Power Government Departments Closing in 2 days TDR #58223123

Tender For Construction Of 66Kv Transmission Line And 2 X 5 Mva, 66/11 Kv Substation At National Institute Of Technology (Nit), Khamdong Under Singtam Circle, Gangtok District, Sikkim.

Issued by Government Departments · sikkim, Sikkim
Tender Value
22.27 Crore
Estimated cost
Bid Submission
17 Nov 2026
2 days left
EMD
55.69 Lakhs
Bank guarantee accepted
Document Fee
5 Lakhs
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sikkim → Sikkim
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 66Kv Transmission Line And 2 X 5 Mva, 66/11 Kv Substation At National Institute Of Technology (Nit), Khamdong Under Singtam Circle, Gangtok District, Sikkim.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 07-Nov-2026 Technical bid Technical Bid 17-Nov-2026

BOQ

Name of Work:- CONSTRUCTION OF 66KV TRANSMISSION LINE AND 2 X 5 MVA, 66/11 KV SUBSTATION AT NATIONAL INSTITUTE OF TECHNOLOGY (NIT), KHAMDONG UNDER SINGTAM CIRCLE, GANGTOK DISTRICT, SIKKIM.
Sl. No. Item Description
1SECTION I: ELECTRICAL EQUIPMENT WORKS FOR CONSTRUCTION OF NEW 66KV SINGLE CIRCUIT TRANSMISSION TOWER.
2Fabrication, galvanizing & supply of various types of towers & tower parts, tower/leg extensions (complete) excluding step bolt, stubs and bolts & nuts but including hangers, D-Shackles, pack washers etc.-HT Steel for Large Angle Normal Towers (Superstructure).
3+6m extension
4+9m extension
5Fabrication, galvanizing & supply of stubs with cleats for various tower extension (complete) with pack washer excluding supply of bolts & nuts-HT Steel for Large Angle Normal Tower.
6Supply of Hexagonal Bolts & Nuts for Large Angle Tower including Step Bolt, Spring Washers etc
7Supply of Bolts & Nuts for Stubs including Spring Washers etc for Large Angle Tower.
8Stub setting template for use with +3m, +6m & +9m extension.
9Large Angle Tension tower.
10Danger Plate
11Number Plate
12Phase Plate
13Anti -Climbing Devices
14Earthing of Towers Safe Earthing Model T-39 Short Current 50KA rms for 1 sec (EHV application (80mm diameter x 3 mtrs Electrode (coppper bonded) and two bags backfill chemical compound)
15ACSR DOG conductor (6/4.72 sq.mm Al. 7/1.57 mm steel.)
16Conductor accessories :
17Repair Sleeve
18Vibration Damper
19Mid span compression joint
20Arching Horns
21Earth Wire (GI (7/10) SWG)
22Earth Wire accessories :
23Flexible Copper Bond for Earth Wire
24Tension Assembly Clamp for Earth Wire
25Mid span compression joint for Earth Wire
26Long Rod Polymer Insulator 70kN of light weight
27Single Tension Insulator Strings (Set of Hardware)
28Double Tension Insulator Strings (Set of Hardware)
29SECTION II: TOWER FOUNDATION & PROTECTION WALL WORKS FOR CONSTRUCTION OF NEW 66KV SINGLE CIRCUIT TRANSMISSION TOWER.
30Preparatory Works
31Site levelling, Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
32Setting of stubs excluding cost of excavation and concreting:
33For Large Angle Tension tower.
34Excavation
35Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m.
36Normal Dry Soil (46%) as per SPWD Norms
37Soft Rock (27%) as per SPWD Norms
38Hard Rock (27%) as per SPWD Norms
39Concreting
40Providing and Laying in position specified grade of reinforced cement concrete 1:1.5:3 Mix (1cement, 1.5 coarse sand 3 graded stone aggregate 20mm and down nominal gauge) excluding the cost of form work, finishing & reinforcement.
41Providing and Laying in cement concrete in 1:3:6 mix (1 cement, 3 clean coarse sand, 6 stone aggragrate of 40 mm and down size) including compacting & curing etc all complete.
42Supplying, bending and placing in position mild steel including straightening, cutting, bending and placing in position including binding wire complete.
43Benching
44Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. upto 50 meters.
45Revetment Work
46Providing and laying hand packed stone soling in buildings works with clean hard selected stones, all complete. (Manual Means)
47Providing and Laying in position cement concrete of specified grade 1:2:4 mix (1 cement, 2 coarse sand, 4 graded stone aggregate of 20mm & down size) including compacting curing etc all complete.
48Providing and Laying hand packed stone filing in building works with clean hard selected stones, all complete.
49Mansory Work
50Providing and Laying Plum concrete in 1:4:8 c.c. (1cement, 4 coarse sand, 8 clean hard graded stone chips of 40 mm down nominal gauge) with 70% clean hard stone of sizes not exceeding 15cm including shuttering, compacting and curing complete, as per the direction of Engineer in Charge.
51Providing and laying Hand Packed wall with clean hard selected stone including centering aligning and slopes/curves etc, complete as per the direction of Engineer in Charge .
52Consumption for stock materials
53Loading and Unloading of Cement or Steel by manual means and stacking
54Cost of Haulage excluding loading and Unloading a Katcha Track and Track in River Bed/Nallan Bed. (30KM)
55Headload of stock materials.
56Consumption for non-stock materials
57Loading and Unloading of Sand
58Cost of Haulage excluding loading and Unloading a Katcha Track and Track in River Bed/Nallan Bed.
59Headload of non-stock materials.
60Loading and Unloading of Stone
61Cost of Haulage excluding loading and Unloading a Katcha Track and Track in River Bed/Nallan Bed.
62Headload of non-stock materials.
63Check Survey, Tower Spotting and Pit marking at site
64Preliminary alignment profile, tower spotting check survey, prepartion of tower schedule, pegging of tower centre and pit marking.
65Clearing of Bushes, Tree Branches, crops Bamboos, etc, wherever encountered during stringing of the transmission or regular maintenance of the Tr. Line including transportation charges for Thick jungle
66SECTION III: DISMANTLING OF TWO NOS. OF 66KV TRANSMISSION TOWERS.
67Dismantling of Tower
6866kV Tower
69Destringing of Conductor
70Destringing of Earth Wire
71Loading & Unloading of Tower Parts
72Head Loading of the Tower Parts from Work Site to Road Site
73SECTION IV: ELECTRICAL MATERIALS REQUIRED FOR RETROFITTING OF 66KV TOWER.
74Fabrication, galvanizing & supply of various types of tower parts, tower/leg extensions (complete) excluding step bolt, stubs and bolts & nuts but including hangers, D-Shackles, pack washers etc. (D-Type Tower)
75Mild Steel
76Fabrication, cutting & fixing of suitable strengthening and stitching of with similar leg member and safety by cutting with chisel/electrical cutter/gas cutter and tower site critical gang and camp shifting per tower as per site condition and inculding vehicle hiring charge for transportating gang mobilization and demobilization.
77SECTION-I: ERECTION, TESTING AND COMMISSIONING OF 2 X 5 MVA, 66/11 KV SUB STATION.
78Power Transformer:
795MVA, 66/11KV 3Phase Star/Delta with on load tap changer oil filled transformer with accessories for protection and indication with first filling of oil and 10% spare oil in non- returnable drums, complete with neutral C.T and other standard fittings (Kirloskar) Conforming to IS:2026 (Part I to IV) Oil IS:335
80Circuit Breaker:
8172.5 KV ,3150 A, 31.5 KVA SF6 breakers complete with operating mechanism, including first filling of SF6gas complete with supporting structures, accessories, filling kit and terminal connectors.
8252KG SF6 gas cylinder
83Current Transformer 66 KV:
8472.5 kV Current Transformers 5 core (1 phase) 1200 -600-300-150/1-1-1-1-1 A, 5 core 0.2 class ,31.5 kA with 120%extended current rating with marshalling boxes, terminal connectors etc.
85Potential Transformer:
8666 KV/√3,110/√3 volt, single phase voltage transformer of accuracy class 0.5 and burden of 200 VA with first filling of oil and complete with terminal connectors.
87ISOLATORS:
8872.5 KV 800 ampers rated current and 12.5 KA short time rating triple pole, triple pole, gang operated out door type isolators with motor operated mechanism, terminal connector, earthing connectors with/without earthing blade.
89Lightning Arrestors:
9060 KV lighting arrestors complete with insulating phase, surge counters, terminal connectors complete as required.
91Control & Relay panel:
9266 KV Simplex type conrol and relay panel for line with 3 O/C + E/F trip circuit supervision, master trip, distance protection relay, digital recording and indicating instrument alarm, TTB AC/DC failure indication, panel illumination etc suitable for line feeder.
93Transformer (CB relay panel without A/R)
94Control Cables:
951.1 KV heavy duty PVC insulated PVC sheathed copper conductor control cable armoured of following sizes.
962x2.5 sq.mm
974x2.5 sq.mm
9812x2.5 sq.mm
994 core 6 sq.mm
100POWER CABLES:
1016.35 KV (UO) / 11 KV(U) XLPE Insulated Armoured Cable With Aluminium Conductor Conforming To Is:7098 Part-2: 1 C x 400 sq.mm 11 KV XLPE Cable
102DCDB to Battery Bank (2 Core, 20 mm2)
103DCDB to RTU Panel (2 Core, 2.5 mm2)
104ACDB to RTU panel (4 Core, 2.5 mm2)
105CABLE TERMINATION KIT:
106Heat shrinkable end termination kit for 11 KV XLPE Cable of following sizes:
1071 c x400 sqmm
108TRANSFORMER BASE:
109H-Beam 9 Mtr 152x152 mm 37.1 Kg/Mtr
110Back Clamp for H-Beam Pole of 65x8 mm MS flat
111M.S Nuts & Bolts 12mm diax 100mm full thread conforming to IS: 1364
11266 kV danger board
113Sub-Station Galvanized Steel Structure Conforming To - IS 5358
114Lattice structure with fasteners etc.(HT)
115Standard structure for equipment support (other than CB)-(HT)
116Bus- Bar Equipments:
117Set of 66 KV tension insulators string comprising of 7 nos B/S type disc insulator having minimum breaking strength 70 KN including necessary hardware and fittings.
118Post top insulators for busbar equipment.
119A.C.S.R Conductors Conforming To Is: 398 Part 2: PANTHER Conductor 200 sqm, 30/3.0+7/3.0
120Equipments to Panther Connector
121OVERHEAD SHIELDING:
122lighting cum lighting masts
123GI wire
124Earth pit treated
125Illumination fixture:
1268.5 Mtrs. Long 410-SP-18 swaged type steel tubular pole with CI base plate & cap, double part ( Nuts & bolts type) working load 120 Kgs
127STREET LIGHT LED Street light 90 Watt
1281.1KV PVC/ XLPE insulated power cable 2core x 16 sqmm
129Rigid U PVC Pipe as per IS 4985-2000 working pressure 6 Kgf/Cm2: 50 mm dia
130Pipe Accessories: PVC Bends 50/75 mm dia
131Flexible super PVC Green Pipe 3.5Kg/Cm2 conforming To IS: 4985-2000: 2\\" dia
132Earthing:
133a) Earthing Coil of 115 turns of 50 mm dia and 2.5 Mtr lead of 40 mm GI wire etc., as required.
134b) Back Fill Chemical Compound
135c) Earthing Plate, G.I ( 12\\" x 12 \\")
136Polycarbonate junction box wuth bus bar arrangenebt and 6 amp MCB
137Digital Time Switch for Street Light.
138Painting of steel Tubler poles:
139a) Red Oxide Paint
140b) Aluminium Paint
141SUB STATION EARTHING:
14240mm MS rod for main earth mat
14375x12 mm GI flat risers for equipments, columns and structures
14450 x 6 mm GI flats for riers for all other equipments etc
145Materials for earthing pit with supply of all earthing materials including base plate
146Concreting of above 8.5 mtr Tubular pole in 1:4:8 mix ccm in 54'x2'x2'depth earth pit and plastered parapet.
147Excavation of 0.45x0.90x1.00mtrs. Cable trench in mix soil & re-filling with available excavated earth & providing cement concrete on the top of the trench.
148SECTION-II: ERECTION, TESTING AND COMMISSIONING OF 66/11 KV CONTROL ROOM EQUIPMENT.
14911 KV, 800 Amp indoor VCB Panels with indoor horizontal isolation, horizontal draw outs complete with vacuum interrupters, motor / manual operated spring charger mechanism, trip closing coils,NO+NC auxiliary contacts, anti pumping devices, mechanical counters and mechanical spring position indicator complete with provision of parts, sub elements, CTs + PTs and all accessories :
150Incomer
151Bus Coupler
152Outgoing Feeders
153Electrically insulated 11KV mats in front of electrical control panel 1mx2.5mx8mm one side checkered finished
154D.C. Equipments
155Battery bank sealed and maintenance free lead acid battery of 200AH 55Nos 2volts each with terminal voltage of 110V Conforming to IS:1652
156Battery charger set having facility for both trickle and boost charging complete with necessary protection and other instruments 110V
157Battery Bank and Battery Charger of 200AH 55Nos 2volts each with terminal voltage of 48V.
158110V DCDB totally enclosed metal clad type complete with copper bus bar, cable socket, 200A MCCB for incoming and required MCB of 32A DP, 64A FP for outgoing to 66KV & 11KV CR panel in control room.
159415V ACDB totally enclosed metal clad type complete with copper bus bar, cable socket, 400A MCCB for incoming and required MCB of 32A DP, 64A FP for outgoing to 66KV & 11KV CR panel in control room.
16048/32/24V DCDB totally enclosed metal clad type complete with copper bus bar, cable socket,100A MCCB for incoming and required MCB of 32A -10Nos DP, 64A FP- 10 Nos, 10/20 A DP-10Nos for outgoing to 11KV CR panel in control room.
161Portable Fire Extinguishers Conforming To Is 2190: 1992
1624.5 Kg CO2 Type
1634.5 Kg DCP Type
16412 Fire buckets with stand
165Smoke detection system with all accessories and fittings
166M.S chequered plate
167M.S angle 50mmx50mmx6mm
168Safe Earthing model T-39 short time current 50 KA rms for 1 sec (EHV) application 80 mm dia x 3 mtrs. Electrode & two bags backfill chemical compound for auxilary transformer and control room.
169G.I Strips 35x6 mm of 1 Mtr length conforming to IS 227 for looping earth to individual panel and transformer
170METERING: DLMS compliant 3 ph 4wire, 0.2s class CT/PT operated fully static and AMR compatible trivector Energy Meter for HT consumer, Panel metering and 11KV feeder metering, CTR -/5 or -/1 A and PTR -/110 V.
171Vehicle Acklift
172SECTION-III: INSTALLATION OF AUXILIARY TRANSFORMER.
173250 KVA, 11/0.433 KV, 50 Hz, 3 Phase, Dry Type, Distribution Transformer Conforming To Is:11171 & 2026.
174L.T distribution switch board with copper bus bar, out-door type Kiosk, having electrolytic annealed copper bus bar 50x12mm for phase & 50x6mm for neutral circuits mounted on glazed porcelain or Bakelite base & fitted with voltmeter, ammeter, selector switches for ammeter & voltmeter, electronic KWH meter, indicating lamps cabin light, fabricated with 12 gauge M.S plain sheet, painted with anti- rust primer & two coats of Epoxy paint of shade 631 as per IS: 8623-1, front opening doors with gasket & locking arrangement complete with following incoming & outgoing controls: LTDB 400 A INCOMING: 1 No. 400 A, 4P,50KA, MCCB OUTGOING: 1 No. 200A TP MCCB, 50 KA ,2 Nos. 100A TP MCCB, 35 KA & 1 No. 63A TP MCCB, 35 KA all with built in Thermo Magnetic Release.
175D.G. Set 62.5KVA for backup arrangement.
176Changeover Switch: Automatic changeover with current limiter 125A
1771.1 kV XLPE LT ARMOURED cable of followig sizes:
1783.5 core 300 sq mm
1793.5 core 50 sq mm
180L.T 1.1 Kv cable termination kit for
1813.5 core 300 sq mm
1823.5 core 50 sq mm
183Safe earthing model T-19 short time current 20 KA rms for sec (LV/MV) application with 50 mm dia x 3 mtrs electrode & two black filled chemical compound.
18411 KV danger plate of size 8\\"x6 \\"
185Placement of L.T Distribution board on parapet of size 2x0.61x0.35x0.61 mtrs in 1:3:6 C.C mix including 12 mm thick cement plaster in 1:4 mix.
186SECTION-IV: POWER EVACUATION UPTO TEE-OFF ARRANGEMENT.
187TEE-OFF ARRANGEMENT
188H-Beam 9 Mtr 152x152 mm 37.1 Kg/Mtr
189DC Cross Arms Centre to centre 100x50x6 mm ISMC Channel (for H Beams supports/ poles)
190Back Clamp for H-Beam Pole of 65x8 mm MS flat
191M.S nuts & bolts 16mm diax40mm length.
19211 KV, 3 Pole 400amp, Air Break G.O.S tilting type, three insulator per phase, complete with all fittings conforming to IS:9920 & IS: 9921 (Porcelain/Polymer)
1939 KV, 10 KA Single pole unit Metal Oxide Gapless Surge Arrestor for 11 KV, 50 c/s solidly earthed neutral system conforming to IS:3070 (Part III) Raychem RPG make or equivalent
194Safe Earthing model T-19 short time current 20 KA rms for 1 sec (LV/MV) application with 50 mm dia x 2 mtrs electrode & one backfill chemical compound
19511kv danger board
196Painting of Structure with Red oxide paint@ 1 ltr/pole.
197Painting of Structure with AL paint@ 1.5 ltr/pole.
198Barbed wire @ 2Kg/pole
199Covered conductor 99 Sq. mm.
20011 KV Termination Kit for Covered Conductor
20111KV XLPE CABLE
2023 core 240 sq mm
2033 core 120 sq mm
204Heat shrinkable Outdoor type end termination kit for 6.6KV (UE) / 11 KV (E) 3 Core XLPE (Kit No. EOKT-3332-3382)(Raychem make or equivalent)
2053 core 240 sq mm
2063 core 120 sq mm
207Heat shrinkable Indoor type End termination kit for 6.6KV (UE) / 11 KV (E) 3 Core XLPE (Kit No. EPKT-3091-3131)(Raychem make or equivalent)
2083 core 240 sq mm
2093 core 120 sq mm
210Heat shrinkable Jointing Kit
2113 core 240 sq mm
2123 core 120 sq mm
213RIGID U PVC PIPE 110mm
2144\\"dia, Flexible Super Pvc Green Pipe 3.5Kg/Cm2 Conforming To Is: 4985-2000.
215Cable Marker for UG Cable
216Excavation of 0.45x0.90x1.00mtrs. Cable trench in mix soil & re-filling with available excavated earth & providing cement concrete on the top of the trench.
217Concreting of 9 Mtr H-Beam in 1:3:6 mix
218SECTION-V: ESTIMATE FOR INTEGRATION OF 66/11KV, 2X5 MVA SUB-STATION WITH STATE LOAD DESPATCH CENTRE (SLDC), SIKKIM.
219OPGW Cable, approach cable and accessories
22024 Fibre (DWSM) OPGW fibre optic cable
221Hardware set for OPGW CABLE
222Joint Box (24 Fibre) as per technical requirement
223FODP 48F: Indoor Type, rack mounted with FCPC Coupling and pigtails (5 mtrs each)
224Fibre Optic approach cable, 24 Fibre (DWSM)
225Hardware set for above 24 fibre, Fibre Optic Approach Cable
226Remote Terminal Unit
227RTU base equiqment comprising panels, racks, sub-racks,Power Supply modules, Communication modules, interfacing equipment, required converters & all required items/accessories including complete wiring for all modules
228OLTC transducer
229Heavy Duty Relay
230Contact Multiplaying Relay (CMRs)
231Multi Function Transducers (MFTs)
232Time Synchronisation equipment without display
233Digital Input Module
234Digital Output Module
2352-port ethernet LAN Module
236110/48V DC to 12V DC Supply
2376U rack
238Comprehensive Integration of new bays in the RTU & control centres (Main, Back-up & ERLDC) including supply of MFT, cables, CMR etc/any hardwares
2392.5mm/14C-DI Hv Side (copper)
2402.5mm/7C-DI Lv Side (copper)
2412.5mm/4C for DO(Trip/Close)(copper)
2422 core x 16 sqmm XLPE heavy duty power cables
243GPRS based Modem for backup data connectivity from RTU to SLDC
244For Control Location
245Industrial grade 16 ports serial server,230V AC Power Input (19\\" Rack mount type)
246Ethernet Module
247For remote location (Grid Sub-Stations)
248RTU site equipments: Industrial grade GPRS based Cellular server, one RS232 Port, one no.10/100 Ethernet port,IP 30 Protected Case support DTU functions, routing Firewall
249ABT meter with facility for AMR and compliant to CEA technical standard for Special Energy Meter (SEM)
250ABT based scheduling software
25111 KV CTPT Combined Cubicle Panel type metering unit with different CTR ../5 or 1A and PTR 11KV/110 V 0.2s Accuracy class
252Router Board with min 4 Ports
253SECTION-VI: INTERNAL ELECTRIFICATION OF 66/11 KV SUB-STATION CONTROL ROOM BUILDING.
254WIRING WITH PVC INSULATED (FRLSH) SINGLE CORE MULTISTANT COPPER CONDUCTOR VOLTAGE GRADE UPTO 1100V IN MS SURFACE CONDUIT PIPE.
255Wiring for light/Fan/Call bell & 6 A plug point with 2 x 1.5 sqmm FRLSH PVC insulated copper conductor single core cable in surface 19mm dia MS conduit pipe and earthing the point with 1x1.5 sqmm FRLSH PVC insulated copper conductor single core cable as required.
256Wiring for 16 A plug point with 2x2.5 sqmm FRLSH PVC insulated copper conductor single core cable in 19mm dia MS surface conduit pipe and earthing the point with1x 2.5 sqmm FRLSH PVC insulated copper conductor single core cable as required.
257Wiring for sub-main with 2x6.0 sqmm FRLSH PVC insulated copper conductor single core cable in 25mm dia MS surface conduit pipe and earthing the point with 1x6.0 sqmm FRLSH PVC insulated copper conductor single core cable as required.
258Supplying & fixing Conduit inspection bend 1/2\\",3/4 & 1\\"
259Supplying & fixing Conduit inspection Tee 1/2\\",3/4\\" & 1\\"
260Supplying & fixing Conduit inspection round 1/2\\",3/4\\" & 1\\" (1, 2,3 & 4 way)
261SWITCH, SOCKET AND ACCESSORIES MODULAR TYPE (PREMIUM)
262Supplying & fixing 06 amps 1 way FT switch on white moduler plate and metal flux box including connection etc. as required.
2631 no. 06 amps FT switch with 1 no white 1 moduler plate and 1 moduler metal flux box.
2642 no. 06 amps FT switch with 1 no white 2 moduler plate and 2 moduler metal flux box.
2653 no. 06 amps FT switch with 1 no white 3 moduler plate and 3 moduler metal flux box.
2664 no. 06 amps FT switch with 1 no white 4 moduler plate and 4 moduler metal flux box.
2676 no. 06 amps FT switch with 1 no white 6 moduler plate and 6 moduler metal flux box.
2688 no. 06 amps FT switch with 1 no white 8 moduler plate and 8 moduler metal flux box.
269Supplying & fixing 1 no. 06 amps socket with 1no. 06 amps switch, 1 no. 3 module white plate & 1 no. 3 module metal flux box) including connection etc. as required.
270Supplying & fixing 1 no. 16 amps socket, & 16 amps switch, white plate (4 module) & Metal flux box (4 module) including connection etc. as required.
271Supplying & fixing 1 no. fan step regulator 120 watts, 1 no. white plate (2 module) and 1 no. (2 module) metal flux box including connection etc. as required.
272Supplying & fixing 1 no. 2 way switch with 1 no 1module white plate & 1 no 1 module metal flux box including connection etc. as required.
273LIGHT FITTING & ACCESSORIES
274Supplying & fixing LED tube light fitting 22 watts 4 ft including connection etc. as required..
275Supplying & fixing surface LED fitting 12 watts including connection etc. as required.
276Supplying & fixing Angle/Batten holder with 9 watts LED lamp including connection etc. as required.
277Supplying & fixing wall lamp fitting (Decorative) with LED lamp including connection etc. as required.
278Supplying, Installation, testing & commissioning of Ceiling Fan 1200mm with complete accessories including connection as required.
279Supplying, Installation, testing & commissioning of ventilating fan 250mm including connection as required.
280Supplying & fixing Calling bell (Ding-Dong) with 100mm x 150mm sunmica box including connection etc. as required.
281Supplying, Installation ,testing & commissioning of storage water heater including connection as required.
28225 ltr capacity
283DISTRIBUTION SYSTEM, SERVICE CONNECTION & EARTHING
284Supplying, installation, testing & commissioning of Main switch fuse units
285Triple pole & neutral 100 amps / 415 V
286Supplying, installation, testing & commissioning of Copper Bus-bar chamber
2874 pole 063 Amps
288Supplying, installation, testing & commissioning of Miniature circuit breaker
289Double pole 40 amps.
290Single pole 6 Amp
291Single pole 16 Amp.
292Supplying & installation of MCB distribution board Double Door/Single door
2938 ways SPN (Double door)
294Providing, laying, testing & commissioning of 1.1 KV grade PVC insulated aluminium armoured conductor cable on surface of the wall of building with required size of aluminium shadle and screw etc. as required.
2953.5 core 35 sqmm
296Surge Protection Device: SPD 40KA 3P + N, (Type 2 SPDs ) 2 Mod
297Providing & earthing with 2 mtr. Long safe earthing with T-19 electrode & 1 bag back fill chemical compound
298ProvIding & laying of G.I. strips 25mm X 5mm looping earth from earth electrode to main distribution system of the building
299SECTION-VII: ESTIMATE FOR TOOLS AND PLANTS REQUIRED AT 66/11 KV SUB-STATION.
300Blow Lamp Burner
301Blow Lamp Brass
302Blow Lamp Gas Cartridge
303Combination plier 8\\"
304Combination plier 12\\"
305Cotton Waste
306Cantilever Tool Box
307Chain pulley block 5 Ton -3mtr
308Crimping tool hand operated (25sqmm to 400sqmm)
309Chain Saw (Motorized) extremely robust and long lasting chain suitable for cutting trees,thining shrubs and bushes and lopping branches with 2 kw generator
310Digital Insulation Resistance tester,All d.c voltage available ( 0.5, 1.0. 2.5. & 5.0 ) KV, Micro processor based of Meggar make.
311Digital Earth Tester (0-20/200/2000ohms, 4 terminal with testing kit and cables in hard carrying case.
312Digital clamp meter AC/DC .
313Digital cable fault locator underground CFL-02
314Earth discharge rod 66-132kv 1 phase highly insulated FRP
315Electrical Safety Hand gloves, working voltage 11 KV (Tested 33 KV )
316Electrician Hammer
317First Aid Kit with medicine
318Full body Safety harness (PN43(01))
319Hacksaw Frame
320Hacksaw blade
321Hacksaw Blade carbon steel
322High Visibility Reflective Jackets
323Head mount Rechargable LED flash light
324Insulation Resistance Tester, Analogue (Hand driven generator type ), 5KV (1000-20000) Mohms
325Ladder Extension type 10 mtr. (Al)
326Manila rope of all size
327Max.pully 8 Ton pulling & 5 ton lifting, wire rope dia 20mm,10mtr.
328Phase sequence meter
329Pulley (Runner) 8\\"
330Petroleum Jelly
331Rain coat with hoods
332Ring Spanner set 6-32mm
333Retractable Utility Knife, 156mm
334Round File Smooth RD-3503
335sf6 gas leakage detector
336Screw Driver Set 5 blades (Tester Set)
337Safety Cut Resistance, Protective Hand Gloves.
338Safety shoe leather having PU Sole with Electrical Shock Resistance upto 13-22 kv.
339Sign Board Men at work
340Sign Board Shutdown
341Torch Light LED 5 watt
342Telescopic Branch prunes saw with 12 inch cutting Bar
343Welding Machine
344Wire Stripping Plier 6\\"
345BDV Test kit (2.5/4 mm) - 100 KV Microprocessor based
346Oil sampling bottle
347Portable SF6 gas refilling device
348Transformer winding resistance meter
349Automatic Transformer turns ratio meter (Micro processor based) of Meggar make.
350Insulation Resistance Tester, Analogue (Hand driven generator type ), 1 KV (100-2000) Mohms
351DETAIL ESTIMATE FOR CONSTRUCTION OF 66/11 control room
352Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared.
353Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. (Building)
354Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber) for foundation,footings,base of column etc for mass concrete. (Footing)
355Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber) for square columns (rectangular)
356Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber) for beams, lintels griders bresumers and cantilevers
357Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber) for floor slab roof slab landing balcony and access platform
358Providing and laying hand packed stone soling in buildings works with clean hard selected stones, all complete. (Manual means)
359Providing and Laying in position cement concrete of specifiedgrade including compacting curing etc all complete.1:2:4 mix. (1 cement, 2 coarse sand, 4 graded stone aggregate of 20mm & down size)
360Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of form work, finishing and reinforcements.1:1.5:3 Mix (1cement, 1.5 coarse sand 3 graded stoneaggregate 20mm and down nominal gauge)
361Supplying, bending and placing in position tor steel reinforcement in all R.C.C works including cost of binding wires, all complete.
362providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300mm thick AAC blocks in super structure above plinth level up to floor v level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer incharge. (the payment of RCC band and reinforcement shall be made for separately)
363Providing and Laying 15mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing etc all complete 1:3 Mix
364Providing and Laying white or colored glazed vitrified tiles Pearl (white, marvel Atlanta, jet black etc or equivalent) in flooring, treads of steps landing etc laid on a bed of 15mm, cm 1:3 (1cement, 3coarse sand) finished with flush pointing with white cement slurry.
365Providing & Laying white or colored glazed vitrified tiles ofOrient / Somani or equivalent colour in flooring, treads of stepslanding etc laid on a bed of 15mm, cm 1:3 (1cement, 3coarsesand) finished with flush pointing with white cement slurry.market rate 650/sqft
366Providing and Laying white or colored glazed tiles anti skid ( elegant, cashmere, Egyptian rustic, celebrity, lara etc or equivalent) of glossy series or celebrity, elegant or equivalent in flooring, treads of steps landing etc of size 300mm x 300mm laid on a bed of 15mm, cm 1:3 (1cement, 3coarse sand) finished with flush pointing with white cement slurry.
367Providing & Laying white or colored glazed vitrified tiles ofOrient / Somani or equivalent colour in flooring, treads of stepslanding etc laid on a bed of 15mm, cm 1:3 (1cement, 3coarsesand) finished with flush pointing with white cement slurry.market rate 650/sqft
368Providing fitting & fixing of dressed sal timber in all types of frames complete
369Providing fitting and fixing in position of fully paneled shuttersin windows and doors of champ timber or equivalent includingsteel butt hinges screws 12mm thick panels etc complete.32mm thick panel door
370Providing hold fast of (40x5)mm flat iron including fixing to frame with 10mm dia. Bolts nuts and timber plugs and embedding in CC 1:3:6 ( 1 cement, 3 coarse sand, 6 graded stone aggregate 2omm nominal size) block of size (30x10x15)cm. as per the direction of Engineer - in- Charge all complete:
371Providing fitting and fixing sliding door bolts with nuts and screws etc all complete. Brass ( Bright finish.)
372Providing fitting and fixing Tower bolts 300mm x 10 mm ( barrel type) with nuts and screws etc all complete. Brass ( Bright finish.)
373Providing fitting and fixing handles 125mm size with necessary screws etc all complete. Brass ( Bright finish.)
374Providing and fixing anodized aluminum works for doors,windows, ventilators and partitions with extruded built upstandard tubular or other section of approved make confirmingIS 733 and IS 1285, fixed with rawl plugs and screws or withfixing clips or with expansion hold fasteners i/c necessary fillingup the gaps at junctions, at top, bottom and sides with requiredPVC / neoprene felt, etc. Al. section shall be smooth, rust free,straight, mitered and joined mechanically wherever required i/ccleat angle, Al snap beading for glazing / paneling CP brass /stainless screws, all complete as per design and drawings andthe direction of the Engineer - in - Charge
375Providing and laying plaster of paris putty of 2mm thick over plastered surface to prepare the surface even and smooth all complete:
376Providing and distempering with oil bound washable acrylic distemper two or more coats of approved brand or manufacture over a coat of cement primer to give an even shade on new surface including preparation of surface etc complete.
377Providing and Providing and painting with acrylic exterior paints of quality and make equivalent to EXCEL, WEATHER SHIELD to give an even shade including brushing the surface clean of dirt, dust etc and sand papering and filling the scratches complete on New surface.
378Providing, fitting and fixing white vitreous china pedestal (European type) water closet (W.C) pan with seat and lid, with C.P. brass hinges, 10ltr low level cistern with fittings and brackets 40mm flush bend, 20mm overflow pipe with specials, including Providing and painting and making good the wall and floors as required all complete: W.C. pan European One pice (Ivory) CAT NO 92008
379Providing, fitting and fixing white vitreous china flat back or wall corner type lipped front urinal basin of size 440x315x325 mm with 5 ltr automatic flushing cistern with C.I. brackets, GI flush pipe and spreaders with brass unions and G.I. clamps including cutting and making good the walls and floors as required all complete: Range of 1 Urinal basin.
380Providing, fitting and fixing. white vitreous china wash angle back basin with CI brackets, painted, 15mm CP brass pillar taps, CP brass chain with rubber plug, 32mm CP brass waste pipe, lead or PVC connection 32mm dia CP 'brass cap and unions, brass stop cock, complete including cutting and making good the walls wherever required.One wash basin with one pillar cock 35 cm x 35 cm
381Providing and fitting chromium plated toilet paper holder including the making holes and fixed to timber cleats with CP screws washer etc. all complete:.
382Providing, fitting and fixing Beveled gauge mirror of superior glass with 6mm A.C. sheets ground and fixed to timber cleats with CP screws, washer etc complete
383Providing and fitting Porcelain soap tray all complete.
384Providing, fitting and fixing soil, waste and vent pipes including testing etc complete160 mm dia. PRINCE / SUPREME or equivalent soil pipe
385Providing, Fitting and fixing PVC 32mm dia pipe complete withGI fittings and clamps including cuttings and making good thewalls etc. on wall for wash basin connector to main line
386Fittings
387Providing and placing on terrace high density polyethylenewater storage tank with man hole lid and suitable lockingarrangement including making holes for inlet, out let and ballcock including testing etc. all complete: (Sintex or equivalent 2000 LITERS CAPACITY
388Providing and fixing M.S grills in timber frames of windows with M.S flats with nuts, bolts, and smooth finishing of welded joints/surface with Grills weighing 8.00Kg/sqm as per the direction of Engineer - in- Charge all complete
389Providing and fixing M.S grills in timber frames of windows with M.S flats with nuts, bolts, and smooth finishing of welded joints/surface with Grills weighing 8.00Kg/sqm as per the direction of Engineer - in- Charge all complete
390THEORITICAL CONSUMPTION OF MATERIALS
391CEMENT
392STONE
393STEEL
394loading and unloading of cement steel by manual means and stacking (Cement - 69.60 qtls, Steel- 8.41 mt)
395Carriag of cement steel within 102 km
396loading and unloading of sand by manual means
397Carriage of sandwithin 40km
398loading and unloading of 20mm by manual means
399Carriage of 20mm within 40km
400loading and unloading of stone by manual means
401Carriage oft stone within 40km
402APPROACH ROAD
403Hill side cutting by mechanical means i/c throwing of spoils for all lead and lift complete
404Earth work excavation in foundation trenches in mixed soil i/c throwing of spoils within 1.5m lift and 50m lead from work site.
405Providing and Laying Plum concrete in 1:2:4 c.c. (1cement, 2coarse sand, 4clean hard graded stone chips of 20 mm down nominal gauge) with 50% clean hard stone of sizes not exceeding 15cm including shuttering, compacting and curing complete, as per the direction of Engineer in Charge.
406Providing and laying hand packed stone soling with clean hard selected stones all complete.(mechanical means)
407Providing box drain of 30 cm (ht.) x 45 cm (width) internal dimension with 1:2:4 Plum concrete (1cement, 2 clean coarse sand, 4 clean hard selected stone chips of size 20 mm and down nominal gauge) in side walls thickness of 23 cm ( hill side) and 30 cm (road side) and 1:3:6 c.c mix (1cement, 3 clean coarse sand, 6 clean hard selected stone chips of size 20 mm and down nominal gauge) base concrete of thickness of 15 cm with standard specification over 15 cmm stone soling all complete.
408Road drain
409Providing and laying in position cement concrfete of specified grade including compacting curing etc. all complete with Recron 3S of fiber length 6 or 12 mm (125 gm of recron 3S per a bag of cement) as per the direction of the Engineer in Charge.( 1:2:4)
410Providing & Laying in position specified grade of reinforced cement concrete of nominal mix excluding the cost of form work, finishing & reinforcements with Recron 3S of fiber length 6 or 12 mm (125 gm of recron 3S per a bag of cement) as per the direction of Engineer in Charge.(1:1.5:3)
411Providing, fixing and removing form work for casting RCC items as indicated above:
412Supply, bending and placing in position for Tor steel reinforcement in all RCC works including the cost of bending wire all complete.
413Vide item no (5):
414Provision for Admixture
415Consumption of stock material
416Cement:
417Vide item no(4):
418Vide item no(4):
419Vide item no(4):
420Vide item no(5):
421Tor Steel:
422Loading/unloading/Stacking
423Cost of Haulage 102 km
424Head Load 100m
425Consumption of non stock material SAND
426Sand:
427Vide item no(4):
428Vide item no(4):
429Vide item no(4):
430Vide item no(5):
431Loading/unloading/Stacking
432Cost of Haulage 80 km
433Head Load 100m
434Consumption of non stock STONE
435stone:
436Vide item no(3):
437Vide item no(4):
438Vide item no(3):
439Vide item no(4):
440Vide item no(4):
441Vide item no(4):
442Vide item no(5):
443Loading/unloading/Stacking
444Cost of Haulage @5.57/ton/km 40 km
445Head Load 100m
446PROTECTIVE WORKS
447site development, levelling clearing jungle all complete by engaging labur all complete.
448Excavation work by mechanical means (Hydraulic Excavator)/manual means in foundation trenches or drains not exceeding1.5 m in width or 10 sqm on plan including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out theexcavated soil and disposal of surplus excavated soils asdirected, within a lead of 50m
449Retaining Wall
450Breast Wall
451Providing and Laying Plum concrete in 1:2:4 c.c. (1cement,2coarse sand, 4clean hard graded stone chips of 20 mm downnominal gauge) with 70% clean hard stone of sizes notexceeding 15cm including shuttering, compacting and curingcomplete, as per the direction of Engineer in Charge.
452Retaining Wall
453Breast Wall
454THEORITICAL CONSUMPTION OF MATERIALS
455CEMENT
456VI ITEM 3
457Loading and Unloading of Cement l by Manual Means and Stacking.
458Carriage of cement within102 km radius
459VI ITEM 3
460Loading and Unloading of Sand.
461Carriage of sand 30 km surface road.
462STONE
463VI ITEM 3
464Loading and Unloading of stone
465Carriage of stone 30km surface road.
46620 mm
467Loading and Unloading of 20 mm chips.
468Carriage of 20 mm chips 30km surface road.
469SWITCHYARD
470Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
471Cable Trench along Switchyard
472Type A
473Type B
474Type C
475Lighting Tower
476Providing and laying hand packed stone soling in buildings works with clean hard selected stones, all complete. (Manual means)
477Along Dead End Gantry
478Along Control Room Building
479Cable Trench along Switchyard
480Type A
481Type B
482Type C
483Lighting Tower
484Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete. 1:3:6 mix. (1 cement, 3 coarse sand, 6 stone aggregate of 20mm & down size)
485Along Dead End Gantry
486Along Control Room Building
487Cable Trench along Switchyard
488Type A
489Type B
490Type C
491Lighting Tower
492Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
493GANTRY AND DEAD END TOWERS
494SF6 Breaker
495Isolator
496Lightining Mast
497Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of form work, finishing and reinforcements.1:1.5:3Mix (1cement, 1.5 coarse sand 3graded stone aggregate 20mm and down nominal gauge)
498GANTRY AND DEAD END TOWERS
499SF 6 Breaker
500Isolator
501Lightining Mast
502Step - 1 Footing
503Step -1 Footing
504Cable Trench Along Switchyard- Floor Type A
505Cable Trench Along Switchyard- Floor Type B
506Cable Trench Along Switchyard- Floor Type C
507Cable Trench Along Switchyard- Walls Type A
508Cable Trench Along Switchyard- Walls Type B
509Cable Trench Along Switchyard- Walls Type C
510Supplying, bending and placing in position tor steel reinforcement in all R.C.C works including cost of binding wires, all complete.
511Providing, fixing & removing form work for casting R.C.C items as indicated below: with imported timber from outside the state), Square columns
512GANTRY AND DEAD END TOWERS
513SF6 Breaker
514Isolator
515Transformer 1
516Transformer 2
517Lighting Tower
518Cable Trench Along Switchyard- Walls Type A
519Cable Trench Along Switchyard- Walls Type B
520Cable Trench Along Switchyard- Walls Type C
521QUARRYING OF STONE, STONE CHIPS, SAND AND EARTH.- 39mm to 64mm.
522Stone spreading in switchyard excluding PCC- STONE SPREADING IN SWITCHYARD
523THEORITICAL CONSUMPTION OF MATERIALS
524CEMENT
525STONE
526STEEL
527Cost of Haulage Excluding Loading and Unloading of Stock Material from: 102 KM (Surfaced Road)
528Loading and Unloading of Cement and Steel by Manual Means and Stacking.
529Cost of Haulage Excluding Loading and Unloading Non-Stock Material from: 65 KM (Surfaced Road)
530Stone
531Head load of non-stock materials for a distance beyond 30 m and within 100 m distance
532Stone
533FENCING
534Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m.
535Providing and laying hand packed stone soling with clean hard selected stones all complete
536Providing and laying in position cement concrete in 1:2:4 mix i/c compacting curing all complete.
537Supplying Fabricating, fixing pointing and erection of M.S angle of size 50 x 50 x 6 mm
538Supplying Fabricating, fixing pointing and erection of M.S flat of size 50x 6 mm
539Brickwork in half brick thick 1:4 cement mortar
540Providing and laying 15mm thick cement plaster of specified mix in single coat including finishing even and smooth curing all complete
541THEORITICAL CONSUMPTION OF MATERIALS
542CEMENT
543VI ITEM 3
544VI ITEM 6
545VI ITEM 7
546Loading and Unloading of Cement l by Manual Means and Stacking.
547Carriage of cement within102 km radius
548VI ITEM 3
549VI ITEM 6
550VI ITEM 7
551Loading and Unloading of Sand.
552Carriage of sand 30 km surface road.
55320 mm
554Loading and Unloading of 20 mm chips.
555Carriage of 20 mm chips 30km surface road.
556Fencing with welded steel fabric 75mm x 50 mm providing 3m high fencing with welded steel wire all complete
557Provision for construction of steel Gate for entrance to switchyard 5m x 2m
558Provision for furniture and furnishing 12.5 % of A
559Provision for Internal & External Water Supply 12.5% of A Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58223123
AUTHORITY Government Departments
TENDER VALUE 22.27 Crore
LAST DATE 17-11-2026
Authority
Authority Name Energy And Power Department
Work Description Tender for Construction Of 66Kv Transmission Line And 2 X 5 Mva, 66/11 Kv Substation At National Institute Of Technology (Nit), Khamdong Under Singtam Circle, Gangtok District, Sikkim.
Basic Detail
Tender No 88/GOS/PWR/ACE/NO/25-26/520
Bidding Type Tender
Location
City sikkim
State Sikkim
Key Dates
Publish Date 07 Nov 2026
Submission Date 17 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 22.27 Crore
Tender Fee 5 Lakhs
EMD 55.69 Lakhs
Exemption Not Available
Document List
3373c912-7950-41ad-a89c-b068b83552dd.html
BOQ_995.xls
TENDERDOCUMENT.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

3373c912-7950-41ad-a89c-b068b83552dd.html

xls

BOQ_995.xls

rar

TENDERDOCUMENT.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender