Environment and Forests Government Departments Closing in 5 days TDR #58221397

Tender For Upgradation Of Forest Frontline Infrastructure Guard Huts At Jad, Tungi, Showara, Gala, Choura Kalidhar Range, Forest Division Jammu Under Capex During Years 2026-27.

Issued by Government Departments · Jammu, Jammu and Kashmir
Tender Value
5.40 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
5 days left
EMD
16200
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Forest Frontline Infrastructure Guard Huts At Jad, Tungi, Showara, Gala, Choura Kalidhar Range, Forest Division Jammu Under Capex During Years 2026-27.

BOQ

Name of Work:- Upgradation of Forest Frontline Infrastructure Guard Huts at Jad, Tungi, Showara, Gala, Choura Kalidhar Range, Forest Division Jammu under CAPEX during years 2026-27.
Sl. No. Item Description
1Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
2Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
3Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
4Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications
5Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on old work with outer side mesh fencing
6Finishing walls with Acrylic smooth exterior paint of required shade: Old work (two or more coats applied @ 1.67 liters/10sqm on existing cement paint surface)
7Providing and fixing Wiring for light point/exhaust fan point/ ceiling fan point /heating pointwith 1.5/2.5/4 sqmm FRLS PVC insulated copper conducter single core cable in surface/recessed medium class PVC conduit,with modular switch,modular plate suitable GI box as required. PVC pipe 2mm in slab with wall Make:- Anchor/Havells or equvalent.
8Providing and installing LED/CFL saver 14 watt of approved quality Make:- Anchor/Havels/Orient etc
9Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand)
10Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes.
11Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 20mm nominal outer dia pipes.
12Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes with wire mesh conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 110 mm diameter
13Renewing glass panes, with wooden fillets wherever necessary Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm)
14Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
15Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
16Providing Welder for two days for fixing door, windows with complete fittings
17Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,all complete as per direction of engineer- in charge. Rate for thickness of shutter in mm per sqm Deodar wood
18Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge Second class deodar wood 35mm
19Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse and), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm
20Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58221397
AUTHORITY Government Departments
TENDER VALUE 5.40 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Forest Department
Work Description Tender for Upgradation Of Forest Frontline Infrastructure Guard Huts At Jad, Tungi, Showara, Gala, Choura Kalidhar Range, Forest Division Jammu Under Capex During Years 2026-27.
Basic Detail
Tender No enit 21 of 2026-27
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 27 Oct 2026
Submission Date 02 Nov 2026
Open Date 02 Nov 2026
Finance
Tender Value 5.40 Lakhs
Tender Fee 600
EMD 16200
Exemption Not Available
Document List
50eab61c-898f-4274-8ccb-c79aa3476b26.html
BOQ_1116279.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

50eab61c-898f-4274-8ccb-c79aa3476b26.html

xls

BOQ_1116279.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender