Tender For Supply Installation Testing and Commissioning of 3 Nos. Of Tower Ac Of 4 Tons Each At Cad Cam Lab At Dbrait Sri Vijaya Puram Under Sub Division-1(R), E&M Division, Apwd, Prothrapur.
Tender Value
8.60 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
9 days left
EMD
17217
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of 3 Nos. Of Tower Ac Of 4 Tons Each At Cad Cam Lab At Dbrait Sri Vijaya Puram Under Sub Division-1(R), E&M Division, Apwd, Prothrapur.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 2 | b) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 3 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Drain Pipes for IDU of AC)a) 25 mm |
| 4 | MCB &DBSupplying and fixing 4 way MCB sheet steel Enclosure, phosphatised, powder painted with Din rail for mounting MCBs/Isolator (but without MCBS) MAKE: Legrand Cat no. 507793 or equivalent as required. |
| 5 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 A |
| 6 | Supplying and fixing of Copper bus bar (3 phase) with following rating with connections, testing and commissioning etc. as required.a) 63 A, 4 way |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Triple pole and neutral |
| 8 | Air ConditionerSITC of 4.0 Ton Floor standing Tower Air Conditioner (Single Compressor, 3 Phase 415 Volt) Make: HAIER model AP48KC1QRB or equivalent in VOLTAS/ VESTAR/ CRUISE/BLUESTAR, (Condenser Coil must be of copper materials). |
| 9 | Providing and fixing of refrigerant copper pipes of following sizes (Suction & Delivery) of Tower AC i/c providing electrical cables, insulation, gas charging, cutting, drilling holes on the wall for passing gas pipes, fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish and covering the PVC non adhesive tape over the insulation of refrigerant pipes and as per the direction of E-in-C.a) Refrigerant pipes of Sizes 3/4\\" & 3/8\\" |
| 10 | Fabrication of stand/Pedestal for keeping the indoor/out door unit of Tower/ Split type AC of various capacity made of suitable size of MS Angle and painting with one coat of red oxide and paint as required. |
| 11 | Dismantling of existing 1.5/2 Ton split type AC including both indoor unit and outdoor unit in complete with accessories including cementing 5 the holes, to give an even look and smooth finish as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender