Public Administrative Department Government Departments Closing in 12 days TDR #58221398

Tender For Construction Of An Anganwadi Centre Building With Library (Model Anganwadi) In Gram Sabha Badhainikala, Vikas Khand Aaraji Line.

Issued by Government Departments · Varanasi, Uttar Pradesh
Tender Value
21.01 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
12 days left
EMD
42020
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Construction Of An Anganwadi Centre Building With Library (Model Anganwadi) In Gram Sabha Badhainikala, Vikas Khand Aaraji Line.

BOQ

Name of Work:- VIKAS KHAND AARAJI LINE GRAM SABHA BADHAINI KALAN ME LIBRARY SAHIT AANGANVADI KENDRA BHAWAN (MODEL AANGANVADI) KA NIRMAN KARYA.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for All kinds of soil.As per DSR:Vol.1:2023 item 2.8.1
2Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete,As per DSR:Vol.1:2023 item 2.25A
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).As per DSR:Vol.1:2023 item 4.1.8
4Providing and laying in position, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.As per DSR:Vol.1:2023 item 5.1.2
5Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : in 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per DSR:(Vol.-1):2023 Item 5.2.2
6Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).as per DSR:(Vol.-1):2023 Item 5.3
7Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete as per DSR:(Vol.-1):2023 Item 5.9.1
8Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform as per DSR:(Vol.-1):2023 Item 5.9.3
9Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5
10Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts as per DSR:(Vol.-1):2023 Item 5.9.6
11Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges as per DSR:(Vol.-1):2023 Item 5.9.19
12Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR:(Vol.-1):2023 Item 6.1.2
13Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand):as per DSR:(Vol.-1):2023 Item 6.4.1
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand):as per DSR:(Vol.-1):2023 Item 6.4.2
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6
16Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using flats 30x6mm for diagonal braces and central cross piece.as per DSR:(Vol.-1):2023 Item 10.5.2
17Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works10.25.2
18Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 4.0 mm thick glass panes as per DSR:(Vol.-1):2023 Item 10.30.1
1912 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) as per DSR:(Vol.-1):2023 Item 13.1.2
2015 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) as per DSR:(Vol.-1):2023 Item 13.2.2
2120 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement as per DSR:(Vol.-1):2023 Item 13.9.2
22Making groove in plastered surface or moulding to R.C.C. projections.as per DSR:(Vol.-1):2023 Item 5.30
23Making drip course in plastered surface or moulding to R.C.C. projections.as per DSR:(Vol.-1):2023 Item 5.30
24Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws:9.21.1
25Providing and laying Vitrified tiles in floor in double charged vitrified floor tiles polished finish of size 600x600mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. as per DSR:(Vol.-1):2023 Item 11.41A.1.1
26Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. as per DSR:(Vol.-1):2023 Item 11.39
27Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade as per DSR:(Vol.-1):2023 Item 8.31
28Kota stone slab flooring over 22 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick as per DSR:(Vol.-1):2023 11.26.1
29Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab complete as per DSR:(Vol.-1):2023 11.31
30Distempering Two or more coats on new work with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre, as per manufacturer's specification. as per DSR:(Vol.-2):2023 13.41.1
31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 Ltr/10 sqm):. as per DSR:(Vol.-2):2023 13.47.1
32Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per DSR:(Vol.-2):2023 Item 13.80
33Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture as per DSR:(Vol.-2):2023 Item 13.48.3
34Providing and fixing on wall face unplasticised 110mm dia Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per DSR:(Vol.-2):2023 12.41.2
35Providing and fixing on wall face unplasticised - PVC moulded 110mm Coupler fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.1.2
36Providing and fixing on wall face unplasticised - PVC moulded 110mm Bend 87.5° fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.5.2
37Providing and fixing on wall face unplasticised - PVC moulded 110mm BShoe (Plain) fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.6.2
38Providing and fixing unplasticised -PVC 110mm pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete as per DSR:(Vol.-1):2023 12.43.2
39S/Fixing of infomatary M.S sign board Size (1.2x0.90) Made of 18 mm gauge M.S.Sheet fixed in ISA 40x40x5 mm frame supported in back side by 40x5 mm fiat iron on all four side along with two vertical pont of 2.15 mt from bottom of frame of angle iron ISA 40X40X5 mm with 150 mm long horizontal lag at bottom braded with 40x5 mm flat iron ellectrically welded and pointed with one coat red oxide primer S.S. NO. 503 APPROVED BY SE RED VARANASI
40Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer or CNC METAL DOOR
41Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever requiredWhite Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests:
42Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Flat back wash Basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
43Providing & fixing white vitreous china Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board470x420 mm bowl depth 178 mm
44Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore
45Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore
46Providing & fixing cast iron trap of self cleaning design with or without ventarm complete, including cost of cutting & making good the walls & floors.a) 100mm inlet & 75mm outlet.
47Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 75 mm
48roviding and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm
49Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door 75x75x75 mm
50Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend
51Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes
52Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15mm dia nominal bore
53Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20mm dia nominal bore
54Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes
55Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
56Providing and fixing gun metal gate valve with wheel of approved quality. a) 25mm dia nominal bore
57Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
58Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
59Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire
60Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
61Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
62Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
63Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
64Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
65Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
66Supplying and fixing following way, Single pole and neutralsheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double door
67Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
68Supply and fixing following rating ,double pole, 240 V, isolated in the existing MCB DB complete with connections , testing and commisioning etc.as required. 40 A
69Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
70Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect .
71Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks
72Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 150 mm dia
73Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia
74Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
75Surounding and packing between borewell and the strainer including supply of gravel and labour , T&P etc required for proper completion of the work
76Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge..
77Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 100 mm dia
78Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm dia
79Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 100 mm dia
80Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore
81Supplying & fixing PVC insulated PVC sheathedcopper conductor submersible flat cable ISI Marked inexisting metal/ HDPE / PVC/ pipe/ in bore well/ insump including fixing the cable to GI/HDPE pipe withsuitable cable tags of following sizes etc. complete asrequired.3 Core 4.0 Sq mm Flat Cable
82Supply of submersible pump of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications. (2.0 H.P.Pump with Starter)
83Supply & installation of India Marka Handpump including necessary nut bolt complete with pedestal & platform and including making of proper connection etc. for proper completion of work. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58221398
AUTHORITY Government Departments
TENDER VALUE 21.01 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Rural Engineering Department
Work Description Tender For Construction Of An Anganwadi Centre Building With Library (Model Anganwadi) In Gram Sabha Badhainikala, Vikas Khand Aaraji Line.
Basic Detail
Tender No 2400 date 30-09-2026
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 26 Oct 2026
Submission Date 10 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 21.01 Lakhs
Tender Fee 2354
EMD 42020
Exemption Available
Document List
BOQ_2271805.xls
sbd.pdf
Tendernotice_1.pdf
a28085ef-787c-4fb3-8d98-7f8db4569cbb.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2271805.xls

pdf

sbd.pdf

pdf

Tendernotice_1.pdf

html

a28085ef-787c-4fb3-8d98-7f8db4569cbb.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender