Public Administrative Department Local Bodies Closing in 6 days TDR #58222074

Tender For Provision Of Electrical Installation In Various Toilet Block In Glm Hospital

Issued by Local Bodies · Delhi, Delhi
Tender Value
4.66 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
6 days left
EMD
9328
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Electrical Installation In Various Toilet Block In Glm Hospital

BOQ

Name of Work:- Provision of electrical installation in various Toilet block in GLM Hospital
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amp switch
5b) 3 pin 5/6 amp socket outlet
6Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
7Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
8d) 8 Module (125mm X 125mm)
9e) 12 Module (200mm X 150mm)
10Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing masonry open duct asrequired.
11Supply of XLPE insulated PVC sheathed Al. Cond. Armoured cable of 1.1kV grade conforming to IS-7098 Part-I of following size, (b) 2X10 sqmm
12Supply of 12 '' (300 mm) sweep 1400 rpm exhaust fan heavy duty compleate with shutter , blades etc. as required.
13Supply of 15 '' (380 mm) sweep 1400 rpm exhaust fan heavy duty compleate with shutter , blades etc. as required.
14supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc as required .
15Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
16Supplying and fixing following piano type switch/socket on the existing switch box/ cover includingconnections etc. as required. (a)5/6 amps switch
17(b)3 pin 5/6 A socket outlet
18Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.(a) 100 mm X 100 mm X 60 mm deep
19(b) 180 mm X 100 mm X 60 mm deep
20Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a)12 way , Double door
21(b)08 way , Double door
22Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required. (a) Single pole
23Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps
24(b ) 40 A
25Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum )
26Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency 5%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of mnimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt
27P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
28Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25MM
29Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired.3 x 1.5 sq. mm
30SITC of 10W surface/wall mounted LED Bulkhead factual impact dust and water resistant luminaires with IP 65/66 protection Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58222074
AUTHORITY Local Bodies
TENDER VALUE 4.66 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of Electrical Installation In Various Toilet Block In Glm Hospital
Basic Detail
Tender No 49/MWEEE-I/2026-27/TC
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 27 Oct 2026
Submission Date 04 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 4.66 Lakhs
Tender Fee Ref. Documents
EMD 9328
Exemption Not Available
Document List
242dcb17-812b-426c-bd93-caf40e1e0d75.html
BOQ_344756.xls
DNIT04_0001.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

242dcb17-812b-426c-bd93-caf40e1e0d75.html

xls

BOQ_344756.xls

pdf

DNIT04_0001.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender