Tender For Provn Of Cook House And Dinning Hall At 214 Nsc Under 859 Ews.
Tender Value
38 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
1 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tawang → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Cook House And Dinning Hall At 214 Nsc Under 859 Ews.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Nov-2026 | BOQ Corrigendum | BOQ | 17-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 n exc 3.0m m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | Rough excavation n exc 1.5m deep and getting out in soft/loose soil |
| 4 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil. |
| 5 | M&L for cement concrete 1:4:8 type D2 (40 mm graged aggregate) as in foundation and filling mass concrete complete all as specified and directed by Engr-in-Charge. |
| 6 | Use and waste flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge. |
| 7 | Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engr-in-Charge. |
| 8 | Use and waste Square, Rectangular or polygonal Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 14 | M & L for Chequered cememt concrete tiles with grey cement and pigment of size 20cm x 20cm x 25mm thick set and jointed in neat cement slurry in floors over 20mm thick screed bed in cement mortar (1:6) for laying floors complete. |
| 15 | M & L for PCC type B2 , 1:2:4 (40mmn graded aggregate) as in drain bed, surface channels complete all as specified and directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 17 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 18 | M&L for Hardcore of broken stone or boldours of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for 100mm thick Cement concrete type C2, 1:3:6 (40mm graded aggregate) as in sub base or in floors complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for 40 mm thick Cement concrete type B1, 1:2:4 (20mm graded aggregate) as in floor finishes complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes set in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/450X 300X 6to7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering 10mm se tin CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for Type C1, 1:3:6 (20mm graded aggregate) Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar mortar 1:6, complete complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L for Type C1, 1:3:6 (20mm graded aggregate) precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:6, complete, in walls complete all as specified and directed by Engr-in-Charge. |
| 25 | M&L for Rendering 15mm thick in two layers on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth complete all as specified and directed. |
| 26 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed. |
| 27 | Supplied only liquid WPC |
| 28 | M&L for Preparation of new plastered surface of wall and applying two coat of OBD over a coat of Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed. |
| 29 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces. |
| 30 | S&F Rolled mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 31 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed. |
| 32 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 33 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specifiedcomplete all as specified and directed. |
| 34 | S&F 2nd class HW plain solid straight chowkhats and frame wrought framed rebated on the soild rounded or chamfered put together with glue pinned at joints, complete all as specified and directed. |
| 35 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F 30mm thick 2nd class hardwood, Glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shuters as specified in SSR Part-I, Section 8, clause 8.24(a), fittted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed. |
| 38 | M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F 100 mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F 75mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F 200mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F 100mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 43 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 44 | S&F 100mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 45 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engr-in-Charge. |
| 46 | M&L for 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection complete all as specified and directed. |
| 47 | S&F 25mm dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 48 | S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and directed. |
| 49 | S&F 75mm PVC (SWR) bends any radius complete all as specified and directed. |
| 50 | S&F 75mm PVC (SWR) junction single, (single T) equal or unequal with access door complete all as specified and directed. |
| 51 | S&F 15mm dia Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 52 | S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 53 | M & L for form work to soffits of suspended slabs such as roof slab, landings and similar work, n.exc 200mm thick (horizontal or sloping), rough finished surfaces of concrete curved complete all as specified and as directed. |
| 54 | M &L for reinforced cement concrete (Nominal mix) (1:2:4) type B1 (using 20mm graded aggregate) as in slab supported on walls, beam and columns in floor, roof, landing, balcony, canopies, deck slab and in shelves complete all as specified and directed. |
| 55 | S & F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm. |
| 56 | M & L for Anodised aluminium snap grid frame work for false ceiling all as specified |
| 57 | M & L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 58 | M & L for Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. Wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) |
| 59 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in Chajjas complete all as specified and directed by Engr-in-Charge. |
| 60 | Use and waste Square, Rectangular or polygonal formwork to chullah hoods, chajjas thoughs and similar items including edges complete all as specified and directed by Engr-in-Charge. |
| 61 | M & L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, modulam/ /tred/stopped ends etc all as specified. |
| 62 | S & F PVC (SWR) pipes 110mm bore dia single socketed, in any length with rubber joints, laid in trenches or in floors. |
| 63 | M & L for One light point or one fan point controlled by one switch with 1.5 sq. mm size FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 64 | M & L for One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 65 | M & L for One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 66 | M & L for One 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 4.0 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 67 | S&F Switch piano, flush type single pole, one way 5 Amp. |
| 68 | S&F Switch socket combination 2 in 1, 5 A flush type. |
| 69 | S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type Universal. |
| 70 | S&F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body. |
| 71 | Supply and fixing in repair LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specified. |
| 72 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete as specified. |
| 73 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified. |
| 74 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for battern fittings complete. all as specified and directed by as engineer-in-charge. |
| 75 | S&F LED Bulb 9 watt cat part no LED PLUS 9W B22 WW 2 STAR LAMP complete all as specified and as directed by engineer-in-charge. |
| 76 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep heavey duty with, blades, and frame and louvers with all fixing arrangement all as specified and as directed. |
| 77 | S&F sheet metal enclosure distribution box 4 way TPN 415 volts with suitable size of rated bus bar double door complete including connecting up all as specified . |
| 78 | Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker TPN 40 To 100 AMP poles and current carrying capacity in the DB complete with connection testing and commissioning all as directed and as specified. |
| 79 | Supply and fixing in repair MCB 32 Amp SPN 240V, 10KA 'C' complete with connection testing and commissioning all as directed and as specified. |
| 80 | Supply and fixing in repair MCB 5- 32 Amp SP 240V, 10KA 'C' complete with connection testing and commissioning all as directed and as specified. |
| 81 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized GI wire 4.0 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and provision of concrete pit in PCC (1:3:6) type C1, pre-cast including RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm, reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways, one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil, dismantling and taking out old earthing plate and necessary testing complete all as shown on electrical plate No 5 of SSR Part –I (2009). |
| 82 | M & L for One 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 4.0 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 83 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 84 | S&F of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket and offering for credit. |
| 85 | S&F 3-layer PP-R Polypropylene random copolymer) 32 mm concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc |
| 86 | Cutting existing steel tubing 25 to 32 mm bore for alterations or additions (Each cut measured) |
| 87 | M & L for replacement of PP-R Gate valves (brass insert) of size 32 mm bore as per requirement all as directed and as specified. |
| 88 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 Core including taking down old one. |
| 89 | S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm bore. |
| 90 | S&F GI Pipe 80 mm bore, 'light grade',galvanised,with all fitting;laid in trenches. |
| 91 | Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps. |
| 92 | Supply, install ,testing and commissioning of factory made LT panel box outdoor type factory made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size to accomodate incoming/out going LT cable /service wire at least of 8-10 runs ) Neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of apprppriate size. The feeder pillar box shall be suitable for 415 volts, 50Hz , 3 phase 4 wire system & shall comprise with suitable capacity aluminium TPN bus bar chamber having 3 phase 4 wire system fixed on porceilin insulator with suitable size PVC copper conductor and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands complete all as directed with foliowing accessories and making connection with LT panel all as directed and specified.(Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed).(i) On load Changeover.4 pole of cap. 63 Amps-01 Nos. (ii) Aluminium Insulated bus bar 4P, 200 Amp from incoming & outgoing of changeover to connect the double run cable.- 1 Set(iii) Digital voltmeter with selector switch - 1 Set(iv) Digital ammeter with selector switch and CTS. (iv) RYB indicating lamps -1 Set(v) Suitable Battery charging Unit – 01 No.(v) M & L for internal wirings complete with 2.5 sqmm for timer circuits/ and 10 sqmm copper wires for out going curcuits and termination with copper thimbles. = 01 Job (vi) MCCB 4P 63 Amps,25 KA - 01 Nos ( Incoming )(vii) MCB SPN 32-40 Amps -06 Nos (Out going)(ix) MCB TPN 32-40 -06 Nos (Out going) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 17, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender