pipes at ceiling level inside the building) (150 MM DIA)
20Providing and fixing of Hubless centrifugally cast (spun) iron epoxy coated inside and outside as per IS:15905 Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. (110 mm dia Pipe)
21Providing and fixing of Hubless centrifugally cast (spun) iron epoxy coated inside and outside as per IS:15905 Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. (150 mm dia Pipe)
22Providing and fixing to the inlet mouth of rain water pipe cast iron grating (450 X 450mm )
23Providing and fixing to the inlet mouth of rain water pipe cast iron grating (300 X 300mm )
24Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
25Supplying, installation, testing and commissioning of fault isolator complete with base as required
26Supplying, installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required.
27Supplying, installation, testing and commissioning of addressable fire control module complete as required.
28Supplying, installation, testing and commissioning of addressable manual call point complete as required.
29Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required.
30Supplying, installation, testing and commissioning of addressable strobe cum flasher complete as required.
31Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required.
32Supply ,recieving, storing, handling, double handling, trasnport to exact location, hoisting to required level, ,assembling, erecting, testing and commissioning luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc.as per specifications and as per catalogue number giving below. 20W LED Slim profile surface mounted downlight
33Supply ,receiving, storing, handling, double handling, transport to exact location, hoisting to required level, ,assembling, erecting, testing and commissioning luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc.as per specifications and as per catalogue number giving below. 15W LED low-height LED downlighter (Corridor plus Cabins)
34Supply ,receiving, storing, handling, double handling, transport to exact location, hoisting to required level, ,assembling, erecting, testing and commissioning luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc.as per specifications and as per catalogue number giving below.30W LED Recessed mounted (2X2 Light Fixtures)
35Supply ,receiving, storing, handling, double handling, transport to exact location, hoisting to required level, ,assembling, erecting, testing and commissioning luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc.as per specifications and as per catalogue number giving below. 26W LED Suspended type fixtures of 50mm width channel light
36Design manufacture, supply installation testing and commissioning of following Inverter system for a constant secondary voltage of 240 volts at 50 Hz, single phase, batteries backup of minimum 90 minutes duration including, SMF batteries, battery chargers, rectifiers, transformers, controls, protection and instruments etc. complete as required. Cost to include battery stand/rack, interconnecting cables etc. 3000VA
37Supply and installation of Reception table L-Shape:-Made of all body 18mm thick plpb board. Table top thick 25mm, 2mm edgebanded Pvc Tape with approved laminate shade. Size:-1800x900x750mm.
38Supply and installation of library Assistant Table with side and back unit:-25mm thick top, 2mm edgeband with approved laminate shade with plpb board and metal understructure 50x50mm straight leg, and metal beam 50x25mm including wooden modesty cable tray with flapper box-400mm.Size:-1200x800x750mm.
39Supply and installation of study Table with Partitions:-25mm thick top 2mm edgebanded pvc tape with approved lamiante shade with Plp board and metal understructure 50x50mm straight metal leg and metal beam 50x25mm with powder coating including cable tray. Size:-1200x600x750mm.
40Supply and installation of E-Library Tables with Side units:-25mm thick top 2mm edgebanded pvc tape with approved laminate shade with Plp board and metal understructure 50x50mm straight metal leg and metal beam 50x25mm with powder coating including cable tray. Size:-1200x600x750mm.
41Supply and installation of Full height Wooden Storages with glass:-25mm thick top made of all body and shelf 18 mm thick Plp board edge band with approved shade. Size:-1800x450x750mm.
42Supply, installation, testing and commissioning of 2MP Dome - 1/2.9` CMOS, ICR, 1920x1080:30fps, 265/H.264/MJPEG, Triple streams, DC12V and PoE, Min Illumination 0.001 Lux / F1.6, 0 Lux (IR LED ON) , Shutter Speed 1/2 to 1/10,000 sec , DWDR, , Fixed lens (2.8mm, 4mm), IR range: up to 25m, Operating Temperature -25? ~ 50?, Weather-proof IP66, included Gang box with I/O and requried all accessoires.
43Supply, installation, testing and commissioning of 32” CCTV colour LED screen including all accessories complete as required. (For Viewing 16 Cameras)
44Supply,installation,testing and commissioning of Managed switches - 24 Port PoE/PoE 10/100 Mbps Switch with 2 Fiber uplinks including Fibre SFP module for LAN base feature set with support to integration with CCTV with all related hardware like rack (L2 Switch)
45Supply, installation, testing and commissioning of CAT 6 24 port Patch Panel Loaded
46Supply, installation, testing and commissioning of CAT 6 Patch Cord 1mtr For Rack End Side, camera Side.
47VRV/VRF outdoor unit (ODU) R-410A /Eco friendly refrigerant ( with zero ODP ) complete with dual circuit/dual PCB circuit, hermetic SCROLL compressor, heat exchanger, axial flow quiet operation condenser fan , microprocessor based control panel, modular type construction, safety devices, controls, fault alarm indications, memory storage, hydrophilic coated condenser coil with copper tube and copper header, condenser guard, soft starter, fan guard, CRC/GI POWDER COATED outer casing, vibration isolators, static pressure of ODU fan shall be minimum 10 mm for top discharge and 8 mm for side discharge , Rubber pad etc as per the specification . All necessary fittings like GI nuts , bolts , fasteners etc shall include in the rates .Minimum one compressor should be inverter controlled in a single machine . The VRV/VRF systems should be for cooling mode only. The capacity shall be as indicated below .Cooling capacity at ARI conditions54 HP ( 3 phase 415 volts ±10% V,50 ± 5% Hz) High COP,top discharge, noise level shall be 80 dBA @ 1 meter distance
484 Way Cass. type Indoor units suitable to ODU refrigerant complete with pre filter,evaporator, fan, electronic expansion valve , drain pan along with inbuilt drain pump . All units shall be suitable for 240 ± 10% volts, 50 Hz ± 5%, single phase power supply 3.20 TR Indoor unit
494.00 TR Indoor unit4 Way Cass. type Indoor units suitable to ODU refrigerant complete with pre filter,evaporator, fan, electronic expansion valve , drain pan along with inbuilt drain pump . All units shall be suitable for 240 ± 10% volts, 50 Hz ± 5%, single phase power supply
50Wireless Remote ControlComplete charge of Refrigerant for installation ,commissioning and handover.[IF REQUIRE]
51Inter-connected copper refrigerating piping between VRF Indoor and Outdoor with Pre formed NITRIL RUBBER INSULATION (Thickness 13 / 19mm) as per drawing and Specifications41.3 mm Copper pipe with 19 mm thick insulation
5234.9 mm Copper pipe with 19 mm thick insulationInter-connected copper refrigerating piping between VRF Indoor and Outdoor with Pre formed NITRIL RUBBER INSULATION (Thickness 13 / 19mm) as per drawing and Specifications
5322.2 mm Copper pipe with 19 mm thick insulationInter-connected copper refrigerating piping between VRF Indoor and Outdoor with Pre formed NITRIL RUBBER INSULATION (Thickness 13 / 19mm) as per drawing and Specifications
5415.9 mm Copper pipe with 13 mm thick insulationInter-connected copper refrigerating piping between VRF Indoor and Outdoor with Pre formed NITRIL RUBBER INSULATION (Thickness 13 / 19mm) as per drawing and Specifications
55Supply, installation of control cum transmission wiring of 2C x 1.5 Sqmm copper in suitable PVC conduits for intercinnection between IDUs and Odus and IDUs and Remotes.
5628.6 mm Copper pipe with 19mm thick insulationInter-connected copper refrigerating piping between VRF Indoor and Outdoor with Pre formed NITRIL RUBBER INSULATION (Thickness 13 / 19mm) as per drawing and Specifications
57Providing and fixing 25mm x 5mm GI strip on surface or in rececess for earth connections etc. complete as required.
5875x50 mm W x 1.6 mm thick 70% perforated typeSupply and installation of following size of ladder/perforated GI cable tray, including horizontal and vertical bends reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders including painted etc.as required.
59300x50 mm W x 1.6 mm thick 70% perforated typeSupply and installation of following size of ladder/perforated GI cable tray, including horizontal and vertical bends reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders including painted etc.as required.
60150x50 mm W x 1.6 mm thick 70% perforated typeSupply and installation of following size of ladder/perforated GI cable tray, including horizontal and vertical bends reducers, tees, cross members
61100x50 mm W x 1.6 mm thick 70% perforated typeSupply and installation of following size of ladder/perforated GI cable tray, including horizontal and vertical bends reducers, tees, cross members
626CX1.5 Sqmm-Copper Shilded Cable - FRLSSupply, Laying, installation, Termination, testing and commissioning of complete cable work using PVC insulated PVC sheathed copper control cables
63Supply, Laying and Termination with brass double compression glands and aluminium lugs, testing and commissioning of complete cable work using XLPE insulated PVC sheathed steel tape3 core x 10 Sqmm -Cu. armoured cable
643 core x 6 Sqmm -Cu. armoured cableSupply, Laying and Termination with brass double compression glands and aluminium lugs, testing and commissioning of complete cable work using XLPE insulated PVC sheathed steel tape
653 core x 4 Sqmm -Cu. armoured cableSupply, Laying and Termination with brass double compression glands and aluminium lugs, testing and commissioning of complete cable work using XLPE insulated PVC sheathed steel tape/ wire armoured underground aluminium/
663 core x 2.5 Sqmm -Cu. armoured cableSupply, Laying and Termination with brass double compression glands and aluminium lugs, testing and commissioning of complete cable work using XLPE insulated PVC sheathed steel tape
67Supply, Laying and Termination with brass double compression glands and aluminium lugs, testing and commissioning of complete cable work using XLPE insulated PVC sheathed steel tape4 core x 10 Sqmm -Cu. armoured cable
68Refnet joints to connect copper piping of the indoor unit to the main circuit line complete with nitrile rubber insulation Class O
69Microtek UPS (Uninterruptible Power Supply) 750 VA
7050 mm diaUPVC pipes SCH 40 for drain pipes with 9 mm thick closed cell nitrile rubber insulation of density shall be more than 40 kg/m3
71UPVC pipes SCH 40 for drain pipes with 9 mm thick closed cell nitrile rubber insulation of density shall be more than 40 kg/m340 mm dia
72HP Laserjet Tank MFP 1005 W printer-Multifuntion with WiFi Connectivity.
73UPVC pipes SCH 40 for drain pipes with 9 mm thick closed cell nitrile rubber insulation of density shall be more than 40 kg/m332 mm dia
7419.1 mm Copper pipe with 19 mm thick insulationInter-connected copper refrigerating piping between VRF Indoor and Outdoor
7512.7 mm Copper pipe with 13 mm thick insulationInter-connected copper refrigerating piping between VRF Indoor and Outdoor
76Inter-connected copper refrigerating piping between VRF Indoor and Outdoor9.5 mm Copper pipe with 13 mm thick insulation
77Complete charge of Refrigerant for installation ,commissioning and handoverWireless Remote Control
78Providing and fixing 6 SWG dia. GI wire on surface or in rececess for loop earthing
79PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES (6 Sq mm 4 core (Arm.) (24.11.12)
80PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES (10 Sq mm 2core (Arm.) 24.11.14
81Supply and installation of Desktop : (Dell AIO 5430, Intel core I5-1334U 8GB, 512GB SSD, 23.8` FHD, Wireless Keyboard and Mouse, BT, Wifi, Window11 , MS Office (Three Year Warranty)
82Godrej Interio Revolving Chair with Knee tilt synchronic mechanism.(Supply and Installation of Library Assistant / Librarian / Reception Chair)
83Godrej Interio Revolving chair with centre tilt mechanism (Godrej Interio APO Project Mesh Revolving Mid Back) { Study Chair for E- Library}
84Godrej Interio Cantilever Office Chair Non-Revolving and non- tilting chair with armrest (Godrej Interio APO Project Mesh Visitor Chair) Library Study chair
85[10.30.2]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 2. Medium shade pigment using 50% white cement 50% Grey cement [Through Rate]
86[10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick [Through Rate]
87[10.44.1]Providing and fixing of marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : 1. Makrana white second quality [Through Rate]
88[10.49.1]Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 1. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
89[10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]
90[10.67.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm [Through Rate]
91[10.71.2]Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 2. Size of Tile 600x600 mm [Through Rate]
92[11.65.1]Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work [Through Rate]
93[11.75.2]Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats [Through Rate]
94[11.8.2]12 mm cement plaster of mix : 2. 1:6 (1 cement: 6 coarse sand) [Through Rate]
95[11.9.2]15 mm cement plaster on rough side of single or half brick wall of mix: 2. 1:6 (1 cement: 6 coarse sand) [Through Rate]
96[11.94.1]Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm [Through Rate]
97[12.117.1]Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 Nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 1. Extruded section profile size 48x40 mm [Through Rate]
98[12.120.2]Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC `C` channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail and bottom rail, panelling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles and rails with 7 mm (5 mm plus 2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the `C` Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer`s specification and drawing. 2. 30 mm thick pre laminated PVC door shutters [Through Rate]
99[12.130.3]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 3. Double glass glazing comprising of 6 mm thick toughened clear glass + 12mm air gap + 5mm annealed clear glass. [Through Rate]
100[12.136.1]Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) crescent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1. Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm up to 5.00 sqm) [Through Rate]
101[12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate]
102[13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes [Through Rate]
103[2.B1328] B1328. Health Faucet [Rate]
104[2.EL281] EL281. 100mm dia, [Rate]
105[2.EL282] EL282. 80mm dia, [Rate]
106[20.62.1]Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. 1. 200 mm i/d [Through Rate]
107[20.62.2]Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. 2. 250 mm i/d [Through Rate]
108[21.100.2]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 2. 100 mm dia pipe [Through Rate]
109[21.100.4]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 4. 150 mm dia pipe [Through Rate]
110[21.87.1.1]Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as Specified in item No. Item 21.48) complete to the requirement of the Engineer in-charge 1.1. Single road gully chamber - Size: 610mm x 457mm x 800mm [Through Rate]
111[21.94.3]Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 3. 200mm i/d [Through Rate]
112[22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore [Through Rate]
113[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate]
114[22.117]Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. [Through Rate]
115[22.118]Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. [Through Rate]
116[22.14.2.1]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.1. Flexible pipe 32 mm dia [Through Rate]
117[22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate]
118[22.166.2.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 2.1. 150 x 100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
119[22.179.2.1]Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 2.1. Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
120[22.180.2.1]Extra for depth beyond 45 cm of brick masonry chamber : 2.1. For 500x700 mm size With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
121[22.186.1]Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 1. 80 mm dia nominal bore [Through Rate]
122[22.190.1.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 1.1. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
123[22.190.3.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 3.1. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
124[22.191.1.1]Extra for depth for manholes : 1.1. Size 90x80 cm With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
125[22.198.1]Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1. With 20x20 mm square bar [Through Rate]
126[22.2.1]Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 1. White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer [Through Rate]
127[22.206.1]Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
128[22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate]
129[22.212.1.2]Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. 1.2. C.P Brass Two Way [Through Rate]
130[22.23.1]Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 1. W.C. pan with ISI marked white solid plastic seat and lid [Through Rate]
131[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate]
132[22.6.1]Providing and fixing white vitreous chinaware laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 1. Size 450x300x150 mm [Through Rate]
133[22.80.1.3]Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1.3. 100 mm inlet and 100 mm outlet Hub less centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 [Through Rate]
134[22.80.2.3]Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 2.3. 100 mm inlet and 75 mm outlet Hub less centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 [Through Rate]
135[22.85.1]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes [Through Rate]
136[22.85.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate]
137[22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]
138[22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate]
139[22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes [Through Rate]
140[22.85.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 6. 50 mm nominal outer dia Pipes [Through Rate]
141[23.1.6.1]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.1. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
142[23.1.6.6]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.6. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
143[23.2.1.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B [Through Rate]
144[23.2.2.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 2.2. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B [Through Rate]
145[23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) [Through Rate]
146[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
147[23.22.6.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.1. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 25 A [Through Rate]
148[23.22.6.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.2. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 A [Through Rate]
149[23.22.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 7. Supply and erection of blanking sheet in existing distribution board. [Through Rate]
150[23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm [Through Rate]
151[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
152[23.3.5.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B [Through Rate]
153[23.6.6.1]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. [Through Rate]
154[23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. [Through Rate]
155[23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate]
156[23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate]
157[23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules [Through Rate]
158[23.8.3.1]FITTING AND ACCESSORIES 3.1. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below 75 mm x 75 mm x 60 mm deep M.S. box [Through Rate]
159[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
160[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
161[24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required. [Through Rate]
162[24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate]
163[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]
164[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
165[24.11.10]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 10. 6 Sq mm 3 core (Arm.) [Through Rate]
166[24.11.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 18. 10 Sq mm 4 core (Arm.) [Through Rate]
167[24.11.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 38. 35 Sq mm 3.5 core (Arm.) [Through Rate]
168[24.11.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 54. 70 Sq mm 3.5 core (Arm.) [Through Rate]
169[24.11.6]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 6. 4 Sq mm 4core (Arm.) [Through Rate]
170[24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core [Through Rate]
171[24.2.9.4]LT CABLE 9.4. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 10 to 16 sqmm Cable 3 to 4 Core [Through Rate]
172[25.3.8]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 8. 65mm dia. [Through Rate]
173[26.19.1]Maintenance of shrub for one year including weeding, hoeing, plant protection, watering from Deptt. source, application of 10 ml chlorpyriphos four times in a year , 0.0289cum FYM each, 20 gm urea and 20 gm DAP twice, replacement of casualty etc. with same species and same age of plant 1. Individual shrubs [Through Rate]
174[26.20]Supply and Planting rare and specimen tree plants in already prepared pits (Ficus starlight 150 cm height , Terminalia 210 cm height, menatalis , Michelia champaca hybrid more than 180 cm height, Cyprus (Golden juniperous ) more than 180 cm height, topiary of 10 to 12 no. well trimmed bolls of more than 30cm size of Ficus nuda, Ficus retusa, Ficus long island , Ficus panda more than 180 cm height, Golden bottle brush , casurina equistefolia , Bottle palm with stem circumference at base more than 40cm ,Washingtonia palm of healthy clear stem height below leaf more Thant 90 cm ) including , fertilizer and insecticides chlorpyriphos 20 ml per pit, planting of 180cm to 210cm tall sapling in position and flooding with water .specie of plant will be decided by engineer in charge. [Through Rate]
175[26.22.1]Planting seasonal flower in beds 1. Supply and planting flower beds including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10 ml per sqm , planting of F1 hybrid flower saplings to be supplied in tray pots / thumb pots at 20 cm distance from plant to plant and row to row minimum 25 no . plants per sqm [Through Rate]
176[26.23]Maintenance of flower beds for one year including , application of FYM 0.050 cum , insecticide 10 ml, fertilizer 50 gm ,per sqm , planting F1 Hybrid flower seedlings to be supplied in Plastic tray pots/thumb pots in winter, summer and rainy season @ 20cm apart row to row and plant to plant, 25 no. plants per sqm each time each season stacking with Kaanas and including all horticultural practices. [Through Rate]
177[26.24]Supply and planting bulbous flower of football lily, amaryllis lily , Lilium, gladiolus, Cladium of hybrid colour vise beds including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10 ml per sqm , planting of bold size flower bulbs of improved cultivars to be supplied and planted at 23 cm distance from plant to plant and row to row minimum 18 no . bulbs per sqm [Through Rate]
178[26.25]Maintenance of bulbous flower beds for one year including , application twice of FYM 0.050 cum , insecticide 10ml, fertilizer 20 gm per sqm , planting bulbous flower bulbs of football lily, amaryllis lily , Lilium, gladiolus, Cladium of hybrid colour vise to be supplied in Plastic tray pots/thumb pots in winter, summer season @ 30cm apart row to row and plant to plant, 18 no plants per sqm each time each season stacking with Kaanas and including all horticultural practices . [Through Rate]
179[26.26]Supply and planting ground cover plants including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10ml per sqm , planting of saplings at 23cm distance from plant to plant and row to row, minimum 19 no. plants per sqm [Through Rate]
180[26.27]`Maintenance of ground cover plants for one year including application of FYM 0.0508 cum , insecticide 10ml, fertilizer 20 gm ,per sqm, replacement of casualty with same specie of plant and all horticultural practices.` [Through Rate]
181[26.39.1]Providing Circular /square Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 6 mm nominal size), including required from work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows and height, all complete as per direction of Officer-in-Charge. Filling 2/3rd volume with mixture of good earth and screened manure in the ratio 2:1. 1. cement pots size 30cm x30cm [Through Rate]
182[26.39.5]Providing Circular /square Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 6 mm nominal size), including required from work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows and height, all complete as per direction of Officer-in-Charge. Filling 2/3rd volume with mixture of good earth and screened manure in the ratio 2:1. 5. cement pots size 60cm x 60 cm [Through Rate]
183[26.5]Making lawns with rough grassing including uprooting rank vegetation and weeds by digging area to a depth of 30 cm , removing all weeds and other growth with roots by forking repeatedly, ploughing and dragging with ‘swagha’ breaking of clods, removal of rubbish, dressing and supplying doob grass roots, and planting at 15 cm apart, including supplying and spreading of farm-yard manure at the rate of 0.18 cum per 100 sqm fertilizers etc [Through Rate]
184[28.17.1]Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 1. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. [Through Rate]
185[28.31]Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th and 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). [Through Rate]
186[31.14.3]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 3. 12mm dia (hole size 16mm.& hole depth up to 120 mm) 0 0 [Through Rate]
187[31.14.4]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 4. 16mm dia (hole size 20 mm dia & depth up to 200mm) 0 0 [Through Rate]
188[31.14.5]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 5. 20mm dia (hole size 24 mm dia & depth up to 240mm) 0 0 [Through Rate]
189[31.14.6]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 6. 25mm dia (hole size 30 mm dia & depth up to 300 mm) 0 0 [Through Rate]
190[32.70.1]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 1. Above 1 kWp and up to 10 Kwp [Through Rate]
191[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
192[4.16.1.1]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.1. All kind of soil Pipes, cables etc, not exceeding 80 mm dia . [Through Rate]
193[4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]
194[4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil [Through Rate]
195[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
196[5.1.2]Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : 2. In cement mortar [Through Rate]
197[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]
198[6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) [Through Rate]
199[6.13]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. [Through Rate]
200[6.24.1]Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level [Through Rate]
201[6.24.2]Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]
202[6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate]
203[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate]
204[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate]
205[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
206[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
207[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]
208[6.35.1]Steel reinforcement for R.C.C. work ready to use `cut and bend` rebars of approved make from factory/workshop to construction site including placing in position and binding all complete up to plinth level. 1. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate]
209[6.36.1]Steel reinforcement for R.C.C. work ready to use `cut and bend` rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 1. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate]
210[7.28.1]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 1. Cement mortar 1:3 (1 cement :3 coarse sand) [Through Rate]
211[7.47.2]Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor IV level in : 2. Cement mortar 1:6 (1 cement: 6 Coarse sand) [Through Rate]
212[9.16]Providing and fixing pressed clay tile (Mangalore tiles) of size 200mm x 125mm x 10mm on slopping roof top/ window projections with 12mm thick cement, coarse sand mortar 1:3 including cost of ridge wherever required as per approved design complete in all respect up to 4 storey or 15 Meter Height. [Through Rate]
213[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]
214[9.60]Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. [Through Rate] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58223675
AUTHORITY Local Bodies
TENDER VALUE 5.20 Crore
LAST DATE 16-11-2026
Authority
Authority Name Urban Local Bodies
Work Description Tender for Construction Of Community Library At Nehru Park, Op Jindal Park And Kundi Talab In Municipal-Corporation, Yamunanagar -Jagadhri.
Basic Detail
Tender No 2026CE9CA9CD 9A19 4BFC A9B1 3701E3489617288ULB
Bidding Type Tender
Location
City Yamunanagar
State Haryana
Key Dates
Publish Date 27 Oct 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 5.20 Crore
Tender Fee 25000
EMD 10.40 Lakhs
Exemption Available
Document List
73b56368-765d-431d-a3f2-ff51db8dda90.html
BOQ_636566.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

73b56368-765d-431d-a3f2-ff51db8dda90.html

xls

BOQ_636566.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender